The Environmental Effect Reduction On Internal Space Temperature By Internal Walls Covering
تقليل تأثير البيئة على درجة حرارة حيز المبنى بتغليف الجدران من الداخل (دراسـة تجريبيـة)

Author: عاطف علي حسن
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2012 Volume: 10 Issue: 2 Pages: 35-48
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

The objective of this paper is reduced the heat transferred quantities from or to internal building space by covering it's internal walls with many materials, therefore, build the (1x1x2)m room sample at 3rd floor for building in Baghdad city (L = 33.2 °N), and (1x2)m wall has east orientation, while the other surfaces were insulated by 200 mm styropor sheets, and using Air – Conditioner 0.5 Ton of refrigeration to afford the standard thermal comfort.From search result found that, the hollow faced brick (120mm thickness) with 10mm polystyrene thermal insulation used as a cover layer for ordinary wall saved 47% from electrical energy consumption in Air-Conditioner, while used solid flooring brick with thermal insulation and fiber wood with colour paper covered, the metal sheet painted with thermal plastic paint with 10 mm thermal insulation gives each one of that 41.8% saving, while the covering with one of this materials hallan stone, solid flooring brick, MDF wood with thermal insulation, metal sheet with thermal insulation and metal sheet painted with thermal plastic paint gives about 35% percentage saving, while used the marble, porcelene , ceramic and hollow plastic board (for decorative used) give electrical energy reduction percentage about 27% .

يهدف البحث الى تقليل كميات الحرارة المنتقلة من أوالى الحيز الداخلي للمبنى بتغليف الجدار الخارجي (المعرض الى البيئة) من الداخل، وباستخدام مواد متوفرة في السوق المحلية، لذلك تم تشييد غرفة أبعادها (2x1x1)م، تقع على سطح الطابق الثالث لمبنى في مدينة بغداد (خط عرض 33.2 درجة شمالاً)، والجدار (2x1) م مواجه للشرق، واستخدم لأغراض الدراسة، بينما تم عزل بقية الجدران والسقف والأرضية من الداخل باستخدام عازل حراري (ألواح الستايربور) سمك (200) ملم مع استخدام مكيفة هواء جدارية سعتها التبريدية (0.5) طن تبريد لتوفير الظروف الحرارية القياسية.توصل من خلال دراسة الأداء الحراري للجدار المغلف بالمواد، بأن استخدام طابوق الواجهات المجوف سمك (120)ملم مع العازل الحراري نوع الواح البولي ستايرين سمك 10 ملم يحقق نسبة تخفيض في الطاقة الكهربائية المستهلكة لأغراض التكييف بمقدار 47% مما يستهلكه الجدار الاعتيادي (بدون تغليف) وكذلك فان نسبة التوفير المتحققة عند التغليف بإحدى المواد – الطابوق الفرشي مع العازل الحراري، خشب الفايبر المغطى بورق الجدران مع العازل والألواح المعدنية (الألمنيوم) المطلي بالطلاء الحراري البلاستيكية قد كانت 41.8 % بينما التغليف بإحدى المواد التالية، حجر حلان، طابوق فرشي، خشب معاكس مع العازل الحراري، خشب MDF مع العازل وألواح الألمنيوم مع العازل والألواح المعدنية المطلية بالطلاء الحراري البلاستيكية قد وفرت ما يقارب 35% ، أما التغليف بالمرمر الطبيعي أو البورسلين، السيراميك ومع وجود العازل الحراري ، وألواح البلاستيك المجوف مع العازل قد حققت كل منها توفير لا يتجاوز 27% من إجمالي الطاقة المستهلكة بدون تغليف.


Article
The Environmental Effect Reduction On Internal Space Temperature By External Walls Covering (Experimental Study)
تقليل تأثير البيئة على درجة حرارة حيز المبنى بتغليف الجدران من الخارج (دراسـة تجريبيـة)

Author: Atif Ali Hassan عاطف علي حسن
Journal: Iraqi Journal of Civil Engineering المجلة العراقية للهندسة المدنية ISSN: 19927428 Year: 2012 Volume: 7 Issue: 2 Pages: 45-58
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

The object of this paper was reduced the heat transferred quantities from or to internal building space by covering it's external walls with many materials, therefore, the researcher build the (1x1x2) m room sample at 3rd floor for building in Baghdad city (L = 33.2 N°), and (1x2)m wall has East orientation , while the other surfaces were insulated by 200 mm styropor sheets, and using Air – Conditioner 0.5 Ton of refrigeration to afford the standard thermal comfort.The researcher found that, the metal sheet painted with thermal plastic paint with 10 mm thermal insulation used as a cover layer for ordinary wall saved 57% from electrical energy consumption in Air-Conditioner, while used that material without insulation layer gives 46.2% , hollow plastic board (for decorative used) gives 42.5% , hollow faced brick with thermal insulation gives 40.22%, solid flooring brick with thermal insulation gives 39.5% , colour metal sheets with air – gap gives 36.4%, asbestos – cement board coated by reflective aluminum paint gives 34%, the ceramic with thermal insulation gives 31.9%, while all the material – marble , porcelene , hallan stone , fiberglass sheets with 10 mm thermal insulation will gives the electrical energy reduction percentage less than 30% .

يهدف البحث الى تقليل كميات الحرارة المنتقلة من والى الحيز الداخلي للمبنى بتغليف الجدار الخارجي (المعرض للبيئة) للأبنية المنفذة حالياً وباستخدام مواد متوفرة في الأسواق المحلية، لذلك تم تشييد غرفة أبعادها (2x1x1) م، تقع في الطابق الثالث لمبنى موجود في مدينة بغداد (خط عرض 33.2 درجة شمالاً) ، والجدار (2x1) م مواجه للشرق، استخدم لأغراض الدراسة، بينما تم عزل بقية الجدران والأسطح من الداخل باستخدام (200) ملم عازل حراري (ستايربور) واستخدام مكيفة هواء جدارية سعتها التبريدية (0.5) طن تبريد لتوفير الظروف الحرارية القياسية.توصل الباحث من خلال دراسة السلوك الحراري للجدار بعد تغليفه بالمواد، بأن استخدام الغلاف المعدني المطلي بالأصباغ الحرارية البلاستيكية وبوجود عازل حراري سمك (10)ملم، يحقق نسبة تخفيض قدرها 57% مقارنة بما يستهلكه الجدار الاعتيادي بدون تغليف، وعند نفس التغليف ولكن بدون وجود العازل الحراري سنجد أن التخفيض يصل الى 46.2%، بينما استخدام ألواح البلاستيك المجوف (ألواح ديكور) قد حقق توفير قدره 42.5%، بينما طابوق الواجهة المجوف مع العازل الحراري يحقق نسبة تخفيض قدرها 40.22% والطابوق الفرشي الصلد مع العازل يحقق 39.5% توفير، بينما ألواح الاسبست المطلية بطلاء الألمنيوم العاكس يحقق 34% في حين حقق استخدام السيراميك وبوجود العازل الحراري توفير قدره 31.9 % ، في حين كانت نسبة التخفيض عند التغليف بالمرمر، البورسلين ، حجر الحلان، ألواح الفايبركلاس مع استخدام العازل الحراري أقل من 30% .

journal of kerbala university
مجلة جامعة كربلاء

ISSN: 18130410
Publisher: Kerbala University جامعة كربلاء
Subject: General works

Loading...
Loading...
Abstract

The Journal of Kerbala University is a refereed scientific Journal which is quarterly issued for the purposes of scientific promotions. It covers various specialties. It was first published in 2003 and gained the international ISSN-1813-0410. The journal annually receives 500 research papers so the number of the published papers amounts to 300 papers and the pending ones amount to 200 papers. The research papers are subject to scientific evaluation by professional panelists and they are published in both Arabic and English languages.The Journal is concerned with:1- Receiving the professors' research papers to be published in the Journal.2- Forwarding the research papers to the evaluating committee of panelists.3- Providing the researchers with a letter of publication acceptance after receiving an approval of publication.4- Setting up the research papers according to the criteria set by Journal.5- Making 50 copies of the special issue of the Journal scientific issue Arabic+ Human studies+ scientific studies in English and Arabic.

أن مجلة رئاسة الجامعة هي مجلة علمية محكمة تصدر بشكل فصلي لأغراض الترقيات العلمية وهي مجلة علمية رصينة في مختلف الاختصاصات تأسست في عام 2003 حاصلة على الترميز الدولي ISSN-1813-0410 تستقبل المجلة بما يقارب 500 بحث في السنة وعليه يبلغ عدد البحوث المنشورة بما يقارب 300 بحث منشور في السنة وبما يقارب 200 بحث قيد النشر وتخضع البحوث المقدمة للتقويم العلمي من قبل أساتذة اختصاصين وتنشر البحوث باللغتين العربية والانكليزية اما أعمال المجلة هي :- 1-استقبال البحوث الخاصة بالسادة التدريسيين الراغبين بنشرها في المجلة .2-عرضها على السادة المقيمين .3-تزويد الباحثين بكتاب قبول نشر بعد حصول الموافقة على النشر .4-تنضيد البحوث وفق السياق الخاص بالمجلة والمرفق نسخة منه طياً .5-استنساخ العدد الخاص بالمجلة بمعدل 50 نسخة لكل مجلد (علمي عربي + علمي انكليزي + انساني )