Experimental investigation of the effect of hot finnedtube position on the heat transfer coefficient

Authors: Musa M. Wais --- Murad S. Sedeeq --- Ehsan F. Abbas
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2017 Volume: 25 Issue: 2 Pages: 685-692
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

In the present study, an experimental investigation is carried out to calculate heat transfer coefficient from the change in position of a finned tube in the cross-flow heat exchanger in two different conditions, which are a constant temperature at 90oC and constant heat flux at 45W/m2. A standard laboratory device (crossflow heat exchanger) was used in experiment process, that which manufactured by EDIBON company. The air flow over finned tubes inside heat exchanger was studied at Reynolds number ranging from 3600 to 11600. The comparative of experiments results between two cases shows that the Nu number in four positions at the constant temperature condition are higher than symmetrical positions in constant heat flux. The results indicated that the position3 gives higher values of Nu number in both cases

تشمل الدراسة الحالية تحليل نتائج اختبارات التي اجريت لحساب قيمة معامل انتقال الحرارة و ثاثيرها بتغير موقع انبوب مزعنف في مبادل حراري متعامد وفي حالتين من التسخين ( ثبوت درجة حرارة 90 مئوية و فيض حراري ثابت 45 واط/م2). حيث اجريت الدراسة في مدى لجريان الهواء تتراوح من 3600 الى 11600 رقم رينولد وذلك من خلال استخدام مبادل حراري مختبري نوع متعامد مجهز من قبل شركة EDIBON المتخصصة في صناعة الاجهزة المختبرية. من خلال مقارنة نتائج للحالتين، تبين بان رقم نسلت عند المواضع الاربعة في حالة ثبوت درجات الحرارة اعلى من مواضع مماثلة عندحالة ثبوت الفيض الحراري ومن مجمل النتائج الاختبارات تبين بان الموضع رقم 3 تعطي اعلى قيم لرقم نسلت للحالتين.


Article
THE INFLUENCE OF AIR DISTRIBUTORS ON HEAT TRANSFER COEFFICIENT IN FLUIDIZED BED OF HEAT PIPE HEAT EXCHANGER

Author: Amer M. Al-Dabagh
Journal: AL-TAQANI مجلة التقني ISSN: 1818653X Year: 2006 Volume: 19 Issue: 2 Pages: 135-149
Publisher: Foundation of technical education هيئة التعليم التقني

Loading...
Loading...
Abstract

Heat exchanger made of heat pipes elements immersed in a fluidized bed represents one of the most economic devices used in recovery of waste heat energy. In the present work ten copper heat pipes (each 22.2mm diameter and 550 mm length), fixed in staggered arrangement with (175mm) static bed height, and (176,353,707μm sand mean particle diameter) were used . Two types of air distributors (bubble cap and perforated plate) were used with an open area of (21.6%, 6.36%, 3.97%). The study covers the air mass velocity from (0.31 to 0.57 Kg/m2 Sec), with hot bed temperature of 160Co. The results show that the overall heat transfer coefficient for the heat exchanger using bubble cap distributor is slightly higher than that for perforated plate, while the power consumption was greater by 30% for bubble cap distributor. Bubble cap distributors pressure drop was 90% greater than perforated plate distributor for the same operating conditions. At the same time , it shown that heat transfer coefficient is increased with open area increase, while opposite response was found for power consumption .

تمثل المبادلات الحرارية ذات الانابيب الحرارية المغمورة في وسط مميع أحدى الوسائل الفعالة لأسترداد الطاقة الضائعة. تناول البحث دراسة انتقال الحرارة في مبادل حراري مصنوع من عشرة أنابيب حرارية نحاسية بطول 550ملم وبقطر 22.2 ملم مغمورا في طبقة مميعة بالغاز ومرتبة بشكل متخالف . مستخدمين ثلاثة اقطار لحبيبات الرمل(176،353،707مايكروميتر) بمعدل أرتفاع للطبقة المميعة 175 ملم. تم حساب معامل انتقال الحرارة مع تغير النسبة المئوية للمساحة المفتوحة للهواء (21.6%،6.36%،3.97%) لنوعين من الموزعات الهواء (مثقب وفقاعي ) .أجريت التجارب عند درجة حرارة 160 مه للطبقة الساخنة ومعدل تدفق هواء ( 0.57 - 0.31 كغم/م2 ثا) . أظهرت النتائج أن معامل انتقال الحرارة للمبادل الذي يستخدم موزع الهواء الفقاعي كانت أكثر من موزع الهواء المثقب، فيما كان معدل استهلاك القدرة أكثر وبنسبة 30% لموزع الهواء الفقاعي . كما أن هبوط الضغط عبر الموزع الفقاعي يصل إلى 90% أكثر من موزع الهواء المثقب تحت نفسها الظروف التشغيلية . واخيراً يمكن القول أن معامل انتقال الحرارة يزداد بزيادة النسبة المئوية للمساحة المفتوحة لموزع الهواء ,بينما يقل معدل استهلاك القدرة .


Article
An Experimental Study to Show the Effect of Time of Opening and Closing the Solenoid Valve on Effectiveness of Finned Cross Flow Heat Exchanger
دراسة عملية لبيان تأثير زمن فتح وغلق الصمام اللولبي على فعالية مبادل حراري مزعنف

Author: سعد سامي فرحان
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2012 Volume: 19 Issue: 3 Pages: 26-35
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

In this research an experimental study was carried out to show the effect of time of opening and closing the solenoid valve on the effectiveness of finned cross flow heat exchanger, which has changed the time of opening and closing the solenoid valve (2, 4, 6 sec.) with change the mass flow rate of water each time and the range values between (0.027-0.0816 kg/s) with constant of mass flow rate of air at (0.032 kg/s). The results obtained from experiment works that the decreasing in the time of opening and closing the solenoid valve from (6 sec.) to (2 sec.) leads to increase internal heat transfer coefficient (hi) the highest increase was by (18.37%) at mass flow rate of water(0.027 kg/s) and increase the overall heat transfer coefficient (U) and the highest percentage of increase (7.36%) at mass flow rate of water (0.027 kg/s). The experimental results obtained show that the increasing both the number of units transmitted (NTU) and effectiveness of the finned heat exchanger when decrease the time of opening and closing the solenoid valve from (6 sec.) to (2 sec.) and the highest percentage of the increase occurring is (8.4%) and (1.74%) respectively at mass flowrate of water (0.027 kg/s).


Article
Heat Transfer Characteristics of a Fluid Flow in Multi Tube Heat Exchanger Fitted with Perforated Fins
خصائص انتقال الحرارة لمائع يجري خلال مبادل حراري متعدد الانابيب مجهز بزعانف مثقبة

Authors: Ayad Dawood Suliman اياد داؤد سليمان --- Dhia Al-Deen Hussain Alwan ضياء الدين حسين علوان --- Nabil Jamil Yasin نبيل جميل ياسين
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2015 Volume: 21 Issue: 11 Pages: 40-59
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The heat transfer and flow resistance characteristics for air flow cross over circular finned tube heat exchanger has been studied numerically and experimentally. The purpose of the study was to improve the heat transfer characteristics of an annular finned-tube heat exchanger for better performance. The study has concentrated on the effect of the number of perforations and perforations shapes on the heat transfer and pressure drop across a staggered finned tube heat exchanger. The Numerical part of present study has been performed using ANSYS Fluent 14.5 using SST Turbulent model, while the experimental study consist from a test rig with different models of heat exchangers and all required measurement devices were building up to cover the experimental work for the range of Reynolds number (7500-17500). The experimental results show that average Nusselt number of the six circular perforations fins model is about 11.08 % higher than that for solid fin model and with triangular perforations model is about 10.12 % higher than that for the solid fin. Triangular perforation finned heat exchanger model gives a best result than the other models due to excessive increment in the )Nu( in comparison with other models take in consideration pressure drop. The results were validated with previous work and the comparison between the experimental and numerical shows a good agreement with a maximum deviation ±10% between them.

تمت دراسة خصائص انتقال الحرارة ومقاومة الجريان للهواء المار عبر مبادل حراري مزعنف نظرياً وتجريبياً. الغرض من هذه الدراسة هو محاولة تحسين خصائص انتقال الحرارة لمنظومة انابيب حلقية الزعانف للحصول على اداء افضل. ركزت الدراسة على معرفة تأثير عدد الثقوب واشكالها على عملية انتقال الحرارة وانخفاض الضغط خلال مبادل حراري من النوع المتخالف الترتيب. في الدراسة النظرية تم انشاء الشبكة باستخدام برنامجANSYS Fluent.14 مع موديل الجريان الاضطرابي SSTبينما تضمن العملي ضمن ال بناء جهازتجريبي يحتوي كافة نماذج المبادل الحراري المصنعة وجميع اجهزة القياس المطلوبة لغرض الدراسة التجريبية ضمن حدود عدد رينولد (7500-17500). اظهرت النتائج التجريبية ان عدد نسلت للزعانف الحاوية على ستة ثقوب دائرية اعلى بحدود 11.08% من الزعانف الغير مثقبة, في حين ان عدد نسلت كان اعلى بمقدار 10.12% للزعانف الحاوية على أربع ثقوب مثلثية عن الزعانف الغير مثقبة. كذلك اظهرت الدراسة ان نتائج الزعانف ذوات الثقوب المثلثة هي الافضل بالمقارنة مع باقي النماذج نظراً للزيادة الملحوضة في عدد نسلت بالاخذ بنظر الاعتبار الزيادة في انخفاض الضغط. تمت مقارنة النتائج النظرية مع بحوث سابقة وكذلك اجريت مقارنة بين النتائج النظرية والتجريبية وقد اظهرت تقارباً مقبولاً بينهما بانحراف لا يتعدى ±10%.


Article
PSO Design an Optimal Fuzzy Controller for Heat Exchanger Temperature

Author: Mohammed Abd Al-Khaliq Al-Tayyar
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2017 Volume: 25 Issue: 2 Pages: 809-817
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

The temperature in numerous chemical, industrial, heating ventilation and air conditioning HVAC applications is a very crucial variable. The temperature in these applications should be under control. This worked signs Fuzzy logic controller FLC for heat exchang system using a new technique. Heat exchang systems are used for transferring heat from a hot field to a cooler field; sotemperature control of outlet fluid is prime importance. The system of heat exchanger is always used for controlling the different temperature between outlet fluid and inlet fluid. Due to difficulty finding the parameters of the smart controller FLC, (Particle swarm optimization technique) have been projected to form the parameters of FLC. PSO is a heuristic method in computational algorithm. The contribution of our work is present PSO as a designer of FLC. The consequences demonstrate the designed controller reach to set point with the shortest time.

إن درجة الحرارة في الكثير من التطبيقات الكيميائية والصناعية فضلا عن تطبيقات تدفئة وتهوية وتبريد الهواء تعد من العوامل البالغة الأهمية وعليه فلابد من أن تكون درجة الحرارة في هذه التطبيقات مسيطر عليها. تم في هذا لبحث تصميم مسيطر ضبابي للمبادلات الحرارية. يتم إستخدام المبادلات الحرارية لنقل الحرارة من المائع الساخن إلى آخر أقل سخونة. إن السيطرة على درجة حرارة المائع الخارج من المبادل الحراري ذات أهمية قصوى. نظراً لصعوبة التعرف على المتغيرات في نظام المسيطر الضبابي، فقد تم اللجوء إلى تقنية جديدة وهي تقنية تحسين سرب الطيور. إن الإسهام الفعلي في هذا البحث هو إستخدام تقنية سرب الطيور كأسلوب تصميمي لنظام المسيطر الضبابي. يعمل المسيطر الذي تم تصميمه على تنظيم درجة حرارة المائع الخارج من المبادل الحراري ضمن القيم المحددة مسبقاً وخلال أقصر وقت ممكن وبغض النظر عن الحمل أو الإضرابات أو الإجهاد وغيرها...


Article
EXPERIMENTAL STUDY OF HEAT TRANSFER ENHANCEMENT BY USING POROUS MEDIA IN DOUBLE TUBE HEAT EXCHANGER
دراسة عمليه لتحسين التبادل الحراري باستخدام وسط مسامي لمبادل حراري مكون من اسطوانتين متحدتي المركز

Authors: Dr. Kifah H . Hilal د.كفاح حامد هلال --- Noor Samir Lafta نور سمير لفته --- Dr.Isbeyeh W. Maid Dr. Kifah H . Hilal ** Noor Samir Lafta د.اصبيح وسمي مايد
Journal: AL-TAQANI مجلة التقني ISSN: 1818653X Year: 2017 Volume: 30 Issue: 1 Pages: E44-E59
Publisher: Foundation of technical education هيئة التعليم التقني

Loading...
Loading...
Abstract

Forced convection heat transfer in counter flow heat exchanger which uses porous media to enhance heat transfer through it, has been investigated experimentally in the present work.Theexperimental work included the design of double pipe heat exchanger with the dimension of (length 1.11m, 0.063 outer pipe diameter and 0.031m inner pipe diameter). Alumina(2.5mm diameter) as a porous media is added in heat exchangerat three case: inner porous tube (IP) , outer porous tube (OP) and inner- outer tubes (IOP) .Cold andhot water are used as working fluid to transfer heat through outer and inner pipe respectively. The experiment are conducted at hot water mass flow rates (0.0166-0.0833 Kg/s),cold water mass flow rates ( 0.05-0.116 Kg/s) ,inlet temperatures of hot water (47, 55ᵒC) andinlet temperatures of cold water(20, 25 ᵒC).The results are obtained for range of Reynolds number to hot water (1144< Re<6241) and cold water (3939البحث الحالي هو دراسة عملية لانتقال الحرارة بالحمل القسري خلال مبادل حراري مملوء بوسط مسامي لتحسين انتقال الحرارة خلاله. تضمن البحث تصميم مبادل حراري من نوع اسطوانتي متحدتي المركز بأبعاده (1.11m طول, قطر الاسطوانة الداخلية 0.031m , وقطر الاسطوانة الخارجية 0.063 m ). أستخدمت كرات من من الالومينا بقطر (2.5mm ) كوسط مسامي في المبادل الحراري بثلاثه حالات: في الاسطوانه الداخليه (IP), في الاسطوانه الخارجيه (OP), في كلا الاسطوانتين(IOP).. تم استعمال الماء البارد والحار كمائع ناقل للحرارة من جانب الاسطوانه الخارجيه والداخلية على التوالي. جرت الدراســـــــة بمعدل تدفق للماء الحـار تتراوح بين (kg/s 0.833 – 0.0166) ومعدل تدفق للماء البارد (kg/s 0.116 – 0.05)و درجه حراره الدخول للماء الحار فهي (47, 55 ᵒC) ودرجه حراره الدخول للماء البارد (25, 20 ᵒC). بينت لنتائج التي تم الحصول عليها هي ضمن رقم رينولد(1144< Re<6241) للماء الحار و(3939


Article
Enhancing Heat Transfer in Tube Heat Exchanger by Inserting Discrete Twisting Tapes with Different Positions
تحسين انتقال الحرارة في مبادل حراري انبوبي بحشر اشرطة ملتوية منفصلة بوضعيات مختلفة

Authors: Nassr Fadhil Hussein نصر فاضل حسين --- Abdulrahman Shakir Mahmood عبد الرحمن شاكر محمود
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2019 Volume: 25 Issue: 8 Pages: 39-51
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Enhancement of heat transfer in the tube heat exchanger is studied experimentally by using discrete twisted tapes. Three different positions were selected for inserting turbulators along tube section (horizontal position by α= 00, inclined position by α= 45 0 and vertical position by α= 900). The space between turbulators was fixed by distributing 5 pieces of these turbulators with pitch ratio PR = (0.44). Also, the factor of constant heat flux was applied as a boundary condition around the tube test section for all experiments of this investigation, while the flow rates were selected as a variable factor (Reynolds number values vary from 5000 to 15000). The results show that using discrete twisted tapes enhances the heat transfer rate by about 60.7-103.7 % compared with plane tube case. Also, inserting turbulators with inclined position offers maximum heat transfer rate by 103.7%.

تحسين انتقال الحرارة في مبادل حراري انبوبي دُرس عملياً باستخدام أشرطة ملتوية منفصلة. أُختيرت ثلاث وضعيات مختلفة لإدخال ادوات الحشر على طول انبوب الاختبار هي (الوضعية الافقية 00 α=, الوضعية المائلة 450 α=والوضعية العمودية 0 α=90). المسافة بين قطع ادوات الحشر ثُبتت بتوزيع 5 قطع من هذه المضطربات بنسبة PR=(0.44). بالإضافة الى ذلك, تم تطبيق فيض حراري ثابت كشرط حدي لكل التجارب في هذا التحقيق, بينما اختيرت معدلات تدفق الجريان كعامل متغير (قيم عدد رينولدز تتراوح بين 5000 الى 15000). أظهرت النتائج بأن استخدام الاشرطة الملتوية المنفصلة تُحسن معدل انتقال الحرارة بنسبة حوالي من 60.7 الى 103.7 % مقارنة مع حالة الانبوب المستوي. اضافة الى ذلك, حشر المضطربات بالوضعية المائلة يعرض اعظم معدل لانتقال الحرارة بنسبة 103.7%.


Article
Entransy dissipation of Shell and Double Concentric Tube Heat Exchanger Calculations and Analysis
حسابات وتحليل منظومة المبادل الحراري ذو القشرة والانابيب المتداخلة المتمركزة باستخدام تبديد الانترانسي

Author: Basma Abbas Abdulmajeed بسمة عباس عبد المجيد
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2015 Volume: 21 Issue: 6 Pages: 1-14
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Shell-and-double concentric tube heat exchanger is one of the new designs that enhance the heat transfer process. Entransy dissipation is a recent development that incorporates thermodynamics in the design and optimization of heat exchangers. In this paper the concept of entransy dissipation is related to the shell-and-double concentric tube heat exchanger for the first time, where the experiments were conducted using hot oil with temperature of 80, 100 and 120°C, flow rate of cold water was 0.667, 1, and 1.334 kg/m3 respectively and the temperature of inlet cold water was 20°C. The entransy dissipation rate due to heat transfer and to fluid friction or pressure drop was studied.

ان المبادل الحراري ذو القشرة والانابيب المتمركزة المتداخلة هو احد التصاميم الجديدة لتفعيل عملية انتقال الحرارة.ان عملية تبديد الانترانسي والتي توظف الثرموداينمك في عملية تصميم المبادلات الحرارية المثلى هو تطبيق حديث. في هذا البحث سوف يتم تطبيق مبادئ الانترانسي على المبادل الحراري الحراري ذو القشرة والانابيب المتمركزة المتداخلة ولاول مرة, حيث تمت دراسة التجارب عند درجة حرارة الزيت الساخن مساوية لـ 80, 100 و120°م و معدل جريان الماء البارد كان 0,667 و1 و1,334 كغم/م3 و درجة حرارة الماء البارد الداخل مساوية لـ 20°م. تمت دراسة معدل تبديد الانترانسي نتيجة انتقال الحرارة والاحتكاك او انخفاض الضغط.


Article
Thermal Characteristics of Closed Wet Cooling Tower Using Different Heat Exchanger Tubes Arrangement
الخصائص الحرارية لبرج تبريد رطب مغلق باستخدام ترتيب مختلف لانابيب المبادل الحراري

Authors: Qasim Saleh Mahdi قاسم صالح مهدي --- Hayder Mohammed Jaffal حيدر محمد جفال
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2016 Volume: 22 Issue: 1 Pages: 140-158
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This paper presents thermal characteristics analysis of a modified Closed Wet Cooling Tower (CWCT) based on heat and mass transfer principles to improve the performance of this tower in Iraq. A prototype of CWCT optimized by added packing was designed, manufactured and tested for cooling capacity of 9 kW. Experiments are conducted to explore the effects of various operational and conformational parameters on the thermal performance. In the test section, spray water temperature and both dry bulb temperature and relative humidity of the air measured at intermediate points of the heat exchanger and packing. Heat exchangers consist of four rows and eight columns for an inline tubes arrangement and six rows and five columns for staggered tubes arrangement. According to experimental data, the inline tubes arrangement has a better thermal performance than the staggered tubes arrangement. The inline tubes arrangement enhanced thermal efficiency more than (7%) compared to the staggered tubes arrangement. Furthermore the effect of added packing to CWCT on thermal performance was significant compared to CWCT without packing. Comparing CWCT with packing, it has been observed that the best performance for the CWCT with packing under heat exchanger. It can be watched that the thermal efficiency for CWCT with packing under heat exchanger and CWCT with packing above heat exchanger approximately (28%) and (16%) higher than that CWCT without packing respectively. This study provides correlations to predict heat and mass transfer considering the influences of operational parameters for both inline and staggered heat exchanger tubes arrangement.

يتناول هذا البحث تحليل الخصائص الحرارية لبرج تبريد مغلق مطوّر وفقاً لمبادئ انتقال الحرارة والكتلة لتحسين أداء هذا البرج في العراق. تم تصميم وتصنيع واختبار نموذج لبرج تبريد رطب مغلق مطوّر بإضافة الحشوات لسعة تبريد (9kW) . أجريت التجارب لبيان تأثيرات المعاملات التشغيلية والتصميمة على الأداء الحراري للبرج. في مقطع الاختبار تم قياس درجة حرارة ماء الرش وكلاً من درجة الحرارة الجافة والرطوبة النسبية للهواء في نقاط متوسطة للمبادل الحراري والحشوة . المبادل الحراري يتكون من أربعة صفوف وثمانية أعمدة للترتيب المتتالي للأنابيب و ستة صفوف وخمسة أعمدة للترتيب المتعاقب للأنابيب.أوضحت النتائج المستحصلة إن الأداء الأفضل للمبادل الحراري هو عند ترتيب الأنابيب المتتالي مقارنة بالترتيب المتعاقب .الترتيب المتتالي للأنابيب يحسن الكفاءة الحرارية بمقدار يزيد على (7%) مقارنة مع الترتيب المتعاقب. علاوة على ذلك فان إضافة الحشوة إلى البرج المغلق له تأثير فعّال على الأداء الحراري للبرج .مقارنة مع برج التبريد المغلق بوجود الحشوة لوحظ أن افضل أداء في حالة إضافة الحشوة اسفل المبادل الحراري .لوحظ إن الكفاءة الحرارية عند إضافة الحشوة اسفل واعلى المبادل الحراري بأفضية تصل إلى نسبة (40%) و(25%) مقارنة مع برج التبريد المغلق بدون إضافة الحشوة على التوالي . زودت هذه الدراسة عدد من العلاقات التجريبية للتنبؤ بمعاملي انتقال الحرارة والكتلة بدلالة للمتغيرات التشغيلية للترتيب المتتالي والمتعاقب لأنابيب المبادل الحراري .


Article
Field Study of Novel Storage Tank of Solar Water Heating System
دراسة ميدانية لخزان جديد مستخدم في منظومة شمسية لتسخين الماء

Authors: Karima Esmail. Amori كريمة أسماعيل عموري --- Jinan Shaker Sherza جنان شاكر شيرزة
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2013 Volume: 19 Issue: 5 Pages: 597-612
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this paper thermo-hydrodynamic characteristics were investigated experimentally for a new type shell-helical coiled tube heat exchanger used as a storage tank of closed loop solar water heater system. Triple concentric helical coils were made of copper tubes of (12.5mm OD and 10mm ID) with coils diameter of (207, 152.2, 97mm) for outer, middle and inner coils respectively. The experiments were carried out during a clear sky days of (March and April 2012). The parameters studied in this work are: history of average temperature of shell side of the storage tank, collector heat gain, heat rejected from coils to shell side of the storage tank, collector efficiency, thermal effectiveness of the heat exchanger )storage tank), and pressure drop. These parameters were studied at four different circulating mass flow rates of (1.8, 3, 6, 9 l/min) and for two consuming modes of supply water namely no withdrawal, and continuous withdrawal of (1 l/min). The results show that stratification temperature in the storage tank is increased for no withdrawal compared with water withdrawal, also the shell side average temperature increases with increased solar time. Collector efficiency is increased with increasing circulation flow rates, also increases with water withdrawn from storage tank. The pressure drop decreases with the increase of solar radiation .

في هذا البحث تم التحقق من المواصفات الحرارية والهيدروديناميكية عمليا لمبادل حراري جديد نوع قشرة-أنبوب ملتف حلزونيا مستخدم كخزان لمنظومة شمسية لتسخين الماء. صنعت ثلاثة ملفات حلزونية متمركزة من أنبوب نحاس ذو قطر خارجي =12.5 ملم وقطر داخلي=10ملم وبقطر ملف خارجي، وسطي، وداخلي (207، 152.2، و 97ملم) على التوالي. أجريت التجارب في أيام صحوة خلال شهري آذار ونيسان من سنة 2012. درست المتغيرات التالية: توزيع معدل درجة الحرارة في ماء قشرة الخزان، الكسب الحراري للمجمع الشمسي، الحرارة المنتقلة من ماء الملف الى ماء القشرة، كفاءة المجمع، الفعالية الحرارية للمبادل الحراري، وهبوط الضغط. تم دراسة هذه المتغيرات عند اربع قيم لمعدل جريان ماء التدوير (1.8، 3، 6، و 9 لتر/دقيقة) ولنموذجي صرف من ماء التجهيز للمستهلك وهما نموذج عدم سحب الماء، والآخر صرف الماء بمعدل 1لتر/دقيقة وبصورة مستمرة. بينت النتائج وجود تراصف حراري أقوى في الخزان في حالة عدم السحب مقارنة بحالة السحب، وان معدل درجة حرارة ماء الخزان تتزايد مع تقدم ساعات النهار. تتزايد كفاءة المجمع الشمسي مع زيادة معدل جريان ماء التدوير، وتزداد في حالة سحب الماء من الخزان عما هو عليه في حالة عدم السحب. يقل هبوط ضغط ماء التدوير مع زيادة قيمة الأشعاع الشمسي عمليا ونظريا".