Article
ManufacturingA Refrigeratorwith Heat Recovery Unit

Author: Mustafa Mohammed Kadhim
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2018 Volume: 26 Issue: 4 Pages: 104-123
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

This study aims to exploite the rejected heating energy from condenser and benefit from it to reheat the foods and other materials.It can also be employed to improve the coefficient of performance of a refrigerator at the same time by using approximately the same consumption electrical energy used to operate the compressor and refrigerator in general. This idea has been implemented by manufacturing ofa refrigerator with using additional part has the same metal and condenser pipe diameters but its surface area does not exceed 40% from total surface area of the condenser and its design as an insulated cabinet from all sides to prevent heat leakage through it and located between the compressor and the condenser. Small electrical fan has been added inside this cabinet to provide a suitable air circulation and a homogenous temperature distribution inside the cabinet space. It is expected that the super heating energy of refrigerant (R134a) which comes out of the compressor would be removed inside this cabinet and this insist to condensate the refrigerant (cooling fluid) with a rate higher than that used in the normal refrigerator only. Three magnetic valves have been used in order to control the refrigerant flow in state of operation the refrigerator only or to gather with heating cabinet.To measure the temperatures at each process of the simple vapor compression refrigeration cycle, nine temperature sensors at input and output of each compressor, condenser and an evaporator in additional to input of cabinet and inside it and on evaporator surface have been provided. Five pressure gages have been used to measure the value of pressure and compare it for the two states of operation. The consumption of electrical energy can be calculated by adding an ammeter and a voltmeter and compare between the consumption energy of both states. The obtained results show that there is an improvement in thecoeffecient of performance in state of operation the refrigerator with heat recovery cabinet by 20% more than that of the operation of refrigerator only. This improvement is due to the reduction in the condenser exit temperature by 4 to 6 C˚, and the super heat removing process in reheating cabinet. The temperature of the cabinet reachs to 60 C˚ which is a sufficient for the food heating. A small amount of refrigerant pressure reduction due to these additions, and its effect on the preformace of the refrigerator may be not considerable.

يهدف هذا البحث الى إستثمار الطاقة الحرارية المفقودة من المكثف والإستفادة منها لغرض تسخين الأغذية والمواد الأخرى وكذلك تحسين معامل أداء الثلاجة في نفس الوقت بإستخدام تقريباً نفس الطاقة الكهربائية المستهلكة لتشغيل الضاغط والثلاجة بصورة عامة. تم تنفيذ هذه الفكرة من خلال تصنيع ثلاجة مع إظافة جزء إظافي يقع مابين الضاغط والمكثف و مكون من نفس معدن المكثف وله نفس قطر الأنابيب وبمساحة سطحية تبلغ حوالي 40% من المساحة الكلية للمكثف, كما أنه صُمم على شكل حاوية معزولة حرارياً لمنع فقدان الحرارة الى الخارج. تم تزويد هذه الحاوية بمروحة كهربائية صغيرة لتدوير الهواء داخلها وتوزيع الحرارة بشكل متجانس. لسيطرة على جريان مائع التبريد R134a تم أستعمال ثلاثة صمامات مغناطيسية لتشغيل الثلاجة وحدها أو مع كابينة التسخين, ولقياس درجة الحرارة عند كل نقطة في دورة التبريد تم إظافة تسع متحسسات لقياس درجة الحرارة عند مدخل ومخرج كل من الضاغط والمكثف والمُبخر وكذلك كابينة التسخين, كما تم إظافة خمسة مقاييس للضغط للمقارنة بين حالتين التشغيل. الطاقة الكهربائية المستهلكة تُقاس من خلال أستخدام مقياس التيار والفولتية. بينت النتائج المستحصلة الى ان هنالك تحسن في معامل الأداء بنسبة 20% في حالة أستخدام كابينة التسخين, حيث ان هذا التحسن ناتج عن إنخفاض درجة حرارة مائع التبريد الخارج من المُكثف بمقدار 4 إلى 6 م˚ وكذلك إزالة حرارة التحميص داخل كابينة التسخين التي تبلغ درجة الحرارة داخلها حوالي 60 م˚. تم ملاحظ نقصان قليل في ضغط مائع التبريد وهذا لايؤثر على أداء الثلاجة.


Article
Simulation Study and Comparison Green Freeze Technology Utilizing with Theory of Different Adsorption Working Pairs of Solar Adsorption Refrigeration
تكنولوجيا التبريد الخضراء محاكاة جھاز التبرید الامتزازي الشمسي ودراسة تأثیر استخدام أزواج أمتزاز مختلفة

Author: Faiza Mahdi Hadi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2012 Volume: 30 Issue: 3 Pages: 84-97
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In this research a study of the theory of six different adsorption pairs to checkand choose the best adsorption pair in terms of adsorption capacity and the effect ofhigh and low temperature on it. It has been shown that the best adsorption pair atthe temperature 25oC is the activated carbon fiber with methanol (ACF +CH3OH). Where the adsorption capacity is = 0.45 ACF x , followed by granulesof activated carbon with methanol (AC + CH3OH) and adsorption capacity is= 0.3 AC x by more than half compared to a pair of activated carbon fibers. Then,four adsorption pairs have been selected for solar adsorption ice maker system anda couple for solar adsorption chiller system. The application of Excel has been usedto solve governing equations and mathematical model of thermal balancesimulation the largest amount of ice produced, the highest coefficient ofperformance for all pairs adsorption mentioned at the best operational temperature,it was found that the activated carbon fiber with methanol, the largest amount ofice produced 2.55kg and the highest coefficient of performance of 0.38 in theadsorption ice maker at operating temperature of generator is (110oC). TheAdsorption chiller for a couple, silica gel with water, the best in terms of impactwith the cooling effect and coefficient of performance of the highest at temperaturerange of (64 -110oC).

تم في هذا البحث أجراء دراسة نظرية لستة ازواج امتزازية مختلفة لمعرفة واختیار أفضلزوج امتزازي من حیث سعة الامتزاز وتأثیر درجة الحرارة العالیة والواطئة علیھا فقد تبین أن25 ھو الیاف الكاربون المنشط مع oC افضل زوج امتزازي عند درجة حرارةويليه حبيبات xACF = حيث كانت السعة الأمتزازية له 0.45 (ACF+CH3OH) الميثانول بما يزيد عن xAC = سعة امتزازه 0.3 (AC+CH3OH) الكاربون المنشط مع الميثانولالنصف مقارنة بزوج الياف الكاربون المنشط . من ثم تم اختيار اربعة ازواج امتزازية لمنظومةوزوجين امتزازيين Solar adsorption ice maker ماكنة صنع الثلج الامتزازية الشمسيةتمت معالجة المعادلات الحاكمة .Solar adsorption chiller لمنظومة المثلج المائي الشمسي.(Excel) والموديل الرياضي للموازنة الحرارية ومحاكاة المنظومتين باستخدام تطبيق الاكسلومن خلال محاكاة المنظومتين تم تقدير اكبر كمية ثلج منتجة وأعلى معامل الأداء لجميع ازواجالامتزاز المذكورة عند افضل درجة حرارة تشغيلية, حيث تبين ان لألياف الكاربون المنشط مع2.55 واعلى معامل أداء 0.38 في ماكنة صنع الثلج kg الميثانول أكبر كمية ثلج منتجة. أما مثلج الماء (110oC) الامتزازية الشمسية عند درجة حرارة تشغيلية لمولد البخار هيفتبين ان لزوج هيلام السيلكا مع الماء افضل Solar adsorption chiller الامتزازي الشمسي(64 -110oC). من حيث التأثير التبريدي مع معامل أداء أعلى ضمن مدى درجات حرارة


Article
Performance Assessment of LiBr-H2O Absorption Chiller for Air Conditioning Purposes
تقييم أداء مثلج ماء امتصاصي يعمل بمحلول )ماء + بروميد الليثيوم (لأغراض تكييف الهواء

Authors: Qusay Rasheed Al-Amir --- Hameed Kadhem Hamzah --- Riyadh S.Al-turaihi
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2017 Volume: 15 Issue: 3 Pages: 160-173
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

The thermodynamic analysis of a 4TR single stage absorption chiller is executed numerically using Engineering Equation Solver (EES) software. In this chiller, water and lithium bromide mixture is used as a working fluid and supplies by hot water from electrical boiler at any temperature. The investigation is done to assess the effect of varying the exit temperatures of the absorber, evaporator, generator, and condenser on the absorption chiller cycle performance. The cycle simulation is based on the operating temperature ranges and fixed parameters which include as follows: evaporating exit temperature within a range of 2-11 °C, generator exit temperature within a range of 80-89°C, condenser exit temperature range from 30 to 48°C, absorber exit temperature range from 20 to 38°C, three magnitudes of effectiveness of heat exchanger (0.6, 0.65 and 0.7), strong solution flow rate 0.05 kg/s. The results depicted that the performance parameters are affected by the operation temperatures of main components and heat exchanger effectiveness

تم اجراء دراسة عددية ببرنامج EES على مثلج ماء امتصاصي بسعة تتراوح 4 طن تثليجي . هذا المثلج يعمل بمحلول ماء و بروميد الليثيوم كمائع تشغيلي ويجهز بالمائع الحار عن طريق غلاية كهربائية. الهدف من هذا البحث, دراسة تاثير تغير درجات الحرارة الخارجة من الماص و المبخر و المولد والمكثف على أداء مثلج الماء. المحاكاة العددية تمت عند معدلات درجات حرارية مختلفة وكانت كالآتي: درجات الحرارة الخارجة من المبخر بين 2 و11°م, درجات الحرارة الخارجة من المولد بين 80 و89°م , درجات الحرارة الخارجة من المكثف بين 30 و 48°م و درجات الحرارة الخارجة من الماص بين 20 و38°م. كذلك تم دراسة تأثير تغير قيم فعالية المبادل الحراري على أداء المثلج وكانت على التوالي 0,6 و 0,65 و0,7. النتائج المستحصلة بينت ان أداء المثلج يتأثر بتغير درجات الحرارة التشغيلية للمكونات الأساسية للنظام بالإضافة الى تأثره مع تغير قيم فعالية المبادل الحراري.