research centers


Search results: Found 11

Listing 1 - 10 of 11 << page
of 2
>>
Sort by

Article
Study the effect of thickness on attenuations coefficient of polystyrene -bentonite Composite
دراسة أثر السمك على معاملات التوهين لمتراكب بولي ستايرين - بنتونايت

Author: Wasan K. Hasan وسن كامل حسن
Journal: Journal of Kufa - physics مجلة الكوفة للفيزياء ISSN: 20775830 Year: 2015 Volume: 7 Issue: 1 Arabic Pages: 8-17
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

Achievement of studying effect the addition ratio of powder from clays Iraqi bentonite (D<75um) treated with temperature (100 ºC) and treated with PVA as filler on polystyrene to dissolved in toluene with the state ratios and temperature degrees (70-80 ºC).The attenuation measurements of X-Ray for the voltage range (20,25,30)KV for the composite polystyrene-bentonite were done by using X-Ray unit with two X-Ray tubes (Cu tube , Eu tube) and G-M counter.The linear attenuation coefficient (µL) were concluded for the voltage range mentioned above through the linear equations of the yield of graphic representation operation between the logarithmic absorption and the sample thickness X(cm) , the mass attenuation coefficient( µm) were also concluded through the graphic relation between the logarithmic absorption and the equivalence thickness of the samples Xm (gm/cm2) such that the slope of the graphic relation represents the attenuation coefficient either linear or mass.The linear relation between the logarithmic absorption of X-Ray with the thickness and equivalent thickness sample were concluded .Inverse relation between the linear and mass attenuation coefficient with X-Ray voltage were also concluded of composite

تمت دراسة اثر اضافة مسحوق من اطيان البنتونايت العراقي (D<75µm) المحمص بدرجة (100 ºC) والمعالج بمادة PVA كمادة مالئة للبولي ستايرين المذاب بالتولوين بنسب معينة وبدرجة حرارة (70-80 ºC) ثم اجريت قياسات التوهين للاشعة السينية لمديات الفولتية (20,25,30)KV لمتراكب البولي ستايرين- بنتونايت وباستخدام وحدة الاشعة السينية مع انبوبتي توليد الاشعة السينية (النحاس واليوربيوم ) ومنظومة كاشف كايكر مولر .تم الحصول على معامل التوهين الخطي (µL)لمديات الفولتية المذكورة انفا من خلال المعادلات الخطية لناتج عملية التمثيل البياني بين لوغاريتم الامتصاصية وسمك النموذج X(cm) وايضا الحصول على معاملات التوهين الكتلي(µm) لنفس مديات الفولتية من خلال العلاقة البيانية بين لوغاريتم الامتصاصية والسمك المكافيء للنماذج Xm(gm/cm2) حيث ان ميل العلاقة البيانية يمثل معامل التوهين سواء كان خطيا ام كتليا .تم تحقيق العلاقة الطردية بين لوغاريتم الامتصاصية للاشعة السينية مع السمك والسمك المكافيء والعلاقة العكسية بين معاملات التوهين الخطية والكتلية للمتراكب مع فولتية توليد الاشعة السينية .


Article
USE OF GAMMA–GAMMA COINCIDENCE TECHNIQUE IN INVESTIGATING GAMMA – RAYS ATTENUATION AT DIFFERENT ENERGIES
استخدام تقنية تطابق كاما – كاما لدراسة توهين اشعة كاما بطاقات مختلفة

Loading...
Loading...
Abstract

A gamma–gamma fast –slow coincidence spectrometer composed of two 3"×3"NaI(Tl) detectors and peripheral electronics is used in investigating some effects on the photo peak after the penetration of gamma –rays from lead. Coincidence measurements are carried out using Na-22 source with selecting the 511 keV gate. Linear and mass attenuation (in cm²/g) coefficients measurements are made using lead sheets with dimensions 10×10 cm. Mass attenuation coefficient was measured for coincidence spectrum at 511 keV and found to be 0.114 and 0.140 for direct spectrum. Also coincidence and direct spectra measurements were carried out using Co-60 source with 1332 and 1173 keV gates. Mass attenuation coefficient at 1173 keV was 0.0460 for coincidence spectrum and 0.0522 for direct spectrum. At 1332 keV the same coefficient was0.0432 for coincidence spectrum and 0.0452 for direct spectrum. Mass attenuation coefficients values from coincidence measurement are lower than those in direct measurement at same energies.

استخدام مطياف كاما – كاما التطابقي السريع – البطئ المكون من كاشفين وميضيينNaI(Tl) كل بحجم3"×3" والوحدات الالكترونية الملحقة لدراسة بعض التأثرات التي تحدث للقمة الضوئية بعد نفوذ اشعة كاما من مادة الرصاص. أجريت القياسات التطابقية باستخدام مصدر Na -22 وباختيار البوابة 511 keV. أجريت قياسات معامل التوهين الخطي والكتلي (بوحدةcm2/g) باستخدام الواح رصاص وبأبعاد10×10 cm. قيس معامل التوهين الكتلي بالطيف التطابقي عند الطاقة511 keVفوجد انه يساوي 0.114 وبالطيف المباشر 0.140. أجريت القياسات التطابقية والمباشرة أيضا باستخدام مصدرCo-60 وللبوابتين(1173, 1332) keV فكان معامل التوهين الكتلي عند الطاقة1173 keV مساويا لـ0.0460 للقياس التطابقي و 0.0522 للقياس المباشر. اما عند الطاقة 1332 keV فكان 0.0432 للقياس التطابقي و 0.0452 للقياس المباشر. ان قيم معاملات التوهين بالقياس التطابقي هي اقل من تلك المسجلة بالقياس المباشر للطاقة نفسها


Article
Using Gamma-Rays to Determine the Homogeneity of Alloy (Al-Mn) Grafted by some Oxides
استخدام أشعة گاما في فحص تجانس سبيكة (Al-Mn) المطعمة ببعض الأكاسيد

Authors: Raad A. Rasool رعد أحمد رسول --- Ahmed K. Muhemeed أحمد خلف محيميد --- Muhsun W. Albadrani محسن وليد البدراني
Journal: Rafidain journal of science مجلة علوم الرافدين ISSN: 16089391 Year: 2014 Volume: 25 Issue: 3A Pages: 65-74
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

This research includes preparing samples of composite materials by using casting sand and hand mixing to disperse particles oxides such as (Al2O3) and (ZnO and (NiO) in the substrate of bases alloy (Al-Mn). We also use a narrow collimated mono-energetic beam of gamma-rays emitted from the decay of 137Cs (0.662 keV) and a gamma spectrometer UCS-20 connected with a NaI(Tl) detector to determine the homogeneity of the materials (Al-Mn), (Al-Mn)+Al2O3,(Al-Mn)+ZnO,(Al-Mn)+NiO. The homogeneity test was determined from the percentage variations between the transmitted energy, the intensity of gamma-rays, and the linear attenuation coefficient at seven positions for each sample and the percentage of the standard deviation. The linear attenuation coefficients for the above samples were determined, the highest average values obtained 0.251 mm-1 for (Al-Mn)+ZnO and the lowest average values obtained 0.151 mm-1 for (Al-Mn)+NiO. It can be seen from the present results that the materials (Al-Mn), (Al-Mn)+Al2O3, (Al-Mn)+ZnO have a good homogeneity as compared with (Al-Mn)+NiO. The linear attenuation coefficient of (Al-Mn)+ZnO sample was higher than its values in some materials used as gamma-radiation protection shields.

يتضمن هذا البحث تحضير مجموعة من المواد المتراكبة بطريقة السباكة الرملية وباستخدام الخلط اليدوي لتشتيت الدقائق الأوكسيدية (Al2O3 ) و (ZnO) و (NiO) في أرضية سبيكة الأساس (Al-Mn). تم استخدام حزمة ضيقة أحادية الطاقة من أشعة گاما المنبعثة من المصدر المشع37Cs (0.662 keV) ومنظومة قياس أشعة گاما UCS-20 المرتبطة مع الكاشف الوميضي NaI(Tl) في فحص تجانس المواد (Al-Mn) و (Al-Mn)+Al2O3 و (Al-Mn)+ZnO و (Al-Mn)+NiO. تم الفحص من خلال النسبة المئوية للفرق بين طاقة أشعة گاما النافذة وشدة الإشعاع الساقط ومعامل التوهين الخطي في سبع مواقع مختلفة من المادة والنسبة المئوية للإنحراف المعياري. تم حساب معامل التوهين الخطي للمواد أعلاه وتبين أن أعلى قيمة لمعدل معامل التوهين الخطي هو0.251 mm-1 لعينات (Al-Mn)+ZnO وأن أقل قيمة لمعدل معامل التوهين الخطي هو0.151 mm-1 لعينات (Al-Mn)+NiO. أظهرت نتائج فحص التجانس إن العينات (Al-Mn) و (Al-Mn)+Al2O3 و (Al-Mn)+ZnO هي أكثر تجانسا من العينة (Al-Mn)+NiO. إن القيمة الحالية لمعامل التوهين الخطي للمادة (Al-Mn)+ZnO هي أعلى من قيمه للعديد من المواد المستخدمة كدروع واقية من أشعة گاما.


Article
Mass attenuation coefficients and Range of β- Particles in Aluminum and Gold: A Comparison study
معاملات التوهين الكتلي والمدى لجسيمات بيتا –β في عنصري المنيوم والذهب: دراسة مقارنة

Loading...
Loading...
Abstract

Beta particle has a huge applications in industry, medicine and research fields. The aim of the present study is to calculate the mass attenuation coefficients (μ / ρ)β_ and the range of Rβ- for negative beta particles within the energy range (0.257-2.25) MeV for 13Al and 79Au respectively. Use the equation of Kisse and Vertes to calculate the mass attenuation coefficient and the Tabata equations to calculate the range of electrons in the same elements. All the equations were adopting by the program (Visual studio professional 2012). The results we obtained were compared with the available experimental one, indicating that they are in good agreement, thus supporting the possibility of applying them to other elements effectively. As for the range it is a function of the negative beta particle energy and then the range in the aluminum is greater than the of the values in gold due to the electronic density of the gold element.

لجسيمات بيتا تطبيقات هائلة في الصناعة – الطب والدراسات البحثية كافة. تهدف هذه الدراسة لحساب معاملات التوهين الكتلي (〖μ/ρ)〗_(β^- ) والمدى Rβ- لجسيمات بيتا السالبة ضمن مدى الطاقة (0.257 – 2.25) مليون الكترون فولت لعنصري المنيوم 13Al والذهب 79Au على التوالي. استخدم معادلة كايس- فيتراس لحساب معامل التوهين الكتلي ومعادلات تاباتا وجماعته لحساب مدى الكترونات في هذه العناصر, حيث تم برمجة المعادلات المذكورة وفق برنامج (Visual studio professional 2012). تم مقارنة النتائج التي حصلنا عليها مع مامتوفر من نتائج عملية, اذ تشير الى ان هناك تطابق جيد مما يدعم امكانية تطبيقها لعناصر اخرى بشكل فعال وخصوصا عند الطاقات الواطئة لجسيم بيتا السالبة. اما بالنسبة للمدى فهو دالة الطاقة جسيم بيتا السالب وقيم المدى في عنصر الالمنيوم هي الاعلى مما هو للذهب بفعل الكثافة الالكترونية للعنصر الاخير.


Article
COMPARISON OF GAMMA–RAYS ATTENUATION MEASURED BY DIRECT AND COINCIDENCE SPECTRA
مقارنة توهين اشعة كاما المقاسة بالطيف المباشر والطيف التطابقي

Authors: Mahmoud A. Elawi محمود احمد عليوي --- KhalafI. Khalil خلف ابراهيم خليل --- , Du´aa K. Hamad دعاء خلف حمد
Journal: Tikrit Journal of Pure Science مجلة تكريت للعلوم الصرفة ISSN: 18131662 Year: 2017 Volume: 22 Issue: 12 Pages: 98-108
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

Measurements of gamma –rays attenuation in lead and iron sheets were carried out using direct spectrum and gamma- gamma fast slow coincidence spectrometer composed of two 3"×3"NaI(Tl) detectors and Na-22 source. Measurements of mass attenuation coefficient at 511keV were carried out and its values (in cm²/g units) for lead from direct spectrum for the cases of without and with using a collimator (1cm diameter and 5 cm length) were 0.12029 and 0.13591and from coincidence spectrum were 0.10721 and 0.10602 respectively. For iron sheets the mass attenuation coefficient values from direct spectrum for the cases of without and with using a collimator were 0.0780 and 0.0766 andfrom coincidence spectrum were 0.0593 and 0.0616 respectively. The present results registered by direct measurement are little lower than the standard values due to making only photoelectric absorption needed for comparison with coincidence results where the latter showed lower values. The build-up factor were also measured as function of thickness using lead and iron sheets and found fluctuating around unity for lead and iron coincidence spectra and iron direct spectrum, whereas its increases gradually for lead direct spectrum for the measured thickness range. The coincidence spectrometer greatly reduces scatteringevents in the measured material, and thus its results somewhat resemble that of direct measurements with using the collimator.

اجريت قياسات توهين اشعة كاما في الواح من الرصاص والحديد بالقياس المباشر وباستخدام مطياف كاما - كاما التطابقي السريع – البطيء المكون من كاشفي 3"×3"NaI(Tl) ومصدر Na-22. اجريت قياسات معامل التوهين الكتلي عند الطاقة 511 keVووجد ان قيمه (بوحدة cm²/g) للرصاص ومن الطيف المباشر ولحالتي بدون مسدد وباستخدام مسدد (قطره 1cm وطوله 5cm) هي 0.12029 و0.13591 ومن الطيف التطابقي هي 0.10721 و 0.10602 على التوالي. ولألواح الحديد كان معامل التوهين الكتلي من الطيف المباشر ولحالتي بدون مسدد وباستخدام مسدد هو 0.0780 و 0.0766 ومن الطيف التطابقي هو 0.0593و0.0616 على التوالي. ىان النتائج المسجلة بالقياس المباشر للدراسة الحالية هي اقل قليلاً من القيم القياسية المعروفة عالمياً لاعتماد قياسنا الامتصاص الكهروضوئي فقط وذلك للمقارنة مع النتائج التطابقية التي أظهرت قيماً أقل. وقيس عامل التراكم دالة للسمك باستخدام الواح الرصاص والحديد ووجد انه يتأرجح تقريباً حول قيمة الواحد لكل من الطيف التطابقي للرصاص والحديد والطيف المباشر للحديد، في حين تزداد قيمته تدريجياً للطيف المباشر للرصاص وذلك لمدى السمك المقاس. ان المطياف التطابقي يختزل كثيراً حوادث الأستطارة بالمادة المقاسة لذلك فنتائج قياسه تشابه نوعا ما القياس المباشر باستخدام المسدد


Article
INVESTIGATION OF GAMMA-RAYSATTENUATION IN METALLIC POWDERS USING GAMMA- GAMMACOINCIDENCE METHOD
دراسة توهين اشعة كاما في مساحيق معدنية بطريقة تطابق كاما- كاما

Authors: Mahmoud A. Elawi1 محمود احمد عليوي1 --- Khalid H. Mahdi2 خالد هادي مهدي2 --- Rasha W. Kleib1 رشا وائل كليب1
Journal: Tikrit Journal of Pure Science مجلة تكريت للعلوم الصرفة ISSN: 18131662 Year: 2017 Volume: 22 Issue: 12 Pages: 109-117
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

Gamma-rays attenuation in metallic powders is investigated using coincidence technique with two 3ʺx3ʺ NaI(Tl) scintillation detectors. Na-22 source isused with 0.4µCi activity and resolving time registered was 6.7 ns. Linear attenuation coefficient (L.A.C) measurements were carried out at 511keV energy for Fe3O4 and ZrSiO4 metallic powders with uniform 100µm grains size and Fe sheets locally available (for comparison) with different thicknesses. The L.A.C values (in cm-1) calculated from direct spectra were 0.2705, 0.2641and 0.6239 for the materials respectively. The L.A.C values calculated from coincidence spectra using net peak area NPA were 0.2363, 0.2152 and 0.6231 and with using gross peak area GA were 0.2092, 0.1974 and 0.5261 respectively. The mass attenuation coefficient M.A.C (in cm²/g) for Fe sheets from direct spectra was 0.0792 and from coincidence spectra was 0.0791 and 0.0660 for NPA and GA respectively. The ratio of L.A.C from coincidence spectrum / L.A.C from direct spectrum were 0.7733, 0.7474 and 0.8432 using GA and 0.8735, 0.8148 and 0,9987 using NPA respectively.

درس توهين اشعة كاما في مساحيق معدنية باستخدام تقنية التطابق وكاشفين وميضيين نوعNaI(Tl) 3"×3". استخدم مصدر Na-22 بفعالية 0.4µCi وسجل الميز الزمني للمطياف مساويا الى 6.7ns. اجريت قياسات معامل التوهين الخطي عند الطاقة 511 keV لمساحيق اوكسيد الحديد Fe3O4 وكبريتات الزركونيوم ZrSiO4 ذات حجم حبيبي منتظم 100µm وكذلك الواح من الحديد Fe المتوفرة محليا ً(للمقارنة) وباسماك مختلفة. ان قيم معامل التوهين الخطي (بوحدةcm-1) المحسوبة من الاطياف المباشرة كانت 0.2705، 0.2641، 0.6239 للمواد المذكورة على التوالي. اما قيم معامل التوهين الخطي المحسوبة من الاطياف التطابقية وباعتماد صافي المساحة تحت القمة NPA فكانت 0.2363، 0.2152، 0.6231 وباعتماد المساحة الكلية للقمة GA فكانت 0.2092،0.1974،0.5261 للمواد على التوالي. وحسب معامل التوهين الكتلي (بوحدة cm²/g) لألواح الحديد من الطيف المباشر فوجد 0.0792 ومن الطيف التطابقي كان 0.0791 و0.0668 لحالتي NPA وGA على التوالي. ان نسبة معامل التوهين الخطي من الطيف التطابقي/ معامل التوهين الخطي من الطيف المباشر كانت 0.7733،0.7474، 0.8432 باعتماد GA و0.8735، 0.8148، 0.9987 باعتماد NPA على التوالي.


Article
Attenuation of Gamma Radiations Emitted From fission Products (90Sr, 60Co) from UO2 Fuel inside PWR reactor
(90Sr, 60Co) توهين إشعاعات كاما المنبعثة من نواتج الانشطار PWR المحترق داخل مفاعل UO من وقود 2

Authors: Wefaa S.Sugab وفاء سالم صكب --- Najim A.Askouri نجم عبد عسكوري --- Ali K.Hasan علي خلف حسن
Journal: Albahir journal مجلة الباهر ISSN: 23125721 Year: 2017 Volume: 5 Issue: 9+10 Pages: 27-35
Publisher: AL-Abbas Holy Shrine العتبة العباسية المقدسة

Loading...
Loading...
Abstract

In this paper, a computer study by a program written in a language )MATLAB( to studyattenuation of gamma- raysproduced by nuclear fission process that occurs ceramic fuelUO2 insidethe burning power plants burning inside power plants that light water, where it was noted that theamount of radiation attenuation emitted from radioactive isotopes less when increasing the thicknessof the material used as a shield and visor, as well as at least increase linear attenuation coefficient ofthe material,)Any the intensity of radiationbe less in the lead of concrete and therefore less of water(.

تم في هذا البحث أجراء دراسة حاسوبية بواسطة برنامج كتب بلغة الماتلاب لدراسة توهين إشعاعات كاما الناتجةالمحترق داخل محطات القدرة التي تعمل بالماء UO من عملية الانشطار النووي التي تحدث للوقود السيراميكي 2الخيف حيث لوحظ أن كمية توهين الاشعة المنبعثة من النظائر المشعة تقل عند زيادة سمك المادة المستعملة كدرعواقي وكذلك تقل عند زيادة معامل التوهين الخطي للمادة ) اي ان شدة الاشعة تكون اقل في الرصاص من الكونكريتوبالتالي اقل من الماء(


Article
Studying the Linear and the Mass Attenuation Coefficient of Gamma Rays for Certain Building Materials used in Iraq
دراسة معامل التوهين الخطي والكتلي لأشعة كاما لبعض مواد البناء المستخدمة في العراق

Authors: Isra' a M. Hassan إسراء محمد حسن --- Laith A. Najim ليث أحمد نجم
Journal: Rafidain journal of science مجلة علوم الرافدين ISSN: 16089391 Year: 2014 Volume: 25 Issue: 3A Pages: 75-85
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

In this research, the photons of gamma rays emitted from radioactive sources (133 Ba, 137Cs,60Co) at energies (81, 356, 662, 1173, 1332) keV respectively have been used to examine the linear and the mass attenuation coefficient of different construction materials using gamma spectrometer UCS-20 which is connected with sodium Iodide activated thallium detector (NaI(Tl)) to express the decrease in the intensity of these photons when they pass through the targeted material by scintillation detector reading. According to the results obtained, it becomes possible to measure the two types of attenuation coefficients, the linear and the mass, as these coefficients are of great importance in studying the impact of these rays on the material and the accounts of the radiation dose in order to achieve the level of security against exposure to radiation and to prevent the dangers resulting from that exposure by designing suitable shields. The chemical composition of the material under discussion has also been studied using the technique of X-rays fluorescence (XRF) by (XRF) device and the results were put in the program (XCOM) to compare the values of attenuation coefficients. Results have shown that (Granite) is one of the best building materials to be used in shielding against gamma rays, whereas the (Thermostone) showed less ability to attenuation because of its too low density and the little concentration of elements of high atomic number of this Material.

أُستخدمت في هذا البحث فوتونات أشعة كاما المنبعثة من المصادر المشعة (60Co Cs, 137 , 133 Ba) بطاقاتkeV (1332, 1173, 662 ,356 ,81) على التوالي لدراسة معاملات التوهين الخطية والكتلية لمواد مختلفة من مواد البناء باستخدام منظومة قياس أشعة كاما UCS-20 المرتبطة بكاشف ايوديد الصوديوم المنشط بالثاليوم (NaI(Tl ))، و يعبر عن التناقص في شدة هذه الفوتونات عندما تمر في مادة الهدف بقراءة الكاشف ألوميضي وفي ضوء النتائج التي حصل عليها أمكن قياس معاملات التوهين الخطية والكتلية لما لهذه المعاملات من أهمية كبيرة في دراسة تأثير هذه الأشعة على المادة وحسابات الجرعة الإشعاعية وتحقيق المستوى الآمن للتعرض الإشعاعي ومنع الخطر الناتج من التعرض للإشعاع من خلال تصميم الدروع المناسبة، كما تم دراسة التركيب الكيميائي للمواد قيد الدراسة باستخدام تقنية فلورة الأشعة السينية (XRF) بواسطة جهاز (XRF) وأدخلت النتائج في برنامج (XCOM) لمقارنة قيم معاملات التوهين. وتبين النتائج أن الكرانيت هو من أفضل مواد البناء لاستخدامه في التدريع ضد أشعة كاما في حين يظهر الثرمستون اقل قدرة على التوهين بسبب كثافته الواطئة جدا وقلة تركيز العناصر ذات العدد الذري الكبير لهذه المادة.


Article
Reinforcing a metal-based composite with a percentage of MgO particale to improve some of its properties and its relationship to conventional heat treatment
تدعيم متراكب ذات أساس معدني بنسب من دقائق أوكسيد المغنسيوم لتحسين بعض من خواصه وعلاقتها بالمعالجة الحرارية التقليدية

Author: Shaymaa M.F. شيماء محمد فياض
Journal: Tikrit Journal of Pure Science مجلة تكريت للعلوم الصرفة ISSN: 18131662 Year: 2017 Volume: 22 Issue: 11 Pages: 71-78
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

This research involved the manufacture of three compounds using powdered metallurgy technology through the reinforcement of the AlNi with addition percentage (40%), (35%) and 30% (MgO) ceramic reinforce phase to compound of A , B and C respectively and thermally treated In the traditional way In order to study the effect of the MgO addition and heat treatment, the mechanical tests (Diametrical compressive strength and hardness) were conducted.In order to determine the possibility of using the models produced for the attenuation of β particles, The linear attenuation coefficient and half thickness were examined for all models, The mechanical properties and the linear attenuation coefficient of all compounds have been improved, It was observed that the effect of the chemical composition was greater on the properties under study. We obtained the value of the compressive compressive strength of C (29) MPa before the a heat treatment, while the same compound had the MPa ( 32) After the heat treatment, in case of change in the addition ratio, we obtained the highest values of the mechanical properties and the linear attenuation coefficient of C, (29) MPa, (39) and (19.6)cm-1 respectively., And the lowest value given to the thickness of half (0.035)cm compared with (0.078) given by the A compound with the lowest mechanical properties and the linear attenuation coefficient (26.5)Mpa, (34.5) and (8.8)cm-1respectively before thermal treatment.

تضمن هذا البحث تصنيع ثلاث مركبات بتقانة ميتالورجيا المساحيق من خلال تدعيم طور الأساس المعدني (AlNi) بنسب أضافة (40%) , (35%) و(30%) من طور التدعيم السيراميكي MgO لتكوين المركبات A,B,C على التوالي ومعالجتها حراريا بالطريقة التقليدية, ولدراسة تأثير نسبة اضافة MgO والتلدين تم اجراء الفحوصات الميكانيكية (مقاومة الانضغاط القطرية والصلادة) ولتحديد امكانية استخدام النماذج المنتجة لغرض توهين جسيمات بيتا تم اجراء فحص معامل التوهين الخطي وسمك النصف لكافة النماذج. تم التوصل الى امكانية تحسن الخواص الميكانيكية ومعامل التوهين الخطي لكافة المركبات بالتلدين, لكن تم ملاحظة ان تأثير التكوين الكيميائي كان أكبر من التلدين على الخواص قيد الدراسة فحصلنا على قيمة مقاومة الانضغاط القطري للمركب C MPa(29) قبل التلدين بينما امتلك نفس المركب القيمة MPa(32) بعد التلدين بنما في حالة تغير نسبة الاضافة حصلنا على اعلى قيم للخواص الميكانيكية ومعامل التوهين الخطي للمركب C وهي MPa(29), (39) وcm-1(19.6) على التوالي, واقل قيمة اعطاها لسمك النصف cm(0.035) بالمقارنة مع القيمة cm (0.078) التي اعطاها المركب A الذي امتلك اقل قيم للخواص الميكانيكية ومعامل التوهين الخطي MPa(26.5) , (34.5) و cm-1(8.8) على التوالي قبل المعالجة الحرارية .


Article
Gamma Ray Attenuation Coefficients for Lead Oxide and Iron Oxide Reinforced In Silicate Glasses as Radiation Shielding Windows
معاملات توهين اشعة كاما في الزجاج المدعم بأوكسيد الرصاص و أوكسيد الحديد كنوافذ للتدريع الأشعاعي

Authors: Abbas J. Al-Saadi عباس جواد السعدي --- Abbas K. Saadon عباس كريم سعدون
Journal: Ibn Al-Haitham Journal For Pure And Applied Science مجلة ابن الهيثم للعلوم الصرفة والتطبيقية ISSN: 16094042/ 25213407 Year: 2014 Volume: 27 Issue: 3 Pages: 201-214
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this work, the mass attenuation coefficient, effective atomic number and half value layer parameters were calculated for silicate (SiO2) mixed with various levels of lead oxide and iron oxide as reinforced materials. SiO2 was used with different concentrations of PbO and Fe2O3 (25, 50 and 75 weight %). The glass system was prepared by the melt-quenching method. The attenuation parameters were calculated at photon energies varying from 1keV to 100MeV using the XCOM program (version 3.1). In addition, the mass attenuation coefficient and half value layer parameters for selected glass samples were experimentally determined at photon energies 0.662 and 1.28 MeV emitted from radioactive sources 137Cs and 22Na respectively in a collimated narrow beam geometry set-up using 2"x2" NaI (Tl)scintillation detector. These values are found to be in agreement with the values computed theoretically. Moreover, these results were also compared with those for the commercial window glass. The effective atomic number ( Zeff ) and half value layer (HVL) results indicate that pbO+SiO2 was better gamma ray attenuation than Fe2O3+SiO2 and commercial window glass. This indicates that PbO+SiO2 glasses can be used as gamma ray shielding in replace of both of them in this energy range.

تم في هذا البحث حساب معامل التوهين الكتلي والعدد الذري المؤثر و سمك النصف لنماذج زجاجية مكونة من اوكسيد السليكون مادة اساس مدعمة باوكسيد الحديد الثلاثي, واوكسيد الرصاص بتراكيز وزنية مختلفة % wt.(25, 50, 75 ) عند مدى واسع من طاقة الفوتون تراوحت من 1keVالى100MeV باستخدام البرنامج العالمي (XCOM) . كذلك حسب معامل التوهين الكتلي وسمك النصف للنماذج عمليا باستخدام حزمة ضيقة من اشعة كاما عند الطاقات0.662 MeV و 1.28MeVالمنبعثة من النظائر المشعة 137Cs و 22Naعلى التوالي. استعمللهذا الغرض الكاشف الوميضي 2"x2" NaI(Tl) فكانت هذه القيم موافقة للقيم النظرية. فضلا عن ذلك قورنت النتائج أيضا مع زجاج النوافذ التجاري. تشير نتائج العدد الذري المؤثر وسمك النصف أن زجاج PbO +SiO2 أفضل توهينا لأشعة كاما من الزجاج Fe2O3+SiO2 , وزجاج النوافذ التجاري وهذا يبين استعمال الزجاج PbO +SiO2 للحماية من أشعة كاما بدل الزجاج Fe2O3+SiO2 وزجاج النوافذ التجاري في هذا المدى من الطاقة.

Listing 1 - 10 of 11 << page
of 2
>>
Sort by
Narrow your search

Resource type

article (11)


Language

Arabic (7)

English (3)

Arabic and English (1)


Year
From To Submit

2018 (1)

2017 (6)

2015 (1)

2014 (3)