Experimental Investigation Effect of Capillary Tube Number on Window Type Air Conditioning Unit Performance
دراسة عملية لتأثير عدد الأنابيب الشعرية على أداء مكييف هواء جداري

Author: Ali Khalid Shaker Al-Sayyab
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2018 Volume: 16 Issue: 1 Pages: 333-341
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

Capillary tubes are widely used in refrigerating and air conditioning units. It has no moving part however, a capillary tube is less expensive and generally performs nearly as well. In this work, the effect of capillary tube numbers on air conditioning system performance is studied for refrigerant R22. The study was adopted with the five capillary tubes at same diameter of 2.2 mm and length of 0.6 m. The experimental work shows that, the air conditioning operates with three capillary tubes gives highest COP from other of the same diameter with 14% increasing from base case of two capillary tubes, where the performance of the air conditioning that operates with one capillary tube gives the lowest COP from other.

تستخدم ألأنابيب الشعرية على نطاق واسع في وحدات التبريد وتكييف الهواء. تمتاز بعدم وجود اي جزء متحرك ويعتبر ألأنبوب الشعري أقل تكلفة .في هذا العمل، تم دراسة تأثير عدد ألأنابيب الشعرية على أداء منظومة تكييف هواء جدارية تعمل بالمائع R22. واعتمدت في هذه الدراسة خمسة أنابيب شعرية ذات قطر 2.2 ملم وطول 0.6 متر. اظهر الجانب العملي أن مكييف الهواء الذي يعمل مع ثلاثة أنابيب شعرية يعطي أعلى معامل اداء من غيرها لنفس القطر مع زيادة 14٪ عن حالة الاساسية (انبوبين شعريين )، كذلك مكييف الهواء الذي يعمل مع أنبوب شعري واحد يعطي أدنى معامل اداء.

Listing 1 - 1 of 1
Sort by
Narrow your search

Resource type

article (1)


Language

English (1)


Year
From To Submit

2018 (1)