research centers


Search results: Found 6

Listing 1 - 6 of 6
Sort by

Article
A study of the Effect of Air Inlet and Exit on Indoor Air Movement
دراسة تأثير مدخل ومخرج الهواء على حركة الهواء داخل غرفه

Loading...
Loading...
Abstract

This work consists of a numerical simulation to predict the velocity and temperature distributions, and an experimental work to visualize the air flow in a room model. The numerical work is based on non-isothermal, incompressible, three dimensional, turbulence model, and solved using a computational fluid dynamic (CFD) approach, involving finite volume technique to solve continuity, momentum and energy equations, that governs the room’s turbulent flow domain. The experimental study was performed using (1/5) scaled room model of the actual dimensions of the room to simulate room air flow and visualize the flow pattern using smoke generated from burnt herbs and collected in a smoke generator to delivered through the prototype room. The numerical results were compared with those obtained from experiments, the correspondence between numerical and experimental was fairly good and also, a fair comparison was found with other workers in this field.

يهدف هذا البحث الى تحسين المعرفة ببعض الوسائل التي يمكن ان تستخدم في حساب توزيع السرع ودرجات الحرارة واظهار هيئه جريان الهواء خلال الفضاء المكيف للغرفه وهذه الخطوه لايمكن الاستغناء عنها عند تصميم انظمة تكييف بنوعيه جيدة. تضمنت الدراسه اجراء محاكاة عدديه لحساب توزيعات السرع ودرجات الحراره وعمل تجريبي لاظهار هيئه جريان الهواء في انموذج الغرفه. المحاكاة العدديه للجريان اعتمدت على انموذج الجريان ثلاثي الابعاد المضطرب غير المنضغط وبدرجات حراره مختلفه وباسلوب المعادلتين واستخدم في الحل احدى طرائق ديناميك الموائع الحسابي. اجريت الدراسه التجريبيه على انموذج مصغر لغرفه صمم ونفذ خلال هذه الدراسه وفق معامل قياس مناسب 15 لمحاكاة جريان الهواء للفضاء الحقيقي (الغرفه) لاظهار هيئه الجريان باستخدام دخان منتج من احتراق حبوب نباتيه يجمع في مولد دخان و يوجه الى انموذج الغرفه. مقارنة النتائج العدديه مع النتائج التجريبيه ومع نتائج باحثين اخرين اظهرت توافق مقبول.


Article
Experimental Study Of Air Flow Rate Effects On Humidification Parameters With Preheating And Dehumidification Process Changing

Author: Ayad Tareq Mustafa
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2011 Volume: 17 Issue: 4 Pages: 979-992
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This research study experimentally the effect of air flow rate on humidification process parameters. Experimental data are obtained from air conditioning study unit T110D. Results obtained from experimental test, calculations and psychometrics software are discussed. The effect of air flow rate on steam humidification process parameters as a part of air-conditioning processes can be explained according to obtained results. Results of the steam humidification processes (1,2) with and without preheating with 5A and 7.5A shows decreasing in dry bulb temperature, humidity ratio, and heat add to moist air with increasing air flow rate, but humidification load, and total energy of moist air increase with increasing air flow rate in the testing tunnel. The steam humidification process (1) with dehumidifying coil shows increase in dry bulb temperature, humidity ratio, humidification load, and heat add to moist air with increasing air flow rate in the testing tunnel, but the total energy decrease as air flow rate increase. These obtained results can be beneficial for controlling comfort air-conditioning processes in buildings.

هذا البحث يدرس تأثير نسبة جريان الهواء عمليا على معاملات عملية الترطيب. البيانات التجريبية تم الحصول عليها من جهاز وحدة دراسة تكييف الهواء T110D. تم مناقشة نتائج الحسابات والبرنامج الحسابي المصردي. تأثير نسبة جريان الهواء على معاملات عملية الترطيب بالبخار يمكن توضيحها في النتائج المستحصلة كجزء من عمليات تكييف الهواء. نتائج الترطيب بالبخار (2,1) مع/ بدون تسخين ابتدائي 5A و7.5A اظهرت نقصان في درجة حرارة البصلة الجافّة, نسبة الترطيب, والحرارة المضافة للهواء الرطب بازدياد نسبة جريان الهواء, ولكن حمل الترطيب والطاقة الكليّة للهواء الرطب تزداد بازدياد نسبة جريان الهواء في قناة الاختبار. عملية الترطيب بالبخار (1) مع وجود ملف سحب الرطوبة اظهرت زيادة في درجة حرارة البصلة الجافّة, نسبة الترطيب, حمل الترطيب, والحرارة المضافة للهواء الرطب بازدياد نسبة جريان الهواء في قناة الاختبار, ولكن نقصان الطاقة الكليّة بازدياد نسبة جريان الهواء. هذه النتائج المستحصلة يمكن الاستفادة منها في نظام سيطرة عمليات تكييف الهواء في الابنية.


Article
Experimental Study of Fluid Flow Through Packed Beds of Glass Sphere Packing
الدراسة العملية لجريان الموائع خلال العمود الحشوي المحشو بجسيمات زجاجية كروية الشكل

Authors: Mohammed N. Latif --- Wekar Abd Al-Wahed --- Zainab Talib Abidzaid
Journal: Thi-Qar University Journal for Engineering Sciences مجلة جامعة ذي قار للعلوم الهندسية ISSN: 20759746 Year: 2012 Volume: 3 Issue: 2 Pages: 32-47
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

Fluid flow through packed bed has many important applications in chemical and other process engineering fields such as fixed-catalytic reactor, adsorption of a solute, gas absorption, combustion, drying, filter bed, wastewater treatment and the flow of crude oil inpetroleum reservoir.The present work presents the study of air flow through a packed bed of glass sphere packing with 0.42, 0.50, 0.61, 0.79 and 1.01 cm in diameter, and the packed column was 7.62 cm in diameter and 57 cm long. Different flow rates of fluid were used which expressed bymodified Reynolds number. Many variables were studied in this work such as fluid type (air flow), flow rate and the packing porosity, in order to study the effect of these variables on the friction factor.Anew correlation for friction factor as a function of Reynolds number for air flow through packed of mono size packing has been made.The results showed that the pressure drop through a packed bed is highly sensitive to the packing porosity which has a significant effect on the friction factor. It was found that as the bed porosity increases the friction factor values as well as the pressure drop values decrease.

جريان الموائع خلال الاعمدة المحشوة لها تطبيقات مهمة في الهندسة الكيمياوية والفروع الهندسية الاخرى، مثل المفاعلات المحفزة والامتزاز من المذاب ، امتصاص الغاز ، والاحتراق ، والتجفيف ، وتصفية السرير ، ومعالجة مياه الصرف الصحي وتدفق النفط الخام في المكامن النفطية.تم في هذا البحث دراسة جريان الهواء خلال عمود حشوي محشو بجسيمات زجاجية كروية الشكل وبأ قطار 0.42, 0.5, 0.61، 0.79 و 1.01 سم، و كان قطر العمود المحشو 7.62 سم و طوله 57 سم. كما استخدمت عدة سرع لمعدل الجريان الموائع و الممثلة بعدد رينولدز. لقد تم دراسة عدة عوامل خلال هذا العمل كنوع المائع (جريان الهواء), سرعة الجريان وتغير مسامية الحشوة لمعرفة تاثير هذه العوامل على معامل الاحتكاك. تم ايجاد علاقة تجريبية جديدة تربط بين معامل الاحتكاك ورقم رينولدز لجريان الهواء خلال العمود الحشوي استناداً على تجاربنا العملية.اثبتت نتائج الدراسة ان هبوط الضغط خلال عمود حشوي يتأثر لدرجة كبيرة بمسامية الحشوة والتي لها تأثير ملموس على معامل الاحتكاك. حيث لوحظ انه عندما تزداد مسامية الحشوة تقل قيم معامل الاحتكاك, وبالتالي تقل قيمة هبوط الضغط.


Article
Experimental Study of Mixed Convection Heat Transfer for a Thermally Developing Air Flow in an Inclined Annulus

Authors: Ahmed J.Shkarah --- Yasin K.Salman
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2005 Volume: 11 Issue: 4 Pages: 683-699
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The investigation-included experiments were conducted to investigate the local and average mixed convection heat transfer coefficient for thermally developing and fully developed hydrodynamically laminar airflow in an inclined annulus. The experimental setup, using an aluminum annulus having a radius ratio of (0.41) and the inner tube with a heated length of (0.85m) with constant wall heat flux boundary conditions. The investigation covered Reynolds number range from (332 to 1128) and heat flux varied from (82w/m2 to 545w/m2). The air is developed hydrodynamically by using the entrance section annulus (calming section) having the same inner and outer diameter as a test section but with variable lengths. The entrance sections included a long calming section with a length of 90 cm (L/Dh =20.93) and short calming section with lengths of 60 cm (L/Dh =13.95). The results obtained represent the temperature distribution along the inner tube surface, the local and average Nusselt number distributions with the dimensionless axial distance (Z+). For all annulus orientations and all entrance sections, the results show an increase in the Nusselt number values as the heat flux increases and as the angle of the inclination moves from the vertical to the horizontal position. A comparison was made between the experimental results and the available previous work of Mataira, D. and Subba Raju, K. (1975), for the local Nusselt number distribution with the dimensionless axial distance (Z+). The results obtained showed a good agreement and has the same trend that obtained in the previous work.

يتضمن هذا البحث إجراء تجارب عملية لبحث معامل انتقال الحرارة الموقعي والمعدل بواسطة الحمل المختلط لجريان المواء الطباقي المتطور حرارياً وتام التطور هيدروداينميكياً في أنبوب حلقي مائل. يتكون الجهاز العملي من أنبوب حلقي مائل نسبة القطر له (0.41) و أنبوب داخلي مسخن و بطول (m0.85) تحت الشرط الحدي بثبوت الفيض الحراري. يتراوح رقم رينولدز في هذا البحث من 332 إلى 1128، وكذلك يتغير الفيض الحراري من (82w/m2 إلى 545w/m2). يكون الهواء تام التطور باستعمال أنابيب مدخل حلقية (أنابيب تهدئة) لها نفس قطر الأنبوب الداخلي والخارجى لجزء الاختبار ولكن بأطوال مختلفة. تتضمن أنابيب المدخل أنبوب طويل بطول (20cm) (L/Dh=20.93) وكذلك أنبوب مدخل قصير بطول (60cm) (L/Dh=13.95). النتائج المستخرجة وضحت توزيع درجة الحرارة على سطح الأنبوب الداخلي، وكذلك تون يع رقم نسلت الموقعي والمعدل مع المسافة المحورية اللابعدية (Z+). لكل زوايا ميل الأنبوب الحلقي و لكل أنبوبي المدخل المستخدمين، بينت النتائج إن قيم رقم نسلت تزداد كلما ازداد الفيض الحراري وكذلك يزداد رقم نسلت كلما زاوية ميل الأنبوب الحلقي تتغير من الموقع العمودي إلى الموقع الأفقي. أجريت مقارنة بين الدراسة العملية والعمل السابق للأدبيات المتوفرة لعمل Mataira, D. and Subba Raju, K. (1975)، لتوزيع رقم نسلت الموقعي مع المسافة المحورية اللابعدية (Z+) حيث أظهرت النتائج موافقة جيدة وتم الحصول على نفس الشكل الذي حصل عليه الباحث.


Article
Designing an Open Circuit Wind Tunnel for Atmospheric Boundary Layers
تصميم نفق رياح ذو دائرة مفتوحة للطبقات الجوية المحاددة

Author: Thaer Obaid Roomi ثائر عبيد رومي
Journal: Diyala Journal For Pure Science مجلة ديالى للعلوم الصرفة ISSN: 83732222 25189255 Year: 2016 Volume: 12 Issue: 3 - part 1 Pages: 12-25
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

A standard, inexpensive open circuit wind tunnel was built to understand and study some applications that related with atmospheric boundary layers, pollution and generate electricity by wind. Its operation, efficiency, and features were tested. Air speed measurements were taken for both sides: inside and outside the tunnel and the air temperatures were measured, as well. Obstacles were put inside the tunnel to observe the air flow patterns. The relationship between the input voltage of fan and the speed of air inside the tunnel was established to calibrate different types of anemometers. Mach number was calculated for the tunnel which was about 0.02. Bernoulli principle was used to find air speed at the end of diffuser section. It was 1.38 m/s, that means this value was close to the observation value (1.5 m/s).

تم بناء نفق رياح قياسي منخفض الكلفة ذو الدائرة المفتوحة لفهم ودراسة بعض التطبيقات المتعلقة بالطبقات المحاددة الجوية والتلوث وتوليد الطاقة الكهربائية بالرياح. تم فحص تشغيله وكفائته وخواصه. فقد تم اخذ قياسات سرع الهواء لكلا الجانبين: داخل وخارج النفق بالاضافة الى قياس درجات حرارة الهواء. كما تم ايضا وضع عوائق داخل النفق لرصد انماط جريان الهواء. اسست علاقة بين الفولتية الداخلة الى المروحة مع سرعة الهواء داخل النفق لمعايرة مختلف اجهزة قياس السرعة. تم احتساب قيمة عدد ماخ للنفق وكانت بحدود 0.02 . استخدمت قاعدة برنولي لإيجاد سرعة الهواء عند نهاية مقطع المشتت وكانت بحدود 1.38m/s ، وهذا يعني بأن القيمة المقاسة كانت قريبة الى القيمة المرصودة (1.5m/s) .


Article
COOLING POULTRY HOUSE BY USING PAD MADE OF PALM RACHIS .
تبريد قاعة الدواجن باستخدام حشوه مصنعه من جريد النخيل .

Author: Ali Mazin Abdul-Munaim علي مازن عبد المنعم
Journal: Diyala Journal of Agricultural Sciences مجلة ديالى للعلوم الزراعية ISSN: 20739524 Year: 2009 Volume: 1 Issue: 2 Pages: 95-103
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

The experiment was conducted at Al- Rashidiya region belong to Baghdad governorate to study the possibility of using Article palm rachis in evaporative cooling unites as a wet pad. Three pad thickness were used with three different levels of exhaust fans including: one, two and three fans in the opposite direction during July and August of 2008 , to measure interior dry bulb temperature, cooling efficiency, interior relative humidity, air suction velocity, and air flow in order to determine which one of them is better in evaporative cooling when that pads are used in poultry house. a factorial experiment with a complete randomized design with three replication was used, the statistical analyses revealed that the pad which constructed from ( 8 ) cm pad thickness with two exhaust fans gave interior dry bulb temperature 28.2 c°, cooling efficiency 81.8 % , relative humidity 73.7%, air suction velocity 0.85 ms ,and air flow 15300 m3hr . The pad that constructed from ( 8 ) cm thickness with two exhaust fans was recommended because it showed the best performance during the experiment.Keywords

تم تنفيذ البحث في منطقة الراشديه ببغداد لدراسة امكانية استخدام مادة جريد النخيل بالتبريد التبخيري .استخدمت ثلاثة اسمك من الحشوه هي 4 و 8 و 12 سم مع عدد من مراوح السحب وهو استخدام مروحه ومروحتين وثلاث مراوح من الجهه المقابله خلال شهري تموز واب 2008 .قيست كل من درجة الحراره الجافه الداخليه م° وكفاءة التبريد % والرطوبه النسبيه الداخليه % وسرعة مقطع الهواء الخارج من الحشوات م/ثا ومعدل تصريف الهواء م3 /ساعه.طبق البحث بتجربه عامليه بالتصميم العشوائي الكامل بثلاث مكررات.ادت التوليفه المتكونه من السمك 8 سم مع استخدام مروحتين للسحب الى الحصول على درجه حراره جافه داخليه 28.8م° وكفاءة تبريد 81.8% ورطوبه نسبيه داخليه 73.7% وسرعة مقطع هواء خارج من الحشوات 0.85 م/ثا وتصريف هواء 15300 م3/ساعه.فيما اعطت التوليفه المتكونه من سمك 8 سم مع استخدام مروحتين للسحب اعلى كفاءة تبريد 81.8% لهذا ينصح باستخدامها لكونها ذات الاداء الافضل طوال مدة التجربه.

Listing 1 - 6 of 6
Sort by
Narrow your search

Resource type

article (6)


Language

English (5)

Arabic (1)


Year
From To Submit

2016 (1)

2014 (1)

2012 (1)

2011 (1)

2009 (1)

More...