A new mode for an on-line determination of Amiloride in pure and pharmaceutical preparation using CFIA with homemade Ayah 3SBGRx3- 3D solar cell microphtometer analyzer
نمط جديد للتقدير الأني للأميلورايد في المستحضرات الصيدلانية والنقية بأستخدام التحليل بالحقن الجرياني المستمر عن طريق استخدام محلل طيفي مايكروي مصنع محليا Ayah 3SBGR x3-3D solar cell.

Authors: Malik H. Alaloosh Alamri مالك حسين العلوش العامري --- Nagam S. TurkieAl-Awadie نغم شاكر تركي العوادي
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2014 Volume: 55 Issue: 3B Pages: 1137-1152
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A new, simple, accurate, fast and sensitive spectrophotometric method has been developed for the analysis of amiloride in pure and pharmaceutical formulations by continuous flow injection analysis. The method was based on the oxidation of the drug with Ce(IV)sulfate in acidic medium to formed a pinkish-red color species which determined using homemade Ayah 3SBGR x3-3D solar cell flow injection photometer. Optimum conditions were obtained using a high intensity green light emitted diode as a source. The linear dynamic range for the instrument response versus amiloride concentration was 0.0005- 10 mmol.L-1 while the L.O.D was of 9.471 ng / sample. The correlation coefficient (r) was 0.9824 while percentage linearity (r2%) was 96.50%. RSD% for the repeatability (n=8) was lower than 1.5% for the determination of amiloride, at concentration of 0.5 mmol.L-1. The method was applied successfully for the determination of amiloride in pharmaceutical preparation. A comparison was made between the newly developed method and the classical method (UV-Vis spectrophotometry at wave length 540nm) of analysis using the standard additions method via the use of paired t-test. It showed that there was no significant difference between the quoted value of each individual company with calculated t-value at 95% confidence interval from developed method, in addition to comparison between two methods and calculate t-value, it was noticed that there no significant difference between two methods at 99% but a significant difference at 95% confidence level.

طورت طريقة طيفية جديدة, بسيطة, سريعة, مظبوطة, وحساسة لتحليل الاميلورايد في صيغته النقية والمستحضرات الصيدلانية بأستخدام التحليل بالحقن الجرياني المستمر. استندت الطريقة على اكسدة العقار بكبريتات السيريوم (VI) في الوسط الحامضي لتكوين اصناف ملونة وردي- محمر والتي قدرت بأستخدام مطياف الحقن الجرياني مع Ayah 3SBGR x3-3D solar cell المصنع محليا. تم دراسة الظروف الفضلى التي تم التوصل اليها بأستخدام ثنائي الوصلة باعث للضوء الاخضر وبشدة عالية كمصدر للتشعيع. كان المدى الخطي الفعال لعلاقة تغير الاستجابة الألية مع تركيز الاميلورايد 0.0005 - 10 مللي مول.لتر-1 بينما حدود الكشف 9.471 نانوغم / انموذج. وان معامل الارتباط (r) 0.9824 بينما نسبة الخطية r2 % = 96.50 % . الانحراف القياسي النسبي المؤي (RSD%) للتكرارية اقل من 1.5 % لمحلول الاميلورايد بتركيز 0.5 مللي مول .لتر-1 (8=n) طبقت الطريقة بنجاح لتقدير الاميلورايد في المستحضرات الصيدلانية . اجريت مقارنة بين الطريقة المطورة والطريقة التقليدية (مطيافية UV-Vis) عند طول موجي 540 نانو متر للتحليل باستخدام منحني الاضافات القياس من خلال استخدام اختبار t- المزدوج. تبين انه لايوجد فرق جوهري بين القيمة الرسمية وقيمة t- المحسوبة من الطريقة المطورة عند فاصل ثقة 95% بالاضافة الى اجراء مقارنة بين الطريقتين وحساب قيمة t- ولوحظ انه لايوجد فرق جوهري بين الطريقتين عند مستوى قناعة 99% وفرق جوهري عند مستوى قناعة 95%.


Article
SIMULTANEOUS DETERMINATION OF AMILORIDE HYDROCHLORIDE AND HYDROCHLOROTHIAZIDE IN PHARMACEUTICALS BY DERIVATIVE SPECTROPHOTOMETRY

Authors: Khaleda, H. Al-Saidi --- Suhad Abdlaziz --- Sahar Semer
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2010 Volume: 13 Issue: 4 Pages: 52-61
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

Method is established for simultaneous determination of Amiloride hydrochloride (Amilo) andhydrochlorothiazide in tablets. The method is based on employing normal and derivativespectrophotometry using the zero order via described by measuring the absorbance at 361 nm andthe first order derivative spectra at peak 340 and valley 382 nm for (Amilo), while the zerocrossingmethod is applied for hydrochlorothiazide. The first order derivative absorption spectra atvalleys 285 and 239 nm were used for hydrochlorothiazide. No interferences found betweenboth determined and those of matrices. A good accuracy and precision of simultaneousdetermination of (Amilo), and hydrochlorothiazide were confirmed by statistical analysis. Thepercentage recovery of the individual drags under the established conditions is ranged from 97.79%to 101.5 %. Linearity is maintained within a wide concentration range from 2.00 mg/L to 40.00mg/L for Amiloride hydrochloride and hydrochlorothiazide. The detection limit was 0.5 and 1.0mg/L for Amiloride hydrochloride and hydrochlorothiazide respectively.


Article
New Mode for the On-Line Determination of Amiloride in Pure and Pharmaceutical Preparation Using CFIA Via the Use of Linear Array from Six LED (Snow White) with One Solar Cell in a Homemade Ayah 6Sx1-T-1D Solar CFI Analyser
نمط جديد للتقدير الاني للاميلورايد في المستحضرات الصيدلانية والنقية باستخدام التحليل بالحقن الجرياني المستمر عن طريق مصفوفة خطية لـ ست ثنائي وصلة باعث للضوء الابيض الثلجي مع خلية شمسية في محلل لقياس التعكرية Ayah 6Sx1-T-1D solar CFI

Author: Issam M.A. Shakir عصام محمد علي شاكر
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2014 Volume: 55 Issue: 4B Pages: 1708-1720
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A newly flow injection-turbidimetric method characterized by it is speed and sensitivity has been developed for the determination of Amiloride in pure and pharmaceutical preparations. It is based on the formation of yellowish white precipitate for the Amiloride-phosphomolybidic acid ion pair in aqueous medium. Turbidity was measured by Ayah 6Sx1-T-1D solar cell CFI analyser via the attenuation of incident light from the surfaces precipitated particles at 0-180. The Chemical and physical parameters were investigated. Linear dynamic range for the attenuation of incident light versus Amiloride concentration was of 0.005-10 mmol.L-1, with the correlation coefficient (r) of 0.9986 , while the percentage linearity (r2%) was 99.71%. The L.O.Q was of 23.14 µg/sample, while L.O.D (S/N=3) =5.74 ng/sample from the stepwise dilution for the minimum concentration in the calibration graph. The R.S.D% at 3, 9 mmol.L-1 Amiloride is less than 0.5% (eight replicates) using 50 µL sample volume. Through put was of 40 sample.hr-1. The method was applied successfully for the determination of Amiloride in pharmaceutical preparations. A comparison was made using the standard additions method via the use paired t-test. It showed that there was no significant difference between the quoted value of each individual paired t-test with calculated t-value at 95% confidence interval from developed method. In addition to comparison between two methods and calculate t-value, it was noticed that there was no significant difference between the two methods at =0.05 (95% confidence level).

طورت طريقة جديدة بالحقن الجرياني لقياس التعكرية وتميزت بالسرعة والحساسية لتقدير الاميلورايد في المستحضرات الصيدلانية والنقية. استندت على تكوين راسب ابيض مصفر للمزدوج الايوني: اميلورايد-حامض موليبدات الفسفوريك في الوسط المائي. تم قياس التعكرية بوساطة محلل الحقن الجرياني المستمرAyah 6Sx1-T-1D solar cell-CFI analyser عن طريق توهين الضوء المسلط من على سطوح دقائق الراسب بزاوية 0-180. تم دراسة الظروف الفضلى من المتغيرات الفيزيائية والكيميائية. المدى الخطي الفعال لعلاقة توهين الضوء الساقط ضد تركيز الاميلورايد 0.005-10 مللي مول.لتر-1 مع معامل ارتباط (r): 0.9986 ونسبة الخطية (r2%)=99.71%. معامل التقدير الكمي (L.O.Q) : 23.14 مكغم/انموذج بينما حد الكشف (S/N=3) L.O.D 5.74 نانوغرام/انموذج من التخفيف التدريجي لاقل تركيز في منحني المعايرة. الانحرافالقياسي النسبي المئوي لتركيز 3 و9 مللي مول.لتر-1 من الاميلورايد اقل من 0.5% (تكرارية لثمان مرات) باستخدام حجم لانموذج محقن 50 مايكرولتر. معدل النمذجة 40 انموذج/ساعة. طبقت الطريقة بنجاح لتقدير الاميلورايد في المستحضرات الصيدلانية. اجريت مقارنة باستخدام منحني الاضافات القياسية و اختبار-t المزدوج ولوحظ عدم وجود فرق جوهري بين القيمة الرسمية للاختبارات الانفرادية وقيمة t-المحسوبة عند فاصل ثقة 95% للطريقة المطورة بالاضافة الى اجراء مقارنة بين الطريقتين ولوحظ عدم وجود فرق جوهري بينها عند =0.05 (مستوى الثقة 95%).