research centers


Search results: Found 8

Listing 1 - 8 of 8
Sort by

Article
IMPROVING OF EFFLUENT SEWAGE BY TREATMENT WITH LOCAL MATERIALS

Loading...
Loading...
Abstract

Natural materials that are available in large quantities or certain waste from agricultural operations may have the potential to be used as low cost adsorbents, as they represent solid waste, widely available and are environmentally friendly after use it. The aim of this research is to evaluate the applicability of using one of these locally available materials (sawdust) to improve the sewage effluent quality.The sawdust, low cost locally available material and solid waste, was tested as biosorbent for the removal of biochemical oxygen demand (BOD5) from effluent sewage. Adsorption of BOD5 onto this low-cost adsorbent was studied by continuous mode system. The effects of initial BOD5 concentration, flow rate, bed height, particle size, activated carbon/sawdust ratios and pH on adsorption capacity were studied. The experiments showed that the adsorption through the sawdust instead of commercial activated carbon was found to be very effective for the removal of BOD5, where the maximum removal percentage reached 86.23%.

المواد الطبيعية المتوفرة بكميات كبيرة او المخلفات من العمليات الزراعية قد تملك الامكانية لاستخدامها كمواد مازة رخيصة الثمن لكونها مخلفات صلبة متوفرة بكميات كبيرة وكونها صديقة للبيئة بعد استخدامها. الهدف من هذا البحث هو تقييم امكانية استخدام واحدة من اهم هذه المواد واكثرها انتشارا ومتوفرة محليا الا وهي نشارة الخشب اذ استخدمت لتحسين نوعية المياه الخارجة من محطات المعالجة.تم اختبار نشارة الخشب التي تعتبر من النفايات الصلبة المنخفض التكلفة والمتاحة محلياً ، كمادة مازة حيوية لإزالة المتطلب الحيوي للأوكسجين (BOD5) من المياه الخارجة من محطات المعالجة. تم دراسة امتزاز BOD5 على هذه المادة المازة منخفضة التكلفة باستخدام نظام الجريان المستمر. تم دراسة تأثير مجموعة من العوامل (تركيز BOD5 الأولى، معدل الجريان، ارتفاع المادة المازة، حجم حبيبات المادة المازة، نسب الكربون المنشط/نشارة الخشب، والأس الهيدروجيني) على سعة الامتزاز. وأظهرت التجارب أن الامتزاز بنشارة الخشب بدلاً من الكربون المنشط التجاري وجد فعالا جداً لإزالة BOD5، حيث بلغت اعلى نسبة مئوية للإزالة 86.23%.


Article
Potential Using of Mixed Microalgae in the Bioremediation of Domestic Effluents
امكانيه استخدام مزيج الطحالب في المعالجه الحيويه لمياه الصرف المنزلي

Author: Aseel Najeeb Ajaweed اسيل نجيب اجاويد
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2016 Volume: 57 Issue: 2A Pages: 838-842
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Microalgae widely used for bioremediation of inorganic (NH4and PO4) nutrients as single isolates. This study aims to use a mix microalgae isolated from Dijlah river for bioremediation of municipal waste water .The experiments had been start with two different concentrations of nutrients. NH4-N values were 23.4 and 31.7mg/l, phosphorus PO4-P 6.7and 10.7 mg/ l and BOD5 were 66 and 83 mg/l. both cycles of treatment showed complete removal for NH 4-N and PO4-P levels after treatment were 1.7 and 0.7 mg/l for both of treatment cycle .Biological oxygen demand reduced to lowest value were18.9 in 2nd cycle while in 1st cycle of treatment reduced to21.3mg/l.The results showed that mix microalgae have the ability to remove nutrients and organic pollutants at different levels even at pH variation during experiment.

استخدمت الطحالب بصوره عامه بشكل عزلات منفرده في معالجه الملوثات اللاعضويه مثل الفوسفات والامونيوم.تهدف الدراسه الحاليه استخدام مزيج من الطحالب المعزوله من نهر دجله في معالجه مياه الصرف المنزلي حيث تم تنفيذ تجارب المعامله الحيويه مرتين لمياه الصرف المنزلي مع اختلاف تركيز الملوثات اللاعضويه في كل مره حيث بلغت قيمتها 23.4و31.7 ملغم لكل لتر للامونيوم اما الفوسفات فكانت قيمها 6.7 و10.7 ملغم / لتر في بدايه التجربه .كذلك تم قياس المتطلب الحيوي للاوكسجين حيث بلغت قيمته66 و83 ملغم / لتر للمحاوله الاولى والثانيه . بينت نتائج الدراسه في المحاوله الاولى والثانيه بان المزيج الطحالب المستخدم كان فعالا في ازاله الامونيوم بنهايه التجربه بينما الفوسفات وصلت الى .71 و0.7 ملغم / لتر.اما المتطلب الحيوي للاوكسجين فقد انخفض الى ادنى قيمه له الى 18.9ملغم / لتر في المعالجه الثانيه ,بينما في المعالجه الاولى تم اختزال المتطلب الحيوي للاوكسجين الى .321 ملغم/لتر.يستنج من ذلك بان مزيج الطحالب كان فعالا في ازاله االملوثات الللاعضويه والتلوث العضوي وبمستويات مختلفه على الرغم من التغاير في قيمه الحموضه في نهايه التجربه .


Article
Seasonal Variations of Some Physio-Chemical Parameters of Al-Auda Marsh in Maysan Province
التغيرات الفصلية لبعض البراميترات الفيزيوكيميائية لهور العودة في محافظة ميسان

Loading...
Loading...
Abstract

Seasonally variations in Physio-chemical parameters of Al-Auda Marsh were investigated from November 2012 to July 2013. In this research examine pH, turbidity, EC, DO, BOD5 and Ca+2, Mg+2, NO2 , NO3 , PO4 , SiO3 ions. Six sites were randomly located and water samples. pH values varied from (7.3 ±0.0) in site 4 during autumn to (8.5±0.5) in site 6 during winter, EC values ranged from (2020±186) μ.s/cm in site 5 during autumn to (6390±875) μ.s/cm in site 6 during summer, mean turbidity data were found to vary from (6.5 ±1.8) NTU in site 4 in summer to (31.0 ±1.6) NTU in site 3 in autumn. DO highest mean value (10.9 ± 0.6) was for site 6 in autumn and the lowest value (6.5±0.9) mg/l for site3 in spring. In case of BOD5 highest and lowest mean values were (4.8 ±0.3) mg/l in site 3 during autumn and (1.2 ±0.3) mg/l in site 2 during winter. Mean Ca+2 ions ranging from (46±9.4) mg/l in site 4 during autumn to (361±19.6) mg/l in site 1 during summer, mean value of Mg+2 ion varied from (18 ±9.5) mg/l in site 5 in autumn to (274 ±44.2) mg/l in summer for site 1. Also, mean PO4-3 values of varying from (0.01±0.0) mg/l in sample of site 6 during winter to (0.3±0.08) mg/l in sample of site 6 during spring. The mean NO3 values was varied from (1.8±0.8) mg/l in site 6 during winter to (6.9 ±0.5) mg/l in site 5 during autumn while in case of NO2 were (0.1±0.0) mg/l in both sites 5 and 6 during spring to (0.35 ±0.01) mg/l in site 1 during autumn. SiO3 data found to vary from (1.0±0.5) mg/l in site 6 during autumn to (6.35 ±0.5) mg/l in site 2 during summer.

درست التغيرات الموسمية للخصائص الفيزيائية – الكيميائية لهور العودة مثل الدالة الحامضية، العكارة ، والتوصيلية الكهربائية ، الاوكسجين المذاب ، المتطلب الحيوي للاوكسجين, أيونات الكالسيوم , المغنيسيوم ، النترات، النتريت ، الفوسفات ، السيلكا. تم اختيار ستة مواقع عشوائيا" ضمن الهور وجمعت عينات المياه للفترة من تشرين الثاني 2012 إلى تموز 2013. معدل قيم pH تباينت من (7.3±0.0) في الموقع 4 خلال الخريف إلى (8.5 ± 0.5) في الموقع 6 في الشتاء, تراوحت قيم EC من(2020 ± 186) μ.s / سم في الموقع 5 خلال الخريف إلى (6390 ± 875) μ.s / سم في الموقع 6 في الصيف. معدل العكارة كان متباين من (6.5 ± 1.8) NTU في الموقع 4 خلال الصيف إلى (31.0 ± 1.6) NTU في الموقع 3 في الخريف. معدل أعلى قيمة للDO ( 10.9 ± 0.6) ملغم / لتر في الموقع 6 خلال الخريف وأقل قيمة ( 6.5 ±0.9 )ملغم / لتر في الموقع 3 خلال الربيع . في حالة BOD5فان معدل أعلى وأدنى القيم كان (4.8 ± 0.3) ملغم / لتر في الموقع 3 خلال الخريف و (1.2 ± 0.3) ملغم / لتر في الموقع 2 خلال الشتاء. معدل ايونات Ca+2 تراوحت من (46 ± 9.4) ملغم / لتر في موقع 4 خلال الخريف إلى(361 ± 19.6) ملغم / لتر في الموقع 1 في الصيف, معدل قيمة ايونات Mg+2تباينت من (18 ± 9.5) ملغم/ لتر في الموقع 5 خلال الخريف إلى (274 ± 44.2) ملغم / لتر في الصيف للموقع 1, كذلك قيمةPO4-3 كانت متفاوتة من(0.01 ± 0.0) ملغم / لتر في عينة الموقع 6 خلال الشتاء إلى(0.3 ± 0.08) ملغم / لتر في عينة الموقع 6 خلال الربيع. وقد تباينت قيم NO3-1 من (1.8 ± 0.8) ملغم / لتر في الموقع 6 خلال الشتاء إلى(6.9 ± 0.5) ملغم / لتر في الموقع 5 خلال الخريف,بينما كانت قيم NO2-من(0.1 ± 0.0) ملغم /لتر في كلا الموقعين 5 و 6 خلال الربيع إلى(0.35 ±1 0.0) ملغم / لتر في الموقع 1 في الخريف و قيم SiO3 كانت مختلفة من(1.0 ± 0.5) ملغم/لتر في الموقع 6 خلال الخريف إلى(6.35 ± 0.5) ملغم / لتر في الموقع 2 خلال الصيف.


Article
Design a Gray Water Treatment System for a Virtual Building Working by Solar Energy

Authors: Kheria M. Essa --- Hashem A. Mahdi --- Mohammed H. Mohammed
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2018 Volume: 36 Issue: 1 Part (C) Pages: 79-85
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This work has showed that gray water can be used in irrigationwith great success. It includes the explanation of how water recycling willsave water for irrigation and agriculture use, reduce the costs ofconstructing purification plants, and add natural filters to the environment.It also aspires to invite companies to reduce the proportion of phosphateand other harmful substances in the composition of soap. In addition, it ispossible to reduce the amount of suspended solids in a gray water byinstalling filters on the washing machines themselves, so that the volume ofproblems in the plankton is reduced at the refineries. It was found that thedecrease in the consumption and rationalization of electric energy wasobserved for other purposes using the solar cell system, which is consideredas a source of power supply system

Keywords

Gray water --- solar energy --- BOD5 --- COD --- TOC --- Oils and fats


Article
Performance Evaluation of Al-Khadraa' Wastewater Treatment Plant, Mosul-Iraq
تقييم أداء محطة الخضراء لمعالجة مياه الصرف الصحي، الموصل- العراق

Authors: Ayad Fadeel Qasim1 أياد فضيل قاسم1 --- Omer Moayad Khalil Al-Obady2 عمر مؤيد خليل العبادي2
Journal: Tikrit Journal of Pure Science مجلة تكريت للعلوم الصرفة ISSN: 18131662 Year: 2018 Volume: 23 Issue: 7 Pages: 42-46
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

The study aims to evaluate the operational efficiency of Al-Khadraa' wastewater treatment plant and the compatibility of the quality of treated water with the Iraqi standards for disposal into rivers and valleys. The study showed that there are large variations in the quantities and quality of the influent to the plant which sometimes lead to stop operational units of the plant and this has an adverse effect upon the plant function. The results showed that the strength of the influent is classified as weak to medium. The average BOD5/COD ratio is equals to 0.6. Also it seemed that the efficiency of the treatment was weak and the quality of the effluent is out of the Iraqi standards for disposal into rivers and valleys. The percentage removal of BOD, COD, TSS, PO4, NH3 were 83.15%, 79%, 69.7%,56.15%,41.88% respectively. The sequence of removal efficiency was in the order of: NH3 تهدف هذه الدراسة إلى تقييم الكفاءة التشغيلية لمحطة معالجة الخضراء ومدى توافق نوعية المياه المعالجة مع المحددات العراقية للطرح في الأنهار والمجاري المائية. تبين من خلال الدراسة أن هنالك تغاير كبير في كميات ونوعية المياه الداخلة إلى المحطة ما يؤدي ذلك إلى إيقاف تشغيل المحطة في بعض الاحيان وانعكاس ذلك سلبا على أداء المعالجة في المحطة. بينت النتائج أن شدة تركيز المياه الداخلة الى المحطة يمكن تصنيفها متوسطة- ضعيفة وان نسبة BOD5/COD تساوي 0.6 , كما أظهرت النتائج أن كفاءة المعالجة في المحطة ضعيفة وأن نوعية المياه المعالجة لا تتطابق مع المحددات العراقية للطرح في الأنهار والمجاري المائية إذ بلغت نسب الإزالة لكل من BOD، COD ،TSS ، PO4، NH3 (83.15%، 79% و69.7%، 56.15%، 41.88%)على التوالي وكفاءة الإزالة كانت على الترتيب NH3


Article
Effects of Discharging Sewage of Baghdad To Tigris River on TheWater Quality
تأثيرات تصريف مياه الصرف الصحي لبغداد الى نهر دجلة على نوعية المياه

Authors: Abbas H. Sulaymon --- Ibtihaj A. Abdul Razzak
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2009 Volume: 27 Issue: 16 Pages: 2903-2917
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Tigris River one of the rivers that suffer from the effect of conservative pollutants. This study include the distribution of pollutants ( which are BOD5, TDS, pH, T.H., SO4 -2, Na+, and turbidity ) in Tigris river between Al-A'imma bridge and Al-Jumhuria bridge ,a reach which is about (9 km) length within Baghdad city; which include four sewage pumping stations untreated discharged to the river.It was conclude that the concentrations of pollutants were increase at the discharge points in the river and exceeding the acceptable limits according to the Iraqi standards specification of surface water , then BOD5 and T.H. became within the acceptable values after (7.8 km ) in the study region , and pH, TDS and Na+ were within the acceptable ranges in all stations in the region, while SO4 -2 was exceed the allowable value (250 ppm) in all of the study region, and for turbidity it was reach to (4.5 NTU) on (8 km) in the study region. At the time of low discharges of Tigris river, sewage pumping stations should set at low discharge rate to decrease the pollutant's concentrations in Tigris river .

ان نهر دجلة يعتبر من الانهار التي تعاني من تأثير الملوثات التي تصرف مباشرة اليه . تم في هذا البحث تطبيق نموذج الخلايا المتعددة لغرض معرفة انتشار الملوثات والمتمثلة في الأس الهيدروجيني ، (TDS) المواد الذائبة الكلية ، (BOD (الاوكسجين الحيوي المطلوب ( 5 SO ايونات الكبريتات ( 4 ، (T.H.) العسرة الكلية ، (pH) ، (Na+) -2 ) ، ايونات الصوديومعلى نوعية مياه نهر دجلة في المنطقة الواقعة بين جسر الأئمة وجسر ( (Tur.) العكورة الجمهورية والممتدة على طول ( 9 كم) ضمن مدينة بغداد ، والتي تحتوي على اربعة محطات للصرف الصحي تصرف مباشرة الى النهر . تم التوصل من خلال النموذج الرياضي الى ان تركيز الملوثات في النهر يزداد خاصة في المناطق التي يتم فيها التصريف مباشرة الى النهر ثم بالانخفاض والعودة الى الحدود المسموحة بعد ( 300 م) من اخر نقطة T.H. BOD يبدأ تركيز 5فأنها كانت ضمن pH, TDS, Na+ صرف اي بعد حوالي ( 7.8 كم) من منطقة الدراسة بينما قيم SO الحدود المقبولة وعلى طول منطقة البحث , في حين ان تراكيز ايونات الكبريتات 4 -2 كانت 0 ) وعلى طول منطقة الدراسة , اما بالنسبة للعكورة ppm) جميعها خارج الحدود المسموحة 4.5 ) بعد ( 8 كم) من بداية منطقة الدراسة , من NTU) فأن قيمتها وصلت الى turbidity الضروري السيطرة على تصاريف محطات الصرف الصحي لجعل تراكيز الملوثات في مياه نهر دجلة ضمن الحدود المسموح بها حيث لوحظ عند تشغيل هذه المحطات بطاقتها القصوى فأنتراكيز الملوثات يزداد خصوصا عندما يكون تصريف نهر دجلة قليل.


Article
Evaluation the efficiency of the plant Hammdan wastewater treatment in the province of Basrah
تقییم كفاءة محطة حمدان لمعالجة میاه الصرف الصحي في محافظة البصرة

Loading...
Loading...
Abstract

studied some physical and chemical factors were in three stations selected from plant Hammdan . The results showed that the average values of the factors studied for pH (7.14, 7.31, 7.57) , total suspended solids TSS (304.04, 253.50, 203.04) mg/l, the values of the biological oxygen demand BOD5 (217.45, 175.41, 97.41) mg/l, the requirement of chemical oxygen demand COD (350.66, 272.50, 182.20) mg/l, sulfates (694.16 , 718.12 , 741.29) mg/l, chlorides (1571.00 , 1743.54 , 1941.87) mg/l, nitrates (13.69 , 17.57 , 21.09) mg/l, phosphate (5.92 , 4.97 , 4.26) mg/l, for three stations respectively . It is clear from these results that the treated water from this station does not conform with the standards of water that can throw it into water bodies .

درست بعض العوامل الفيزيائية والكيميائية في محطة معالجة میاه الصرف الصحي في حمدان - البصرة وبواقع ثلاثة محطات مختارة وأظهرت النتائج إن متوسط قيم العوامل المدروسة لدرجة الأس الهيدروجيني pH (7.14, 7.31 , 7.57) والمواد الصلبة العالقة الكلية TSS (304.04 , 253.50 , 203.04 ) ملغم/لتر, وقيم المتطلب الحيوي للأوكسجين BOD (217.45 , 175.41 , 97.41) ملغم/لتر, والمتطلب الكيميائي للأوكسجين COD (350.66 , 272.50 , 182.20) ملغم/لتر, والكبريتات (694.16 , 718.12 , 741.29) ملغم/لتر, والكلوريدات (1571.00 , 1743.54 , 1941.87) ملغم/لتر, والنترات (13.69 , 17.57 ,21.09) ملغم/لتر, والفوسفات (5.92 ,4.97 ,4.26) ملغم/لتر للمحطات الثلاثة على التوالي . ويتضح من ذلك إن المياه المعالجة من هذه المحطة لا تتطابق مع معايير المياه التي يمكن تصريفها الى المسطحات المائية .

Keywords

Wastewater --- p H --- TSS --- BOD5 --- COD --- SO4 --- NO3 --- PO4. --- مياه الصرف الصحي Wastewater --- pH --- TSS --- BOD --- COD --- SO4 --- Cl --- NO3 --- PO4 .


Article
Assessment Efficiency Evaluation of Al-Diwaniya Sewage Treatment Plant in Iraq
تقييم كفاءة الاداء لمحطة معالجة مياه الصرف الصحي في الديوانية، العراق

Authors: Awatif Soaded Alsaqqar عواطف سؤدد عبدالحميد --- Basim Hussein Khudair باسم حسين خضير --- Ahmid Mekki احمد مكي جبار
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2014 Volume: 20 Issue: 2 Pages: 20-32
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This study aims to evaluate the performance of the sewage treatment plant in Al-Diwaniya, one of cities in the southern part in Iraq. This evaluation could be used to facilitate effluent quality assessment or optimal process control of the plant. The influent reaching the plant is considered a medium to strong in strength with BOD5/COD ratio in the range 0.23 and 0.69 which can be considered an easily degradable sewage by the biological processes performed by the activated sludge unit. The quality of the effluent was found to be higher than the Iraqi standards for disposal to water bodies. The BOD5/COD ratios of the treated sewage varied over a wide range as low of 0.13 to 1.48 indicating operational problems in the plant. Regression analysis was performed to estimate the removal percentages of BOD5, COD, TSS and NO3 that the plant should perform by to reach the disposal limitations.

تهدف هذه الدراسة الى تقييم كفاءة الاداء لمحطة معالجة مياه الصرف الصحي في مدينة الديوانية احدى المدن في جنوب العراق . ويمكن من خلال هذه الدراسة تقييم وتخمين صفات المياه المطروحة او السيطرة المثلى في تشغيل المحطة . و تتغاير مياه الفضلات الداخلة الى المحطة من متوسطة الى عالية القوة وبنسبة طلب الاوكسجين الحيوي الى طلب الاوكسجين الكيمياوي 0,23 و 0,69 والتي تصنف هذه المياه بسهولة التحلل بواسطة الطرق البايولوجية (طريقة الحماة النشطة) . اما االمياه المعالجة من هذه المحطة فقد وجدت بانها لا تتطابق مع معايير المياه التي يمكن رميها الى المسطحات المائية، وان نسبة طلب الاوكسجين الحيوي الى طلب الاوكسجين الكيمياوي للمياه المطروحة من هذه المحطة تراوحت من 0,13 الى 1,48 والتي تؤشر الى وجود مشاكل تشغيلية في المحطة. وقد اجريت تحاليل احصائية لتخمين نسب الازالة للطلب الاوكسجين الحيوي، والاوكسجين الكيميائي و المواد العالقة والنترات بحيث يتم تشغيل المحطة بموجبها للوصول الى المعايير اللازمة لرمي المياه المعالجة الى المصادر المائية.

Listing 1 - 8 of 8
Sort by
Narrow your search

Resource type

article (8)


Language

English (7)

Arabic (1)


Year
From To Submit

2018 (2)

2016 (1)

2014 (3)

2013 (1)

2009 (1)