research centers


Search results: Found 5

Listing 1 - 5 of 5
Sort by

Article
The Effect of Oral Hygiene Status on the Bond Failure Rate of the Orthodontic Bracket

Author: Munad Jihad Ashij AL-Duliamy
Journal: Journal of Oral and Dental Research مجلة طب الفم والاسنان ISSN: 23106417 Year: 2018 Volume: 5 Issue: 2 Pages: 2-12
Publisher: Iraqi Association for Oral Research الجمعية العراقية لبحوث طب الفم

Loading...
Loading...
Abstract

Background Bracket bond failure is one of the major clinical dilemmas in orthodontic specialty that directly affect the success of the orthodontic treatment. Objectives The objectives of the present study were to assess the effect of oral hygiene status of the patients wearing fixed orthodontic appliances on the bond failure rate of thebracket. Materials and Methods Twenty-four patients (14 females, 10 males) with age range (14-25 years) were participants and fixed orthodontic appliances were placed for them. Oral hygiene status was assessed using Orthodontic Plaque Index (OPI) with a score from zero to four. The OPI was evaluated in each patient at follow up visit three-week apart during a six-month observation period. Each bond failure (other than due to trauma) was documented on a data collection sheet remarking the date and tooth type. The effect of OPI scores on the bond failure rate was evaluated. Any relation between the age of the patient, gender, dental arches, sides and tooth type with the deboning behavior was evaluated and the data were analyzed statistically. Results The highest percentage of bond failure rate was apparent with oral hygiene scores three and four. The male and younger patients showed a higher percentage of bond failure. The maxillary arch exhibited a higher percentage of bond failure. Regarding tooth type, both maxillary right lateral incisors and canines had higher percentage of bond failure. Conclusion Maintaining good oral hygiene during the course of orthodontic treatment has a crucial role in the success of bond strength. Bond failure rate varies according to age, gender, dental arch, and tooth type.


Article
Strengthening Of R.C. Beams by External Steel Plate Using Bonded and Unbonded Connectors
تقوية العتبات الخرسانية المسلحة بواسطة الصفائح الحديدية الخارجية بإستخدام الروابط المقيدة وغير المقيدة

Authors: Ashraf A. Alfeehan --- Rana H. Alkerwei
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 1 Part (A) Engineering Pages: 90-100
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Structural rehabilitation represents an important aspect of the construction industry and its significance is increasing. Strengthening is the process of increasing of the existing capacity of a non-damaged structure or a structural component to a specified level. The main aim of this work is to compare the strengthening techniques by bonded and unbounded mechanical connection as well as studying of replacing internal tension bars by external steel plate with the traditional method of bonding by glues on ultimate strength of RC beams. The traditional method use the epoxy glues for interfaces bonding while the idea of these techniques is a connection of external steel plate with RC beams by shear connectors mechanically. The experimental work involves flexural testing of six concrete beams of 100 150 1500mm. The test variable includes the percentage of replacing the internal reinforcement with external steel plate. Comparison of methods of bonded and unbounded beam is implemented with the method of strengthening by glue. Results show that beams reinforced with external steel plate behave as a composite action right up to ultimate load and the mode of failure occurs by yielding of external plate, pullout or yielding the shear connectors not by separation of plate. Using of external steel plate restrains central deflection in the beam with increasing of load capacity by increasing thickness of plates.

يمثل تأهيل وتقوية المنشآت مبدأ مهما في مجال الصناعة الإنشائية و تزداد أهميته بسبب حاجة الأبنية لأعمال التقوية والصيانة. تقوية المنشآت هي زيادة لقابلية تحمل المنشأ أو العناصر الإنشائية غير المتضررة لمستوى معين. الهدف الرئيسي لهذا البحث دراسة عملية ونظرية ومقارنة لطرق ربط الصفائح الفولاذية والعتبات الكونكريتية وإستبدال التسليح الداخلي بالتسليح الخارجي بإستخدام روابط القص المقيدة وغير المقيدة بطريقة ميكانيكية تختلف عن الأسلوب التقليدي في ربط الصفائح الخارجية بسطح العتبة الخرسانية باستعمال المواد الأيبوكسية اللاصقة. تتضمن هذه الدراسة فحص الانثناء لست عتبات خرسا نية (100 150 1500ملم) للتحقق من تأثير زيادة سمك الصفيحة وتأثير نسبة استبدال التسليح الداخلي بالصفيحة الفولاذية الخارجية ونوع الربط. أظهرت نتائج هذه الدراسة انه باستخدام أسلوب الربط الميكانيكي بين العتبة الخرسانية و الصفيحة الفولاذية يتصرف العنصر الإنشائي كوحدة واحدة الى حد الحمل الأقصى ويكون طور الفشل بخضوع حديد الصفائح الخارجية أو سحب وخضوع روابط القص ولا يحدث عزل بين العتبة والصفيحة إطلاقا. استخدام الصفائح الفولاذية كحديد تسليح خارجي أظهر تقييد في الإزاحات المقاسة في مركز العتبة وأدت الزيادة في سمك الصفيحة الى زيادة في قابلية تحمل المقطع


Article
Assessment of Enamel Surface after Debonding of Different Types of Esthetic Brackets (An In Vitro Study)

Authors: Ghaith M. Hasan غيث حسن --- Dhiaa J. N. Al-Dabagh ضياء جعفر الدباغ
Journal: Journal of baghdad college of dentistry مجلة كلية طب الاسنان بغداد ISSN: 16800087 Year: 2016 Volume: 28 Issue: 4 Pages: 162-167
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Background: Debonding orthodontic brackets and removal of residual bonding material from the enamel surface include critical steps that may cause enamel damage. The aim of the present study was to evaluate and compare the site of bond failure and enamel surface damage after debonding of three types of esthetic brackets (composite, ceramic, sapphire) bonded with light cure composite and resin-modified glass ionomer adhesive.Materials and methods: Seventy two maxillary premolars teeth were divided into three groups each group consisted of 24 teeth according to the type of brackets. Each group was subdivided into two subgroups (12 teeth for each) according to the bonding material that was used. After 7 days of bonding procedure, the brackets were debonded using specifically designed debonding device in which the brackets were debonded by a debonding pliers to simulate the actual clinical debonding procedure. Instron Universal testing was used to apply the debonding force on the debonding pliers which transferred to the bracket. The teeth and the brackets were examined with a 10X magnifying lens to evaluate the site of failure. After the removal of residual adhesive, stereomicroscope was used to evaluate enamel surface damage.Results: The most common type of bond failure was cohesive failure (Score II) in all esthetic brackets. While enamel cracks (scale I) were found to be the most type of enamel damage. Chi- square showed non-significant differences among different types of esthetic bracket bonded with same type of adhesive and between the same types of brackets (ceramic, sapphire) bonded with the two types of adhesive. On the other hand, there was significant difference between composite brackets subgroups bonded with the two adhesives.Conclusion: The bond failure mostly within the adhesive itself and higher enamel damage was resulted from mechanical debonding of these esthetic brackets.


Article
Replacing of Internal Tension Bars by External Bonded Plate
ازاحة قضبان الشد الداخلية بصفائح رابطة خارجية

Authors: Dina Mukheef Hamza دينا مخيف حمزة --- Rana Hashim Ghedan رنا هاشم غيدان --- Awadh E. Ajeel عوض عويد عجيل
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2011 Volume: 15 Issue: 3 Pages: 91-103
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

AbstractThis paper presents comprehensive test data on the effect of replacing internal tension bars by externally bonded steel plate at beam tension face on its cracking pattern, structural deformations and ultimate strength of concrete beams reinforced with external. The experimental work include flexural testing of 100 150 1500mm concrete beams divided into two groups to investigate the mutual action of increasing the plate thickness against its width and vice versa. The test variable included the amount of conventional (internal) reinforcement, percentage of replacing the internal reinforcement with external steel plate and the dimensions of plate. Provided the adhesive layer are chosen carefully and proper gluing techniques are followed The results show that beams reinforced with external steel plate show beam action and composite behavior right up to failure and can be used successfully instead of internal reinforcement of a replacement ratios of removed bars to the original tension bars equal to 33% and 67% in which the steel plates used of wider and thiner than other used plates. There is, however, a limitation to plate thickness beyond which shear/bond failure occurs without the beams achieving their full flexural strength (premature failure).

يقدم هذا البحث دراسة عملية على تأثير استبدال تسليح الشد الداخلي بصفيحة فولاذية خارجية على التشقق , التشوهات الإنشائية و المقاومة القصوى لها. تتضمن هذه الدراسة فحص الانثناء لعتبات خرسا نية (100 150 1500ملم) مقسمة الى مجموعتين للتحقق من التأثير المتبادل لزيادة سمك الصفيحة مع العرض. متغيرات البحث تشمل كمية التسليح الداخلي , نسبة استبدال التسليح الداخلي بالصفيحة الفولاذية الخارجية و أبعاد الصفيحة المستخدمة. حيث أظهرت نتائج هذه الدراسة انه بتوفير الربط المناسب بين سطح الخرسانة و الصفيحة الفولاذية يمكن استخدام هذه الصفائح بنجاح بدلا من التسليح الداخلي التي بها نسبة الاستبدال للحديد المرفوع الى الحديد الاصلي مساوي الى 33% و 67% والتي بها الصفائح اعرض و انحف من بقية الصفائح المستخدمةفي النماذج الاخرى لذلك لابد من ضرورة تحديد سمك الصفيحة المناسب لمنع حدوث فشل في منطقة ارتباط الصفيحة بالوجه الخرساني قبل الوصول للمقاومة القصوى للعتبة.


Article
Strengthening Of R.C. Beams By External Steel Plate Using Mechanical Connection Technique
تقوية العتبات الخرسانية المسلحة بواسطة الصفائح الحديدية الخارجية باستخدام تقنية الربط الميكانيكي

Author: Ashraf A. Alfeehan اشرف عبد الهادي الفيحان
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2014 Volume: 18 Issue: 2 Pages: 202-215
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The volume of the infrastructure that needs upgrading, strengthening and/or repair is growing worldwide. A strengthen method that was used quite extensively during the mid 1970s is steel Plate Bonding, this method has gained renaissance in the last decades. This paper presents experimental test data with theoretical analyses on the effect of replacing internal tension bars by externally steel plate on its cracking pattern, structural deformations and ultimate strength of concrete beams reinforced with external using mechanical connection technique. The traditional method use the epoxy glues for interfaces bonding while the idea of this new technique is connection the internal shear reinforcement with the external steel plate mechanically. The experimental work includes flexural testing of 100 150 1500mm concrete beams. The test variable included the percentage of replacing the internal reinforcement with external steel plate. Theoretical analyses implemented by ANSYS finite element program for all beams also presented. The results show that beams reinforced with external steel plate behave as a composite action right up to ultimate load and the mode of failure occurs by yielding of external plate not by separation of plate. Replacing the internal by external steel restrains the central deflection with considerable increasing of ultimate moment capacity. The ratio of steel replacement with 33%, 67% and 100% leads to deflection drop with 12.5%, 7.7% and 4.6% respectively. Results show good agreement between the experimental and theoretical output data.

لا يزال حجم منشآت البنى التحتية والفوقية بحاجة مستمرة ومتزايدة لإعادة التأهيل وإجراءات التقوية والصيانة مع مرور الوقت وتعتبر طريقة تقوية العتبات الخرسانية المسلحة بصفائح فولاذية خارجية من الطرق الشائعة بالرغم من بعض العيوب. يقدم هذا البحث دراسة عملية ونظرية على تأثير استبدال تسليح الشد الداخلي بصفائح فولاذية خارجية على التشقق , التشوهات الإنشائية و المقاومة القصوى لها وذلك باستخدام تقنية جديدة عن طريق ربط حديد القص الداخلي بالصفائح الخارجية بطريقة ميكانيكية تختلف عن الأسلوب التقليدي في ربط الصفائح الخارجية بسطح العتبة الخرسانية باستعمال المواد الأيبوكسية اللاصقة. تتضمن هذه الدراسة فحص الانثناء لأربع عتبات خرسا نية (100 150 1500ملم) للتحقق من تأثير زيادة سمك الصفيحة وتأثير نسبة استبدال التسليح الداخلي بالصفيحة الفولاذية الخارجية.تم إجراء التحليل النظري لهذه العتبات باستخدام برنامج العناصر المحددة ANSYS . أظهرت نتائج هذه الدراسة انه باستخدام أسلوب الربط الميكانيكي بين العتبة الخرسانية و الصفيحة الفولاذية يتصرف العنصر الإنشائي كوحدة واحدة الى حد الحمل الأقصى ويكون طور الفشل بخضوع حديد الصفائح الخارجية ولا يحدث عزل بين العتبة والصفيحة إطلاقا. استخدام الصفائح الفولاذية كحديد تسليح خارجي أظهر تقييد في الإزاحات المقاسة في مركز العتبة وأدت الزيادة في سمك الصفيحة الى زيادة في قابلية تحمل المقطع. إن نسب استبدال حديد التسليح الداخلي 33% ,67% و 100% أدت الى نقصان في الهطول بنسب 12.5%, 7.7% و 4.6% على التوالي وأظهرت الدراسة تقارب جيد بين النتائج العملية والنظرية.

Listing 1 - 5 of 5
Sort by
Narrow your search

Resource type

article (5)


Language

Arabic and English (2)

English (2)


Year
From To Submit

2018 (1)

2016 (1)

2015 (1)

2014 (1)

2011 (1)