research centers


Search results: Found 20

Listing 1 - 10 of 20 << page
of 2
>>
Sort by

Article
STATIC CALIBRATION OF TRIAXIAL ACCELEROMETER USING NONLINEAR NUMERICAL METHOD
معايرة مقياس التعجيل ثلاثي المحاور في الوضع الثابت بأستخدام طريقة عددية غير خطية

Loading...
Loading...
Abstract

Triaxial accelerometers are used in various applications, such as inertial navigation systems (INSs) and inclinometers. Such accelerometers must be calibrated as accurately as possible because accelerometers with even small biases could result in a very fast position drift when they are used for INS applications and could result in inaccurate tilt angle measurements. Since the calibration parameters of a triaxial accelerometer vary under different environmental conditions, including temperature change, the gain factors and biases change whenever the sensor is switched on. Thus, an accelerometer must be calibrated before use or when the temperature is significantly changed. This paper presents a triaxial accelerometer calibration method using a mathematical model of nine calibration parameters: three gain factors, three biases and three non orthogonality factors. The fundamental principle of the proposed calibration method is that the sum of the triaxial accelerometer outputs is equal to the gravity vector when the accelerometer is stationary. The proposed method requires the triaxial accelerometer to be placed in forty eight tilt angles to estimate the nine calibration parameters. Since the mathematical model of the calibration parameters is nonlinear, an iterative method is used Levenberg-marquardt algorithm (LMA). The results are verified by comparing the estimated data and corrected data with how far or close from surface of sphere that have radius 1g and center (0,0,0) by calculating the standard deviation.

تستخدم اجهزة قياس التعجيل ثلاثي المحاور في مختلف التطبيقات، مثل نظم الملاحة بالقصور الذاتي وحساب الميل. قبل استخدام هذه الاجهزه يجب معايرتها بسبب وجود التحيز، حتى القيم الصغيرة يمكن أن تؤدي إلى الانجراف بشكل سريع جدا عندما يتم استخدامها لتطبيقات الملاحة يمكن أن يؤدي إلى قياسات غير دقيقة في زاوية الميل(كما في اجهزة المساحة الالكترونية). معاملات المعايرة لمقياس التعجيل الثلاثي المحاور تتغير بسبب تغير الظروف، بما في ذلك تغير درجة الحرارة، ووضعية الخزن لمده طويله حيث تتغير معاملات المعايرة كلما تم تشغيل جهاز استشعار. وبالتالي، يجب معايرة الاجهزة قبل الاستخدام أو عند تغيير كبير في درجة الحرارة. يقدم هذا المقال طريقة معايرة باستخدام نموذج رياضي من تسعة معاملات معايرة: ثلاثة عوامل للكسب و ثلاثة للتحيز وثلاثة عوامل لعدم التعامد. المبدأ الأساسي لطريقة المعايرة المقترح هو أن مجموع المخرجات لمقياس التعجيل يساوي متجه الجاذبية في حالة الوضعية الساكنة. تتطلب الطريقة المقترحة ان يوضع جهاز قياس التعجيل في ثمان وأربعين زاوية مختلفة لحساب معاملات المعايرة التسعة. بما ان النموذج الرياضي لمعاملات المعايرة هو غير خطي، يتم استخدام أسلوب التكرار (LMA). بعد ذلك يتم التحقق من النتائج بمقارنة البيانات المقاسة من جهاز الاستشعار مع البيانات المصححة و مدى قربها من سطح الكرة التي نصف قطرها (1g) ومركزها (0,0,0) باحتساب الانحراف المعياري.

Keywords

MEMS --- Accelerometer --- calibration --- LMA.


Article
The Accuracy of Blood Pressure Device

Authors: Najla Ayoub --- Hana Alsaeed --- Lamya Ayoub
Journal: Mustansiriya Medical Journal مجلة المستنصرية الطبية ISSN: 20701128 22274081 Year: 2012 Volume: 11 Issue: 1 Pages: 24-26
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Background: One of the factors affecting the accuracy of readings of blood pressure is the equipment used. Defects or inaccuracy of the sphygmomanometer may be source of error in blood pressure measurement. Aims: This study had two objectives. Firstly, to assess the accuracy of sphygmomanometer used in general practice and secondly to assess the physical condition. Materials and Methods: A total of 50 mercury and aneroid sphygmomanometers were tested for accuracy and physical condition. Results: The results were that of the mercury and aneroid sphygmomanometers tested, 30% were inaccurate, of these, 10% recorded an error greater than 10 mmHg. Both types of sphygmomanometers were evaluated for conditions of cuff/bladder, pump bulb, and valve. Air leaks / holes in the pump bulb was found in 4% and bladder damage in 6% and indicator needles not pointing to the zero. Conclusions: It is necessary that all equipment used for blood pressure measurement should be checked for accuracy on regular period.


Article
Calibration of ionization chamber survey meter
معايرة جهاز القياس الإشعاعي (غرفة التأين)

Authors: Ali Kareem Kadhim علي كريم كاظم --- Taiman Bin Kadni تايمان بن كادني
Journal: Iraqi Journal of Physics المجلة العراقية للفيزياء ISSN: 20704003 Year: 2016 Volume: 14 Issue: 29 Pages: 198-208
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Radiation measuring devices need to process calibration which lose their sensitivity and the extent of the response and the amount of stability under a changing conditions from time to time and this period depends on the nature and use of field in which used devices. A comparison study was done to a (451P)(ionization chamber survey meter) and this showed the variation of calibration factor in five different years. This study also displayed the concept of radiation instrument calibration and necessity of every year calibration of them.In this project we used the five years calibration data for ionization chamber survey meter model Inspector (451P) to get that the values of Calibration Factor (CF) and Response (1/CF). The value deviation (Δ%) of CFs for four years of calibration in comparison of CF for the year 2007 are very high and the device under research is not good to use in field and reliable because the ionization chamber is very sensitive to humidity and must calibrate ayearor less, or during every two years and must maintain carefully to reduce the discarded effects to the measurements.

تحتاج أجهزة القياس الإشعاعي الى عملية معايرة والتي تفقد حساسيتها ومدى إستجابتها للقياس ومقدار كفائتها في الظروف المتغيرة بين فترة وأخرى وهذه الفترة تعتمد على طبيعة الاستخدام واﻟﻤﺠال المستخدمة فيه هذه الأجهزة. حيث تم إجراء دراسة المقارنة هذه لجهاز القياس الإشعاعي (451P)(حجرة التأين) وأظهرت الإختلاف لعامل المعايرة خلال خمس سنوات وكذلك بينت هذه الدراسة مفهوم معايرة جهاز القياس الإشعاعي وضرورة إجرائها. في هذا البحث تم إستخدام قراءات المعايرة لجهاز القياس الإشعاعي (451P)(حجرة التأين) وحصلنا على قيم عامل المعايرة والإستجابة. وإن نسبة الإنحراف(Δ%)عند مقارنة عوامل المعايرة للسنوات الأربعة (2010, 2011, 2012, 2013) مع عامل معايرة السنة (2007) نجدها مرتفعة جدا وبذلك فالجهاز غير موثوق به للعمل والقياس, ذلك بسبب ان كاشف حجرة التأين حساس جدا للرطوبة ويجب معايرته سنويا أو اقل أو خلال كل سنتين والمحافظة عليه للحد من الآثار السلبية المحتملة على القياسات.


Article
Radiation doses assessment for workers on radiation measuring devices response check in RNSD laboratories
تقييم الجرع الاشعاعية للعاملين على فحص استجابة أجهزة القياس الاشعاعي في مختبرات مديرية السلامة الاشعاعية والنووية

Authors: Abbas N. Mohammed عباس نعمة محمد --- Zaki A. Mansoor زكي عبد الجبار منصور --- Zainab M. Jbara زينب موسى جباره
Journal: Iraqi Journal of Physics المجلة العراقية للفيزياء ISSN: 20704003 Year: 2019 Volume: 17 Issue: 40 Pages: 42-49
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Radiation measuring devices need to periodic calibration process to examine their sensitivity and the extent of the response. This study is used to evaluate the radiation doses of the workers in the laboratories of the Directorate of Safety as a result of the use of point sources in calibrating of the devices in two ways, the first is the direct measurement by the FAG device and the others using RESRAD and RAD PRO programs. The total doses values using FAG were (2.57 µSv/y, 102.3 µSv/y and 20.75 µSv/y for TLD laboratory, Gamma spectroscopy analyses (GSA) laboratory and equipment store respectively, and the total doses that calculated using RESRAD and RAD PRO were 1.518 µSv/y, 76.65 µSv/y and 21.2 µSv/y for the above laboratories. the dose rate is very low compare with the national, international dose rate limits (20 mSv/y).

تحتاج اجهزة القياس الاشعاعي الى عملية معايرة دورية يتم من خلالها فحص حساسية ومدى استجابة هذه الأجهزة. تمت في هذه الدراسة تقييم الجرع الاشعاعية للعاملين في مختبرات مديرية السلامة نتيجة استخدام مصادر نقطية في معايرة الاجهزة بطريقتين الاولى هي القياس المباشر بواسطة جهاز FAG وقد وجد ان الجرع بهذه الطريقة هي (2.57 µSv/y) لمختبر TLD و(102.3 µSv/y) لمختبر منظومة تحليل اطياف كاما و (µSv/y 20.75) لمخزن الاجهزة .والثانية حساب الجرع باستخدام برنامجRESRAD-BULID وبرنامج RADPRO وقد وجد ان الجرع بهذه الطريقة هي (µSv/y 1.518) لمختيرTLD و (76.65 µSv/y) مختبر منظومة تحليل أطياف كاما و (µSv/y 21.2) لمخزن الاجهزة .هذا يعني ان الجرع التي تم الحصول عليها هي جرع قليلة جدا مقارنة مع الحدود الوطنية والعالمية لمعدل الجرعة (20 mSv/y).


Article
Testing and Commissioning of a Low-Speed Wind Tunnel (LSWT) Test Section
معايرة مقطع اختبار لنفق هوائي واطيء السرعة

Authors: Ihssan Y. Hussain أحسان يحيى حسين --- Anmar Hamid Ali أنمارحامد علي
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2014 Volume: 20 Issue: 11 Pages: 106-125
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The calibration of a low-speed wind tunnel (LSWT) test section had been made in the present work. The tunnel was designed and constructed at the Aerodynamics Lab. in the Mechanical Engineering Department/University of Baghdad. The test section design speed is 70 m/s. Frictional loses and uniformity of the flow inside the test section had been tested and calibrated based on the British standards for flow inside ducts and conduits. Pitot-static tube, boundary layer Pitot tube were the main instruments which were used in the present work to measure the flow characteristics with emphasize on the velocity uniformity and boundary layer growth along the walls of the test section. It is found that the maximum calibrated velocity for empty test section is 55 m/s. Three speeds are tested for uniformity and walls boundary layer at inlet and mid-section of test section. The results show that the flows are uniform at inlet and mid-section with turbulent flow from inlet to outlet.

في هذا العمل تمت معايرة مقطع اختبار لنفق هوائي واطيء السرعة. تم تصميم وتركيب النفق (في عمل سابق) في مختبر الهوائيات بقسم الهندسة الميكانيكية-جامعة بغداد. السرعة التصميمية لمقطع الاختبار هي 70 مثا. تم اختبار ومعايرة الخسائر الاحتكاكية والتجانس للجريان داخل مقطع الاختبار بالاعتماد على المواصفات البريطانية للجريان داخل الانابيب والانفاق. انبوب Pitot-static, وانبوب Pitot للطبقة المتاخمة استخدما كوسائل رئيسة في البحث الحالي لقياس خواص الجريان مع التشديد على تجانس السرعة وتنامي الطبقة المتاخمة لجدران مقطع الاختبار. تم معايرة السرعة القصوى لمقطع الاختبار وهو فرغ وقد كانت 55 مثا. ثلاث سرع تم اختبارها لقياس التجانس والطبقة المتاخمة للجدران عند الدخول والمقطع النصفي لمقطع الاختبار. النتائج اظهرت ان الجريان منتظم عند الدخول والمقطع النصفي بجريان مضطرب من المدخل حتى المخرج.


Article
3D Object Modeling Using Eye on Hand Approach
نموذجية الاجزاء ثلاثية الابعاد ياستخدام طريقة العين في اليد

Authors: Athraa M.Salih Ahmed --- Ali Abbar Khleif
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2016 Volume: 34 Issue: 3 Part (A) Engineering Pages: 497-512
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This research proposed vision measurement system which consists of a camera carried on hand of a robot, which captured 2D image to the object from two sides with a constant distance of the objects. To achieve this work several experimental steps are needed: First step includes calibrating the camera by using a standard block to find the best distance between the camera and the object.The best result of a distance is (410)mm. The second step consists of using MATLAB 7.12.0 (R2011a) program to achieve image processing to get some digital information (number of pixels in each row and column), using the proposed line by line scanning algorithm, to extract 2D object dimensions. The resulted dimensions are found closer to real object dimensions that are measured using a digital vernier and 3d digital probe. Last step includes 2D image manipulating using the proposed algorithms to reconstruct the 3D objects depending on the resulted information (number of pixels).

يقترح هذا البحث نظام القياس المرئي والذي يتضمن كاميرا محمولة على ذراع آلي, لالتقاط صورة ثنائية الابعاد لشكل من منظورين وبمسافة ثابتة من الجسم المراد التقاط الصورة له. ولانجاز هذا العمل نحتاج الى عدة خطوات عملية :الخطوة الاولى تتضمن معايرة الكاميرا بواسطة استخدام قالب قياسي لايجاد المسافة المطلوبة بين الكاميرا والجسم, افضل بعد ناتج هو (410) ملم.الخطوة الثانية تتضمن استخدام برنامج الماتلاب 7.12.0 R2011a)) لانجاز معالجة الصورة للحصول على بعض المعلومات الرقمية (عدد عناصر الصورة في كل صف وعمود), استخدام الخوارزمية المقترحة بمسح كل خط, للحصول على ابعاد الجسم ثنائي الأبعاد . الابعاد التي تم الحصول عليها هي اقرب الى الابعاد الحقيقية التي تم قياسها بواسطة قدمة القياس الرقمية (the digital vernier) ومجس رقمي ثلاثي الابعاد 3D Digital Probe)).الخطوة الاخيرة تتضمن المعاملة على صورة ثنائية الابعاد باستخدام الخوارزميات المقترحة لاعادة تكوين الاجسام الثلاثية الابعاد بالاعتماد على المعلومات الناتجة (عدد عناصر الصورة).


Article
EXTRACTION, IDENTIFICATION AND DETERMINATION OF CAFFEINE AND TRACE METALS IN THREE TYPES OF TEA LEAVES
استخلاص ، تشخيص وتقدير الكافائين وبعض العناصر الفلزية في ثلاثة أنواع من أوراق الشاي

Authors: Sattar S. Ibrahim ستار سالم إبراهيم --- Ismail K. Al-Hitti اسماعيل خليل الهيتي
Journal: Journal of university of Anbar for Pure science مجلة جامعة الانبار للعلوم الصرفة ISSN: ISSN: 19918941 Year: 2009 Volume: 3 Issue: 1 Pages: 45-49
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

Sufficient amounts of caffeine were extracted from Kabbos and Wazzah tea leaves, while traces of caffeine were found in green tea leaves which may be due to unriped tea leaves. Extracted caffeine was identified by UV and IR spectroscopy which offered spectra matching precisely the standard caffeine crystals which confirmed the purity of caffeine and the efficiency of extraction methods. Moderate amounts of sodium, potassium and calcium were found in the three types of tea leaves while lithium was found in traces. The results indicated the presence of necessary elements for the metabolic activities of tea plants and humans who take tea drink with their meals.

الخلاصة: تم استخلاص كميات مناسبة من الكافائين من أوراق شاي الكبوس وشاي ألوزه ، بينما تم الحصول فقط على تراكيز ضئيلة من الكافائين فيأوراق الشاي الأخضر والذي قد يعزى إلى عدم نضج أوراق الشاي. وقد تم تشخيص الكافائين المستخلص بأطياف الاشعه فوق البنفسجية والأشعة تحتالحمراء والتي أعطت معلومات تضاهي المعلومات المنتقاة من الكافائين القياسي والتي أثبتت نقاوة الكافائين المستخلص وجدوى طريقة الاستخلاص. وتمالحصول على كميات معتدلة من فلزات الصوديوم والبوتاسيوم والكالسيوم في أوراق الشاي بأنواعه الثلاثة بينما كان الليثيوم بتراكيز ضئيلة. بينت هذهالنتائج وجود أو توفر بعض العناصر الفلزية الضرورية للفعاليات الحيوية لنبات الشاي وللناس الذين يتناولون شراب الشاي مع وجباتهم الغذائية


Article
A new calibration procedure for expectation of arch length

Loading...
Loading...
Abstract

Background: The aim of the current study was to determine the relationship between arch length and different archwidths, and the possibility of using different arch widths as predictors for expectation of arch length in upper andlower dental arches and in both genders. The current study is a first attempt to select the patients on the basis ofgender in regard to different dental arch widths and length.Subjects and method: The sampling procedure comprised 120 pairs of upper and lower dental casts of untreatedIraqi adult subjects (60 male and 60 females) aged 17 -27 years old. The dental study casts of both upper and lowerdental arches were scanned and digitized by special procedure, six inter-arch widths and the arch length weretraced on images of upper and lower dental arches by the digitization procedure.Results: Student′s t-test showed no marked gender differences for all measurements in both upper and lower dentalarches, regarding the inter-relation between upper and lower dental arches, there were significant correlationcoefficients at 0.01 level for the different arch widths and length, the predictability of the relationship between thearch length and the inter-central incisor width in the upper arch was found to be very strong, while in the lower archthe predictability of the relationship between the arch length and the inter-central incisor width was also found tobe very strong, but it was just found to be strong between the lower arch length and the lower inter-first premolarwidth.Conclusions: The manner of strong correlation between different arch widths and length may be due to that thedental arch variables are acting together as a single biological unit, rather than a collection of discrete entities. Fromthe stepwise multiple linear regression analysis, it can be concluded that the upper inter-central incisor width plays animportant role in the prediction of the upper dental arch length, while in the lower arch, the lower inter-centralincisor and inter-first premolar widths play the same important role in the prediction of the lower dental arch length

ان ھذا البحث ھو اول محاولة بحثیة لمعرفة طول القوس السني وابعاده العرضیة مصنفة على اساس نوع الجنس, وان ھدف ھذا البحث ھو لمعرفة العلاقة بین طول القوسالسني وابعاد عرضیة مختلفھ لھذا القوس وامكانیة التنبؤ بطول القوس السني بأستعمال تلك الابعاد العرضیة المختلفة في كلى الفكین وعند كلى الجنسین, تتألف عینة البحث من مائةوعشرون زوجا من نماذج الاقواس السنیة الفكیة العلویة والسفلیة لاشخاص غیر معالجین تقویمیا تتراوح اعمارھم بین السابعة عشر والسابعة والعشرون عاما, تم فحص صور تلكالنماذج رقمیا بطریقة خاصة وقد تم تتبع واحتسلب ستة ابعاد عرضیة مختافة وطول القوس السني لكلى الفكین بتلك الطریقة الرقمیة, وقد تبین من نتائج البحث بعدم وجود اختلافمعنوي ملحوظ بین الجنسین وفي كل الفكین, وكذلك تبین وجود معامل ارتباط معنوي ملحوظ بین طول القوس السني وتلك الابعاد العرضیة في كلى الفكین وبین ابعاد الفك الواحد,وان ھناك علاقة جدا قویة للتنبؤ بین طول القوس السني والبعد العرضي بین القواطع المركزیة في الفك العلوي والسفلي وعلاقة تنبؤ قویة بین طول القوس السني والبعد العرضي بینالنواجذ الاولیة, نستنتج من ھذا البحث بأن العلاقة الارتباط القویة بین تللك الابعاد یعطینا فكرة بأن الاقواس السنیة تعمل كوحدة واحدة متكاملة و مترابطة في ما بینھا وان تحلیلمتدرجة الانحدار الخطي المتعددة تعطینا فكرة للتنبؤ بطول القوس السني بأستعمال البعد العرضي بین القواطع المركزیة في الفك العلوي والسفلي والبعد العرضي بین النواجذ الاولیةفي الفك السفلي على التوالي.


Article
Object Color Estimation Using Digital Camera for Noncontact Imaging Applications (Case Study: Teeth Color Estimation)
تخمين لون الجسم باستخدام كاميرة رقمية للتطبيقات اللاتلامسية (دراسة الحالة: تخمين لون الاسنان )

Authors: Sinan Majid Abdul satar --- Mehdi Munshid shellal --- Ahmed Chyad Kadhim --- Zainab M. Abdul Ameer
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 4 Part (B) Scientific Pages: 529-538
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

There has been a considerable effort in several fields, for objective color analysis and characterization. This paper study the problem of teeth color estimation using the most common color space in current use being the Commission International ed’ Eclairage L*a*b* parameters of the captured images were derived from Photoshop software and saved as digital shade guides. A set of ceramic teeth shade was used, Images were captured with high resolution digital camera with LED flash and the data obtained was used to calculate the L*a* and b* values, these values conventionally obtained directly from RGB space. This paper proposed a method to estimating teeth color information from acquired camera data by calculating the L*a*b*values from the device independent color space the CIEXYZ space using transformation matrix which is involve calibration and characterization parts. The results showed significant correlation between data obtained from the digital camera using calibration and characterization process with that obtained from spectrophotometer, also the result showed that the digital camera can be used for color measurements in dental clinic, where the digital imaging could be an alternative for using colorimetric or spectrophotometric methods.

هناك جهد كبير في العديد من المجالات، بهدف تحليل وتوصيف اللون. هذا البحث يقدم دراسة لمشكلة تقدير لون الأسنان باستعمال نطاق اللون الأكثر شيوعا في الاستخدام الحالي وهو متغيرات الـL*a*b* للصور التي تم التقاطها يتم اشتقاقها من برنامج فوتوشوب وحفظها كمرشد رقمي.لقد تم استخدام مرشد الأسنان السيراميكي، والتقاط الصور بكاميرا رقمية عالية الدقة مع فلاش LED وقد تم استخدام البيانات التي تم الحصول عليها لحساب قييم الـL*a*b* ، هذه القيم يتم الحصول عليها عادتا مباشرتا من الفضاء RGB. لقد اقترح هذا البحث طريقة لتخمين المعلومات اللونية للاسنان من بيانات الكاميرا بواسطة حساب قييم الـ L*a*b* من الفضاء CIEXYZ باستخدام مصفوفة التحويل التي تتضمن على معايرة وتوصيف.أظهرت النتائج ارتباط كبير بين البيانات التي تم الحصول عليها من الكاميرا الرقمية باستخدام المعايرة وعملية التوصيف مع التي تم الحصول عليها من Spectrophotometer وكذلك اظهرت النتائج امكانية استخدام الكاميرا الرقمية للقياس اللون في عيادة لطب الأسنان، حيث التصوير الرقمي يمكن أن يكون بديلا عن استخدام الأساليب اللونية أو طيفية .


Article
Indoor radon survey in dwellings closed to Basrah Sport City (BSC), Basrah, Iraq
دراسة انبعاث غاز الرادون في المساكن القريبة لمدينة البصره الرياضية / البصره/ العراق

Authors: Waleed H. Al-Mosuwi وليد حميد الموسوي --- Abdul Ridha H. Subber عبد الرضا حسين صبر
Journal: JOURNAL OF THI-QAR SCIENCE مجلة علوم ذي قار ISSN: 19918690 Year: 2014 Volume: 5 Issue: 1 Pages: 71-75
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

Indoor radon measurements in total of 40 samples from dwelling, distributed in the suburb of Bait-Wafi, using two types of SSNTDs radon monitors. The objective of this measurement in to get representative indoor radon data of region closed to Basrah sport city (BSC). A hybrid calibration method between active and passive methods have been used in this work. It was found that the calibration factor for CR-39 is 0.0961 ± 0.0089 T/(〖cm〗^2.d) per 1 Bq m^(-3). The average radon concentrations in dwellings was 192.9 Bq/m3, which is in the range of recommended value for the region.

قياس الانبعاث الداخلي للرادون في مجموع 40 عينة في داخل المساكن في حي بيت وافي القريب من مدينة البصره الرياضية وهدف هذه الدراسة هو ايجاد قاعدة بيانات خاصة لموقع المدينة، واستخدمت طريقة المعايرة المختلطة بين الطريقة المباشرة لقياس الرادون والطريقة المباشرة للقياس لمعايرة كاشف الاثر النووي نوع CR39 وكانت نتيجة المعايرة هي 0.0961 ± 0.0089 T/(〖cm〗^2.d) per 1 Bq m^(-3) ، وقد كان معدل انبعاث الرادون في داخل البيوت هو 192.9 Bq/m3 وهذه القيمة تقع ضمن القيم الموصى بها للمنطقة

Listing 1 - 10 of 20 << page
of 2
>>
Sort by
Narrow your search

Resource type

article (20)


Language

English (20)


Year
From To Submit

2019 (1)

2018 (4)

2017 (1)

2016 (5)

2015 (2)

More...