Experimental and Numerical Investigation to Evaluate the Performance of Helical Coiled Tube Heat Exchanger
تحقيق عملي وعددي لتقييم أداء مبادل حراري حلزوني الأنبوب

Authors: Qasim Saleh Mahdi قاسم صالح مهدي --- Sahar Abdul Fattah سحر عبد الفتاح عبود --- Firas juma Abd فراس جمعة
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2014 Volume: 18 Issue: 4 Pages: 89-110
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Experimental and Numerical investigation of heat transfer enhancement in shell and helical coil tube heat exchanger is carried out in the present work. Experimental work included design of helical coil heat exchanger with different curvature ratio and coil pitch. Three helical coil tube heat exchangers with different curvature ratio (D/d) 12/1, 15/1, 17/1, 20/1 and 24/1 are studied to choose the optimum one. Four helical coils with different coil pitch 1.8d, 2d, 3d, and 5d has been chosen to study the effect of coil pitch on heat transfer coefficient. From experimental results the curvature ratio 17/1 gives optimum helical coil. Experimental results show increases of coil pitch lead to increasing in heat transfer coefficient of the shell side and indicate that convective heat transfer is increased by Reynolds number as well as Dean Number.Numerical geometry has been built using ansys fluent package 14.1 commercial copy with solid work and gambit software program depends on the optimum design . Numerical results show that the temperature decreases along the coil and the temperature difference effect on heat flow along helical coiled. Also there is different in temperature between each turn. Empirical correlation has been developed to predict Nusselt number at helical coil. The comparison between numerical and experimental results show good agreement.

التحقيق التجريبي والعددي لتحسين انتقال الحرارة لمبادل حراري مكون من أسطوانة (القشرة) وأنبوب حلزوني نفذت في هذا العمل .تضمن العمل التجريبي تصميم مبادل حراري حلزوني مع أفضل نسبة تقوس ودرجة حلزنة. خمسه مبادلات حرارية حلزونية مع نسب تقوس مختلفة24/1, 20/1, 17/1, 15/1, 12/1 درست لاختيار أفضل مبادل حراري حلزوني. أربعة مبادلات حرارية مع درجات حلزنة مختلفة (1.8d, 2d, 3d, 5d) صممت لدراسة تأثير درجة الحلزنة على معامل انتقال الحرارة. الملف الحلزوني الذي له نسبة تقوس17/1 اختير كأفضل ملف حلزوني طبقا للنتائج العملية. زيادة درجة الحلزنة تؤدي إلى زيادة معامل انتقال الحرارة في (القشرة). النتائج العملية تشير إلى إن انتقال الحرارة يزداد بزيادة رقم رينولد بالإضافة إلى رقم ديان.أما الجانب العددي فقد تم استخدام برنامج ansys fluent في رسم الشكل باستخدام برنامج solid workو gambit في التحليل وبالاعتماد على أفضل تصميم. وأظهرت الدراسة العددية ان درجات الحرارة تقل على طول الملف وفرق درجات الحرارة له تأثير على انتقال الحرارة وهناك فرق في درجة الحرارة بين لفة واخرى .تم تطوير معادلة تجريبية لتوقع عدد ناسلت لأنبوب محلزن كما بينت المقارنة بين النتائج العملية والعددية بينت توافق جيد.


Article
Numerical Analysis Of Refrigerant Flow In Different Types Of Capillary Tubes Used R1270
تحليل عددي لجريان المائع في انواع مختلفة من الانابيب الشعرية باستخدام غاز R1270

Author: Haider ali hussen حيدر علي حسين
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2013 Volume: 17 Issue: 6 Pages: 10-21
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The capillary tube is a common expansion device used in small sized refrigeration and air-conditioning systems. The main focus lies on the analysis of the refrigerant flow behavior in the along the capillary tube with different shapes (straight-coiled-serpentine) as well as using alternative (R1270) with different geometrical parameters by using a commercial code FORTRAN power station for the simulation. Capillary geometrical parameters will include diameter, coiled diameter, and curve diameter. Results showed that when capillary tube internal diameter increase from 1.4 mm to 1.8 mm. Straight tube length increases from (1.2978m) to (4.8738m) with ratio (73.37%) , Coiled tube length increases from (0.589m) to (1.958m) with ratio (69.91%) at coiled diameter (dd=10mm) ,and The serpentine tube length increases from (0.859m) to (2.671m) with ratio (67.84%) at curve radius ( )or curve diameter (dr=10mm).. The ideal capillary tube type is coiled. Because length decrease with comparison straight and serpentine.

إنّ الإنبوبَ الشعريَ هو أداة توسّعِ مشتركةِ إستعملتْ في التبريدِ بحجمِ الصغيرِ وتكييف الأنظمةِ. يهدف البحث على تحليلِ سلوكِ تدفقِ المبرّدَ على طول الإنبوبِ الشعريِ بالأشكالِ المختلفةِ (أفعوانية مستقيمة ملفوفة) بالإضافة إلى إستعمال البديلِ (R1270)مع مختلف المتغيرات الهندسية بإستعمال لغةِ فورتران للمحاكاةِ..المتغيرات الهندسية للانبوب الشعري ستتضمن قطر, قطر اللفة ,قطر التقوس .أظهرت النتائج بأنّ عندما يزيد القطر الداخلي للانبوب الشعري من (1.4 مليمتر -1.8 مليمتر) طولَ الإنبوبِ المستقيمِ يَزِيدُ مِنْ (1.2978 m) إلى (4.8738 m) بالنسبةِ (73.37 %) ويزيد طولِ الإنبوبِ الملفوفةِ مِنْ (0.589 m) إلى (1.958 m) بالنسبةِ (69.91 %) عند القطرِ الملفوفِ (dd =10 مليمتر) ويَزِيدُ طولَ الإنبوبِ الأفعوانيِ مِنْ (0.859 m) إلى (2.671 m) بالنسبةِ (67.84 %) عند نصفِ قطر التقوس ( ) أَو قطر التقوس (dr=10mm). إنّ نوعَ الإنبوبِ الشعريِ المثاليِ هو ملفوفُ. لان الطولِ اقل بالمقارنة مع الانبوب المستقيم والأفعواني.


Article
Experimental and Numerical Investigation to Enhance the Performance of Helical Coiled Tube Heat Exchanger by Using Turbulators
دراسة عملية وعددية لتحسين أداء مبادل الحراري ذو أنبوب ملتف حلزوني باستخدام العوائق

Loading...
Loading...
Abstract

In the present work, numerical and experimental investigation is carried out to evaluate the performance of helical coiled tube heat exchanger with wire coil insert. Experimental work included design of wire coiled and inserted into a vertically positioned plain copper helical tube heat exchanger. The effects of wire coil insert with different parameters on heat transfer and friction loss in the helical tube were examined with Dean number ranging from 700 to 2000.The experiments of coiled wire were performed, firstly with three different pitches (P= 15, 20 and 30)mm with constant circular cross section(a=1mm), secondly with different cross section (circular and square) at constant pitch 15mm, and thirdly with two different square wire thickness (a =1, 2) mm at constant pitch 15mm. The numerical analysis was carried out to simulate the flow and heat transfer in a helical coil tube with wire coil insert at pitch (15mm) with different flow rates by using ANSYS FLUENT package 14.0. The experimental results showed that the use of tubular leads to a considerable increase in heat transfer and friction loss over those of a smooth coiled tube. The Nusselt number increases with the increasing of Dean number and the reduction in pitch for wire coils. The coiled square wire provides higher heat transfer than the circular one under the same conditions. A new empirical correlations have been developed to predict Nusselt number of the helical coil heat exchanger. Also the comparisons between numerical and experimental results show good agreement.

في البحث الحالي دراسة عددية وعملية لتقييم اداء مبادل حراري ذو انبوب حلزوني بداخله سلك حلزوني شبيهه بالنابض كأداة محسنة لانتقال الحرارة ومقارنة أداؤها في الأنابيب مع الأنابيب الملساء. شمل العمل التجريبي تصميم سلك ملفوف وضع داخل أنبوب حلزوني موضوع بشكل عمودي تم دراسة تأثير أبعاد مولد الدوامات على انتقال الحرارة ومعامل الاحتكاك ضمن رقم دين (700 -2000) .تم اجراء الاختبارات عند متغيرات عديدة للسلك الحلزوني(مولد الدوامات),اولا عند استخدام سلك ذو مقطع دائري بثلاثة ابعاد مختلفة من الخطوة (15و20و30 p=)ملم, ثانيا عند استخدام سلك بمقطعين (دائري ومربع)لخطوة ثابتة(p=15mm)وثالثا عند استخدام سلك ذو مفطع مربع بطول ضلع a=1,2mm))لخطوة ثابتة قدرها((p=15mm.تضمن الجانب العددي نمذجة لسلوك الجريان وانتقال الحرارة للمبادل الحراري باستخدام برنامج حاسوبيANSYS FLUENT 14))لتحديد تأثير السلك الحلزوني بخطوة ثابتة ((P=15mm أظهرت النتائج التجريبية أن استخدام مولدات الدوامة يؤدي إلى زيادة كبيرة في نقل الحرارة وفقدان الاحتكاك اكثر من تلك أنبوب الحلزوني الاملس . يزداد عدد نسلت مع زيادة عدد دين ونقصان الخطوة للسلك الحلزوني. لقد بينت المقارنة بين النتائج العملية والنظرية حصول تطابق جيد بينهما. طورت معادلة تجريبية لتوقع عدد ناسلت لأنبوب حلزوني مع إضافة السلك الحلزوني بالداخل.


Article
Solar Water Heater With Shell And Helical Coiled Tube Heat Exchanger As A storage Tank

Authors: SAHAR MAJEED --- Faiz F. Mustafa --- Karima E. Amori
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2011 Volume: 17 Issue: 5 Pages: 1213-1222
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this work an experimental study is performed to evaluate the thermal performance of locally made closed loop solar hot water system using a shell and helical coiled tube heat exchanger as a storage tank. Several measurements are taken include inlet and outlet temperatures of both collectors and supply water and temperature distribution within the storage tank. This is beside the water flow rate in both collectors and load cycle. The main parameters of the system are obtained

يتضمن العمل الحالي دراسة عملية لتقييم الأداء الحراري لسخان شمسي مصنع محليا ذو خزان مكون من قشرة وأنبوب ملتف حلزونيا كمبادل حراري . أجريت عدة قياسات لدرجة حرارة دخول وخروج الماء لكلٍ من المجمع الشمسي والخزان و ماء الأستهلاك , و توزيع درجات الحرارة داخل الخزان . هذا بالأضافة الى قياس معدل تدوير الماء في المجمع وماء الأستهلاك . تم التوصل الى تحديد المؤثرات الرئيسية المتحكمة بالمنظومة.


Article
THERMAL IMPROVEMENT OF SOLAR HOT WATER

Journal: Iraqi journal of mechanical and material engineering المجلة العراقية للهندسة الميكانيكية وهندسة المواد ISSN: 20761819 Year: 2009 Volume: B Issue: first conf./ eng. coll. Pages: 244-257
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

This study includes a comparison between the performances of two locallyfabricated similar flat plate solar collectors. One of these collectors is a new design ofaccelerated absorber, its risers are of converging ducts (the exit area is half that at theentrance). The other collector is of conventional absorber (its risers have the same crosssectional area along its length). Each collector is the major part of an indirectthermosyphon circulation solar hot water system facing the south with a fixed tilt angleof 33.3 o from the horizontal. A side by side experiments are conducted for three months 1,2,&3 of 2009 for different water withdrawal profiles, continuous, interrupted and no load, also forhorizontal and vertical storage tank orientations. Two types of storage tanks areinvestigated (two concentric cylinders and helically coiled tube in cylinder). Results show that a considerable enhancement of thermal performanceapproximately (60%) of absorbed heat (useful gain) at solar noon is obtained for thenew design in comparison with the conventional type. The instantaneous efficiency was31.5% for the accelerated absorbed flat plate at solar noon, while that of conventionalabsorber was (16.5%). The longitudinal water temperature variations in the risers ofaccelerated absorber were larger than that belong to the conventional absorber. Thestratification in the storage tank is considerably improved for the solar hot water systemwith the new absorber design in which the maximum temperature indicated was 50 C(vertical storage tank) while that for conventional absorber was 37 oC. The stratificationobtained for coiled tube in cylinder storage tank indicates a good thermal performancewith less space requirements. Also the circulation rate in the accelerated absorber washigher when it is connected to coiled tube than that when it is connected to theconcentric cylinders.o


Article
Experimental Study of Heat Transfer Coefficients of Shell and Helically Coiled Tube Heat Exchangers
دراسة عملية لمعامل انتقال الحرارة لمبادل حراري مكون من ملف حلزوني واسطوانة

Authors: Sattar Jaber Habeeb Al-Jabair --- Ammar.A.Hussain.A.AL-taee
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 1 Part (A) Engineering Pages: 172-196
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This work presents an experimental study of the heat transfer coefficients of shell and helically coiled tube heat exchangers. Three heat exchangers with different coil pitches were tested for both parallel-flow and counter-flow arrangement. Water is used as working fluids in shell side and tube side. The study is conducted at the hot water mass flow rates ranging between (0.02 - 0.12) kg/s while cold water is kept constant at (0.055 kg/s). The range of inlet temperatures of cold and hot water are (19 - 28 °C), and (50 - 80 °C), respectively. All experiments were performed at the Dean Number for coiled side range of (3803 - 12117). The work is performed to evaluate the influence of the tube diameter, coil pitch, shell-side and tube-side mass flow rate, and inlet temperatures of tube-side over the axial temperature distribution of heat exchanger, effectiveness, modified effectiveness and heat transfer coefficient. The evaluating has been performed for the steady-state . The results indicate that the major effect on the axial temperature distribution of heat exchanger was the mass flow rate ratio (mr). Also the modified effectiveness decreased with increasing mass flow rate ratio. The main influence on the shell-side heat transfer coefficient was coil pitch. Develop an equation to correlate Nusselt Number as function of Reynolds Number, Prandtl Number, Dean Number and helical coil Number.

يقدم هذا العمل دراسة عملية لمعاملات انتقال الحرارة بالحمل القسري لمبادل حراري مكون من اسطوانة (الصدفة) وانبوب ملفوف بشكل حلزوني. تم اختيار ثلاث ملفات وبدرجات حلزون مختلفة (coil pitches) لمقطع الأختبار وللجريان المتوازي والمتعاكس. تم استعمال الماء البارد والحار كسوائل تشغيل من جانب الأسطوانة والملف الحلزوني على التوالي. جرت الدراسة بنسب تدفق للماء الحار تتراوح بين (0.02 - 0.12 kg/s) بينما الماء البارد يبقى ثابت عند .(0.055 kg/s) ان مدى درجات الحرارة لدخول الماء البارد والحارتتراوح بين (19 - 28 °C) و(50 - 80 °C) على التوالي. كل التجارب اديت للأعداد دين تترواح بين .(3803 - 12117) ان الغرض من هذا العمل هو تقييم تأثير كل من قطر الانبوب ، درجة الحلزون (coil pitches) ومعدل التدفق من جانب الملف ومن جانب الصدفة ودرجة حرارة الدخول من جانب الملف على كل من شكل توزيع درجات الحرارة المحورية داخل المبادل، الفعالية،الفعالية المُعَدلّة ومعامل انتقال الحرارة لكل من الجريان المتوازي والمتعاكس. اخذت جميع القراءات للحالة المستقرة فقط. تشير النتائج أن التأثير الرئيسي على شكل توزيع درجات الحرارة المحورية داخل المبادل الحراري كانت نسبة التدفق (mr). تشير النتائج ايضاً ان الفعالية المعدلة تقل مع زيادة نسبة التدفق (mr) . التأثير الرئيسي على معامل انتقال الحرارة الخارجي ( ho ) كان درجة الحلزون (coil pitches) . تطوير معادلات لربط عدد نسلت بعدد رينولد وعدد برانتل وعدد دين.


Article
EXPERIMENTAL AND NUMERICAL STUDY OF THE HEAT TRANSFER COEFFICIENTS OF DOUBLE PIPE HELICALLY COILED HEAT EXCHANGER
دراسة عملية وعددية لمعامل انتقال الحرارة لمبادل حراري مكون من ملف حلزوني مزدوج الانبوب

Authors: Ammar A. Hussain --- Ali S. Golam
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2016 Volume: 20 Issue: 6 Pages: 81-102
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

This work introduces an experimental and numerical study of the heat transfer coefficients of double pipe helically coiled heat exchanger. It tested for both parallel and counter flow arrangements. Water is used as working fluid in inner tubes side and annulus tube side. The mass flow rate has range between (0.032 - 0.0721) kg/s for cold water while hot water is kept constants at (0.0724 kg/s). Also the range of inlet temperatures of cold and hot water are (20 - 25°C), and (40 - 70 °C), respectively. All experiments performed at the Dean Number for annulus tubes side range of (1250 - 1700). The study directed to focus on influencing the inlet mass flow rate of annulus tubes-side, and inlet temperatures of inner tubes-side over the effectiveness, axial temperature distribution of heat exchanger, efficiency and heat transfer coefficient. All experimental data performed at the steady-state conditions. The results show that the mass flow rate ratio ((m_r ) ̇) effects the axial temperature distribution of heat exchanger also, the effectiveness and efficiency decreased by increasing mass flow rate ratio. Likewise, comparisons between numerical and experimental results have been made. Empirical correlations between the Nusselt Number with Dean and Prandtl Numbers for the annulus tube have been found.

يقدم هذا العمل دراسة عملية وعددية لمعامل انتقال الحرارة لمبادل مزدوج الانبوب ملفوف بشكل حلزوني. جرى الاختبار للجريان المتوازي والمتعاكس. تم استعمال الماء كسائل تشغيل من جانب الانبوب الداخلي والحلقي. نسب التدفق تتراوح بين 0.072 kg/s) - 0.032) للماء البارد بينما للماء الحار يبقى ثابت عند (0.0724 kg/s) . مدى درجات الحرارة لدخول الماء البارد والحار تتراوح بين ( (20 - 25 °Cو ( (40 - 70 °Cوعلى التوالي. كل الاختبارات اجريت لاعداد دين (De ) من جانب الانبوب الحلقي تتراوح بين (1250 - 1700). تركز الدراسة على تأثير كل من معدل التدفق للانبوب الحلقي ودرجة الحرارة للانبوب الداخلي على شكل توزيع درجات الحرارة المحوري داخل المبادل, وفعالية وكفاءة المبادل, ومعامل انتقال الحرارة. تظهر النتائج ان لنسبة التدفق ((m_r ) ̇) تأثير واضح على شكل توزيع درجات الحرارة المحورية للمبادل. وتؤثر زيادتها سلبا على فعالية وكفاءة المبادل. تم مقارنة النتائج العددية والعملية . تم ايجاد معادلة تجربيية لربط عدد نسلت من جانب الانبوب الخارجي بكل من عدد برانتل وعدد دین .


Article
EXPERIMENTAL INVESTIGATION OF NATURAL CONVECTION HEAT TRANSFER INA HELICALED COILED PIPE
دراسة عملية لانتقال الحرارة الطبيعي في الانبوب الملتف حلزونيا

Loading...
Loading...
Abstract

The research presents an experimental investigation on the steady state natural convection heat transfer for helical coiled pipes with a vertical orientation. Water is used as the working fluid for both the target fluid and the bath medium. The heat transfer characteristics have been studied for three helical coils that having three curvature ratio (0.056, 0.0625, and 0.115) and three coil pitches (12.5, 25, and 37.5)mm with a volume flow rate of the target fluid ranges (10-25)L/min and two constant bath water temperatures (70 and 90)oC. All the experiments were performed for Rayleigh number range (1.76*109 – 1.15*1012). The experimental data have been used in SPSS software to predicted the empirical correlation of outside Nusselt number as a function of Rayleigh number by using height of the coil as a characteristic length then using this empirical relation in a computer program that have written in Fortran 90 to predict the outlet temperature and compared with the measured one. The results show that the inner and outer heat transfer coefficients increase with increasing of curvature ratio (d/D) and the mass flow rate. Also the results show that the difference between the measured and predicted outlet temperature equal to 1.5oC.

تضمن البحث دراسة تجريبية لانتقال الحرارة بالحمل الحر المستقر ولانبوب ملتف حلزونيا وموضوع بشكل عمودي. المائع المستخدم هو الماء ولكل من الانبوب الحلزوني والحوض المائي تم دراسة خواص انتقال الحرارة لثلاث انواع من الانابيب الحلزونية وبثلاث نسب انحناء 0.115,0.0625,0.056)) ولثلاث خطوات (12.5, 25, 37.5) ملم مع معدل تدفق حجمي يتراوح (10-25 ) لتر/دقيقة, ودرجات حرارة ثابته للحوض بمقدار ( 90oC, oC 70) . تم اجراء الدراسة عند مدى رقم رايلي يتراوح ( 1.76×109- 1.15×1012) تم استخدام النتائج التجريبية في برنامج احصائي من اجل ايجاد علاقة تربط بين رقم نسلت الخارجي و رقم رايلي باعتماد ارتفاع الملف كطول مميز في رقم رايلي ومن ثم استخدام تلك العلاقة في برنامج حاسوبي مكتوب بلغة فورتران 90 من اجل تنبؤ درجة حرارة الملف الخارجة . بينت النتائج ان معامل انتقال الحرارة الداخلي والخارجي يزداد مع زيادة نسبة الانحناء (d/D) وزيادة معدل التدفق واوضحت ايضا ان الفرق بين درجة حرارة الملف الخارجة المتنبئة والمقاسة هي ( 1.5 oC).


Article
Experimental and Numerical Study of Heat Transfer Enhancement in a Shell and Tube Heat Exchanger using Helical Coiled Wire Inserts

Authors: Musa Mustafa Weis --- Ehsan Fadhil Abbas --- Ahmed Sami Ridha
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2018 Volume: 25 Issue: 2 Pages: 74-79
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

An experimental work on heat transfer enhancement in a shell and tube heat exchanger by insertion of helical coiled wires into the tube bundle was conducted. Four different pitch sizes were used (4.8, 6.4, 8.0, 9.6) mm. The working fluid for both shell and tube sides of the exchanger was water. Flow arrangement used was parallel and laminar for both sides with a Reynolds number for the tube inside ranging (100-920). Variables were taken into account, including; convection heat transfer coefficient, number of heat transfer units, thermal effectiveness, and pressure drop. CFD analysis was done in order to validate the experimental results. The study results showed an increase in heat transfer coefficient on the tube side by 54% due to the use of 9.6 mm pitched inserts. Highest thermal effectiveness obtained was in the case of 9.6 mm pitch inserts. Pressure drop rose up to 260% due to inserts.


Article
Thermal Characterization of Turbulent Flow in a Tube With Discrete Coiled Wire Insert
التوصيف الحراري لجريان مضطرب بأنبوب مزود بسلك ملفوف متقطع كأداة حشر

Author: Ibtisam Ahmed Hasan Salih ابتسام احمد حسن صالح
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2014 Volume: 18 Issue: 6 Pages: 126-143
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The present study aims to investigate the effect of adding discrete coiled wire to enhance the heat transfer in heat exchanger. The coiled wire used in experiments were made from steel circular cross section wire with (b = 4 mm) diameter. The outer coil wire's diameter was (B=36.5 mm) and length after been winding is (l = 100 mm), the discrete distribution of coil wires, by different spacing (S) between them with (S/l = 0.22 ,0.57 &1.2) ,which require to distribute 10, 8 & 6 coiled wires along test section respectively, were considered in the experimental study . The experiments have been carried at constant heat flux rate and different flow rates of air that started from (Re=6000) and increased gradually to reach the following Re. (7500, 9000, 10500, 12000 and 13500). The results show that the use of the S/l=0.57 results in the augmentation of pressure loss around 33.2% higher than that of the S/l=0. In addition, it can be found that for using coiled wire turbulator with spacing ratios(0, 0.22, 0.57,& 1.2 ), the improvement of average heat transfer rate is, respectively, about 112%, 119.3%, 141.3%&132% higher than those the plain tube while the friction factor is 300%,392% ,432%, and 322% times of the plain tube.

يهدف البحث لدراسة تأثير إضافة ملفات متقطعه لتحسين انتقال الحرارة في المبادل الحراري. الملف المستخدم في التجارب مصنوع من مادة الستيل دائري المقطع قطره (b=4 mm) . القطر الخارجي للملف كان (B=36.5 mm) وطوله بعد اللف هو (l=100 mm), توزيع التقطيع للملف بفراغات (S) بـ ((S/l = 0.22 ,0.57 &1.2, والتي تتطلب توزيع 10, 8 و6 ملفات على طول جزء الاختبار تباعاً, كما هو مفروض في الدراسة العملية. التجارب أُجريت عند معدل ثابت للفيض الحراري وبمعدلات مختلفة لجريان الهواء ابتداء من (6000Re=) وتتزايد بشكل تصاعدي لتصلRe كالتالي (7500, 9000, 10500, 12000 و 13500). النتائج أظهرت أن استخدام s/l= 0.57 النتائج تزيد من خسائر الضغط بنسبة 33.2% أعلى من S/l= 0. بالإضافة , يمكن أن يوجد أن استخدام ملف الحشر بنسب فراغية (0, 0.22, 0.57 و1.2) معدل تحسين انتقال الحرارة يكون بالتتابع 112%, 119.3%, 141.3 و132% أو هو أعلى من قيمته في الأنبوب الأملس بينما معامل الاحتكاك يزداد بمقدار 300%, 392%, 432% و 322% مما هو علية في الأنبوب الأملس.