research centers


Search results: Found 3

Listing 1 - 3 of 3
Sort by

Article
New Approach for the On-Line Spectrophotometric Determination of Folic Acid in Pure and Pharmaceutical Preparation via Oxidation by Cerium(IV) Sulphate Using Ayah 3Sx3-3D-Solar Cell CFI Spectrophotometer Analyzer
نمط جديد للتقدير الاني الطيفي لحامض الفوليك في المستحضرات الصيدلانية والنقية من خلال الاكسدة بكبريتات السيريوم (IV) بأستخدام المحلل الطيفي للحقن الجوياني المستمر Ayah 3Sx3-3D-solar cell

Author: Aktham N. Jasim اكثم نصيف جاسم
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2014 Volume: 55 Issue: 3B Pages: 1153-1163
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A newly photometric analytical method characterized by its speed and sensitivity was developed for the determination of folic acid in pure and pharmaceutical samples via its oxidation to reddish-orange coloured complex through oxidation by cerium (IV) sulphate in aqua medium using homemade Ayah 3Sx3-3D-solar cell CFI photometer. The colored species were determined using supper bright green light emitting diode (LED) as a source. A 100µl was taken as a best sample volume for the determination of folic acid. The linearity of calibration curve for the instrument response versus folic acid concentration was 0.005-20 mmol.L-1 while the L.O.D. was 0.5  mol.L-1 from the stepwise dilution for the minimum concentration of lowest concentration in the linear dynamic range of the calibration graph. The correlation coefficient (r) was 0.9994 while the percentage linearity (r2%) was 99.88%. The method was applied successfully for the determination of folic acid in pharmaceutical preparation. RSD% for 8 mmo.L-1 (n=6) less than 1% . Using paired t-test it was shown that there was no significant difference between the proposed method and official method (Quoted value- 5mg) and on that basis the new method can be accepted as an alternative analytical method.

طورت طريقة تحليلية طيفية سريعة وحساسة لتقدير حامض الفوليك في المستحضرات الصيدلانية والنقية من خلال الاكسدة إلى معقد ملون برتقالي -محمر بوساطة اكسدته بكبريتات السيريوم (IV) في الوسط المائي بأستخدام منظومة الحقن الجرياني المستمر والمصممة محليا Ayah 3Sx3-3D-solar cell .قدرت القطع الملونة باستخدام ثنائي وصلة باعث للضوء الاخضر الساطع كمصدر تم اخذ 100 مايكروليتر كأفضل حجم لانموذج محقن لتقدير حامض الفوليك. الخطية لمنحني المعايرة للاستجابة الالية ضد تركيز حامض الفوليك 0.005-20 مللي مول.لتر-1 بينما حد الكشف 0.5 مايكرومول.لتر-1 من التخفيف التدريجي لاقل تركيز في منحني المعايرة . معامل الارتباط (r) 0.9994 بينما نسبة الخطية (r2%) 99.88% . طبقت الطريقة بنجاح لتقدير حامض الفوليك في المستحضرات الصيدلانية . الانحراف القياسي النسبي المئوي لتركيز 8 مللي مول. لتر-1 (n=6) اقل من 1% . بأستخدام اختبار t- المزدوج تبين انه لايوجد فرق جوهري بين الطريقة المقترحة والطريقة الرسمية (القيمة الموثقة -5 ملغم) وعلى هذا الاساس بالامكان قبول استخدام الطريقة المستحدثة كطريقة تحليلية بديلة.


Article
Flame Atomic Emission and Colorimetric Methods for the Determination of Cephalexin Monohydrate in Pharmaceutical Preparations
التقدير بطريقتي الانبعاث الذري اللهبي واللوني للسيفالكسين احادي الماء في مستحضراته الصيدلانية

Authors: Abbas S. Hasan Al-kahdimy عباس شبيب حسن الكاظمي --- Mohammed Abdullah Ahmed محمد عبد الله احمد
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2016 Volume: 13 Issue: 2ملحق ابحاث المؤتمر الوطني الثاني للكيمياء Pages: 480-488
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

We propose two simple, rapid, and convenient spectrophotometric methods which are described for the determination of cephalexin in bulk and its pharmaceutical preparations. They are based on the measurement of the flame atomic emission of potassium ion (in the first method) and colorimetric determination of the green colored solution at 610 nm formed after the reaction of cephalexin with potassium permanganate as an oxidant agent (in the second method) in basic medium. The working conditions of the methods are investigated and optimized. Beer's law plot shows a good correlation in the concentration range of 5-40μg ml-1. The detection limits are 2.573,2.814 μg ml-1 for the flame emission photometric method and 1.844,2.016 μg ml-1 for colorimetric methods for capsules and suspensions respectively.The methods are successfully applied to the determination of cephalexin in capsules and suspensions, and the obtained results are in good agreement with the label claim. No interference is observed from the commonly encountered additives and excipients.

تم اقترحنا طريقتان طيفيتان امتازت كل منهما بالبساطة والسرعة والملائمة لتقدير عقار السيفالكسين كمادة نقية او في مستحضراته الصيدلانية ,استندت الطريقتان على اكسدة العقار بمحلول برمنغنات البوتاسيوم في الوسط القاعدي ,ومن ثم قياس شدة الانبعاث الذري اللهبي لايون البوتاسيوم في الطريقة الاولى ,و قياس الامتصاصية في المنطقة المرئية للون الاخضر المتكون عند الطول الموجي 610 نانومتر في الطريقة الثانية. وبعد تحديد ظروف العمل المثلى, من خلال العلاقة البيانية بين شدة الانبعاث او الامتصاصية والتركيز ,وجد ان مدى الخطية لمطاوعة قانون بير-لامبرت في حدود التراكيز 5-40 مايكروغرام مل-1. ان حدود الكشف كانت 2.573 و 2.814 مايكروغرام مل-1 لطريقة الانبعاث الطيفي اللهبي الاولى و 1,844 و 2.016 مايكروغرام مل-1 لطريقة الامتصاص في المنطقة المرئية.طبقت الطريقتان بنجاح لتقدير عقار السيفالكسين في نماذجهة النقية او مستحضراته الصيدلانية, من خلال النتائج المستحصلة والخاصة بقيم الاسترجاعية المئوية اظهرت الطريقتان ان لاتأثير للمتداخلات على عملية القياس.


Article
Colorimetry and Indirect X-ray Fluorescence Determination of Active Ingredients in Tetracycline Hydrochloride Drug and Injection Solution of B12 Vitamin Using of Polyurethane Foam Sorbents

Loading...
Loading...
Abstract

The simple and available technique of colorimetry and indirect X-ray fluorescence determination of tetracycline hydrochloride (in the form of the colored complex with iron(III) ions) and cyanocobalamine (in the form of the colored thiocyanate complex with cobalt(II) ions) is offered. The analytes were separated from the accompanying components by sorption to polyurethane foam based on ethers. The conditions of sorption separation and measurement of the analytical signal of these substances are optimized. The obtained results of tetracycline drug and injection solution of the B12 vitamin are in satisfactory agreement with data declared by the manufacturer.

The simple and available technique of colorimetry and indirect X-ray fluorescence determination of tetracycline hydrochloride (in the form of the colored complex with iron(III) ions) and cyanocobalamine (in the form of the colored thiocyanate complex with cobalt(II) ions) is offered. The analytes were separated from the accompanying components by sorption to polyurethane foam based on ethers. The conditions of sorption separation and measurement of the analytical signal of these substances are optimized. The obtained results of tetracycline drug and injection solution of the B12 vitamin are in satisfactory agreement with data declared by the manufacturer.

Listing 1 - 3 of 3
Sort by
Narrow your search

Resource type

article (3)


Language

English (3)


Year
From To Submit

2017 (1)

2016 (1)

2014 (1)