research centers


Search results: Found 98

Listing 1 - 10 of 98 << page
of 10
>>
Sort by

Article
Structural Behavior of Novel ECC Short Columns Subjected to Eccentric Loading

Authors: Safaa mashshay --- Adnan Al-Sibahya
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2020 Volume: 13 Issue: 1 Pages: 31-36
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

This study was undertaken in order to investigate the structural behaviour of novel Engineering Cementitious Composites (ECC) columns subjected to eccentric loading. These columns were experimentally formulated using a hybridization of steel and polypropylene fibres. Two ratios were adopted for the steel fibres of 0.5% and 1%, whilst the polypropylene fibre was kept to be constant at a ratio of 0.5% for all of the ECC columns. The eccentric loads were applied at two eccentricities: small (h/6) and large (5h/12). A comparison was also made with the behaviour of self-compacting concrete and traditional ECC columns containing either steel or polypropylene fibres. The vertical and lateral deformations as well as the maximum load at failure were noted. The results obtained showed that the hybrid ECC columns exhibited higher load carrying capacities when compared with those of both self-compacting concrete and traditional ECC columns. The percentage increase was 30%. The hybrid ECC column samples containing 1% steel fibre did not show a signification difference in the load-deformation behaviour when it compared with that containing 0.5% steel fibre. The values of eccentricity governed the global behaviour of the tested columns. The predicated load carrying capacity of the ECC columns needs a magnification factor in case of concentric test, and to take into account the existence of fibres ratio when calculating the area of steel reinforcement for eccentric loading.


Article
A Study into the Dynamic Behaviour of Packed Distillation Columns

Authors: Karima M. Putrus --- Ali M. Hameed --- Ittehad F. Tobia
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2007 Volume: 8 Issue: 3 Pages: 23-29
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The study of the dynamic behaviour of packed distillation column was studied by frequency response analysis using Matlab program. A packed distillation column (80 mm diameter) (2000 mm height) filled with glass packing (Raschig Rings 10mm), packing height (1500 mm) has been mod for separation of methanol-water mixture (60 vol%). The column dynamic behaviour was studied experimentally under different step changes in, feed rate (*30%), reflux rate (+22%), and reboiler heat duty (+150%), the top and bottom concentration of methanol were measured. A frequency response analysis for the above step response was carried out using Bode diagram, the log modulus and the phase angle were used to analyze the process model. A Matlab program was used to study the dynamic model for continuous packed distillation to predict the transient response to a step change in feed rate, reflux rate and reboiler heat duty. It also used to find the frequency response analysis using experimental data and the results were compared with ARX7Auto Recursive) model, then the plot of Bode diagram was carried Finally the transfer function to step change in feed rate was found and represented by second order.For reflux rate change, it was found that for the top concentration, it can be represented by first order (lead — lag system).Finally a comparison between the experimental and theoretical response curves were made, it was found that the model obtained from Matlab program (Bode diagram) gave a good agreement with experimental data while the model obtained using process reaction curve method shows a deviation between the theoretical and experimental data.


Article
Behavior of Short Reinforced Porcelinite Concrete Columns Under Concentric Loads
تصرف الأعمدة الخرسانیة المسلحة القصیرة المصنوعة من ركام البورسلینایت تحت الاحمال المركزية

Authors: Kaiss F. Sarsam --- Ihsan A. S. Al-Shaarbaf --- Mustafa S. Shuber
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2009 Volume: 27 Issue: 6 Pages: 1219-1233
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This study presents on experimental method to investigate the behavior ofreinforced porcelinite concrete columns subjected to concentric load. The experimentalwork includes investigation of ten lightweight concrete columns with square crosssection 190×190mm and 1000mm in length subjected to concentric load to assess theeffect of the amount of longitudinal steel reinforcement, lateral tie reinforcement andgrade of concrete. From the experimental observation it was found that the porceliniteaggregate is a good structural material to produce lightweight concrete columns. It isnoted from tested columns that keeping the amount of the longitudinal steel ratioconstant, the increase in the amount of transverse steel to about four times (bydecreasing the spacing to about a quarter according to the ACI-Code (318M-05)) gave asignificant influence on column post-cracking behavior. The improvements in thecolumn due to higher value of confinement include: (i) less brittle behavior; (ii)significantly less damage to the concrete core; (iii) 12% increase in column loadcarrying capacity. Also, A modified formula for column capacity is proposed to takeinto account the influence of spacing of ties (effect of confinement).

تقدم هذه الدراسة بحثا عمليا لدراسة سلوك الاعمدة الخرسانية خفيفة الوزن التي تحوي علىركام البورسلنايت تحت تاثير الاحمال المحورية . يتضمن الجزء المختبري فحص عشر ة أعمدة خفيفة190 ملم) وبطول ( 1000 ملم) والمعرضة الى احمال محورية × الوزن مربعة المقطع بابعاد ( 190ومقاومة الخرسانة للانضغاط . (lateral) لتقدير تاثير كمية الحديد الطولي وكمية الحديد العرضييمكن الملاحظة من خلال التجارب المختبرية (العملية) بان مادة ركام البورسل نايت جيدة انشائيا وملائمةلتنتج خرسانة خفيفة الوزن وكذلك يمكن الملاحظة عند الحفاظ على كمية الحديد الطولي ثابتة فانالزيادة في الحديد العرضي اربعة أضعاف حسب ماتحدده متطلبات الكود الامريكي لسنة 2005 يؤثرتاثيرا كبيرا على تصرف العمود في مرحلة ما بعد التشقق . ان تحسين اداء وكفاءة العمود من خلالاستخدام نسبة حديد عرضي اكبر يؤدي الى : أ-زيادة في المطيلية . ب-اقل تضررا لقلب العمودالخرساني (الجزء الخرساني من العمود والمحصور داخل الحديد العرضي). ج-زيادة 12 % للتحملالاقصى للعمود.كذلك تم تطوير معادلة تجريبية لحساب الحمل تاخذ بنظر الاعتبار تاثير الحديد العرضي.

Keywords

Porcelinite --- R.C. --- Columns


Article
Rehabilitation of Four Stories Concrete Building
أعادة تأهيل بناية هيكلية خرسانية مكونة من أربعة طوابق

Author: Nihad T. Khshain نهاد طارق خشين
Journal: Univesity of Thi-Qar Journal مجلة جامعة ذي قار العلمية ISSN: ISSN: 27066894 (Online) ISSN: 27066908 (Print) Year: 2013 Volume: 8 Issue: 3 Pages: 178-187
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

A four stories concrete building has damage in most ground floor columns and it is considered unsafe for exploitation. In this paper, a method was explained and implemented to be the solution for this problem. The technique of repair consists, enclosing the existing ground floor damage column cross-section by reinforced concrete shell, contained longitudinal steel arrange around the existing column and transverse steel (stirrups) arrange along the existing column connected together by wire, and connect the additional longitudinal and transverse steel to original reinforced concrete damaged column by shear connectors. Finally covering with ordinary concrete. Reinforced concrete shell designed as compression member columns. By using this technique of repair, it can improve and increase the strength of ground floor columns to carry the applied loads with safety, more economic and accepted final look.

بناية هيكلية خرسانية ذات أربعة طوابق تعرضت أعمدتها بالطابق الأرضي إلى تدهور وتلف وسقوط الغطاء الخراساني لمعظم الأعمدة واعتبرت غير أمينة لإشغالها. تم في هذه الدراسة عرض طريقة إنشائية للمعالجة تمثلت بتغليف الأعمدة الخراسانية المتضررة بالخرسانة المسلحة, باستخدام هذا الأسلوب بالمعالجة فان مقطع العمود الأصلي المتضرر يتم أحاطته بهيكل خراساني مسلح بحديد تسليح طولي يتوزع على محيط العمود الأصلي وحديد تسليح أفقي(اتاري) منتشر على طول العمود الأصلي موزع بمسافات معينة حسب التصميم, ويرتبط حديد التسليح الإضافي الطولي والأفقي بالعمود الأصلي المتضرر بواسطة مسامير قص. تم تصميم الهيكل الخرساني المسلح كعنصر انضغاط لتحسين تحمل الأعمدة المتضررة.نتائج العمل والإنشاء بينت بان طريقة المعالجة ناجحة ولم تظهر أي تشققات جديدة حيث تم تحميل البناية بعد استكمال المعالجة ومنذ سنة حتى كتابة هذه الدراسة وقد تم استكمال الانهاءات بها. والآن المبنى يستخدم بشكل كامل وبأمان تام, وبكلفة اقتصادية مناسبة ومظهر نهائي مقبول من الناحية المعمارية.


Article
Impact Analysis of Reinforced Concrete Columns with Side Openings Subjected to Eccentric Axial Loads
التحليل الصدمي لأعمدة خرسانيه مسلحة حاوية على فتحات جانبيه ومعرضة لأحمال محورية لا مركزية

Authors: Nazar Kamil Ali أ.د. نزار كامل علي --- Ali Ihsan Salahaldin علي احسان صلاح الدين --- Ahmed Jabbar Hamza أحمد جبار حمزة
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2015 Volume: 21 Issue: 2 Pages: 1-19
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this research the behavior of reinforced concrete columns with large side openings under impact loads was studied. The overall cross sectional dimensions of the column specimens used in this research were (500*1400) mm with total height of (14000) mm. The dimensions of side openings were (600*2000) mm. The column was reinforced with (20) mm diameter in longitudinal direction, while (12) mm ties were used in the transverse direction. The effect of eccentric impact loads on the horizontal and vertical displacement for this column was studied. Nonlinear finite element analysis has been carried out using ready computer finite element package (ANSYS) to simulate the behavior of the reinforced concrete column with large side openings. Two load cases were considered in this investigation (C1, C2) with three different load values for each case. In the first case (C1) the loads was applied to one side of the column and in the second case (C2) the loads was applied to both sides. An Equilateral triangular load-time function was used for simulation the impact load results from gantry cranes supported by the column with total time duration (0.1 sec).In order to verify the analysis method, as no experimental data exist for comparing the obtained results, another analysis is made for tested conventional column under impact load at mid-height and good agreement has been obtained.For the above mentioned column, the maximum displacements were (33.3, 22.2) mm in the horizontal and longitudinal direction respectively, location of the maximum horizontal displacement was at the crown of the column. By comparing the results of the first loading case with the second one it is shown that in the horizontal direction, maximum displacement increases by (139%), (208%), and (147%) respectively, also the maximum vertical displacement increases by (150%), (172%), and (172%) respectively.

في هذا البحث تم دراسة سلوك عمود خرساني يحتوي على فتحات جانبية كبيرة (عمود ذو جزئين) تحت تأثير احمال صدمية لامركزية, حيث تم اعتماد عمود ذو مقطع (500*1400) ملم وبأرتفاع (14000) ملم ويحتوي على فتحات جانبية كبيرة بأبعاد (2000*600) ملم وتم تسليح العمود بأستخدام حديد بقطر 20 ملم في الاتجاة الشاقولي وقطر 12 ملم في الاتجاه العرضي .وتم دراسة تأثير تغير مقدار التحميل على الازاحه لهذا العمود.تم اعتماد التحليل اللاخطي بأستخدام طريقة العناصر المحدده وبالاستعانه ببرنامج (ANSYS) ليُحاكي تصرف العمود المحتوي على فتحات جانبيه وتم تسليط الاحمال بحالتين وكل حالة تحتوي على ثلاث قيم مختلفة للحمل ,حيث في الحالة الاولى تم التحميل من جانب واحد وفي الحالة الثانيه تم التحميل من جانبين, , وتم استخدام دالة حمل مثلثة الشكل متساوية الساقين لتمثيل الحمل الصدمي المسلط خلال فترة تحميل تبلغ (0.1) ثانيه.اكبر ازاحه تم الحصول عليها كانت (33.3) ملم مع المحور (X) و (22.2) ملم مع المحور (Y), وأن موقع اكبر ازاحه افقيه كان عند قمة العمود. وعند مقارنة النتائج لحالتي التحميل (التحميل من جانب واحد والتحميل من الجانبين) تبين ان نسبه الزياده في الازاحه الافقيه هي (139%, 208% , 147% )على التوالي, في حين ان نسبه الزياده في الازاحه العموديه هي (150%, 172%, 172%) على التوالي .


Article
Characteristic Performance of Deionized Columns

Authors: Mudhafar Y. Hussein --- Nahidh W. Kasser --- Matheel D. Al-Sabti
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2008 Volume: 9 Issue: 1 Pages: 35-43
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The reclamation of makeup water is studied in terms of breakthrough time (i.e., the leakage of the cations). Makeup water was subjected to lab-scale ion exchangers of two types: strong acid cation and weak base anion exchanger. The experimental investigation was directed to study the ion exchanger performance in terms of four different parameters (i.e., copper concentration, total dissolved solids (TDS), feed rate and bed depth). Box-Wilson composite rotatable design was adopted in designing the experiments. Breakthrough times of the effluent stream are measured in terms of copper concentration of 2 to 25 ppm, TDS concentration of 250 to 1250 ppm, feed rate of 0.38 to 5.34 l/h and bed depth of 5 to 70 cm. Simulation the effect of the studied variables through their pre-designed ranges in terms of breakthrough time was done by 2nd order polynomial equation. In general, the performance and characteristic of adopting two bed deionizers (cation and anion beds) was efficiently recommended to remove the ionic contaminants and not less than 95 % of wastewater is recycled.


Article
EFFECT OF BUCKLING LOADS ON MONOPANEL COLUMN SPECIMENS
تأثير قوى الا نبعاج على نماذج أعمدة المونوبنل

Author: Jenan Nea′mah Yasser al-Musawi جنان نعمة الموسوي
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2012 Volume: 5 Issue: 1 Pages: 27-37
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

A monopanel system is a new building material system of ferrocement that consists of two thin ferrocement block-like faces and thick layer of low strength, density and cost polystyrene foam insulation between them as a core. The simple structure idealization of monopanel system is that the core provides shear transfer between the faces that provide flexural resistance. Transverse trusses made of steel bars having diameter of (3.5) mm which serve as tie reinforcement to prevent the thin ferrocement layer from local buckling, have been used in this research and they are connected by inclined steel bar forming trusses shape making an angle equal to 60° with the longitudinal bars. The core material can be made of low cost materials such as aerated concrete, expanded polystyrene concrete, polystyrene foam, which is used in the present research work. Monopanel systems can be constructed on site or produced as precast units with very accurate and controlled dimensions. They can be used as walls, slabs, beams, columns and other types of similar construction. Such panels should therefore offer an excellent structural system not only for low cost housing but also for low-rise buildings (up to three stories) such as residential units. The main object of this research is to present an experimental investigation on the behavior and load carrying capacity of monopanel columns. The experimental work includes testing nine monopanel columns, and has been investigated the effect of a different depths of monopanel columns on the behavior and the ultimate load capacity. Also comparisons of these results with the ACI-318M-08 code formulations have been made.

نظام المونوبنل هو نوع من البناء الجديد الذي يتكون من طبقتين رقيقتين من الفيروسمنت تتخللهما طبقة سميكة من مواد عازلة ذات مقاومة وكثافة قليلتين وترتبط هاتين الطبقتين بواسطة عوارض مشبكة جملونيا مصنوعة من قضبان حديدية بقطر 3.5 ملم على هيئة قضبان طولية عدد2 تربطهما أخرى تميل بزاوية مقدارها 60 درجة مع القضبان الطولية ,هذه القضبان المائلة تقوم بمقاومة قوى القص المتولدة بين الوجهين من جراء تسليط الأحمال على أوجه وحدة المونوبنل المعرضة للأحمال.إن المادة التي تستعمل في لب المونوبنل ذات كلفة قليلة وهذه المادة قد تكون من غبار السمنت أو من خرسانة البولي ستارين أو رغوة البولي ستارين(الفلين) التي استخدمت في هذا البحث. يمكن صناعة المونوبنل في موقع العمل أو يكون مسبق الصب ويمكن السيطرة على مواصفاته و أبعاده بسهولة في كلا الحالتين. يمكن استخدام المونوبنل كجدران وبلاطات وأعمدة وكذلك كعتبات. هذا النظام لا يختص بالأبنية واطئة الكلفة فقط حيث يمكن تشييد الأبنية لغاية ثلاث طوابق مثل الوحدات السكنية والمدارس والمكاتب ومثيلاتها من الفنادق.لقد تناول هذا البحث دراسة سلوك والتحمل الأقصى للأعمدة المصنعة في المختبر بموجب نظام المونوبنل. ومن خلال التجارب العملية لتسعة نماذج لأعمدة المونوبنل تمت دراسسة تأثير أحمال الفشل بأختلاف عمق الاعمدة حيث تمت دراسة هذه المتغيرات على السلوك والحمل الأقصى للنماذج كذلك أظهرت النتائج انه بالإمكان استخدام علاقات مدونة من دليل الخرسانة الامريكي ACI-318M-08 لحساب القوى بشكل أمين لعتبات المونوبنل .

Keywords

Columns --- Ferro cement --- Monopanel --- Buckling


Article
Evaluation the Efficiency of Installing Stone Columns in Ground Improvement of Al-Nassiriya City Soil
تقييم كفاءة استخدام الاعمدة الحجرية في تحسين تربة مدينة الناصرية

Authors: Esraa Abdulaemma Mandhour --- Nesreen Kurdy Thabbah Al-Obaidy
Journal: University of Thi-Qar Journal for Engineering Sciences مجلة جامعة ذي قار للعلوم الهندسية ISSN: 26645564/26645572 Year: 2011 Volume: 2 Issue: 3 Pages: 44-56
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

This paper investigates the performance of stone columns in soft soil of Al-Nassiriya city (one of Iraqi cities in the south). A geotechnical study of physical and mechanical properties of the soil has been carried out for a selected areas from Al-Nassiriya city. A finitedifference Matlab program has been employed in simulation of installing stone columns in the aforementioned soil. Results of the study illustrate using stone columns reduces the settlement of the soil for different values of the modular ratio and replacement ratio, thusthe Wmax maximum settlement ratio changes from 30% to 16% of the modular ratios (E/E)=10 and 50 respectively. The effect of spacing and column width is taken intoconsideration.All results are reasonable and harmonic with most last studies.c-


Article
Strength Evaluation of Hybrid Reinforced Concrete Columns under Eccentric Loads

Authors: Ammar A. Ali --- Zaynab S. Mohammed
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2018 Volume: 36 Issue: 4 Part (A) Engineering Pages: 449-455
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This study presents an experimental investigation of the behavior of hybrid circular columns composed of outer precast reactive powder concrete (RPC) tubes filled with normal concrete (NC). The column specimens were subjected to an eccentric load producing both flexural and axial stresses within the section. The specimens consisting of 200 mm outer diameter with 400 mm height. The column specimens were divided into three groups, each group contains two specimens of thicknesses of outer RPC walls of 50 and 25 mm that filled with NC, in addition to RPC solid column section. The columns of first group were without any reinforcement. While the second group specimens were longitudinally reinforced, in addition to 180 mm spaced ties. The third group is composed of the same details as that of group two but with 90 mm ties spacing. The results show that, All RPC solid specimens give a higher load capacity from that of the hybrid specimens about 48%. It is noticed that increasing the RPC outer wall thickness improves the ultimate load capacity by 11% for hybrid specimens with 50 mm thickness wall than that of hybrid specimens with 25 mm thickness wall. Also, longitudinal and transverse reinforcement noticeably enhance the ductility and strength of the tested specimens compared with corresponding plain specimens.


Article
EXPERMENTAL STUDY OF PUNCHING SHEAR FOR REINFORCED CONCRETE FLAT PLATE SLABS WITH COUPLED COLUMNS
دراسة عملية للقص الثاقب للبلاطات الخرسانية المسلحة ذات اعمدة مزدوجة

Loading...
Loading...
Abstract

This study is conducted to investigate the punching shear of reinforced concrete flat plate slabs supported by coupled columns; sixteen specimens with average cube compressive strength (fcu) of (28 MPa) were tested.The slab specimens were made with (850x470x50mm) dimensions and concrete cover of (15 mm). The specimens were tested over a simply supported span (800 x 420mm) at four sides. The variables investigated in this study are the shape of column and the clear distance between columns of the slab specimen. The specimens are divided according to column shape into two groups, each group includes eight specimens.The first group (group A) has two square columns with cross sectional dimensions of (75x75mm) and height of (75mm) and column cross-sectional area equals to (5626mm). The clear distance between columns were varied from (2 mm) to (325 mm) (equals to 0.05d to 9.3d). While, the second group (group B) has two circular columns with (85mm) diameter and (75mm) height and column cross-sectional area equals to (5671)mm with variable clear distance between them from (2 mm) to (315 mm) (equals to 0.05d to 9d ).The test results showed that, the ultimate load reaches the maximum value when the distance between columns equal to (9.3d and 9d) for group (A) and (B) respectively; and decreases by (6.5 to 33.9%) and by (16.4 to 35.9%) of the maximum ultimate load when the clear distance between columns decreases by (7d to 0.05d) for group (A) and (B) respectively.The test results show that when the clear distance between columns is in the range of (0.05d to 7d) ,the failure zone is separated as one zone ;while when the clear distance between columns is equal to (9.3d and 9d ), the failure zone separates into two zones

اعدهذا البحث لدراسة القص الثاقب للبلاطات الخرسانية المسلحة ذات أعمدة مزدوجة ، تتضمن الدراسة صب ستة عشر نموذج من البلاطات (الصفائح) الخرسانية المسلحة باستخدام خلطة خرسانية واحدة بمعدل مقاومة انضغاط(fcu) مساوية إلى (28MPa) .ابعاد البلاطات متماثلة (الطول , العرض والسمك) والمساوية إلى (470,850 و 50ملم ) وبنفس الغطاء الخرساني والمساوي إلى (15ملم). تم فحص النماذج على فضاء بسيط الإسناد من جميع إضلاعه الأربعة وبإبعاد (420x800 ملم)، المتغيرات التي تم دراستها في هذا البحث هي شكل العمود والمسافة الصافية ما بين الأعمدة. تم تقسيم النماذج إلى مجموعتين (A) و (B) حسب شكل العمود وبواقع ثمان نماذج لكل مجموعة.أعمدة ألمجموعه ( A) لها مقطع عرضي مربع الشكل طول ضلعه (75 ملم ) ومساحة مقطعه تساوي(5625ملم2) وارتفاع العمود يساوي (75ملم ) والمسافة الصافية بين الأعمدة متغيرة من (2ملم ) إلى (325 ملم) أي ((0.05dإلى (9.3d), بينما أعمدة المجموعة (B) لها شكل دائري بقطر (85ملم(ومساحة مقطعه (5675ملم2) وارتفاع العمود يساوي (75ملم ) والمسافة الصافية بين الأعمدة متغيرة من (2ملم ) إلى (315 ملم) أي ((0.05dإلى (9d) .بينت نتائج الفحوصات أن حمل الفشل وصل إلى أعلى قيمة عندما أصبحت المسافة بين الأعمدة مساوية إلى ( 9.3dو 9d) للمجموعتين(AوB) على التوالي ، وتتناقص هذه القيمة بنسبة تتراوح بين (6.5-33%) و(16.4-35.9%) من أقصى حمل للفشل عندما تناقصت المسافة بين الأعمدة من (7d) إلى (0.05d).عندما تكون المسافة الصافية بين الاعمدة بحدود (0.05dالى 7d) بينت نتائج الفحوصات أن منطقة الفشل تنفصل عن البلاطة كجزء واحد، لكن عندما تكون المسافة الصافية ما بين الاعمدة بحدود ( 9.3dو 9d) للمجموعتين (A) و (B) على التوالي فأن منطقة الفشل تنفصل عن البلاطة كجزئين منفصلين

Keywords

Punching --- Shear --- Flexural --- flat plate --- coupled --- columns

Listing 1 - 10 of 98 << page
of 10
>>
Sort by
Narrow your search

Resource type

article (97)

journal (1)


Language

English (83)

Arabic and English (9)

Arabic (3)


Year
From To Submit

2020 (3)

2019 (5)

2018 (7)

2017 (10)

2016 (16)

More...