research centers


Search results: Found 7

Listing 1 - 7 of 7
Sort by

Article
Strategic framework of Relevant Cost Analysis
الاطار الستراتيجي لتحليل الكلف الملائمة دراسة نظرية تحليلية في المنظمات غير الهادفة للربح

Author: Mohammed H. Al-shujairi
Journal: Al-Rafidain University College For Sciences مجلة كلية الرافدين الجامعة للعلوم ISSN: 16816870 Year: 2009 Issue: 24 Pages: 26-40
Publisher: Rafidain University College كلية الرافدين الجامعة

Loading...
Loading...
Abstract

Traditionally, the relevant cost analysis is one of the best sources of cost information for short – terms management decision making. While , depending on this cost information without strategic vision considers a significant risk through its impact on long – term strategic planning in the context of business environment that addressed with complexly, high competition and the dominance oh strategic thinking . In this context , the aim of this research is to explain the nature of short- term management decision making process depended upon relevant cost analysis in term of strategic planning and that issues which adopted by organizations . This research has been depended on identifying variables and relationships among them in its theoretical context. While it depends quantification analytical on identifying this theme by non – profit organizations for specialization and importance of this activity in social and economy life, especially in Iraq.

يعد تحليل الكلف الملائمة تقليدياً ابرز مصادر المعلومات الكلفوية لعملية اتخاذ القرارات الادارية قصيرة الاجل ، فيما يعتبر الاعتماد على مصدر المعلومات هذا دون رؤية استراتيجية بالغ الخطورة في تاثيره على الخطط الستراتيجية طويلة الامد في ظل بيئة الاعمال التي تتسم بالتعقيد والتنافس الشديد وسيادة التفكير الستراتيجي . وفي اطار ذلك يستهدف البحث ايضاح طبيعة عملية اتخاذ القرارات الادارية قصيرة الاجل بالاعتماد على تحليل الكلف الملائمة في ظل المسائل والخطط الستراتيجية طويلة الاجل . ولتحقيق ذلك اعتمد البحث في اطاره النظري على ايضاح متغيراته والعلاقات فيما بينها . فيما تم اعتماد التحليل الكمي في تحقيق ذلك من خلال المنظمات غير الهادفة للربح لخصوصية واهمية مثل هذه الانشطة على الصعيد الاجتماعي والاقتصادي وفي العراق على وجه الخصوص


Article
Life-Cycle Cost Analysis for Three Different Types of A/C Systems Applied on an Apartment Located in a Multi-Floors Residential Tower in Mosul City
تحليل كلفة العمر الافتراضي لثلاث منظومات مختلفة لتبريد وتكييف الهواء لشقة متواجدة في برج سكني متعدد الطوابق في مدينة الموصل

Author: Badran Mohammed Salim
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 9 Part (A) Engineering Pages: 2134-1147
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This research studies the life cycle cost analysis using detailed cooling and electrical load profiles to calculate initial and running costs to evaluate the economic feasibilities of three different types of air conditioning systems as residential air conditioning system (RACs), commercial air conditioning system (CACs) and multi power air conditioning system (MPACs). The present-worth cost method for life-cycle cost period for ten (10) years analysis is applied to a sample building located in Mosul city / Iraq so as to select the best air conditioning system. The cooling load temperature differential with cooling load factor (CLTD/CLF) was used with hourly analysis program (HAP v4.6) for the estimation cooling load in each room of apartment.The results showed that the RAC system is lower than CAC and MPAC systems in initial cost approximately 53% and 67% respectively and the running cost for CAC system is lower than RAC and MPAC systems approximately 12% and 7% respectively for one month. The the total cost for two systems RAC and CAC are equal after 20 months of the beginning run and after even break point (BEP) the total cost for CAC system began to decline which indicates there is save in electric consumption and present worth cost over a period of (10) ten years after operation interval. The CAC system uses duct always to distribute air into each condition zone, therefor this system gives less noise of air distribution with best interior aesthetic appearance so that it fits with the interior decoration for each rooms of apartment. The outdoor unit of CAC system doesn’t appearance because the system working for long distances and can put outdoor units on the roof of the building.

يتضمن البحث الحالي تحليل كلفة العمر الافتراضي لثلاث منظومات مختلفة لتبريد وتكييف الهواء وكانت على النحو التالي منظومة تبريد وتكييف منزلية ومنظومة تبريد وتكييف تجارية ومنظومة تبريد وتكييف متعددة الاحمال حيث تم دراسة الكلفة الاولية والكلفة التشغيلية للمنظومات المختلفة بالاعتماد على مخطط الاحمال الحرارية والاحمال الكهربائية لنموذج شقة سكنية تقع في برج متعدد الطوابق في مدينة الموصل / العراق ، تم أعتماد طريقة فرق درجات حرارة مع عامل تصحيح حمل التبريد (CLTD/CLF) وبرنامج تحليل الساعات (HAP) أصدار (4.6) من شركة كاريير لحساب احمال التبريد الخاصة بالشقة السكنية. تم ملاحظة أن منظومة التبريد والتكييف المنزلية (RACs) تكون كلفتها الاولية اقل بمقدار 53% عن منظومة التبريد والتكييف التجارية (CACs) و67% عن منظومة التبريد والتكييف متعددة الاحمال (MPACs) وأن الكلفة التشغيلية لمدة شهر واحد فقط لمنظومة التبريد والتكييف التجارية هي أقـل من منظومة التبريد والتكييف المنزلية ومنظومة التبريد والتكييف متعددة الاحمال بمقدار 7% و 12% على التوالي، كذلك تم استنتاج أن منظومة التبريد والتكييف التجارية هي أفضل من ناحية الكلفة الكلية (المتمثلة بالكلفة الاولية والتشغيلية) لمدة تشغيلية مقدارها (10) عشر سنوات وأنه بعد مرور ((20 شهر من التشغيل الاولي للمنظومات الثلاث سيحدث تطابق في قيم الكلف الكلية لمنظومتي التبريد والتكييف التجارية والمنزلية وبعد تجاوز نقطة التطابق (EBP) سيتم عمل منظومة التبريد والتكييف التجارية مع ربح من ناحية الكلفة التشغيلية على مدار السنوات المتعاقبة وهذا يمثل الربح في اختيار هذا النوع من المنظومات الثلاث، فضلا عن ان منظومة التبريد والتكييف التجارية تستخدم مجرى هوائي دائماً لتمرير الهواء من الوحدة الداخلية وصولاً الى الحيز المراد تكييفه وبالتالي سيتم التحكم من خلال تصميم المجرى الهوائي بمقدار الضوضاء التي يصدرها الهواء الخارج من موزع الهواء لكل حيز مع وجود تناسق كبير بين اشكال والوان موزعات الهواء التي ستكون ملائمة مع التصميم الداخلي لكل حيز. إن منظومة التبريد والتكييف التجارية (CACs) تعمل لمسافات طويلة وبذلك سيكون من السهل جداً وضع الوحدة الخارجية على سطح البرج السكني وبالتالي المحافظة على المظهر الخارجي للبرج السكني .


Article
Economic Feasibility Study of Modern and Conventional Central Heating Systems for Villa Located in Duhok City, Iraq

Authors: B.M. Salim --- I.F. Abdulqadir --- F.M. Younis
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2017 Volume: 35 Issue: 7 Part (A) Engineering Pages: 725-736
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This research includes the evaluation of economic feasibilities based on the Iraqi’s market cost by using three different types of central heating systems in a residential villa located in Duhok city / Iraq. It also compares between modern and conventional central heating systems. A life cycle cost analysis based on detailed heating and operation load profiles considered in this work. Initial, running and maintenance costs for three central heating systems examined for fifteen years as a working period. The used systems in this study were; modern central heating system (heat pump water heater system) and conventional central heating system (fuel oil hot water boiler system and electric hot water boiler system). Transfer function method with hourly analysis program platform (HAP4.9) used for estimation the heating loads within each zone of the project. The proposed technique of modern central heating system found to be more efficient for thermal and economic efficiencies and it uses an environmentally friendly refrigerant such as (R410A). It also works efficiently in severe cold climate with low temperature of (-20°C) in winter season. The results shows that the heat pump water heater central heating system is most efficient system, this system has provided an energy saving range up to 57.5% compared with electric hot water boiler system and 70.6% compared with fuel oil hot water boiler system.


Article
COMPARATIVE ANALYSIS BETWEEN MODERN AND CONVENTIONAL HVAC SYSTEMS FOR USE AT COMMERCIAL BUILDING IN BAGHDAD CITY / IRAQ
تحميل مقارن لمنظومات التبريد والتكييف الحديثة والتقليدية لبناية تجارية في مدينه بغداد / العراق

Authors: Dr. Nabil J. Yasin د.نبيل جميل ياسين --- Badran M. Salim بدران محمد سالم
Journal: AL-TAQANI مجلة التقني ISSN: 1818653X Year: 2017 Volume: 30 Issue: 6 Pages: E47-E63
Publisher: Foundation of technical education هيئة التعليم التقني

Loading...
Loading...
Abstract

This research use the life cycle cost analysis and a detailed cooling, heating and electrical load profiles to determine the initial, running and maintenance costs for evaluation the economic feasibilities of using three different types of central air conditioning systems in a commercial building located in Baghdad city / Iraq, so as to select the best air conditioning system. The systems were modern air conditioning system (variable refrigerant flow), all air conditioning system (package roof top unit) and all water air conditioning system (fan coil unit). The present-worth cost method for lifecycle cost period for fifteen years analysis is applied. The transfer function method was used with hourly analysis program (HAP v4.9) for estimation the cooling and heating loads in each space of the building with adopted the indoor air quality in the design as adequate fresh air per person, acceptable noise level and air quality. The comparison between the different methods for the total cost (during fifteen years) for air conditioning systems showed that the variable refrigerant flow system has lowest total cost compare with other methods used for the period operation, so as the variable refrigerant flow air conditioning system worked into variable cooling and heating load between 0% and 100% of total load.

يتضمن البحث الحالي اجراء تحميل لكمفة العمر الافتراضي وحسابات احمال التبريد والتدفئه بالاضافه الى الأحمال الكهربائية لتحديد الكلفه الاوليه وكلفه الصيانه وكلفة التشغيل لثلاث أنواع مختلفة من منظومات التكييف المركزيه التي تعمل في نموذج لبنايه تجاريه )مول( تقع في مدينه بغداد/العراق. المنظومات كانت عمى النحو التالي منظومة تبريد وتكييف هواء مركزية نوع هواء كمي ومنظومة تبريد وتكييف هواء مركزية نوع ماء كمي ومنظومة تبريد وتكييف هواء مركزية حديثة. تم اعتماد طريقة دالات التحويل مع برنامج ) HAP ( نسخة 4.9 لأيجاد احمال التبريد والتدفئة الخاصة بكل حيز من المول مع الاخذ بنظر الاعتبار توفير شروط جودة الهواء الداخلي ) IAQ ( التي تخص توفير هواء نقي لكل شخص ويكون الهواء المجهز ذو نقاوة جيدة بالاضافة الى توزيع الهواء بدون ضوضاء تؤثر عمى راحة الانسان في داخل الحيز المشغول ، من خلال مقارنة الكلفة الكمية لمنظومات التبريد والتكييف المركزية وخلال مدة تشغيلية قدرها خمسة عشر عام تبين ان الاختيار الامثل والمناسب لهذا المشروع هو منظومة تبريد وتكييف هواء مركزية حديثة ) VRF (لانها تعمل حفظ لمطاقة وبالتالي تكون صرفيات الطاقة أقل من المنظومات الاخرى فضلا عن عمل المنظومة بحمل جزئي للتبريد او التدفئة متغيير يترواح بين % 0 الى 100 % ..


Article
Developing of Reliability-Centered Maintenance Methodology in Second Power Plant of South Baghdad

Authors: Amjad B. Adulghafour --- Ammar I. Abdulwahed
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2018 Volume: 36 Issue: 8 Part (A) Engineering Pages: 842-852
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Electric equipments of power station must be operated in the state of high reliability with its responsibility in the seamless power supply. Maintenance is one of the important and most costly phases in the lifecycle of any power generation systems, to improve maintenance management and system reliability and maintain the continuity of work of the system. Reliability-Centered Maintenance (RCM) is one of the most recent maintenance techniques. In this research, an enhanced RCM methodology based on quantitative relationships implemented at system component level and the overall system reliability was applied to identify the distribution components that are critical to system reliability. Only unit one of the Second Power Plant of South Baghdad were selected as a case study in this research application. The major contribution of the study is to create a maintenance plan through applying statistical, historical data to generate a failure probability distribution model by using the combined methods of Failure Mode of Effects and Criticality Analysis (FMECA) and Fault Tree Analysis (FTA). Evaluation criteria and matrixes of criticality are used to evaluate the criticality level of failure modes. The overall approach developed offers a cost-effective model, which can be applied prior to testing and inspection procedures during the RCM application. The results obtained from this case study show that the application of proposed RCM methodology based on preventive maintenance planning will decrease the total cost value of maintenance about 463469.85 $. That Indicates saving about 59% of the total downtime cost compared with current maintenance. As well as Proposed maintenance program reduce the required time to repair the plant components annually at a rate 6 day so that represent that the labor cost will minimized about 6424 $.


Article
دور النماذج الكمية في الجغرافية

Author: S.A Haifaa Abdel Kader Aziz Assist. prof . Huda Abdel Kader Aziz أ.م. هدى عبد القادر عزيز م.أقدم. هيفاء عبد القادر عزيز
Journal: Alustath الاستاذ ISSN: 0552265X 25189263 Year: 2018 Volume: 2 Issue: 227 Pages: 219-228
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The aim of this research is to highlight the importance of quantitative trends and statistical methods in geographies because of Based on the data of the General Company for the manufacture of grain for the quantity of rice production and the years of production and for the years (2009-2015), it was used to find the estimated and predictive value until 2020. Using two methods of analysis of comparative costs and assessing the qualitative factors determining the optimal location of the company's silates have been determined The best location is the Karbala silo in the first way, and the best location according to the method of assessing the factors was to Silo Hilla

يهدف هــــــذا الــــــبحث الى أبــــــــراز أهــــمــــــية الاتجاهــــات الكـــمية والـــــــــطـــــرق الاحصائــــية في الجـغـرافـية، لـــــما لها مــــــــن دور كبير في وصـــــف الظاهــــــرات الجغرافية المدروسة بالـــــدقـــــة العـــــلمية، وأيــــجاد الحلول المثلى لها ، وقـــــــد تــــم استعمال طـــريقتي الانحــــــــدار والاتــــباط وبــــالاعتـــــــماد على البيانات الخـــــاصة بــــالشــــركة العامة لـــــــــتـصنيع الحبوب لكــــمـــــية انــــــــتاج الرز، وســــنـــــوات الانتاج، ولاعوام (2009-2015) , لايــــــجاد القيمة الـــتقديــــــــرية والتنبؤية حــــــــــتى عـــــــام 2020، كما تـــــــــــم استعمال طريقتي تحليل الكلف المقارنه، وتــــــقـــييم العوامل الــــنـــــوعــيـــة التحديد الموقع الامثل السايلوات الشركة، وقد تم تحديد أفضل موقع هو سايلو كربلاء بطريقة الاولى ،أما أفضل موقع حسب طريقة تقييم العوامل ، يفكان لسايلو الحلة


Article
Building Information Modeling (BIM) as Economical and Properties Assessment Tool for Building Units Alternatives Made with Lightweight Foamed Concrete

Authors: Abbas M. Abd عباس مهدي عبد --- Dunya S. Jarullah
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2018 Volume: 11 Issue: 2 Pages: 33-41
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

Lightweight foamed concrete brick is new construction materials. It gives a prospective solution to building construction industry, this research aims to study the cost, dead loads, environmental issues and energy consumption from using lightweight foam concrete bricks as construction materials by utilizing building information modeling technique. The results obtained from this modelling proved that the cost of brick work using lightweight foamed concrete units of grade A (2000 kg/m3) and B (1800 kg/m3) is higher by (19.4% and 11.9%) respectively than the activity cost using traditional fired clay bricks. For grade C (1600 kg/m3) that cost was very close to fired clay bricks (+2.9%). while the construction of brick work using light weight foamed concrete units of grade D (1400 kg/m3) and E (1200 kg/m3) was lower by (8% and 18.6%) than fired clay bricks. Besides that, the dead load generated by building units was decreased by (7.7-38.5%) for grade (B, C, D, E) than the load of fired clay bricks, while the load generated from used lightweight foam concrete bricks grade is very closed to fired clay bricks (+2.5%). There was a reduction in energy consumption by the rate of (4.1-62.2%) for heating and (9.8-73.4%) for cooling as wall sharing in energy consumption. Environmental analysis showed sustainable potential so that the production of lightweight foamed concrete units reduces CO2 emission by (46.5-67.9%) compared with the fired clay bricks. Finally; it can be concluded that building units produced in this research with LWFC, characterized with properties can efficiently compete the fired clay bricks.

Listing 1 - 7 of 7
Sort by
Narrow your search

Resource type

article (7)


Language

English (5)

Arabic (2)


Year
From To Submit

2018 (3)

2017 (2)

2014 (1)

2009 (1)