Transient stability Assessment using Artificial Neural Network Considering Fault Location

Authors: P.K.Olulope --- K.A.Folly --- S.Chowdhury --- S.P.Chowdhury
Journal: Iraqi Journal for Electrical And Electronic Engineering المجلة العراقية للهندسة الكهربائية والالكترونية ISSN: 18145892 Year: 2010 Volume: 6 Issue: 1 Pages: 67-72
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

This paper describes the capability ofartificial neural network for predicting the criticalclearing time of power system. It combines theadvantages of time domain integration schemes withartificial neural network for real time transientstability assessment. The training of ANN is done usingselected features as input and critical fault clearingtime (CCT) as desire target. A single contingency wasapplied and the target CCT was found using timedomain simulation. Multi layer feed forward neuralnetwork trained with Levenberg Marquardt (LM)back propagation algorithm is used to provide theestimated CCT. The effectiveness of ANN, the methodis demonstrated on single machine infinite bus system(SMIB). The simulation shows that ANN can providefast and accurate mapping which makes it applicable toreal time scenario


Article
Calculation the Critical Clearing Time CCT for Iraqi super grid in a fast manner of three - phase fault
حساب زمن الازالة الحرج CCT لمنظومة العراق الفائقة بطريقة سريعة لعطل ثلاثي الاطوار

Author: Inas Jabbar Mohammed
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2019 Volume: 17 Issue: 1 Pages: 38-53
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

This paper describes the use of direct method (Relative Unstable Equilibrium Point method (RUEP)) to evaluate the Critical Clearing Time (CCT) of power system subjected to large contingencies. The main aim is to reduce the execution time of the process of finding of the Critical Clearing Time for transient stability analysis, this method runs fast but with poor accuracy due to the over-simplification of component models; the time-domain simulation method is accurate but time- consuming. Results of the (RUEP) method applied on the simulation examples and actual system calculation are analyzed, and the range of error is discussed. Via complementarity of direct method and time-domain simulation method, a new crossbred method is proposed: in the calculation of the critical clearing time, the result of the direct method is used as the initial value and then the time-domain simulation method is employed for further search, which can meet the requirements of transient stability in terms of accuracy and speed. The results obtained by two methods show that the proposed method reduces the execution time of the Central Processing Unit about 8-10 times. In this paper the CCT was calculated for power system 400kvIraq Super Grid.

يصف هذا البحث استخدام الطريقة المباشرة (طريقة نسبة عدم توازن نقطة عدم الاستقرارية ((RUEP) لتقدير زمن الازالة الحرج لمنظومة قدرة خاضعة لحالة عطل كبير. الهدف من ذلك تقليل الزمن المستغرق في عملية ايجاد زمن الازالة الحرج من اجل تحليل الاستقرارية العابرة , تمتاز هذه الطريقة بكونها سريعة لكنها تفتقر الى الدقة المتناهية بسبب التبسيط لمكونات منظومة القدرة , طريقة محاكاة المجال الزمني دقيقة ولكنها تستغرق وقتا طويلا.النتائج المطبقة من طريقة RUEP)) لامثلة من مظومة حقيقية تم احتسابها و تحليلها مناقشة نسبة الخطأ. عن طريق اقتراح طريقة جديدة لكلا من الطريقة المباشرة وطريقة المحاكاة المجال الزمني ,الطريقة الهجينة الجديدة: في حساب زمن الازالة الحرج ,النتائج المستخدمة من الطريقة المباشرة كقيم اولية و ثم يتم استخدام طريقة محاكاة المجال الزمني لمزيد من البحث ,والتي يمكن أن تلبي متطلبات الاستقرارية العابرة من حيث الدقة والسرعة. تظهر النتائج التي تم الحصول عليها بواسطة طريقتين أن الطريقة المقترحة تقلل من وقت تنفيذ وحدة المعالجة المركزية حوالي 8-10 مرات.في هذا البحث ال(CCT) المحسوب لمنظومة قدرة شبكة العراق االفائقة (400KV).