research centers


Search results: Found 6

Listing 1 - 6 of 6
Sort by

Article
Synthesis, Characterization of New Polyamides Bearing Triarylamine for Lightemitting Diodes

Journal: Ibn Al-Haitham Journal For Pure And Applied Science مجلة ابن الهيثم للعلوم الصرفة والتطبيقية ISSN: P16094042/ E25213407 Year: 2019 Volume: 32 Issue: 1 Pages: 80-100
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this work, new di-acid monomers 4, 4’-di-carboxillic-4”-bromo-2”, 6”-dimethyl triphenylamine (Ma),4, 4’- di-carboxylic -4”-chloro-2”, 6”-dimethyl triphenylamine (Mb) and 4, 4’- di-carboxylic -2”,4”-dichloro-6”-methyl triphenylamine (Mc) were synthesized by reaction of p-cyanobenzofluride with threedifferent aromatic amines (4-bromo,2,6-dimethyl aniline, 4-chloro,2,6-dimethyl aniline and 2,4 dichloro,6- methyl aniline ) via aromatic nucleophilc substitution method to form three di cyano intermediates 4,4’-Dicyano-4”-bromo-2”, 6”-dimethyl triphenylamine (Da), 4, 4’-dicyano-4”-chloro-2”, 6”-dimethyltriphenylamine (Db) and 4, 4’-dicyano-2”,4”-dichloro-6”-methyl triphenylamine (Dc) which form final dicarboxylicmonomers after alkaline hydrolysis. Finally, these monomers react with two different aromaticdi amines, phenylene diamins and benzidine respectively via polycondensation reaction to form finalpolyamides 4"-bromo-2", 6"-dimethyl-triphenylamine-4, 4'-polyphenylbenzamide (Pa), 4”-chloro-2”,6”-dimethyl- triphenylamine-4,4'-polyphenylbenzamide (Pb), 2”,4”-dichloro-6”-methyl-triphenylamine 4,4'-polyphenylbenzamide (Pc),4"-bromo-2",6"-dimethyl triphenylamine-4,4'- polyphenylbiphenylamide (Pd),2”,4”-dichloro-6”-methyl-triphenylamine-4,4’-polyphenylamide (Pf). The chemical structure of thesepolymers characterized by FTIR and NMR techniques. All the results of polyamides showed excellentsolubility in most polar solvents to form strong thin films. The polyamides possess a good thermalstability with height glass transition temperatures (Tg). Polyamides in DMSO solvent gave strongphotoluminescence PL. Thin casting films of these polyamides in cyclic voltammetry (C.V) onglass base of iridium-tin oxide (ITO) as working electrode in dry CH3CN solvent contains 0.1 Mof tetrabutylantimoneperchlorate (TBAP) as an Electrolyte gave one redox wave


Article
Grafted Polymer with Nano Materials (CNT, C60 and Activated Carbon) Using As Working Electrodes in CyclicVolta metric Technique
تعديل البوليمر المطعم بمواد نانوية (الكاربون نانوتيوب والكاربون60 والكاربون المنشط) واستخدامه في الاقطاب العاملة في تقنية الفولتامتري الحلقي

Authors: Muhammed Mizher Radhi --- Tan Wee Tee
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 3 Part (B) Scientific Pages: 584-594
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

A crylonitrile was grafted on polystyrene and modified with nano materials such as CNT, C60 and activated carbon using gamma-irradiation technique. This process was carried out at various gamma doses 0.2-1.5 Mrad (0.002-0.015 MGry) and used different percentage (w/w %) of monomer (Acrylonitrile) and catalyst ferrous ammonium sulfate (FAS). The new grafted polymer modified with nanometrials has good physical and chemical properties of hardness, insolubility, and stability. Also the sensitivity under conditions of cyclic voltammetry is significantly dependent on pH, electrolyte and scan rate. The grafted polymer modified with nano materials was used in different applications in electrochemistry such as in cyclic voltammetric technique by fabrication of working electrodes from these materials as a substitute of glassy carbon electrode, platinum electrode, gold electrode…etc. and self modified these electrodes with nanomaterials.

تم تعديل البولي ستايرين المطعم بالاكريلونايترايل بمواد نانوية مثل الكاربون نانوتيوب والكاربون 60 والكاربون المنشط باستخدام تقنية التشعيع باشعة كاما. حيث استخدمت اشعة كاما بجرع مختلفة 0.2-1.5 Mrad (0.002-0.015 MGry). تم استخدام نسب مختلفة من المونومير (الاكريلونايترايل) ومن العامل المساعد كبريتات الامونيوم الحديدية. حيث تم الحصول على بوليمر مطعم ومعدل بمواد نانوية اكسبته صفات فيزياوية وكيمياوية جيدة من حيث الصلابة والثبوتية والذوبانية والاستقرارية وكذلك تحسسه العالي لتقنية الفولتامتري الحلقي في دراسة الحامضية المختلفة والمذيبات المختلفة وسرع المسح المختلفة. وتم استخدام هذه البوليمرات المطعمة في تطبيقات الكيمياء الكهربائية بتقنية الفولتامتري الحلقي وذلك بتصنيع الاقطاب العاملة كبديل للاقطاب العاملة التجارية مثل قطب الكاربون الزجاجي والبلاتين والذهب وغيرها. كذلك يمكن استخدام هذه الاقطاب كاقطاب عاملة ومعدلة ذاتيا بالمواد النانوية.


Article
Electrochemical Investigation of Lignin Resin Doped with Different Ratios Rhodamine B
دراسة السلوك الكهروكيميائي لراتنج اللكنين المشوب بنسب مختلفة بصبغة الرودامين ب

Author: Samah Hussein Kadhim سماح حسين كاظم
Journal: Univesity of Thi-Qar Journal مجلة جامعة ذي قار العلمية ISSN: 66291818 Year: 2018 Volume: 13 Issue: 1 Pages: 25-42
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

The electrochemical behavior was investigated of Lignin Resin by using the cyclic voltammetry technique. Such investigation mainly focuses on the expected properties of the doped resin with different doping ratios of Rhodamine B (0.01, 0.5, 0.1, 0.15, 0.2) %wt. This is indicated by the electron transfer between the dopant and resin, which clearly shows the appearance of oxidation – reduction peaks accompanied log increase in electrical current Ip as applied potential changes. The heights of Ip oscillate due to the change in scan rate . The results of linear of relationships between Ip with 1/2 indicated that the electron transfer was a process of one electron transfer

تضمن البحث دراسة السلوك الكهروكيميائي لراتنج اللكنين بوساطة تقنية المسح الجهدي الحلقي، وتم التركيز على خواصه المتوقعة بعد التشويب بصبغة الرودامين ب بنسب (0.01, 0.5, 0.1, 0.15, 0.2) %wt وذلك وفقا لما يسببه الانتقال الالكتروني بين الصبغة المشوبة وراتنج اللكنين حيث انعكس ايجابيا على ظهور واضح لقمم التأكسد والأختزال رافق ذلك زيادة في قيم التيار الكهربائي (Ip) لمدى تغيير الجهد الكهربائي المسلط اذ تفاوتت وفقا لاختلاف سرع المسح الجهدي المطبقة والمتوقعة أصلا في هذه الحالات. ان نتائج العلاقة الخطية المستنبطة بين Ip والجذر التربيعي لسرعة المسح الجهدي 1/2 دلت على أن الانتقال الالكتروني هو عملية أنتقال الكترون واحد.


Article
A study of electrochemical behavior for redox peaks of Pb(II) ions in human blood samples using Nanosensor
دراسة السلوك الكهروكيميائي لقمتي الاكسدة – الاختزال لايونات الرصاص لعينات من دم الانسان باستخدام المتحسسات النانوية

Author: Muhammed Mizher Radhi محمد مزهر راضي
Journal: Albahir journal مجلة الباهر ISSN: 23125721 Year: 2017 Volume: 5 Issue: 9+10 Pages: 63-73
Publisher: AL-Abbas Holy Shrine العتبة العباسية المقدسة

Loading...
Loading...
Abstract

The electrochemical method using cyclic voltammetrictechniquewas determined the effect ofhigh temperature on the redox current peaks of one of pollutant in an environment are lead ionsin vitro for humanblood medium. The present study showed the effect of different temperatureson the lead ions in blood medium by analysis cyclic voltammetric analysis and determinationthe chemical thermodynamic factors. It was usedmultiwall carbon nanotube (MWCNT) / glassycarbon electrode (GCE),modified working electrode (MWCNT/GCE) as a good sensor to detectionthe effect of different temperatures on the blood medium in presence of Pb(II) ions.The results was confirmed that oxidation and reduction current peak of Pb(II) ions at -(0.5)V and (0.11)V,respectively at low temperature (20)oCand monitoring the redox current peaksagainst increasing the temperature until (60)oC. It was found that the anodic current peak of leadions in blood medium was decreased with increasing temperature, but cathodic current peak wasenhanced about three times at high temperature (60) oC. Thus, the activation energy (E*) valueswere determined from Arrhenius equation for oxidative peak is (-15.541) kJ.mol-1.K-1and foranti-oxidative peak is (35.271) kJ.mol-1.K-1Other thermodynamic functions such as change inEnthalpy of activation (ΔH*), change in Gibbs of activation (ΔG*) and change in Entropy ofactivation (ΔS*) were determined byEyring equation. The results enhanced the blood of peoplepollutant with lead ions was significant affectedby environment or exposure with different sourceof high temperature such as workers in factories by complexation with the blood componentandcauses to precipitation of heavy metal (Pb) on the brain by the reduction process of Pb(II)/Pb(0)which may be causes different disease such asAlzheimer in adults or Autism in infants.

تم استخدام تقنية الفولتامتري الحلقي في دراسة الكيمياء الكهربائية لايجاد تاثير درجات الحرارة العالية على قمتي التيارالكهرباثي للاكسدة والاختزال لاحد الملوثات الطبيعية لمحيط الدم في الانسان وهو ايون الرصاص.الدراسة الحالية هو لمعرفة تاثير درجات الحرارة المختلفة على ايونات الرصاص في وسط الدم باستخدام التحليل بجهازالفولتامتري الحلقي وايجاد العوامل الكيميائية الثرموداينميك.تم استخدام متعدد الطبقات للكاربون نانوتيوب في تعديل الاقطاب العاملة الكاربون الزجاجي كمتحسسات نانوية وذلكللكشف عن تاثيرات درجات الحرارة العالية المختلفة على وسط الدم بوجود ايون الرصاص بتقنية الفولتامتري الحلقي.اكدت نتائج قمتي الاكسدة والاختزال لايونات الرصاص عند الجهد الكهربائي( 0.5 -) و ( 0.11 ) فولت على التوالي عنددرجة حرارة منخفضة ( 20 ) درجة مئوية ومراقبة هذه القمم بزيادة درجة الحرارة الى ( 60 ) درجة مئوية. لقد وجد بان قمة التيارالكهربائي الانودية لايون الرصاص في محيط الدم تقل بزيادة ارتفاع الحرارة، ولكن القمة الكاثودية تزداد ثلاثة اضعاف بارتفاعالحرارة الى ( 60 ) درجة مئوية. لذا فان طاقة التنشيط المستخرجة من معادلة ارينيوس لقمة الاكسدة هي￯ اما قيم الثرمواينمك الاخر kJ.mol-1.K-1 ( وقيمتها لقمة الاختزال هي ( 35.271 kJ.mol-1.K-1 (-15.541)مثل تغير الانثالبي المنشط و تغير جبس المنشط و تغير الانتروبي المنشط تم ايجادها باستخدام معادلة ايرنج.لقد دعمت النتائج من الاشخاص الملوثين بايونات الرصاص وتاثرها بدرجات حرارية عالية نتيجة التعرض لاسباب البيئيةكما في العاملين في المصانع وذلك بتكوين المعقد بين ايون الرصاص وتركيبة الدم مما يسبب ترسب ايون الرصاص على الدماغ نتيجةاختزال ايون الرصاص الى عنصر الرصاص مما تسبب امراض مثل الزهايمر الذي يصيب الكبار او التوحد كما في الصغار.


Article
Voltammetric characterization of polystyrene grafted with acrylonitrile electrode self modification with carbon nanotube (Psgacesmcnt)
التشخيص الفولتامتري لقطب البولي ستيرين المطعم اكرلوناترال والمعدل ذاتي بالكاربون نانوتيوب

Authors: Emad A. Jaffar Al-Mulla عماد عباس جعفر --- Muhammed Mizher Radhi محمد مزهر راضي
Journal: Albahir journal مجلة الباهر ISSN: 23125721 Year: 2015 Volume: 1 Issue: 1,2 Pages: 35-43
Publisher: AL-Abbas Holy Shrine العتبة العباسية المقدسة

Loading...
Loading...
Abstract

Abstract A novel self modification of grafted polystyrene-acrylonitrile working electrode with carbon nanotubes was success for fabrication from grafting polymer via gamma irradiation and ferrous ammonium sulfate (FAS) as a catalyst. The electrochemical properties of the self modified grafted polymer with CNT (PSGACESMCNT) improved performance the working electrode at higher conducting surface was done through using in cyclic voltammetry (CV). Morphology of the surface of PSGACESMCNT was characterized by AFM and ASM. The characterization of electrocnductivity properties of PSGACESMCNT was studied in 1M of KCl with different concentration of K3 [Fe(CN)6], at different scan rates, temperature, and different concentrations using CV technique. The new PSGACESMCNT improved performance the working electrode in CV at different techniques such as rotating disc electrode (RDE). also, the nanomaterials in the chain of grafted polymer was enhanced the redox current peaks of Fe (II)/Fe (III) multi times than at commercial working electrodes such as GCE, Pt-electrode, Au-electrode…. etc.

ﺍﳋﻼﺻﺔ ﺗﻢ ﺗﺼﻨﻴﻊ ﻗﻄﺐ ﺟﺪﻳﺪ ﻣﺼﻨﻊ ﻣﻦ ﺍﻟﺒﻮﱄ ﺳﺘﲑﻳﻦ ﺍﳌﻄﻌﻢ ﺍﻛﺮﻟﻮﻧﺎﺗﺮﺍﻝ ﻭﺍﳌﻌﺪﻝ ﺑﲈﺩﺓ ﺍﻟﻜﺎﺭﺑﻮﻥ ﻧﺎﻧﻮﺗﻴﻮﺏ ﻭﺑﺎﺳﺘﺨﺪﺍﻡ ﺍﺷﻌﺔ ﻛﺎﻣﺎ ﻭﺍﻟﻌﺎﻣﻞ ﺍﳌﺴﺎﻋﺪ ﻛﱪﻳﺘﺎﺕ ﺍﻻﻣﻮﻧﻴﻮﻡ ﺍﳊﺪﻳﺪﻳﺔ. ﺗﻢ ﺩﺭﺍﺳﺔ ﺍﻟﺼﻔﺎﺕ ﺍﻟﻜﻬﺮﻭﻛﻴﻤﻴﺎﺍﺋﻴﺔ ﻟﻠﻘﻄﺐ ﺍﳌﺼﻨﻊ ﺣﻴﺚ ﺍﻋﻄﻰ ﲢﺴﻴﻨﺎﹰ ﰲ ﺍﺩﺍﺀﻩ ﻭﺫﻟﻚ ﻋﻦ ﻃﺮﻳﻖ ﺍﺳﺘﺨﺪﺍﻡ ﺍﻟﻜﺎﺭﺑﻮﻥ ﻧﺎﻧﻮﺗﻴﻮﺏ ﺍﻟﺬﻱ ﻳﺰﻳﺪ ﰲ ﺍﻟﺘﻮﺻﻴﻠﻴﺔ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﳌﺎﺩﺓ ﺍﻟﺒﻮﻟﻴﻤﺮ ﺍﳌﻄﻌﻢ ﺍﺛﻨﺎﺀ ﺍﺳﺘﺨﺪﺍﻣﻪ ﰲ ﺟﻬﺎﺯ ﺍﻟﻔﻮﻟﺘﺎﻣﱰﻱ .ﻭﻛﺬﻟﻚ ﺗﻢ ﺍﺳﺘﺨﺪﺍﻡ ﳏﻠﻮﻝ AFM ﻭSEMﺍﳊﻠﻘﻲ. ﻭﻗﺪ ﺗﻢ ﺗﺸﺨﻴﺺ ﺍﻟﺼﻔﺎﺕ ﺍﻟﺴﻄﺤﻴﺔ ﻟﻠﻘﻄﺐ ﺍﳉﺪﻳﺪ ﺑﺎﺳﺘﺨﺪﺍﻡ ﻛﲈﺩﺓ ﻗﻴﺎﺳﻴﺔ ﰲ ﺟﻬﺎﺯ ﺍﻟﻔﻮﻟﺘﺎﻣﱰﻱ ﺍﳊﻠﻘﻲ ﰲ ﺗﺸﺨﻴﺺ ﺍﻟﺼﻔﺎﺕ ﺍﻟﻜﻬﺮﻭﻛﻴﻤﻴﺎﺋﻴﺔ ﻟﻠﻘﻄﺐ. K3Fe(CN)6 K3] ﻭﺑﱰﺍﻛﻴﺰ ﳐﺘﻠﻔﺔ ﻝ KCl ﻣﻮﻻﺭﻱ ﻣﻦ 1 ﺩﺭﺳﺖ ﰲ GPESMCNTﺧﻮﺍﺹ ﺍﻟﺘﻮﺻﻴﻞ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ ﻝ .CV [ ﻭﻋﻨﺪ ﺩﺭﺟﺎﺕ ﺣﺮﺍﺭﺓ ﳐﺘﻠﻔﺔ ﺑﺎﺳﺘﺨﺪﺍﻡ ﺗﻘﻨﻴﺔ Fe(CN)6 ﻭﻗﺪ ﻟﻮﺣﻆ ﺃﻥ ﺍﻟﻘﻄﺐ ﺍﳉﺪﻳﺪ ﺳﺎﻋﺪ ﰲ ﲢﺴﲔ ﺃﺩﺍﺀ ﺗﻘﻨﻴﺔ ﺍﻟﻔﻮﻟﺘﺎﻣﱰﻱ ﺍﳊﻠﻘﻲ ﺧﺎﺻﺔ ﰲ ﺍﺳﺘﺨﺪﺍﻣﻪ ﺑﺘﺠﺮﺑﺔ ﺍﻟﻘﻄﺐ ﺍﻟﺪﻭﺍﺭ ﺍﻟﺘﻲ ﻻ ﻳﻤﻜﻦ ﺍﺳﺘﺨﺪﺍﻡ ﺍﻷﻗﻄﺎﺏ ﺍﳌﻌﺪﻟﺔ ﻓﻴﻪ. ﺍﻥ ﻧﺘﺎﺋﺞ ﺍﻟﻘﻴﺎﺱ ﺍﻭﺿﺤﺖ ﺍﻥ ﺍﳌﺎﺩﺓ ﺍﻟﻨﺎﻧﻮﻳﺔ ﳍﺎ ﺍﳘﻴﺔ ﰲ ﺗﺮﻛﻴﺒﺔ ﺍﻟﺒﻮﻟﻴﻤﺮﺍﳌﻄﻌﻢ ﺑﺮﻓﻊ ﻗﻴﻤﺔ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ ﻟﻘﻤﺘﻲ ﳌﺮﺕ ﻋﺪﻳﺪﺓ ﻣﻘﺎﺭﻧﺔ ﻣﻊ ﺍﻻﻗﻄﺎﺏ ﺍﻟﺘﺠﺎﺭﻳﺔ ﻣﺜﻞ ﻗﻄﺐ ﺍﻟﻜﺎﺭﺑﻮﻥ Fe (II)/Fe (III)ﺍﻻﻛﺴﺪﺓ ﻭﺍﻻﺧﺘﺰﺍﻝ ﻟﻠﺤﺪﻳﺪ ﺍﻟﺰﺟﺎﺟﻲ ﻭﻗﻄﺐ ﺍﻟﺒﻼﺗﲔ ﻭﻗﻄﺐ ﺍﻟﺬﻫﺐ.


Article
Physical and Electrical Study of Different Carbone Nanomaterials as Modifying Material for SPCE

Author: Issam A. Latif
Journal: Iraqi National Journal Of Chemistry المجلة العراقية الوطنية لعلوم الكيمياء ISSN: 22236686 Year: 2016 Volume: 16 Issue: 4 Pages: 186-203
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

In this work was prepared three different types of modified screen printed carbon electrode (SPCEs) with drops casted method, the used carbone nanomaterials were the MWCNT, functionalized –MWCNT (f-MWCNT) and After several experiments were made to find an appropriate ratio to make good GOT/f-MWCNT nanocomposite, and found the suspension mixture (1:1) from GOT/f-MWCNT (f-MWCNT-GOT). The electrical and physical properties were performed with cyclic voltammeter technique, and studied the maximum current response, the effective surface area, effect of the pH value and the determination of active surface area for MWCNT-SPCE , f-MWCNT-SPCE and f-MWCNT-GOT/SPCE as (0.04 cm2), (0.119 cm2) and (0.115 cm2) respectively, the surface coverage concentration ( Γ) of the material on each area was calculated and was 9.447×10-10, 9.449×10-10 and 9.3×10-10 mol cm–2 ,for MWCNT ,f-MWCNT and f-MWCNT-GOT respectively, The values of Γ for all three types of electrodes were almost the same and no noticeable difference. These electrodes were used to study the electrochemical behavior of organic compound which consisting an amide functional group, these group founded in huge spectrum of pesticide and medicine compounds etc. the penicillin antibiotic drug family has a β-lactam group (Azetidine-2-one) group. Therefore it was expected to show hydrolysis with opening of the four membered ring azetidine-2-one, in a H+/1ē process. In this work used ampicillin antibiotic AMP. The cyclic voltammetry investigation was shown the signals of anodic peak current were higher than the cathodic current signals Ipa/Ipc≠ 1, which indicated an irreversible electrode reaction, with differential pulse voltammetry was studded the limit of detection (LOD), the modification of SPCE with the f-MWCNT-GOT show the best result than the other two carbone nanomaterial MWCNT and f-MWCNT.

Listing 1 - 6 of 6
Sort by
Narrow your search

Resource type

article (6)


Language

English (5)


Year
From To Submit

2019 (1)

2018 (1)

2017 (1)

2016 (1)

2015 (1)

More...