SIMULATION MODEL FOR THE ASSESSMENT OF DIRECT AND INDIRECT GEOREFERENCING TECHNIQUES IN ANALYTICAL PHOTOGRAMMETRY

Authors: B. Saleem --- H. Alwan --- L. Khalid
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2011 Volume: 17 Issue: 6 Pages: 1633-1642
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This paper compares between the direct and indirect georeferencing techniques in Photogrammetry bases on a simulation model. A flight plan is designed which consists of three strips with nine overlapped images for each strip by a (Canon 500D) digital camera with a resolution of 15 Mega Pixels. The triangulation computations are carried out by using (ERDAS LPS) software, and the direct measurements are taken directly on the simulated model to substitute using GPS/INS in real case. Two computational tests have been implemented to evaluate the positional accuracy for the whole model and the Root Mean Square Error (RMSE) relating to (30) check points show that the indirect georeferencing is more accurate than the direct georeferencing. The computed RMSE of indirect georeferencing technique are (±0.0686 m., ± 0.0402 m.±, 0.3583 m.) in (X, Y, Z) respectively, while by direct georeferencing technique are (±0.1274 m., ± 0.1220 m., ± 0.5132 m.) in (X, Y, Z) respectively. Finally, the aim of this paper can be summarized as investigating the possibilities of using a simulation model to evaluate the applicability of direct and indirect georeferencing and analyzing the accuracy of both techniques

يقارن البحث بين تقنيتي الإرجاع الأرضي ((georeferencing المباشر وغير المباشر في المسح التصويري اعتمادا على موديل محاكاة, حيث صممت خطة الطيران لتضم ثلاثة خطوط طيران بواقع تسع صور في كل خط وبتداخل أمامي وجانبي بين الصور الملتقطة باستخدام كاميرا رقمية نوع (Canon 500D) ذات دقة تمييز صورية (15 Mega Pixels) . إن حسابات التثليث أجريت باستخدام برنامج (ERDAS LPS) في حين أخذت القياسات على نموذج المحاكاة مباشرة للتعويض عن استخدام (GPS/INS) في الحالة الواقعية.لتثمين الدقة الموقعية لكل النموذج تم حساب جذر معدل مربع الخطأ (RMSE) اعتمادا على (30) نقطة تدقيق وبتطبيق اختبارين حسابيين , وجد أن تقنية الإرجاع الأرضي غير المباشر أدق من تقنية الإرجاع الأرضي المباشر. لأن نتائج جذر معدل مربع الخطأ في التقنية غير المباشرة كانت ± 0.3583 m.) , (±0.0686 m., ± 0.0402 m. في (X, Y, Z)على التوالي , بينما كانت النتائج في التقنية المباشرة (±0.1274 m., ± 0.1220 m., ± 0.5132 m.) في (X, Y, Z)على التوالي أيضاَ. وبذلك يتلخص الهدف من البحث في إمكانية استخدام نموذج المحاكاة لتقييم تقنيتي الإرجاع الأرضي المباشر وغير المباشر عن طريق حساب جذر معدل مربع الخطأ(RMSE ) بكلا التقنيتين ومقارنة دقتيهما


Article
The role of some oxidative stress and inflammatory factors in essential hypertension
دور بعض الضغوط المؤكسدة والعوامل الالتهابية في ارتفاع ضغط الدم الأساسي

Authors: Shatha Rouf Moustafa --- Julian Yonan Ismaeil
Journal: Zanco Journal of Medical Sciences مجلة زانكو للعلوم الطبية ISSN: 19955588/19955596 Year: 2018 Volume: 22 Issue: 1 Pages: 32-40
Publisher: Hawler Medical Univeristy جامعة هولير الطبية

Loading...
Loading...
Abstract

Background and Objective: Oxidative stress and inflammation are cooperative events involved in essential hypertension development. This study aimed to evaluate the association of N-terminal pro-Brain natriuretic peptide, matrix-metalloprotinase-9 and 8-oxo2-deoxyguanosine with the essential hypertension, detect the effect of other confounding factors like the stage of the disease and gender, and estimate the correlation between the selected parameters.Methods: This case-control study was performed at College of Pharmacy, Hawler Medical University on 50 hypertensive patients of both genders with essential hypertension as well as 45 matched age–gender adults were also enrolled in this study as a control group. The selected parameters were analyzed using ELISA technique.Results: There was a significant elevation in the serum levels of N-terminal pro-Brain natriuretic peptide, matrix-metalloprotinase-9 and 8-oxo2-deoxyguanosine in patients with essential hypertension as compared with the controls. The mean serum levels N-terminal pro-Brain natriuretic peptide, matrix-metalloprotinase-9 and 8-oxo2-deoxyguanosine were increased significantly according to the stage progression of the disease P ˂0.001. No gender effects could be found.Conclusion: Data suggested an association between circulating biomarkers (NT-proBNP, MMP -9, 8-oxo-2-dG) with the development of essential hypertension, there was a significant elevations in the serum selected parameters level in patients as compared with the control group.

Keywords

EHT --- NT-proBNP --- MMP -9 --- 8-oxo-2-dG


Article
Genetic Algorithm Based Small Distributed Generation Units Addition Technique To Reduce Real Power Losses
تقنية إضافة وحدات التوليد الصغيرة باستخدام الخوارزمية الجينية لتقليل قيمة الفقد بالقدرة الحقيقية

Author: Saraa Esmaeel Khaleel السيدة سراء إسماعيل
Journal: AL-Rafidain Engineering Journal (AREJ) مجلة هندسة الرافدين ISSN: 18130526 Year: 2011 Volume: 19 Issue: 4 Pages: 20-29
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

AbstractThe increasing demand on installing small generating units had resulted in focusing on advanced concern of distributed generation (DG) units located at specific points of the electrical distribution grid as a mean of reduction in real power losses. This issue had been dealt with many techniques over the last decades. This research paper is taking Genetic Algorithm technique into consideration as one of the most efficient tools in calculating the optimum value of these DG units added to the grid locations suffering from loading effect based voltage drop at the minimum real power loss. This research is also concerning the impact of increasing number of locations of DG units added to the grid the percentage of reduction in real power loss.

الملخصإن الطلب المتزايد لوحدات التوليد الصغيرة أدى إلى اهتمام متجدد في وحدات التوليد المنتشرة (Units Distributed Generation) على مواقع معينة من الشبكة حيث تعد وسيلة لتقليل الفقد بالقدرة الحقيقية ، وقد تم التعامل مع الموضوع بتقنيات متعددة على مدى العقود المنصرمة. يتناول البحث هذه المسألة باستعمال الخوارزمية الجينية (Genetic Algorithm) وهي إحدى الوسائل المستخدمة لحساب القيمة المثلى لوحدات التوليد المضافة إلى المواقع التي تعاني من هبوط بالفولتية عند التحميل عند أقل فقد بالقدرة الحقيقية ، وكذلك دراسة تأثير زيادة عدد المواقع لإضافة وحدات التوليد على نسبة تقليل الفقد بالقدرة الحقيقية.تم تطبيق الطريقة المقترحة على منظومة IEEE (30 Bus).


Article
STABILITY ENHANCEMENT BASED ON DISTRIBUTED GENERATION UNITS IN AL-NAJAF AL-ASHRAF ELECTRICAL NETWORK
تحسين الاستقرارية باستخدام التوليد الموزع في شبكة النجف الاشرف الكهربائية

Authors: Rashid Hameed Al-Rubayi رشيد حميد الربيعي --- Zaid Tariq Hasan زيد طارق حسن
Journal: KUFA JOURNAL OF ENGINEERING مجلة الكوفة الهندسية ISSN: 25230018 Year: 2016 Volume: 7 Issue: 1 Pages: 15-26
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

The operation and structure of distribution system are changing with the integration of Distributed Generation (DG) units, where these units may have effect on power losses, stability, voltage profile, power quality and other quantities. Therefore the optimum location, size and number of DG units are necessary to avoid the negative impacts on electric power system. In this work, the Particle Swarm Optimization (PSO) technique is used to find the optimal number and locations of DG in order to minimize the active power losses. The thermal limit of transmission lines and transformers was studied to detect the lines or transformers which exceed the limit in order to process it. The voltage stability of distribution network has been investigated, using L index method.

ان عمل وتركيب نظام التوزيع يتغير مع اضافة وحدات التوليد الموزع (DG )، حيث انها تؤثر على خسائر القدرة ، الاستقرارية ، الفولطية ، جودة الطاقة وكميات اخرى، لذلك فان اختيار الموقع الامثل والحجم وعدد وحدات التوليد الموزع (DG ) ضروري لتجنب التأثيرات السلبية على نظام الطاقة الكهربائية. في هذا البحث استخدمت تقنية (PSO ) لإيجاد العدد والموقع الامثلان لوحدات التوليد الموزع (DG ) لتقليل خسائر القدرة الفعالة. بعد ذلك تم دراسة الحد الحراري لخطوط نقل الطاقة الكهربائية والمحولات لتحديد الخطوط والمحولات التي تجاوزت الحد ومعالجتها. كذلك تم دراسة استقرارية الفولطية لشبكة التوزيع باستخدام طريقة ( L INDEX).  


Article
Protection Coordination with Distributed Generation in Electrical System of Iraqi Distribution Grid

Authors: Rashid H. Al-Rubayi --- Ammar Abbas Majeed
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2016 Volume: 34 Issue: 6 Part (A) Engineering Pages: 1161-1181
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The nature characteristic in conventional distribution networks is radial by single source supplying a downstream network. The interest about the environmental impacts and development in technologies have led to increase distributed generation (DG) interconnected in distribution networks. Protective device coordination will be affected by adding DGs to the existing network through participating to the change in direction of power flow and fault current values and direction which cause loss in settings and mis-coordination for protective devices, especially over current relays. The effect of DG on coordination depend upon number, location and size of DG, so in this work, the Particle Swarm Optimization (PSO) technicality utilization to locate optimal location and sizeof DG to obtain minimum active power losses.The Time Current Characteristic (TCC) curves represented which depended on the over current protection relays parameters to find settings and limited any loss in it, in order to reset these relays to obtained the proper operation without intersections in time of operation and satisfy optimal coordination between primary and pack up over current protection relays.In this work two soft wares are used, the first is Matlab R2014a for implementation of the PSO algorithm while the second software is CYMDist program for load flow analysis, short circuit current calculation and protection coordination device analysis. To verify the developed algorithm parts from Iraqi distribution network (Baghdad Al-Rusafa 33KV distribution networks). So, used two DG units with total capacity 50MW distributed in 33kV of South Al-Rusafa distribution network which represented about 9.4% from the total load of this network 533.5MW, the total active power losses reduced from 11.597MW to 6.658MW with losses reduction 6.96MW about 43% from total losses.