research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
الطاقة الإنتاجية، الإنتاج الفعلي، الاستهلاك المنزلي للمياه النقية في مدينة الموصل

Author: سحر عبد الجبار محمود
Journal: Buhuth Mustaqbaliya Scientific Periodical Journal مجلة بحوث مستقبلية ISSN: 90110681 Year: 2011 Volume: 4 Issue: 4 Pages: 131-145/عدد35
Publisher: Al-Hadba University College كلية الحدباء الجامعة

Loading...
Loading...
Abstract

ABSTRACTSample survey conducted by the author shows that Mosul City uses around 243.000 cubic meter of purified water for domestic purposes. This quantity makes about 43% of total productive capacity (and output) of water purification. Stations are serving the city today (Nov. 2010). This means that around 67% of total productive capacity (and output) goes to other uses including commercial and institutional water on the one hand, and water leaks from water distribution system in the city, on the other. The author thinks that the present study, though limited in scope, paves the way for comprehensive study on the total quantity of purified water use (domestic, commercial, etc.) in Mosul city on the one hand, and the quantity of "water leaks'', on the other. The study results in a number of recommendations.

الملخصبلغت كمية المياه النقية التي يستهلكها القطاع العائلي في مدينة الموصل، في خريف 2010، نحو 243.000 متراً مكعباً يومياً. وتشكل هذه الكمية نحو 43% من الطاقة الإنتاجية العملية لوحدات تنقية المياه العاملة في المدينة، البالغة 622.320 متراً مكعباً يومياً. وقد تم التوصل إلى هذه النتيجة اعتماداً على البيانات الإحصائية -التي تم الحصول عليها بطريقة المسح بالعينة- وعلى البيانات الخاصة بعدد سكان المدينة والطاقة الإنتاجية لوحدات التنقية التي تخدم مدينة الموصل حالياً. إن النسبة المشار إليها تعني أن نحو 67% من الطاقة الإنتاجية (والإنتاج الفعلي تقريباً) لوحدات تنقية المياه التي تخدم مدينة الموصل يذهب إلى الاستخدامات الأخرى وخاصة التجارية والمؤسسية منها، ثم الفاقد المائي. وترى الباحثة أن هذه الدراسة المحدودة النطاق تمهد الطريق لدراسة أكثر شمولاً خاصة بالكمية المستخدمة من المياه النقية لكافة الأغراض من جهة، ولكمية الفاقد المائي الفعلي في مدينة الموصل من جهة أخرى، وقد تم اختتام الدراسة بعدد من المقترحات.


Article
Effect of Calcium Hardness on Corrosion Rate of Domestic Water Galvanized Steel Pipes
تأثير تركيز عسرة الكالسيوم على معدل تآكل أنابيب الماء المنزلي المصنوعة من الفولاذ المغلون

Author: Mohammed Hussein J. Al –Atia محمد حسين جعفر العطية
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2015 Volume: 18 Issue: 1 Pages: 45-53
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

Galvanized steel pipes are the main material in the implementation of domestic water distribution networks throughout Iraq. To study the variables affecting their corrosion, mathematical relationship for the calculation of corrosion rate was derived in terms of dissolved oxygen concentration, flow velocity and temperature based on the principles of mass transfer and electrochemistry , to add the effect of the calcium hardness to this relationship, experiments were conducted for measuring the corrosion rate in a straight 18.5 mm ID pipe flow of water at velocities ranged between 0.18 and 1.21 m/sec for three types of water (hard , moderate and soft). The results Shows the importance of calcium hardness on inhibiting corrosion process for more than five times in hard water compared to that in soft water also an exponential relationship between calculated to experimentally corrosion rate and calcium hardness concentration was obtained. Introducing this relationship as a correction factor for derived relationship sounded the accuracy of calculated corrosion rate results up to more than 90%.This relationship could expect and explain the disparity in the service life of these networks.

أنابيب الفولاذ المغلون المادة الأساسية في تنفيذ شبكات توزيع الماء المنزلي في عموم العراق ولدراسة المتغيرات المؤثرة في تآكلها ، اشتقت علاقة رياضية لاحتساب تغير معدل تآكل هذه الأنابيب بدلالة تركيز الأوكسجين المذاب وسرعة الجريان ودرجة الحرارة بالاعتماد على أسس ومبادئ انتقال الكتلة والكيمياء الكهربائية ، ولغرض إضافة تأثير عسرة الكالسيوم إلى دلالة التغيّر لهذه العلاقة ، أجريت تجربة قياس معدل التآكل بأسلوب الجريان المستقيم داخل نماذج من أنبوب مغلون بقطر داخلي 18.5 ملم عند سرع جريان تراوحت بين 0.18 و 1.12 م ثا ولثلاث أنواع من الماء (عسر ومعتدل العسرة ويسر) ، بينت نتائج هذه التجربة أهمية عسرة الكالسيوم تبعا" لتركيزها في تثبط عملية التآكل لأكثر من خمسة أضعاف في الماء العسر مقارنة" لما عليها في الماء اليسر والحصول على علاقة أسية للنسبة بين معدل التآكل المحسوب نظريا" إلى المستحصل عمليا" بدلالة تغير مقدار العسرة حيث ۥأدخلت هذه العلاقة كعامل تصحيح للدالة الرياضية المشتقة مما جعل دقت نتائج الاحتساب خلالها تصل إلى أكثر من 90%، لتسهل هذه العلاقة تفسير التفاوت في عمر الخدمة وتوقعه.الكلمات المفتاحية : التآكل، تآكل أنبوب الفولاذ المغلون، سرعة الجريان، معامل انتقال الكتلة، عسرة الكالسيوم، الماء المنزلي.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic (2)


Year
From To Submit

2015 (1)

2011 (1)