research centers


Search results: Found 85

Listing 1 - 10 of 85 << page
of 9
>>
Sort by

Article
A Technique of Computer-Simulated Dose Reduction for Conventional Chest Computed Tomography (CT)
تقنية الكومبيوتر لتقليل الجرعة الاشعاعية لمنطقة الصدر بواسطة جهاز المفراس

Author: Runak Tahr Ali د. روناك طاهرعلي
Journal: IRAQI JOURNALOF COMMUNITY MEDICINE المجلة العراقية لطب المجتمع ISSN: 16845382 Year: 2009 Volume: 22 Issue: 2 Pages: 105-111
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Abstract: Computed Tomography is a diagnostic imaging modality giving higher patient dose in comparison with other radiological procedures. The level of CT radiation dose is of concern to radiologists, medical physicists, government regulators, and the media. This review addresses this problem with particular reference to radiation dose in chest CT. Specifically it outlines the topics of measurement units used to quantify radiation exposure, factors affecting CT scanner dose efficiency, scanner settings that determine the administered radiation dose, and radiation dose reduction in chest CT.The Objective: Aim of this study is to determine minimal tube current (mAs) required for good image quality on conventional chest CT (Computed Tomography).Patients & Methods: Prospectively, 35 consecutive patients (mean weight, 65 kg; range, 38-92 kg) older than 45 undergoing conventional chest CT with standard technique (120 kVp, 400 mAs) had four additional sections imaged at reduced tube current (200, 140, 80, 20 mAs) at two levels (tracheal carina and left atrium). CT scans were evaluated in random order by two independent observers who were blinded to technical factors used. Results: The 400 mAs scan was considered the reference standard. When compared with the reference technique (400 mAs), the first and second (200 mAs and 140 mAs) reduction levels showed no significant difference (p > .05) in subjective image quality. A significant difference (p < .001) was seen at the third and fourth (80 mAs and 20 mAs) reduction levels. A two fold reduction in tube current (400-140 mAs) and resultant radiation dose did not cause a significant change in subjective image quality or in detection of lung abnormalities with conventional chest CT. One hundred forty milliampere-seconds is the minimal tube current required to provide good image quality in patients of average weight.CT is a diagnostic imaging modality giving higher patient dose in comparison with other radiological procedures. CT scan parameters have been adjusted with the aim of working towards optimization of image quality and patient dose. Conclusions: The effective dose of our population is (1.8 mSv) compared with UK, Crawly et al and Hughes et al have the same value.Key words: Radiation dose, CT scan& Reduction dose.

الملخص: جهاز المفراس هو لتشخيص الصوروتوضيحها من خلال جرعة اشعاعية مؤثرة,اذا قارناها مع اجهزة اخرى لتشخيص هذه العملية. ان مستوى الجرعة الاشعاعية يتعلق ب الاشعاعين والفيزياء الطبيةوالوسط. وفائدة استخدام الفحص الطبقى المبرمج هى من خلال استخدامها لتشخيص الامراض كما انها دليل برامج التدخل والعلاجية , هذه الفوائد لا تخلوا من المخاطر ولهذا فان توضيح هذه المخاطر وتقليلها ذو أهمية بالغة من خلال التحكم والابقاء على الجرع الاشعاعية فى مثل هذه الانواع من الفحوصات على أقل المستويات المقبولة وخصوصا بالنسبة للاطفال والبالغين من الشباب والذين هم أحيانا يستلمون جرع اشعاعية أكثر من اللازم للحصول على صور تشخيصية ذات معلومات واضحة . الهدف من هذه الدراسة هو ايجاد اقل زمن تيار للتعرض (mAs) مع وضوح الصورة بواسطة جهاز المفراس. وقد اختيرو 35 مريضا وكان معدل الوزني 65 كيلوغرام وبمدى ( 38-92) كيلوغرام وكان عمرهم اكبر من 45 سنة من خلال فحصهم بجهاز المفراس لمنطقة الصدر, وبتقنية معيارية ثابتة لزمن التعرض 400 mAs)) وبتقليل زمن التيار)20,80,140.200( mAs . زمن التيار للتعرض 400 mAs هو كمرجع معيارى ثابت , عند مقارنة زمن التيار مع الاول والثاني )140-200( mAs نرى ان هنالك معيارا غير معنويا P>0.05) ( لخلال الدقة للصورة. ولكن نرى معيارا معنويا P<0.001) ( لزمن تيار للتعرض الثالث والرابع )20-80) mAs وتقليل جرع الاشعاعية .اذا زمن تيار للتعرض 140 -400 mAs لا نرى غموضا للصورة التشخيصية او عدم وضوح منقة المطلوبة بواسطة جهاز المفراس للاوزان المختلفة. أما معدل الجرعة المؤثرة للمرضى هو )1.8 mSv ( مقارنة مع UK. , Crawly et. al, Hugusted et.al


Article
Characterization of silences acid dosimeter for gamma-radiation dosimetry
خصائص حامض السيلنك لقياس الجرعه الاشعاعية لاشعة كاما

Authors: Riyadh. CH.Abul –Hail رياض جاسب ابو الهيل --- H.F Hussein حسين فالح حسين --- H.Bakr حمزة بكر سلمان
Journal: JOURNAL OF THI-QAR SCIENCE مجلة علوم ذي قار ISSN: 19918690 Year: 2013 Volume: 4 Issue: 4 Pages: 125-127
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

Silences acid has been investigated as a dosimeter for high doses of Gamma radiation through measuring the induced changes in optical absorbance from (315-900) nm at room temperature. It was found that the absorbance increased with increasing absorbed Gamma-dose. Also, the dose rate and post irradiation fading of optical absorption spectra has been studied. The results of this preliminary study show that Silences acid may be applied as a simple optical absorbance detector for dose measurement in the dose range (5 - 28 ) kGy.

درست استجابة الامتصاص الضوئي للأطوال الموجية (315-900) نانومتر لحامض السيلنك للجرع العالية لأشعة كاما . وجد ان الامتصاصية تزداد بزيادة الجرعة لأشعة كاما .وكذلك درست معدل الجرعة واستقراريها لطيف الامتصاص .اشيرت النتائج الى امكانية استخدام النموذج ككاشف للجرع العالية من اشعة كاما ضمن المدى (5-28)كيلو كري.


Article
Dose-dependent Anti-inflammatory Effect of Silymarin in Experimental Animal Model of Acute Inflammation

Loading...
Loading...
Abstract

Silymarin, a flavolignans from seeds of ‘milk thistle’ “Silybum marianum” has been widely used from ancient times because of its excellent hepatoprotective action. It has been used clinically to treat liver disorders including acute and chronic viral hepatitis, toxin/drug-induced hepatitis and cirrhosis and alcoholic liver disease. The efficacy and dose-response effect of silymarin (125, 250 and 500 mg/kg) were assessed using egg albumin-induced paw edema in rats as a model of acute inflammation. In this model, 56 rats were used and allocated into 7 subgroups each containing 8 rats. All treatments were given intraperitonealy 30 minutes before induction of inflammation by egg albumin and then the increase in paw edema was measured 1h, 2h and 3h after induction of inflammation by using the vernier caliper. The results indicated that silymarin, at doses range used, significantly lowered paw edema (P<0.05) an effect comparable to that produced by the reference drugs, acetyl salicylic acid, meloxicam and dexamethazone. Paw edema suppressive effect of silymarin 250 and 500 mg/kg was comparable and both of them were significantly different from that of silymarin 125 mg/kg (P<0.05). Therefore, silymarin exert an important anti-inflammatory activity in animal model of acute inflammation, which was significantly increased as the dose increased up to 250 mg/kg.

لقد استخدم الأنسان ومنذ القدم مادة السليمارين المستخلصة من بذور نبات الكعوب بسبب تأثيرها في حماية الكبد. ولقد استخدمت سريريا في الوقت الحاضر لمعالجة أمراض الكبد الحادة والمزمنة والناشئة عن الفيروسات أو التعرض للسموم والكحول. تم في هذه الدراسة تقييم التأثير المضاد للألتهاب لجرع مختلفة من مادة السليمارين (١٢٥، ٢٥٠، ٥٠٠ ملغم/كغم) في نموذج الألتهاب الحاد المستحدث بواسطة الألبومين في قدم الجرذان. تم استخدام ٥٦ جرذا أبيض قسمت الى ٧مجموعات كل مجموعة ضمت ٨جرذان. تم علاج الجرذان بجرع مختلفة من السليمارين عن طريق الزرق بالبريتون قبل ۳٠ دقيقة من استحداث الألتهاب بزرق زلال البيض في قدم الجرذان، وتم قياس مستوى تكوين الوذمة بعد ساعة واحدة، ساعتين وثلاث ساعات بعد استحداث الوذمة باستخدام الفيرنية. أظهرت النتائج بأن للسليمارين فعالية مضادة للألتهاب تعتمد على الجرعة مقارنة بالمركبات القياسية المستخدمة للمقارنة (حامض أسيتيل ساليسيليك، ديكساميثازون والميلوكسيكام). ومن خلال النتائج التي تم التوصل أليها يمكن الأستنتاج بأن للسليمارين تأثير مضاد للألتهاب في النماذج المختبرية للألتهابات الحادة والذي يزداد بزيادة الجرعة حتى ٢٥٠ ملغم/كغم


Article
دراسة تأثير نمط تشغيل ليزر النيديميوم-ياك على قتل خلايا بكتيرية مرضية في محلول ملحي فسيولوجي

Author: مهند عادل
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2008 Volume: 11 Issue: 1 Pages: 29-32
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

Samples of physiologyical solution which contain Escherichia.coli bacteria in a one size 0.5cm3 were prepared, then samples has been radiated by Nd-YAG laser with two mode working in different periods, same dose and wavelength to compare between high power and low power laser for percent of killing, the results revealed occurrence of higher percent of killing by pulsing mode than continuous mode due to destroyed cell when it is absorb a high energy in short time that won't expand the cell by heat that it is happen in long time and a low energy.

حضرت العينات لغرض التشعيع من المحلول الفسيولوجي الحاوي على بكتريا Escherichia.coli في حجم 0.5 سم3 تم أجراء تشعيع العينات لفترات مختلفة لكن بنفس الجرعة الإشعاعية والطول الموجي لغرض المقارنة بين القدرات العالية والقدرات الواطئة على نسبة القتل البكتيري وقد تم الحصول على نسبة قتل أعلى بليزر النيديميوم-ياك ذوالنمط تشغيله النبضي (القدرة العالية) على ليزر النيديميوم-ياك ذو النمط تشغيله المستمر (القدرة الواطئة) وسبب ذلك هو امتصاص الخلية طاقة عالية بزمن قصير يؤدي الى تحطمها دون تمددها تدريجيا الذي يحصل عند الطاقات الواطئة وبزمن طويل .

Keywords

phsiological solution --- dose --- laser --- bacteria.


Article
Radon concentrations in dwellings of Baghdad city- Iraq
تراكيز الرادون في المنازل في مدينة بغداد- العراق

Loading...
Loading...
Abstract

In this study, radon concentrations were measured in dwellings at specified locations in Baghdad city using ionization chamber radon monitor (ALPHA GUARD PQ2000 PRO). The measurements were carried out at different locations of these dwellings (living rooms, bed rooms, bath rooms, and kitchens). The results of the survey showed that the overall minimum, maximum average and mean average radon concentrations in dwellings were 5.77±0.73 Bq/m3, 23.27±13.57 Bq/m3, and 10.67±4.14 Bq/m3 respectively. The lowest average radon was found in (Ameryia) city, while the highest average radon concentration was found in (Kadmiya) city. Also, the results showed that the highest average radon concentration was found in the kitchens, while the lowest average radon concentration was found in the living rooms. The maximum annual effective dose in dwelling in Baghdad city in current study is 0.59 mSv.

تم في هذه الدراسة قياس تراكيز غاز الرادون في المنازل لمناطق منتخبة من مدينة بغداد باستعمال جهاز (ALPHA GUARD PQ2000 PRO). اجريت القياسات في اماكن مختلفة داخل المنازل (غرف الجلوس، غرف النوم، الحمامات، المطابخ). بينت نتائج القياسات ان اقل معدل تركيز للرادون كان(5.77±0.7) بكريل/م3 في منازل العامرية، واعلى معدل تركيز كان (23.27±13.57) بكريل/م3 في منازل الكاظمية بينما كان متوسط معدل تركيز الرادون في المنازل عموما لمدينة بغداد (10.67±4.14) بكريل/م3. كذلك بينت النتائج ان اعلى معدل تركيز للرادون كان في المطابخ بينما كان اقل معدل تركيز في غرف الجلوس. كما بينت الدراسة ان الجرعة المؤثرة السنوية القصوى في المنازل في مدينة بغداد نتيجة استنشاق الرادون هي 0.59 ملي سيفرت.

Keywords

Radon --- Baghdad --- dwellings --- effective dose.


Article
A Mathematical Model to Determination of Alum Amount Added for the Purpose of Coagulation in Water Purification Plants

Authors: Hassan A. Omran --- Mizher A. Kadhim
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2018 Volume: 36 Issue: 4 Part (A) Engineering Pages: 456-460
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Chemicals are used to increase the settling velocity for suspended deposition colloids which are not settled in sedimentation tanks in water purification plants . For this purpose, the alum is used in wide spread across the water purification projects in Iraq. This research contains studying the factors that effect on alum amount added by conducting laboratory tests of water samples from Euphrates river at the purification plant in AL-Musayyab city over ten years (with monthly rate). It was noted that the amount added depends heavily on the turbidity of water entering the purification plant, in addition to water temperature and its pH. The results of laboratory tests have been approved, which included the measurement of the turbidity, pH, temperature, and the value of alum added. Since this method is applicable in all water purification plants. The results during the period of ten years are accredited, and subjected to multi -regression analysis. A mathematical model was conducted to calculate the alum dose, which must be added depending on the raw water turbidity, temperature, and pH. This model also has been examined by using data of another years and gave satisfactory results to be up to 91% each. This model compensates the use of the Jar-test of raw water to determine the amount of alum that must be added and sufficient by measuring the turbidity, temperature, and pH of the raw water only, and then calculating the value of the required dose of alum.

Keywords

Alum Dose --- Coagulation --- Turbidity --- pH


Article
The radiological effects of dust storms in Baghdad- Ramadi area

Authors: K. K. Ali --- S. J. D Shejiri
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2019 Volume: 60 Issue: 2 Pages: 255-262
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Twelve storm dust samples were collected from three cities in Iraq. The samples were collected in the same time during big storms which hit Iraq in summer, 2012 and 2013. The deposited dust on 4 by 4 nylon sheet on surfaces of selected buildings in cities of Baghdad, Fallujah and Al-Ramadi were collected. Each sample was put in sealed Marinilli beaker and kept for 4 weeks to reach the equilibrium state between radium and its short half-life daughters. Gamma spectrometry system based on HPGe was used for analysis of natural and artificial radionuclides in the dust. The activities of natural radionuclides were found to be ranged between 13-19 Bq/kg, 9-14 Bq/kg and 200-240 Bq/kg for Ra-226, Th-232 and K-40 respectively, while Cs-137 was found in all the samples to be ranged between 3-10 Bq/kg. The current study includes the estimation of doses caused by external and internal exposure and inhalation dose of these radionuclides and discusses the potential sources of these relatively elevated concentrations of radionuclides

Keywords

dust --- storms --- radionuclides --- dose --- Iraq.


Article
Radon Concentrations Assessment and Effective Dose Estimation in The Buildings of University of Technology/ Baghdad
تقييم تراكيز الرادون والجرعة الفعالة في مباني الجامعة التكنولوجية- بغداد

Authors: Sahar A. Amin --- Saadi M. D. Al-Nuzal --- Muwafaq H. M. Lami and --- Shemaa K. Kataa
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 13 Part (A) Engineering Pages: 3216-3227
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The objective of the present work was to assess the distribution of radon in the University of Technology buildings, Baghdad - Iraq and to identify the effective dose of radon exposure to the staff using passive dosimeter (SSNTD) CR-39. One hundred CR-39 dosimeters were distributed over different buildings in the University campus according to the number of floors area. The exposure time started from December 2012, and the dosimeters were left inside buildings for 40 days. Only 93 dosimeters were collected, while the remaining 7 were considered lost. The average concentrations were calculated in units of Bqm-3, for each sample in each building, and then are repeated after grouping in each floor of the same building. The average radon concentrations per building and at the university as a whole were also calculated. Radon concentrations were found to vary from 80.1 to 416.7 Bqm-3. The highest radon concentration with a mean value of 416.7 Bqm-3 was found atuniversity press section building, while the lowest radon concentration was found at the welding division 2 building with a mean value of 80.1 Bqm-3. The average value of radon concentration at the university was found to have the value of 181.9 Bqm-3 which is less than the recommended value of 200 Bqm-3 UNSCEAR [18].Dose rate (in µSv/h), annual dose rate (in mSv/y & WLM/y), cumulative dose (in mSv& WLM) and cancer risk were also calculated. It was found that the university staffs are exposed annually to 2.083 mSv which equal to 0.231 Working Level Month (WLM) from radon gas and its short-lived daughters. Hence, a person takes on the average an annual effective dose equivalent to 2.56and 1.84mSv according to average value considered by UNSCEAR [18] and ICRP [19], respectively. This implies an expected value for lung cancer probability of 0.0046.

هدف البحث الى تقييم تركيز الرادون في مباني الجامعة التكنلوجية, بغداد – العراق وكذلك حساب الجرعة الفعالة التي يتعرض لها العاملون في الجامعة باستخدام مجراع كاشف الاثر النووي CR-39. تم توزيع 100 مجراع في مباني الجامعة وتُركتلمدة 90 يوم ابتداءاً من كانون الاول 2012. بينت النتائج ان تركيز غاز الرادون يتراوح بين اوطأ قيمة له80.13 بيكريل/م3 في مبنى شعبة اللحام الى اعلى قيمة له416.67 بيكريل/م3 في مبنى مطبعة الجامعة. كما وجد ان متوسطمستوى الرادون في الجامعة 181.86 بيكريل/م3 وهذه القيمة اقل من القيمة المسموح بها عالمياَ.كما تم في هذه الدراسة حساب معدل الجرعة ومعدل الجرعة السنوية والجرعة المتراكمة وكذلك نسبة خطر الاصابة بسرطان الرئة. وُجد ان العالمين في الجامعة يتعرضون سنوياً الى 2.083mSv من غاز الرادون ووليداتها وهي اقل من المعدلات المسموحة والمقترحة منUNSCEAR (1982) و . ICRP (1993)


Article
The Safety Profile of Single Daily Dose of Aminoglycosides in Comparison with Multiple Daily Dose

Loading...
Loading...
Abstract

To overcome the problems which associated with the standard multiple daily doses (MDD)of aminoglycosides (AGs) like high incidence of toxicity(nephrotoxicity, ototoxicity)(5-25%) and high cost, an alternative approach was developed which was single daily dose (SDD).This new regimen was designed to maximize bacterial killing by optimizing the peak concentration/minimum inhibitory concentration(MIC)ratio and to reduce the potential for toxicity. The study includes 75 patients selected randomly, 50 of them received SDD regimen of age range of 17-79 years and the remaining received MDD regimen of age range of 13-71 years. The study was designed to evaluate the safety of SDD regimen in comparison with MDD regimen. All the patients in SDD group received a constant dose of 5-mg/kg/day of gentamicin and 20mg/kg/day of amikacin with a drug administration interval based on estimated creatinine clearance(CLcr): if ،ف60 ml//min every 24 hours (q24h), 59- 40 ml/ min every 36hours and 39- 30 ml/min every 48 hours.The calculated dose was diluted with 0.9% normal saline or 5% dextrose to 50-100 ml and given as intravenous infusion over 30-60 minutes. In SDD group , the mean length of therapy was 6.4،ہ1.73 days .Gentamicin accounted for 96% of the aminoglycoside use, and the majority(58%) of patients received the drug every 24 hours.The 36- and -48 hours intervals were used for 34 and 8% of the population, respectively.While in MDD group , the mean length of therapy was 5.0،ہ0.91 days. Gentamicin accounted for all (100%) of aminoglycoside use, and all of the patients received the drug every 8 hours. No clinically apparent ototoxicity and nephrotoxicity were observed in the patients in the SDD group, in contrast to the patients in MDD group, in whom 4 patients (16%) were developed nephrotoxicity and 1 patient (4%) was developed ototoxicity. The obtained results indicate that SDD regimen was safer through decreasing the incidence of both nephrotoxicity and ototoxicity.For statistical analysis, ANOVA test was used with P<0.01.Each mean was expressed as mean،ہSEM(Standard Error of Mean).

من اجل تجاوز المشاكل المصاحبة للجرع القياسية المتعددة من دواء الامثبوكلاكوسايد بسبب السمية العالية كتلف الكلى والاذن (5- 25%) والكلف العالية . استحدثت دراسة بديلة في استخدام نظام الجرعة اليومية الواحدة هذا النظام الجديد صمم لزيادة القابلية القاتلة للبكتريا عن طريق زيادة نسبة قيمة التركيز / اقل تركيز مثبط والاقلال من الاعراض الجانبية . تشمل الدراسة على 75 مريض ثم اختيارهم عشوائياً ضمنهم 50 مريض كانوا باعمار (17 – 79 ) سنة استلموا الدواء بنظام الجرعة الواحدة , العدد المتبقي كان بمعدل الاعمار (13 – 71 ) سنة استلموا الدواء بنظام متعدد الجرع . صممت الدراسة لتقييم سلامة نظام الجرعة الواحدة بالمقارنة بنظام متعدد الجرع جميع المرضى في نظام الجرعة الواحدة استلموا جرعة ثابتة 5 ملغم /كغم /يوم من مادة جنتمايسين و 20 ملغم /كغم /يوم من مادة امي كيسين مع فاصل اخذ العلاج اعتماداً على وضوح الكرياتينين المخمن اذا كان اقل من 60 مل / دقيقة يعطى الدواء كل 24 ساعة , 59 – 40 مل / دقيقة كل 36 ساعة و 39 -30 مل / دقيقة كل 48 ساعة . الجرعة المسموحة خففت بمحلول الملح الطبيعي 0.9 % او محلول الدكستروز 5% الى 50 – 100 مل واعطي عن طريق النضوح الوريدي خلال 30 – 60 دقيقة في نظام الجرعة الواحدة كان معدل طول فترة العلاج 6.4 ± 1.73 ايام تم اعطاء الجنتامايسين الى 96% من المرضى والغالبية منهم (58%) استلمو الدواء كل 24 ساعة فواصل الـ 36 و48 ساعة استخدم لـ (34%) ( 8%) من المرضى بالتوالي . بينما في نظام متعدد الجرع كان معدل طول فترة العلاج 5 ± 91 ,0 ايام جميع المرضى (100%) استلموا جنتامايسين كل 8 ساعات . لايوجد ظهور سريري في تسمم الاذن والكلى عند المرضى المستخدمين لنظام الجرعة اليومية الواحدة . بينما في نظام متعدد الجرع حيث ظهرت 4 حالات تلف (16 %) كلى وحالة تلف تسمم الاذن (4 %) .النتائج تؤكد بان نظام الجرعة الواحدة كان اكثر اماناً من خلال تقليل الحالات الجديدة من التلف في الاذن والكلى .


Article
Assessing the effects of low dose aspirin on uricacid and renal function in healthy adults

Authors: Yaser Adeep ياسر اديب --- Jonaya Sarsam جنية سرسم
Journal: Annals of the College of Medicine Mosul مجلة طب الموصل ISSN: 00271446 23096217 Year: 2009 Volume: 35 Issue: 2 Pages: 154-159
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

ABSTRACT
Objective: To evaluate the effects of low daily aspirin doses on uric acid (UA) level and renal functions in healthy adults.
Methods: Healthy adults were randomized to receive 100 mg (n= 33), or 300 mg (n = 31) aspirin daily for one month. Laboratory tests included measurement of blood urea nitrogen (BUN), serum creatinine, and uric acid (UA) levels. Urine creatinine, urea and uric acid excretion were measured in a 24 h collection of urine, 24 hours urine uric acid, creatinine clearance (Ccr), were measured at baseline and then after 4 weeks of therapy.
Results: After 4 weeks of therapy, 100 and 300 mg/d dosage, aspirin caused a 7% and 12% decrease in the rate of UA excretion respectively (P< 0.05). Patients at the dosage 300 mg/d but not the 100mg/day had an increase in serum levels of uric acid (UA), creatinine and urea with a significant decrease in 24 hour creatinine clearance and urinary urea excretion (P<0.05) when compared with the baseline.
Conclusion: Because of the effects of 300 mg dose aspirin, in the lowering of kidney function and the potential of aspirin to cause dose-dependent impairment of renal function, patients taking low-dose aspirin therapy should be monitored for the development of impaired renal function.
Keywords: Low dose aspirin, renal function, healthy adult.

الهــدف: تَقييم تأثيرات جرعات الأسبيرينِ المتدنية اليوميِة على مستوى الحامض البولي ووظائف الكلى في البالغين الاصحّاء. الطريقة: أعطي الأسبيرين عشوائيا (ثلاث وثلاثون شخصا أعطوا 100 ملغم، واحد وثلاثون شخصا أعطوا 300 ملغم) الى البالغين الأصحاء يوميا لمدة 4 أسابيع. شمل الفحص المختبري كمية الحامض البولي، يوريا نتروجين، كرياتينين في مصل الدم، طرح الكرياتينين، الحامض البولي واليوريا نتروجين في الـ 24 ساعة بولِ قبل وبعد 4 أسابيعِ من إعطاء الاسبيرين.النتائـج: ان جرعة الـ 100 ملغم و الـ 300 ملغم أسبيرين يوميا تسبّبت بـ 7% و12% نقصان في نسبة طرح الحامض البولي على التوالي بعد 4 أسابيع. على أية حال، مرضى العينة 300 ملغم وليس 100 ملغم كَان عندهم زيادة في مستويات الحامضِ البولي، الكرياتنين واليوريا في مصل الدم مع نقص معنوي في طرح الكرياتنينِ واليوريا مقَارنة مع ما قبل العلاج.الاستنتاج: بسبب تأثير جرعة الـ 300 ملغم اسبيرين يوميا في ضعف الوظيفة الكلوية وإمكانية الأسبيرين في تسبّب ضعف وظيفة الكلية المعتمد على الجرعةَ. المرضى اللذين يأْخذون جرع منخفضة من علاج أسبيرين يجِب متابعة حالتهم لأي تطور يضعف الوظيفة الكلوية.

Listing 1 - 10 of 85 << page
of 9
>>
Sort by
Narrow your search

Resource type

article (85)


Language

English (59)

Arabic (15)

Arabic and English (7)


Year
From To Submit

2019 (3)

2018 (13)

2017 (17)

2016 (7)

2015 (12)

More...