research centers


Search results: Found 8

Listing 1 - 8 of 8
Sort by

Article
Bearing Capacity of Eccentrically Loaded Strip Footing on Geogrid Reinforced Sand
قابلية التحمل لأساس شريطي محمل لامركزياً على تربة رملية مسلحة

Author: Dr. Jawdat K. Al-Tirkity
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2012 Volume: 19 Issue: 1 Pages: 14-22
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

This study aims to demonstrate the effects of geogrid reinforcement on the bearing capacity of strip footing under eccentric loading. Numerical analysis using finite element program called (PLAXIS 2D Professional v.8.2) are presented. The effect of each of the depth ratio of the topmost layer of geogrid (u/B), the vertical distance ratio between consecutive layers (h/B), number of geogrid layers (N), and the effective depth ratio of reinforcement (d/B) on the bearing capacity were studied, where (B) is the footing width. Also, the combined effect of load eccentricity ratio (e/B), depth of embedment ratio of footing ( /B) and the angle of internal friction ( ) on the ultimate bearing capacity were investigated.

تهدف هذه الدراسة إلى إظهار تأثير التسليح على قابلية التحمل لأساس شريطي تحت تأثير حمل لا مركزي. قدمت نتائج التحليل العددي لبرنامج للعناصر المحددة يدعى (PLAXIS 2D Professional v.8.2 ). تم دراسة تأثير نسبة عمق الدفن لأول طبقة من التسليح (u/B) ونسبة المسافة العمودية بين طبقات التسليح (h/B) وعدد طبقات التسليح (N) ونسبة العمق الفعال لطبقات التسليح (d/B) على قابلية التحمل، حيث (B) هي عرض الأساس، ومن ثم دراسة التأثير المركب لنسبة اللامركزية في الحمل (e/B) ونسبة عمق الدفن للأساس (/B ) وأيضا زاوية الاحتكاك الداخلي ) ( للتربة على قابلية التحمل القصوى.


Article
EXPERIMENTAL STUDY FOR THE INTERACTION CURVES OF CFST COLUMNS SUBJECTED TO A STATIC CENTRIC OR ECCENTRIC LOADS

Author: Alaa Hadi Hameed Hassoon
Journal: Journal of Univesity of Thi-Qar مجلة جامعة ذي قار العلمية ISSN: 66291818 Year: 2016 Volume: 11 Issue: 2 Pages: 1-12
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

An experimental study on composite columns of square and circular steel hollow sections filled with normal concrete has been held in this paper. The concrete used in this study have two different compressive strength with mixing ratios of (1:2:4) and (1:1.5:3); the compressive strength of concrete were (22.9 MPa) and (31.8 MPa) respectively. Square steel hollow sections of (7.5×7.5 cm) and 2 mm thickness used with a yield stress of (352 MPa) while the circular hollow sections have (7.5 cm) diameter and 2 mm thickness with a yield strength of (327 MPa). Samples tested under the effect of concentric and eccentric axial loads with one case in which the column tested horizontally as a beam to evaluate the maximum bending resistance. The interaction curves for both shapes of columns and for two different concrete compressive strength are presented with a simple analysis for the pattern of failure in columns for each case of loading and for each type. The results show that the increase in compression strength of concrete provides more capacity for the composite columns in axial loading more than bending due to the confinement, and the failure in columns with square cross-sections are different from those which have circular cross-sectional area.

تم اجراء دراسة عملية على الاعمدة المركبة ذات المقاطع المربعة والدائرية المجوفة والمملوءة بالخرسانة الاعتيادية. تم استخدام خرسانة الاعتيادية ذات مقاومتي انضغاط مختلفة وبنسب خلط (١:٢:٤) و (١:٥ˏ١:٣) حيث كانت مقاومة الانضغاط للخرسانة هي (٢٢.٩ نت/ مم٢) و (۸.٣١ نت/ مم٢) على التوالي. تم استخدام مقاطع حديد مجوفة مربعة بأبعاد (٧.٥ ×٧.٥ سم) بسمك ٢ ملم ذات اجهاد خضوع ( ۳٥٢ نت/ مم٢) ودائرية الشكل بقطر (٧.٥ سم ) وبسمك ٢ ملم ايضا ذات اجهاد خضوع ( ۳٢٧ نت/ مم٢). تم اختبار النماذج تحت تأثير الحمل المحوري وغير المحوري مع حالة واحدة تم وضع العمود فيها بشكل افقي وفحصه كعتب لغرض ايجاد التحمل الاقصى له في حالة الانحناء. وتم تعيين ال ((interaction curve للأعمدة بنوعيها ولمقاومتين مختلفتين مع تحليل نمط الفشل الحاصل في الاعمدة. اظهرت النتائج بأن الزيادة في مقاومة الانضغاط للخرسانة تزيد من قابلية تحمل الاعمدة تحت تأثير الحمل المحوري بنسبة اكبر من تلك التي تكون تحت تأثير الحمل الغير محوري كما ان الفشل الحاصل في الاعمدة المركبة ذات المقاطع المربعة يختلف نوعا ما عن الفشل الذي يحصل في نظيرتها ذات المقاطع الدائرية


Article
Experimental Study of a Strip Footing under Inclined and Eccentric Load on Geogrid Reinforced Sandy soil

Authors: Mohammed A. Al-Zandi --- Jawdat K. Abbas
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2017 Volume: 24 Issue: 1 Pages: 70-80
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

This study investigates the "bearing capacity" of a strip footing subjected to inclined and "eccentric load" on geogrid reinforced sandy soil by using physical modeling. The effect of each of the "depth ratio" of the first sheet of reinforcement, the vertical space ratio between consecutive sheets, number of reinforcement sheets, and the effective "depth ratio" of reinforcement on the "bearing capacity" were investigated. Also, the combined effect of load inclination angle, eccentricity ratio of the load and the relative density on the ultimate "bearing capacity" were studied. The results illustrated that by increasing the number of reinforcement sheets, the "bearing capacity" increased, but there is an optimum value (4-5). The optimum "depth ratio" of the first sheet of reinforcement was 0.35B. The optimum vertical space ratio between consecutive sheets was 0.25B. Using a test results with helping a statically analysis software program, a new easy and reliable empirical equation for computing the ultimate "bearing capacity" of the strip footing subject to inclined and eccentric load supported on geogrid reinforced sandy soil was developed.


Article
STRUCTURAL BEHAVIOR OF THIN RPC WALL PANELS WITH VARYING STEEL REINFORCEMENT AND ASPECT RATIO SUBJECTED TO AXIAL ECCENTRIC UNIFORMLY DISTRIBUTED LOADING

Authors: Saad Khalaf Mohaisen --- Layth Abdulbari Al-Jaberi --- Aya Haqi Ismael
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2018 Volume: 22 Issue: 4 Pages: 25-38
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

This paper presents experimental study of structural behavior of thin Reactive Powder Concrete (RPC) wall panels subjected to axial eccentric uniformly distributed loading with varying steel reinforcement ratio (ρ) and aspect ratio (AR= H/L). The experimental program included testing of six two-way thin RPC wall panels, fixed at all sides and applying the load axially with eccentricity equal to (t/6). The results indicates that the ultimate strength of the RPC wall panel decreases with increase in AR from (1.25 to 2.00) for panels with H/t = 18.75. The decreasing in ultimate load for RPC wall panels is about 16% and 38.7%, for an increase in AR from 1.25 to 2.0 for panels with ρ = 0.012566, and about 6.38% and 36.2%, for an increase in AR from 1.25 to 2.0 for panels with ρ = 0.007854.The ultimate strength of RPC wall panel increases with an increase of percentage of steel reinforcement ratio (ρ). For an increase in reinforcement ratio from ρ = 0.007854 to ρ = 0.012566 the increase is about (6.4, 4.76 and 2.22) % for walls with AR (1.25, 1.50 and 2.00) respectively. The lateral deflection decrease with the increase of percentage of steel reinforcement ratio from (0.007854 to 0.012566) under two-way in plane loading, When AR= 1.25 the reduction about (1.22 times) and When AR= 2.00 the reduction about (1.11 times). The lateral deflection of RPC wall panels decrease with the increase in aspect ratio.


Article
Strength Evaluation of Hybrid Reinforced Concrete Columns under Eccentric Loads

Authors: Ammar A. Ali --- Zaynab S. Mohammed
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2018 Volume: 36 Issue: 4 Part (A) Engineering Pages: 449-455
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This study presents an experimental investigation of the behavior of hybrid circular columns composed of outer precast reactive powder concrete (RPC) tubes filled with normal concrete (NC). The column specimens were subjected to an eccentric load producing both flexural and axial stresses within the section. The specimens consisting of 200 mm outer diameter with 400 mm height. The column specimens were divided into three groups, each group contains two specimens of thicknesses of outer RPC walls of 50 and 25 mm that filled with NC, in addition to RPC solid column section. The columns of first group were without any reinforcement. While the second group specimens were longitudinally reinforced, in addition to 180 mm spaced ties. The third group is composed of the same details as that of group two but with 90 mm ties spacing. The results show that, All RPC solid specimens give a higher load capacity from that of the hybrid specimens about 48%. It is noticed that increasing the RPC outer wall thickness improves the ultimate load capacity by 11% for hybrid specimens with 50 mm thickness wall than that of hybrid specimens with 25 mm thickness wall. Also, longitudinal and transverse reinforcement noticeably enhance the ductility and strength of the tested specimens compared with corresponding plain specimens.


Article
EXPERIMENTAL STUDY ON STRUCTURAL BEHAVIOR OF THIN WALL CONCRETE PANELS SUBJECTED TO AXIAL ECCENTRIC UNIFORMLY DISTRIBUTED LOADING
دراسة السلوك الإنشائي للألواح الجدارية الخرسانية النحيفة المعرضة الى تحميل محوري لامركزي منتشر

Authors: Aya Haqi Ismael --- Layth A. Al-Jaberi --- Saad Khalaf Mohaisen
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2017 Volume: 21 Issue: 1 Pages: 51-64
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Due to the current popularity of reinforced concrete (RC) wall construction, and the new published of codes of concrete, RC walls have become just as an important structural elements as beam, slabs and columns. This paper presents an experimental study of structural behavior of thin concrete wall panels subjected to axial eccentric uniformly distributed loading with varying aspect ratio (AR=H/L) and concrete type (concrete strength (f 'c)). The experimental program included testing of six two-way thin concrete wall panels, fixed at all sides and applying the load axially with eccentricity equal to wall thickness/6).The results indicate that the load carrying capacity of the normal strength concrete (NSC) wall panels decreased with the increase in AR (H/L) from 1.25 to 2.00, the ultimate load reduced from 37.5% to 14.6 % when AR decreased from 2.00 to 1.25. For Reactive Powder Concrete (RPC), the ultimate load reduced from 38.7% to 16% when AR decreased from 2.00 to 1.25. The strength of the concrete wall increases with the increase in concrete strength (f 'c) from 33.5 MPa to 120.4 MPa , the increase is about (212.5, 207.3, 206.67) % for panels with H/L = (1.25, 1.50, 2.00) respectively. The lateral deflections of concrete wall panels depend on the aspect ratio (H/L) where, the increase in aspect ratio (H/L) from 1.25 to 2.00 of NSC panels causes increasing the lateral deflection of the concrete wall panels, while for Reactive Powder Concrete (RPC) wall panels the increase in aspect ratio (H/L) from 1.25 to 2.00 causes decreasing in the lateral deflection of the concrete wall panels. Also the lateral deflection depends on concrete type (concrete strength (f 'c)), when strength of the concrete wall panel increases from 33.5 to 120.4 MPa, the lateral deflection decreases.

نظرا للانتشار الأخير للبناء بالجدران الخرسانية المسلحة, والمدونات الجديدة الأميركية المنشورة لمعهد الخرسانة الأميركي ACI-Code, أصبحت الجدران الخرسانية عنصر انشائي هام مثل العتبات، والسقوف والأعمدة. هذا البحث يقدم دراسة للسلوك الانشائي للألواح الجدارية الخرسانية النحيفة المعرضة الى تحميل محوري لامركزي موزع بانتظام مع نسب مختلفة من نسبة الارتفاع على العرض(Aspect Ratio) ونوعية الخرسانة ( مقاومة الخرسانة (f 'c)). البرنامج يتضمن فحص ستة نماذج من الألواح الجدارية (two-way action) الخرسانية النحيفة المثبتة بكل الجوانب وتسليط الحمل محوريا مع لا مركزية مساويه الى السمك مقسم على ستة (t/6). النتائج تشير إلى أن مقاومة الجدران الخرسانية (مقاومة الحمل العمودي) ذات المقاومة الاعتيادية تقل مع الزيادة في نسبة الارتفاع على العرض (H/L) من (1.25 الى 2.00), ), الحمل الاقصى انخفض من 37.5٪ إلى 14.6٪ عندما انخفضت نسبة (H/L) من 2.00 الى 1.25. ولجدران خرسانة المساحيق الفعالة (RPC)، الحمل الاقصى انخفض من 38.7٪ إلى 16٪ عندما انخفضت نسبة (H/L) من 2.00 الى 1.25. المقاومة للجدران الخرسانية تزداد مع الزيادة في مقاومة الخرسانة للانضغاط (f 'c) من 33.5 (MPa) إلى 120.4 (MPa). كانت الزيادة (212.5، 207.3، 206.67) ٪ للجدران مع H/L = (1.25 ، 1.50، 2.00) على التوالي. الازاحة الجانبية للألواح الجدارية الخرسانية يعتمد على نسبة الارتفاع على العرض (H/L) حيث أن الزيادة في نسبة الارتفاع على العرض (H/L) من 1.25 الى 2.00 لجدران المقاومة الاعتيادية (NSC) يسبب زيادة الازاحة الجانبية للألواح الجدارية الخرسانية، في حين أن جدران خرسانة المساحيق الفعالة RPC)) الزيادة في نسبة الارتفاع على العرض من 1.25 الى 2.00 يسبب تناقص في الازاحة الجانبية للألواح الجدارية الخرسانية. الازاحة الجانبية يعتمد أيضا على نوع الخرسانة (مقاومة الخرسانة للانضغاط (f 'c))، عندما تزداد مقاومة الخرسانة من (33.5 الى 120.4) (MPa)، يقلل من الازاحة الجانبية.


Article
Behavior of Square Footing Subjected to Gypseous Soil under
تصرف الأساس المربع المستند على تربة جبسية تحت الأحمال المائلة اللامركزية

Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2013 Volume: 20 Issue: 3 Pages: 1-15
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

n this study the behavior of square footing on gypsum soil is studied under inclined and eccentric loads via fabrication of a simulator of square footing (100 mm * 100 mm), fabrication of load tester and putting the soil in a box having a dimensions of (900 mm * 900 mm * 600 mm). A sample of soil is taken from Tikrit University in Salah Al Din province under 3 m depth which has a gypsum content of (50.48 %). The load test is performed on square footing at eccentricity of (e/B= 0, 0.1, 0.2 and 0.3) and an angle of inclination of the impacted load with the column ( i= 0°, 5°, 10°, 15°and 20°). The local specifications of the soil are measured (density, moisture, maximum density and ideal moisture), it is found that that the vertical falling, horizontal displacement, and base inclination increases with the increasing of eccentricity and inclination of impacted load, the soil resistance is less than the theoretical results for previous researchers in vertical load whereas it is approaching the theoretical results in inclined load. It is also observed that soil resistance decreases with the increasing of eccentricity of impacted load at local density and humidity, whereas it approaches the theoretical results at maximum density, ideal moisture and vertical load conditions and gives results higher than that of theoretical analysis in inclined load where it decreases with increasing the eccentricity of impacted load.It is found that a high settlement occur in footing when a water (unsaturated with gypsum salts) diffuses through the soil, then gypsum become soluble thereby the soil resistance decreases because of rupturing of chemical bond between gypsum and soil.

تضمن هذا البحث دراسة تصرف الأساس المربع المستند على تربة جبسيه والمعرض لأحمال مائلة ولامركزية من خلال تصنيع نموذج للأساس المربع بأبعاد (100mm x 100mm) وتصنيع جهاز فحص التحميل و وضع التربة في صندوق بأبعاد (900mm x 900mm x 600mm).أخذت التربة من موقع جامعة تكريت في محافظة صلاح الدين وعلى عمق 3 أمتار من مستوى سطح الأرض وكانت ذات محتوى جبسي عالي (50.48%). اجري فحص التحميل على الأساس عند لامركزية (e/B=0.0, 0.1, 0.2 and 0.3) وزاوية ميل للحمل المسلط مع العمود (i= 00, 50, 100, 150 and 200). أخذت كثافة التربة الحقلية والرطوبة الحقلية وكذلك الكثافة العظمى والرطوبة المثلى والكثافة العظمى والرطوبة الحقلية إذ وجد أن الهبوط العمودي والإزاحة الأفقية وميلان الأساس تزداد مع زيادة لامركزية وميلان الحمل المسلط وان قابلية تحمل التربة كانت اقل من النتائج النظرية لباحثين سابقين عندما كان الحمل عموديا ونتائج مقاربة من النتائج النظرية عندما كان الحمل مائلا في حالة الكثافة الحقلية والرطوبة الحقلية وتقل قيمة قابلية تحمل التربة مع زيادة لامركزية الحمل المسلط بسبب صغر المساحة الفعالة للأساس. أما في حالة الكثافة العظمى والرطوبة المثلى فوجد أن قابلية تحمل التربة كانت مقاربة للنتائج النظرية عندما كان الحمل عموديا ونتائج أعلى من النتائج النظرية عندما كان الحمل مائلاً ثم تقل هذه النتائج مع زيادة اللامركزية للحمل المسلط. وعند استخدام الكثافة العظمى والرطوبة الحقلية كان تأثير اللامركزية وميلان الحمل قليلا و قابلية تحمل التربة كانت عالية جدا وأعلى من النتائج النظرية. وعند غمر التربة الجبسيه بالماء يؤدي إلى حصول هبوط عالٍ في الأساس بسبب تحلل الجبس وتقليل قابلية تحمل التربة كثيرا بسبب تحطم الآصرة الكيميائية بين الجبس والتربة.


Article
Experimental Study of Rectangular Footing under Inclined and Eccentric load on Geogried Reinforced Sand
دراسة تجريبية لأساس مستطيل تحت حمل مائل ولا مركزي على رمل مسلح بالمشبكات الأرضية

Authors: Nasr A. Hasan --- Jawdat K. Abbas
Journal: Muthanna Journal of Engineering and Technology(MJET) مجلة المثنى للهندسة والتكنولوجيا ISSN: 25720317 25720325 Year: 2017 Volume: 5 Issue: 3 Pages: 87-94
Publisher: Al-Muthanna University جامعة المثنى

Loading...
Loading...
Abstract

This study investigates the behavior of a rectangular footing subjected to inclined and eccentric load on geo-grid reinforced sand by using laboratory modeling. Small model was used to simulate the behavior of rectangular surface footings (length to width ratios of the footings were equal to 1, 1.25, and 1.5). The effect of the eccentricity and inclination of applied load on the bearing capacity, settlement, horizontal displacement and tilt were investigated. The load eccentricity varies from (0, 0.05B, 0.1B to 0.15B) and the load inclination varies from (00, 50, 100, 150) . The dry sand is reinforced by multiple layers (1, 2, 3, 4 and 5) of Geo-grid. The results illustrated that by increasing the number of reinforcement layers, the bearing capacity increased, but there is an optimum value (5). In general, for central, inclination and eccentricity loading the results indicated that by increasing the number of reinforcement layers (N) the bearing capacity increased while settlement, horizontal displacement and tilt decreased.

تستكشف هذه الدراسة قابلية التحمل لأساس مستطيل خاضعة لحمل مائل ولا مركزي على رمال مسلح بمشبكات أرضية باستخدام نموذج مختبري. تم استخدام نموذج صغير لمحاكاة سلوك الأسس السطحية المستطيلة (كانت نسب الطول إلى العرض لأسس تساوي 1، 1.25، 1.5). تأثير ألامركزية وميلان الحمل المسلط على قابلية التحمل والهبوط و الإزاحة الأفقية وميلان الأساس تم استكشافها. تم تسليح الرمل بعدة طبقات من المشبكات الأرضية (1،2،3،4،5). اللامركزية في الحمل المسلط تتغير من (0.01B ، 0.1B الى 0.15B) وان ميلان الحمل المسلط يتغير من ( 00، 50، 100 الى 150). أظهرت النتائج بزيادة عدد طبقات التسليح تزداد قابلية التحمل ولكن هنالك قيمة مثلى لعدد طبقات التسليح وهي (5). بصوره عامة ولحمل مركزي أو لا مركزي أو مائل فان زيادة عدد طبقات التسليح يزيد من قابلية التحمل ويقلل من الهبوط و الإزاحة الأفقية وميلان الأساس .

Listing 1 - 8 of 8
Sort by
Narrow your search

Resource type

article (8)


Language

English (8)


Year
From To Submit

2018 (2)

2017 (3)

2016 (1)

2013 (1)

2012 (1)