research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Diagnostics of dusty plasma properties in planar magnetron sputtering device
تشخيص خصائص البلازما المغبره في منظومه الترذيذ المغناطيسية ذات الابعاد المستوية

Authors: Raghad T. Ahmead رغدة طلال احمد --- Qusay A. Abbas قصي عدنان عباس
Journal: Iraqi Journal of Physics المجلة العراقية للفيزياء ISSN: 20704003 Year: 2015 Volume: 13 Issue: 26 Pages: 64-75
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The effect of Al dust particles on glow discharge regions, discharge voltage, discharge current, plasma potential, floating potential, electron density and electron temperature in planar magnetron sputtering device has been studied experimentally. Four cylindrical Langmuir probes were employed to measure plasma parameters at different point on the radial axis of plasma column. The results shows the present of Al dust causes to increase the discharge voltage and reduce the discharge current. There are two electron groups in the present and absent of Al dust particles. The radial profiles of plasma parameters in the present of dust are non- uniform. The floating potential of probe becomes more negatively while the plasma potential becomes positive when the dust immersed into plasma region. The electron density increases in the present of dust particle which lead to decreases the electron temperature.

تم دراسة تجريبية لتأثير غبار الالمنيوم على كل من منطقة التفريغ المتوهج ،وفولتيه التفريغ، تيار التفريغ،جهد البلازما،الجهد العائم و درجة حرارة الالكترون في منظومة الترذيذ المغناطيسي۰فقد تم استخدام اربعة مجسات لانكمور اسطوانية لقياس معلمات البلازما لمختلف نقاط الاشعاعية على طول عمود البلازما ۰ فقد بينت النتائج في وجود غبار الالمنيوم تزداد فولتيه التفريغ وحدوث نقصان التيار التفريغ بالاضافة الى ذلك وجود مجموعتين من الالكترونات ذات طاقات مختلفة بوجود وعدم وجود الغبار الالمنيوم۰ وان التوزيع المحوري لمعلمات البلازما تكون غير منتظمة بوجود غبار الالمنيوم. وان الجهد العائم يصبح اكثر سالبيه بينما يصبح جهد البلازما موجب عند دخول الغبار الى منطقه البلازما وان الكثافة الإلكترونية تزداد بوجود الغبار مما تؤدي الى تقليل في درجة حرارة الالكترون.


Article
The dynamical work of continuous CO2 laser and studying some of plasma parameters produced by laser
ديناميكية تشغيل ليزر ثاني اوكسيد الكاربون المستمر ودراسة بعض معلمات البلازما المنتجة باليزر

Author: Awatif Sabir Jassim عواطف صابر جاسم
Journal: Diyala Journal For Pure Science مجلة ديالى للعلوم الصرفة ISSN: 83732222 25189255 Year: 2013 Volume: 9 Issue: 1 Pages: 24-41
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

In this paper we introduce a modified continuous CO2 laser ( CW CO2 laser ) hence some changes in the principle constitutions were done, such that , the continuous power supply with output voltage of 12 KV and 100 mA . For the purpose of measuring the effect of temperature of laser medium on basic parameter, the system was connected to digital thermometer. The measurement of some basic parameters and its effect on the output power of laser and the selection of optimum condition for operating the system in case of operating by using three gas cylinders (CO2, N2, He) separately and the other by using gas mixture of ( He: 82%, N2: 13.5%, Co2: 4.5% ) , three factors were subjected to change , first, the change of pressure of gas mixture inside the electric discharge tube, second, the effect of changing the electric discharge current, third, the effect of changing the ratio of He gas in the gas mixture were achieved the experimental results shows that the best pressure for gas mixture to produce the laser is ( 30 mbar ) while it was ( 25 mbar ) in using each gas separately by ratios ( 10: 15: 75 )% for ( CO2, N2, He ) respectively with different discharge currents . 12 mA was found to be the best discharge current and 75% was the best ratio for He in gas mixture . The characteristics of plasma-laser CO2 was studies, the theoretical value of the output power laser were determined and compared with measured value

تم في هذه الدراسة تأهيل منظومة ليزر ثاني أوكسيد الكاربون المستمر ( CW Co2 Laser ) حيث تم تغير بعض المكونات الأساسية للمنظومة ، ومن هذه المكونات مجهز القدرة الكهربائي المستمر بفولتية خرج مقدارها (12KV ) وتيار (100 mA) . لغرض قياس درجة الحرارة تم ربط المنظومة بمقياس رقمي (Digital Thermometer) حيث تم من خلاله دراسة تأثير درجة حرارة الوسط الليزري على المعلمات الأساسية. تم خلال هذه الدراسة قياس بعض المعلمات الأساسية وتأثيرها على قدرة الخرج الليزري واختيار الشروط المثلى للتشغيل المنظومة في حالتي تشغيل المنظومة باستخدام ثلاث أسطوانات للغازات (CO2 -N2 -He) على انفراد ، والحالة الثانية استخدام خلطة غازية مجهزة من قبل شركة (PHWY) الألمانية وبنسب (He:82% -N2:13.5% -CO2:4.5%) . وتم دراسة بعض المعلمات وتأثيرها على قدرة خرج ليزر CO2 من خلال دراسة تغيير ضغط الخليط الغازي داخل انبوبة التفريغ الكهربائي ، وكذلك تأثير تغيير تيار التفريغ الكهربائي إضافة إلى تأثير تغيير نسبة غاز He في خليط الغازات على هذه القدرة . أظهرت النتائج العملية ان أفضل ضغط لخليط الغازات الجاهزة لتوليد الليزر هو (30 mbar) بينما كان أفضل ضغط عند استخدام الغازات كلٌ على انفراد هو ( 25 mbar ) بنسب (% (10:15:75)للغازات ( CO2 , N2 , He) على التوالي عند تيار التفريغ مختلفة ، اما أفضل تيار تفريغ فكان ( 12 mA ) ، اما أفضل نسبة لغاز الهليوم في خلطة الغازات كانت ( 75% ) .وكذلك تم دراسة خصائص بلازما ليزر CO2 والتوصل الى القيمة النظرية لقدرة الخرج الليزري ومقارنة هذه القيمة مع القيمة العملية المحسوبة.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic and English (1)

English (1)


Year
From To Submit

2015 (1)

2013 (1)