research centers


Search results: Found 4

Listing 1 - 4 of 4
Sort by

Article
The Estimation of Random Response of a Coupled Cylindrical-Conical Shell System Using Statistical Energy Analysis

Author: Adnan Dawood Mohammed
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2011 Volume: 29 Issue: 2 Pages: 212-225
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

A composite, coupled, thin cylindrical-conical shell system made of polyesterresin reinforced by uniformly distributed, chopped, E-glass is analyzed usingStatistical Energy Analysis. Response displacement estimate of the twosubsystems are obtained due the excitation of the cylinder by a broadband whitenoise of constant spectral density function. The paper is an attempt to study thevalidity of the SEA hypothesis as applied to coupled built-up structures. This iscarried out by the comparison of response estimates of the coupled system indifferent 1/3rd octave frequency bands with those obtained from Finite Elementmethod. The outcome of this work shows that SEA is a powerful tool for thevibration analysis of coupled systems at high frequencies when the number ofinteracting coupled resonant modes is high. Percentage error obtained from thecomparison of results drops sharply as one goes further in frequency. This paperrecommends that the user of SEA must always be aware of the uncertainty of theresults obtained. The uncertainty may arise from the improper selection ofsubsystems, coupling loss factors, and the number of interacting resonant modesof the coupled system.


Article
Energy and Exergy Analysis of the Crude Oil Fractionation Units
تحليلات الطاقة و الاكسيرجي في وحدات تكرير النفط الخام

Authors: Majed Yousif.Khamo --- Adel Sharif. Hamadi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2010 Volume: 28 Issue: 20 Pages: 6010-6019
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The petroleum refining industry is one of the largest users of distillationtechnology. The crude distillation unit is one of the most important refinery operationsfractionating preheated crude oil into respective product fractions like Heavy Naphtha,Kerosene, Aviation Fuel, Light Gas Oil, Heavy Gas Oil, Reduced Crude Oil, etc. Ituses heat supplied at higher temperature levels, and rejects almost equal amount ofheat in the condenser at lower temperature levels yielding a separation work ofmixtures. Therefore, it becomes important to study the energy and exergy of the crudeoil fractionation tower to analysis the energy efficiency.The present study deals with a thermodynamics analysis, energy and exergyefficiencies and the irreversibility rate for of the crude oil fractionation tower (AFT).The results shows that the total irreversibility losses are 90.7 MW, 95% arecontributed by the AFT, and 5% by the furnace, for a flow rate of 159.2 kg/s of crudeoil processed. The energy efficiencies are 0.597 for the AFT, 1.0 for the furnace as weare assuming adiabatic heat transfer in the process and 0.704 for the overall system.The exergy efficiencies are 0.5867 for the AFT, 0.974 for the furnace and 0.638 forthe overall system. From the values of the energy efficiencies, exergy efficiencies, andthe irreversibility rate in spite of the decline of the fractionation unit equipments, itshows that the operating conditions used (especially the temperature profile and thepressure profile of the AFT and the flow rates of the different streams) gives the bestresults.

تعتبرصناعة تكرير النفط الخام من اكثر العمليات استخداما لتكنولوجيا التقطير و التي تعتبر من اكثر الوحداتاهمية في مصافي النفط, حيث يتم فيها تسخين ثم تجزئة النفط الخام الى عدة مقاطع بترولية مهمة مثل النفثاالثقيلة, الكيروسين, وقود الطائرات, زيت الغاز الخفيف, زيت الغاز الثقيل, و متبقي عملية التقطير و غيرها.ان عملية التجزئة هذه تتم باستخدام مستويات عالية من الطاقة الحرارية ولذلك فان دراسة و تحليل الطاقةوالاكسيرجي يعتبر مهما جدا.لدراسة AFT ان الغرض من هذه الدراسة هي اجراء التحليلات الثرموديناميكية لبرج تجزئة النفط الخامكفاءة الطاقة و كفاءة الاكسيرجي, و معدل الخسارة الكلية وذلك لوجود كميات ضائعة من الاكسيرجي في هذهالوحدات و معداتها. لقد استخدم اسلوب تحليل الطاقة و تحديد الاداء و اختيار الامثل من الظروف المطلوبدراستها خاصة درجات الحرارة و الضغوط و معدلات الجريان لمختلف خطوط الجريان في وحدة التكرير.النتائج المستحصلة بينت بان الخسارة الكلية في الاكسيرجي في الوحدة تبلغ ( 90.7 ميكا واط) وذلك لمعدل جريان يبلغ ( 159.2 ) كغم/ثانية من النفط الخام المراد تكريره حيث تمثل هذه الخسارة بمكونات وحدة التكريرحيث ان النسبة الكبيرة من الخسارة تحصل في AFT متمثلة بفرن تسخين النفط الخام و برج التكرير الجويالبرج حيث تحدث بة عمليات الفصل. و عند افتراض الظروف الاديباتيكية لانتقال الحرارة , فان كفاءة الطاقةو 1.00 للفرن. لقد اعطت الظروف التشغيلية المستخدمة في الوحدة نتائج مقبولة AFT كانت 0.597 لوحدةمن الكفاءات و معدل الخسارة بالاكسيرجي.


Article
Building Information Modeling (BIM) as Economical and Properties Assessment Tool for Building Units Alternatives Made with Lightweight Foamed Concrete

Authors: Abbas M. Abd عباس مهدي عبد --- Dunya S. Jarullah
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2018 Volume: 11 Issue: 2 Pages: 33-41
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

Lightweight foamed concrete brick is new construction materials. It gives a prospective solution to building construction industry, this research aims to study the cost, dead loads, environmental issues and energy consumption from using lightweight foam concrete bricks as construction materials by utilizing building information modeling technique. The results obtained from this modelling proved that the cost of brick work using lightweight foamed concrete units of grade A (2000 kg/m3) and B (1800 kg/m3) is higher by (19.4% and 11.9%) respectively than the activity cost using traditional fired clay bricks. For grade C (1600 kg/m3) that cost was very close to fired clay bricks (+2.9%). while the construction of brick work using light weight foamed concrete units of grade D (1400 kg/m3) and E (1200 kg/m3) was lower by (8% and 18.6%) than fired clay bricks. Besides that, the dead load generated by building units was decreased by (7.7-38.5%) for grade (B, C, D, E) than the load of fired clay bricks, while the load generated from used lightweight foam concrete bricks grade is very closed to fired clay bricks (+2.5%). There was a reduction in energy consumption by the rate of (4.1-62.2%) for heating and (9.8-73.4%) for cooling as wall sharing in energy consumption. Environmental analysis showed sustainable potential so that the production of lightweight foamed concrete units reduces CO2 emission by (46.5-67.9%) compared with the fired clay bricks. Finally; it can be concluded that building units produced in this research with LWFC, characterized with properties can efficiently compete the fired clay bricks.


Article
Energy Analysis of Solar Collector With perforated Absorber Plate
تحليل الطاقة لمجمع شمسي ذو صفيحة امتصاص مثقبة

Authors: Hana Abdulhussien Sahi هناء عبد الحسين ساهي --- Ammar Ali Farhan عمار علي فرحان
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2017 Volume: 23 Issue: 9 Pages: 89-102
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The thermal performance of three solar collectors with 3, 6 mm holes and without perforation absorber plate was experimentally assessed. The experimental tests were implemented in Baghdad during January and February 2017. Five values of airflow rates range between 0.01 – 0.1 m3/s were used through the test with a constant airflow rate during the test day. The variation of the following parameters was recorded every 15 minutes air temperature difference, useful energy, absorber plate temperature, and collector efficiency. The experimental data reported that the number of absorber plate perforations with a small diameters is more efficient than increasing the hole diameters of the absorber plate with decreasing the perforation numbers. The maximum air temperature difference throughout the solar collector with 3, 6 mm perforations and without perforations were 17, 15, and 12 oC, respectively. Also, it can be conclude that the energy gained from the solar collector with 3 mm perforation absorber plate is 28.2 % higher than the energy gained from solar collector without holes per day for 0.1 m3/s airflow rate. The maximum values of the thermal performance curves were 67 %, 64 %, and 56 % for the solar collector with 3, 6 mm, and without perforations, respectively.

تم تقييم الأداء الحراري عملياً لثلاثة مجمعات شمسية ذات لوح امتصاص تحتوي على ثقوب 3 و 6 ملم وبدون ثقوب. اجريت الاختبارات التجريبية في بغداد خلال شهري كانون الثاني وشباط لعام 2017. تم استخدام خمسة قيم لمعدلات تدفق الهواء تتراوح بين 0.01 - 0.1 م 3 ثانية خلال التجارب مع معدل تدفق هواء ثابت خلال الاختبار الواحد. تم تسجيل بيانات العناصر الآتية كل 15 دقيقة: الفرق في درجة حرارة الهواء، الطاقة المفيدة، درجة حرارة لوح الامتصاص، وكفاءة المجمع. اثبتت البيانات العملية أن زيادة عدد ثقوب لوح الامتصاص مع قطر صغير هو أحسن كفاءة من قطر كبير وعدد قليل من الثقوب في لوح الامتصاص. أقصى فرق في درجة حرارة الهواء خلال المجمع الشمسي ذو لوح امتصاص يحتوي على ثقوب 3 و 6 ملم وبدون ثقوب كانت 17، 15، و 12 درجة مئوية، على التوالي. أيضا، يمكن استنتاج أن الطاقة المكتسبة من المجمع الشمسي ذو لوح امتصاص يحتوي على ثقوب 3 ملم هي أكثر من الطاقة المكتسبة من المجمع الشمسي ذو لوح امتصاص بدون ثقوب بمقدار 28.2 ٪ في اليوم لمعدل تدفق هواء بمقدار 0.1 م 3 ثانية. كانت القيم القصوى لمنحنيات الأداء الحراري هي %67، %64، و % 56 لمجمع الشمسي ذو لوح امتصاص يحتوي على ثقوب 3 و 6 ملم وبدون ثقوب ، على التوالي.

Listing 1 - 4 of 4
Sort by
Narrow your search

Resource type

article (4)


Language

English (4)


Year
From To Submit

2018 (1)

2017 (1)

2011 (1)

2010 (1)