Performance of Cooling Tower with Honeycomb Packing

Authors: Nagam Obaid Kariem --- Hayder Mohamad Jaffal
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2011 Volume: 29 Issue: 6 Pages: 1080-1093
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The objective of this study is to investigate experimentally and theoreticallyheat and mass transfer characteristics of the cooling tower. The investigationcarried out at a mechanical forced direct cooling tower. A column-packing unit ismade of a new type of packing named honeycomb (plastic). Air and water areused as fluids and the runs are done at the air and water mass flow rates rangingbetween 0.05 and 0.15 kg/s, and between 0.1 and 0.25 kg/s, respectively. The inletwater temperatures ranging between 35 and 50 oC. A mathematical model basedon the equations of mass transfer and energy is used and solved to determine thecharacteristics of cooling tower, pressure drop, temperature ratio, and towereffectiveness. There is reasonable agreement from the comparison between thecalculated and measured data.


Article
Thermo- economic analysis of inlet air cooling in gas turbine plants in Basrah(Al-Rumaila gas turbine power plant case study)
تحليل حراراي - اقتصادي لتبريد الهواء الداخل لمحطات القدرة الغازية في البصرة ( محطة القدرة الغازية في الرميلة كحالة دراسية)

Author: Hussien S. Sultan
Journal: Thi-Qar University Journal for Engineering Sciences مجلة جامعة ذي قار للعلوم الهندسية ISSN: 20759746 Year: 2016 Volume: 7 Issue: 1 Pages: 58-66
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

In the hot regions the demand on electricity increased in the hot months. Gas turbine power plant is a good solution for this problem, since it has low cost, low time of installation and stable with electricity grid variation. But the power output of gas turbine is affected by the ambient temperature, the power decrease by 18% when the ambient temperature increase to 40oc. Inlet air cooling methods are used to boost the power losses in the hot days. In the present study a thermally and economically analysis was performed for Al-Rumaila gas turbine power plant located in Basrah (south of Iraq). The plant consist from five units and each unit designed to generates 296MW.The results shows that, the maximum decrease in the power developed due the increase in ambient air temperature reaches 22.97% during the month of July. The percentage of power saving due inlet air cooling increased with increasing the ambient air temperature.

في المناطق ذات المناخ الحار يزداد الطلب على الطاقة الكهربائية في الاشهر الحارة. تعتبر محطات القدرة الغازية حل جيد لهذه المشكلة, لان كلفة انشائها منخفضة , الوقت اللازم لتشييدها قصير ومستقرة مع التغيرات الحاصلة في الشبكة الكهربائية. لكن القدرةالمنتجة من المحطات الغازية تتأثر كثيرا بدرجة حرارة المحيط الخارجي, حيث تنخفض القدرة بمقدار 18% عندما ترتفع درجة حرارة المحيط الخارجي الى 40 درجة مئوية. تستخدم طرق متعددة لتبريد الهواء الداخل للمحطات الغازية من اجل تعزيز القدرة الخارجة منها. في هذه الدراسة تم تطبيق تحليل حراري اقتصادي لمحطة قدرة غازية في محافظة البصرة جنوب العراق. المحطة تحتوي خمس وحدات والقدرة التصميمية لكل وحدة هي 296 ميكاواط. اثبتت النتائج ان اعظم هبوط للقدرة المنتجة بسسبب ارتفاع درجة حرارة المحيط الخارجي يصل 22.97% خلال شهر تموز. النسبة المئوية للتوفير في القدرة بسسبب تبريد الهواء الداخل تزداد مع ارتفاع درجة حرارة المحيط الخارجي.


Article
Experimental study of a multi-stage evaporative cooler
دراسة عملية لمبردة الهواء التبخيرية متعددة المراحل

Authors: عامر عبدالله محمد --- عقيل علي وناس --- بيداء جابر نبهان
Journal: Thi-Qar University Journal for Engineering Sciences مجلة جامعة ذي قار للعلوم الهندسية ISSN: 20759746 Year: 2016 Volume: 7 Issue: 1 Pages: 1-8
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

In this study, the evaporative cooler is developed by adding multistage of heat exchangers (air – air and water – air) to cool indirectly and indirectly the input air and then cooling directly inside the classical evaporative cooler. The multistage evaporative cooler is assisted to reduce the energy consumption, environmental pollution, global warming phenomenon and manufacturing cost compared than compression refrigeration systems. The multistage evaporative cooler is suitable and done in houses and large buildings with relatively high temperatures and humidity. The experimental results of developed evaporative cooler showed that adding cooling stage to classical cooler reduces the out dry bulb temperature about (50%) and the specific humidity by (70%).

تم في هذه الدراسة تطوير مبردة الهواء التبخيرية وجعلها متعددة المراحل حيث اسُتخدمت المبادلات الحرارية المتنوعة هواء-هواء وماء-هواء لتبريد الهواء بشكل غير مباشر ومن ثم بشكل مباشر عن طريق وسائط التبخير الموجودة في المبردة التبخيرية,وذلك بسبب نقصان موارد الطاقة وتلوث البيئه وظاهرة الاحتباس الحراري حيث اصبحت الحاجة مُلحة للبحث عن موارد بديلة لتقليل استهلاك الطاقة .ان انظمة التبريد التي تعمل على مبدأ الانضغاط تستهلك كمية كبيرة من الطاقة بالاضافة الى ان غازات التبريد تساعد على زيادة التلوث ,من هنا جاءت فكرة تطوير مبردة الهواء التبخيرية وجعلها تعمل في اجواء ذات درجات حرارة ورطوبة عالية نسبياً واعطاء ظروف مريحة في المنازل والمباني الكبيرة , حيث اظهرت النتائج العملية فعالية هذه الطريقة من ناحية التبريد القياسية واستهلاك الطاقة وكلفة التصنيع مقارنةً باجهزة التبريد الانضغاطية.وبينت النتائج ان اضافة مرحلة تبريد الى المبردة التقليدية يؤدي الى انخفاض درجة الحرارة الجافة للهواء((dry bulb temperature الخارج بنسبة ((50% وانخفاض المحتوى الرطوبي(specific humidity) بنسبة (70%).


Article
Two Stage Evaporative Cooling of Residential Building Using Geothermal Energy
لتبريد التبخيري ذو المرحلتين لمبنى سكني باستخدام طاقة باطن الارض

Authors: Ali Hammoodi Mahdi Alhosainy --- Issam Mohammed Ali Aljubury
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2019 Volume: 25 Issue: 4 Pages: 29-44
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The weather of Iraq has longer summer season compared with other countries. The ambient temperature during this season reaches over 50 OC which makes the evaporative cooling system suitable for this climate. In present work, the two-stage evaporative cooling system is studied. The first stage is indirect evaporative cooling (IEC) represented by two heat exchangers with the groundwater flow rate (5 L/min). The second stage is direct evaporative cooling (DEC) which represents three pads with groundwater flow rates of (4.5 L/min). The experimental work was conducted in July, August, September, and October in Baghdad. Results showed that overall evaporative efficiency of the system (two coils with three pads each pad of 3cm) reach to 167 % with the temperature difference between ambient and supply is 26.2oC. While it reached 122.7% (one coil with three pads ) with the temperature difference between ambient and supply is 16OC and reduced to 84.88% and 84.36% for IEC and DEC respectively.

يمتاز فصل الصيف في العراق بانه من اطول فصول السنة مقارنة مع البلدان الاخرى. حيث تصل درجة حرارة المحيط الخارجي الى اكثر من 50 درجة مئوية مما يجعل نظام التبريد التبخيري مناسب لمثل هذه المناخات. يتكون الجزء العملي من نظام التبريد التبخيري من مرحلتين. المرحلة الاولى تتكون من التبريد التبخيري الغير مباشر المتمثل بالمبادلات الحرارية وبمعدل تدفق مياه جوفية 5 لتر/دقيقة. أما المرحلة الثانية فانها تتألف من التبريد التبخيري المباشر المتمثل بحشوات كارتونية ذات سمك 3 سم مع معدل تدفق مياه جوفية (4.5) لتر/دقيقة. اجريت التجارب العملية في بغداد خلال شهر تموزو اب و ايلول وتشرين الاول. أظهرت النتائج ان كفاءة التبريد التبخيري لمرحلتين مبادلان حراريان مع ثلاثة حشوات (سمك كل حشوة 3سم) تصل الى 167% مع فرق درجات حرارة الهواء الخارجي والمجهز تصل الى 26.2 درجة سليزية . بينما تصل الى 122.7% بأستخدام (مبادل حراري واحد مع ثلاثه حشوات) مع فرق درجات حرارة الهواء الخارجي والمجهز تصل الى 16 درجه سليزية وتنخفض الى 84.88% و84.36% للتبريد التبخيري الغير مباشر والمباشر على التوالي.


Article
Enhancement the Performance of Condenser of Split Type Air Conditioning System by Using Evaporative Cooling
تحسين أداء مكثف منظومة تبريد نوع سبلت باستخدام تبريد تبخيري

Author: Lina Ismail Jassim لينا إسماعيل جاسم
Journal: Al-Ma'mon College Journal مجلة كلية المامون ISSN: 19924453 Year: 2011 Issue: 17 Pages: 230-246
Publisher: AlMamon University College كلية المامون الجامعة

Loading...
Loading...
Abstract

The reduction of energy demand is a major concern in areas with very hot weather conditions about 50Co. This can be achieved by using more energy efficient equipment. Evaporative cooling provides a low cost, energy efficient and environmental friendly alternative to traditional Air Conditioning. In this study, a simple design of applying indirect evaporative cooling which investigated experimentally to improve the coefficient of performance of split unit and power consumption. This model consists of a cooling pad behind condenser and injected water on it to reduce air temperature before it passes over the condenser. The experimental results show that the coefficient of performance increases by about 73% and the power consumption decreases by about 18%.

يتضمن هذا البحث، تصميم نموذج عملي لتحسين اداء منظومة التبريد، والتقليل من استهلاك الطاقة الكهربائية خاصة في المناطق ذات الدرجة الحرارية العالية، والتي تصل إلى حوالي 50 درجة مئوية وذلك باستخدام التبريد التبخيري. ان النموذج المستخدم يتضمن وسيط تبريد تبخيري, وهو مادة الحلفة بشكل يشبه تصميم المكثف الخاص بالسبلت، موضوعة خلف المكثف لتبريد الهواء قبل مروره على ملف المكثف، وحوض ماء ومضخة صغيرة وانابيب توصيل الماء. علما ان النتائج العملية تشير الى زيادة في معامل اداء المنظومة بنسبة 73% وانخفاض باستهلاك الطاقة الكهربائية بنسبة 18%.


Article
EXPERIMENTAL INVESTIGATION ON DIRECT EVAPORATIVE AIR COOLER PERFORMANCE WITH CELLULOSIC PADS

Author: Alaa Ruhma Al-Badri
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2017 Volume: 10 Issue: 4 Pages: 525-535
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

Evaporative cooling is an economic and environment-friendly technique for air cooling. This technique may involve air cooling with humidification (direct evaporative cooling) or sensible air cooling only (indirect evaporative cooling). In this study, the saturation efficiency of direct evaporative cooling (DEC) was investigated with rigid media cellulose (RMC) pads and compared with that of wood straw pads. Face air velocity on pads was varied between 0.5 and 3.0 m·s-1. The time change of ambient air dry-and wet-bulb temperatures, water temperature, and outlet air dry-bulb temperature were measured. For cellulosic pad, the experimental data showed that the saturation efficiency reached 71% of its steady state value in the first 100 seconds of operation and the final steady state value was reached after 600 seconds. The saturation efficiency decreases with the increase in the air velocity. It could be shown that the DEC is more efficient with wood straw pads compared to RMC pads. Predicted data using the published literature underestimated the saturation efficiency of DEC by about 18%.


Article
COOLING POULTRY HOUSE BY USING PAD MADE OF PALM RACHIS .
تبريد قاعة الدواجن باستخدام حشوه مصنعه من جريد النخيل .

Author: Ali Mazin Abdul-Munaim علي مازن عبد المنعم
Journal: Diyala Journal of Agricultural Sciences مجلة ديالى للعلوم الزراعية ISSN: 20739524 Year: 2009 Volume: 1 Issue: 2 Pages: 95-103
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

The experiment was conducted at Al- Rashidiya region belong to Baghdad governorate to study the possibility of using Article palm rachis in evaporative cooling unites as a wet pad. Three pad thickness were used with three different levels of exhaust fans including: one, two and three fans in the opposite direction during July and August of 2008 , to measure interior dry bulb temperature, cooling efficiency, interior relative humidity, air suction velocity, and air flow in order to determine which one of them is better in evaporative cooling when that pads are used in poultry house. a factorial experiment with a complete randomized design with three replication was used, the statistical analyses revealed that the pad which constructed from ( 8 ) cm pad thickness with two exhaust fans gave interior dry bulb temperature 28.2 c°, cooling efficiency 81.8 % , relative humidity 73.7%, air suction velocity 0.85 ms ,and air flow 15300 m3hr . The pad that constructed from ( 8 ) cm thickness with two exhaust fans was recommended because it showed the best performance during the experiment.Keywords

تم تنفيذ البحث في منطقة الراشديه ببغداد لدراسة امكانية استخدام مادة جريد النخيل بالتبريد التبخيري .استخدمت ثلاثة اسمك من الحشوه هي 4 و 8 و 12 سم مع عدد من مراوح السحب وهو استخدام مروحه ومروحتين وثلاث مراوح من الجهه المقابله خلال شهري تموز واب 2008 .قيست كل من درجة الحراره الجافه الداخليه م° وكفاءة التبريد % والرطوبه النسبيه الداخليه % وسرعة مقطع الهواء الخارج من الحشوات م/ثا ومعدل تصريف الهواء م3 /ساعه.طبق البحث بتجربه عامليه بالتصميم العشوائي الكامل بثلاث مكررات.ادت التوليفه المتكونه من السمك 8 سم مع استخدام مروحتين للسحب الى الحصول على درجه حراره جافه داخليه 28.8م° وكفاءة تبريد 81.8% ورطوبه نسبيه داخليه 73.7% وسرعة مقطع هواء خارج من الحشوات 0.85 م/ثا وتصريف هواء 15300 م3/ساعه.فيما اعطت التوليفه المتكونه من سمك 8 سم مع استخدام مروحتين للسحب اعلى كفاءة تبريد 81.8% لهذا ينصح باستخدامها لكونها ذات الاداء الافضل طوال مدة التجربه.


Article
An Investigation into Thermal Performance of Mist Water System and The Related Consumption Energy
دراسة الاداء الحراري لمنظومة رذاذ الماء و تاثيرها في استهلاك الطاقة

Authors: Najim Abid Jassim نجم عبد جاسم --- Firas Adel Abdulkareem Haris فراس عادل عبد الكريم حارس
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2014 Volume: 20 Issue: 9 Pages: 108-119
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Experimental tests were conducted to investigate the thermal performance (cooling effect) of water mist system consisting of 5μm volume median diameter droplets in reducing the heat gain entering a room through the roof and the west wall by reducing the outside surface temperature due to the evaporative cooling effect during the hot dry summer of Baghdad/Iraq. The test period was Fifty one days during the months May, June, and July 2012. The single test day consists of 16 test hours starting from 8:00 am to 12:00 pm. The results showed a reduction range of 1.71 to 15.5℃ of the roof outside surface temperature and 21.3 to 76.6% reduction in the daily heat flux entering the room through the roof compared with the case of not using water mist system. Also the results show a reduction range of 1.3 to 18.8℃ in the wall outside surface temperature. Finally numerical simulation with ANSYS-FLUENT.14 was conducted to compare its results with the experimental results of the roof and wall tests.

تم اجراء اختبارات عملية من اجل دراسة الاداء الحراري لمنظومة رذاذ الماء بقطيرات بمعدل قطر 5 مايكرون , في تقليل الحمل الحراري الداخل الى غرفة من خلال السقف و الجدار الغربي لها بخفض درجة حرارة السطح الخارجي نتيجة التاثير التبريدي التبخيري خلال فترة الصيف الحار و الجاف في بغداد/العراق. فترة الاختبارات كانت لمدة واحد و خمسون يوما خلال اشهر ايار و حزيران و تموز من العام 2012 , و تضمن يوم الاختبار 16 ساعة من الاختبارات ابتداءا من الساعة الثامنة صباحا و حتى الساعة الثانية عشرة ليلا. اظهرت النتائج العملية هبوط بمقدار 1.71 الى 15.5 درجة مئوية في حرارة السطح العلوي للسقف, و هبوطا بمقدار 21.3 الى 76.6 % من الحمل الحراري اليومي الداخل للغرفة من السقف. كذلك و بالنسبة للجدار الغربي فقد اظهرت النتائج هبوطا بمقدار 1.3 الى 18.8 درجة مئوية في حرارة السطح الخارجي للجدار. اخيرا تم استعمال برنامج المحاكاة الهندسي ANSYS-FLUENT.14 من اجل مقارنة النتائج العملية للسقف و الجدار مع النتائج النظرية المتولدة من هذا البرنامج.


Article
دراسة تأثير تدفق الماء على الفاعلية التبريدية في المبردة المقترحة ذات الأبواب الأربعة

Author: مناضل عباس حسن
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2018 Volume: 26 Issue: 8 Pages: 188-205
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

Previous research on the development of normal air cooler has been conducted into a proposed four-door air cooler. The results indicated that the effectiveness of the proposed air cooler (75.4% - 30.3%) was higher than the effectiveness of the normal air cooler (70.4% - 15.2%) at temperatures of (42oC - 33oC) but the effectiveness of both air coolers corresponded to the high temperature (42oC - 43oC). As well as the relative humidity of the air coming out of the proposed air cooler was higher than the normal air cooler at times of high temperature degrees (42oC - 33oC). However, the case is reversed at times of temperature degrees higher than (42oC). This means that the relative humidity of the air coming out of the proposed air cooler was lower. Therefore, it was necessary to study the effect of water flow on the cooling effectiveness in the proposed air cooler.A four-door air cooler with variable flow rate was designed and manufactured. A practical study and test was carried out and the optimal flow of water in the air cooler was determined to be 1800 L/hr. Another practical study and test was carried out to compare the performance of the normal air cooler against the proposed one with optimum water flow. The results showed that the proposed air cooler with the optimal water flow was the most effective and the most reduction of the temperature of the air inside the air cooler at various times of the day. It was noticeable that the difference between them increased in hot weather hours. The air coming out of the proposed air cooler with optimal water flow was more humid than the normal air cooler at different times of the day. The results indicate that the performance of the proposed air cooler with optimal flow is better than normal air cooler performance in most weather conditions in Iraq.

لقد تم إجراء بحث سابق حول تطوير المبردة الاعتيادية إلى مبردة مقترحة ذات اربعة أبواب وكانت النتائج إن فاعلية المبردة المقترحة (75.4% - 30.3%) أعلى من فاعلية المبردة الاعتيادية (70.4% - 15.2%)عند درجات حرارة (42oC - 33oC)، إلا إن فاعلية المبردتين تتطابق عند درجاتالحرارة العالية(43oC - 42oC) وكذلك الرطوبة النسبية للهواء الخارج من المبردة المقترحة كانتأعلى من المبردة الاعتيادية في الاوقات التي تكون فيها درجات الحرارة عالية (42oC - 33oC).أما في الأوقات التي تكون فيها درجات الحرارة أعلى من (42oC) فتكونالحالة معكوسة، أي الرطوبة النسبية للهواء الخارج من المبردة المقترحة أقل.فكان لابد من دراسة تأثير تدفق الماء في الفاعلية التبريدية في المبردة المقترحة.تم تصميم وتصنيع مبردة هواء ذات أربعة أبواب وذات معدل تدفق ماء متغير،وتم اجراء دراسة واختبار عمليين وتم تحديد التدفق الأمثل للماء في المبردة وهو (1800 L/hr).تم إجراء دراسة واختبار عمليينآخرين لمقارنة أداءكل من المبردة المقترحة ذات التدفق الأمثل مع المبردة الاعتيادية وكانت النتائج أن المبردة المقترحة ذات التدفق الأمثل هي الأعلى فاعلية والأكثر خفضا لدرجة حرارة الهواء داخل المبردة في مختلف أوقات اليوم ومن الملاحظ أن الفرق بينهما يزداد في ساعات الجو الحار. إن الهواء الخارج من المبردة المقترحة ذات التدفق الأمثل كان أكثر رطوبة من المبردة الاعتيادية في مختلف أوقات اليوم، كماتشير النتائج إلى أن أداء المبردة المقترحة ذات التدفق الأمثل أفضل من أداء المبردة الاعتيادية في أغلب الظروف الجوية بالعراق.