research centers


Search results: Found 3

Listing 1 - 3 of 3
Sort by

Article
Effect of Continuous and Intermittent Aeration Modes on the Efficiency of the Continuous Flow Extended Aeration Activated Sludge Systems
مقارنة تأثیر أسلوبي التھویة المستمرة والتھویة المتقطعة على كفاءة أنظمة الحمأة المنشطة ذات التھویة المطولة والجریان المستمر

Authors: Kossay K. Al-Ahmady قصي كمال الدین الاحمدي --- Ammar A. Al-Sultan عمار عبدلله السلطان
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 13 Part (A) Engineering Pages: 498-512
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In this research an experimental plant was constructed and operated in order to study the efficiency of the intermittent aeration activated sludge system that operated at the ratio of (On/Off aeration times) (15min/15min), (30min/30min), (60min/60min), (90min/90min) and (120min/120min) and compare their performance with the continuous flow extended aeration activated sludge. The results of the study revealed that; extended aeration reactor is more efficient in removing organic matter than the intermittent aeration reactors. At the hydraulic detention times of (24, 18 and 32), 100%, 65% and 100% of effluent readings had organic concentration less than the acceptable effluent level in compare to 75%, 60% and 80% at the (90min/90min) reactor. In comparison of On/Off aeration times, (90min/90min) reactors provide the best organic removal. All readings from the extended aeration and (15min/15min), (60min/60min), and (90min/90min) reactors were within the acceptable level for effluent suspended solids while the effluent concentrations from the (120min/120min) reactors were higher. The results also indicated that, intermittent aeration reactors are better in removing phosphorous than the extended aeration. At the detention times of 24 and 18 hours, 8% and 6% of readings from the extended aeration reactors had (PO4 ≤ 5 mg/l) in compare to 90% and 52% of readings from the (60min/60min) reactor. At detention time of 32 hours, 32% of readings from the extended aeration reactor had (PO4 ≤ 2 mg/l) in compare to 72% for the (60min/60min) reactor. Higher phosphorus removals were recorded at (60min/60min) reactors.

تم في هذا البحث دراسة تأثير التهوية المتقطعة على كفاءة أنظمة الحمأة المنشطة ذات الجريان المستمر وذلك من خلال إنشاء وتشغيل محطة اختبارية تعمل بنظام الجريان المستمر والتهوية المتقطعة وبأوقات تشغيل وإيقاف تهوية (15min/15min)، (30min/30min)،(60min/60min) ،(90min/90min)،(120min/120min) ومقارنتها مع نظام الحمأة المنشطة ذو الجريان المستمر والتهوية المطولة حيث استخدمت مياه المطروحات الصناعية لمصنع أدوية نينوى مصدرا للفضلات السائلة. أثبتت نتائج البحث أن نظام التهوية المطولة ذو كفاءة أعلى في إزالة المواد العضوية من نظام التهوية المتقطعة، حيث كانت 100% و 65 % و 100% من القراءاتلتراكيز المياه الخارجة من مفاعلاتالتهوية المطولة العاملة بأوقات مكوث هيدروليكي (24، 18 و 32) ساعة تقع ضمن محددات الطرح المحلية مقابل 75% و 60% و 80% لمفاعلات التهوية المتقطعة (90min/90min) العاملة بنفس اوقات المكوث وعلى التوالي،وكان افضل تشغيل متقطع لإزالة المواد العضوية هو (90min/90min). وكانت جميع القراءات المسجلة لتراكيز المواد الصلبة العالقة الخارجة من مفاعلات التهوية المطولة والتهوية المتقطعة (15min/15min)،(60min/60min) و (90min/90min)ضمن حدود مواصفات الطرح المعتمدة، كماتفوقتمفاعلات التهوية المستمرة على مفاعلات التهوية المتقطعة من حيث انخفاض تراكيز المواد الصلبة العالقة في المياه الخارجة،كذلككانت الدورات الطويلة لتشغيل وإيقاف التهوية (120min/120min) ذات كفاءة اقل من حيث تراكيزهذه المواد. كما واثبتت النتائج ان مفاعلاتالتهوية المتقطعة افضلمن مفاعلات التهوية المستمرة في إزالة الفسفور حيث كانت 8% و 6% من تراكيز الفوسفات في المياه الخارجة من مفاعلات التهوية المطولة العاملة بأوقات مكوث هيدروليكي (24 و 18) ساعة اقل او يساوي 5 ملغم/لتر، مقابل 90% و 52% لمفاعلات التهوية المتقطعة (60min/60min) العاملة بنفس اوقات المكوث وعلى التوالي،وكانت 32% من تراكيز المياه الخارجة من مفاعل نظام التهوية المطولة العاملة بوقت مكوث هيدروليكي 32 ساعة ذات تركيز فوسفات اقل او يساوي 2 ملغم/لتر مقابل 72% لمفاعل التهوية المتقطعة (60min/60min). وان أفضل تشغيل متقطع لإزالة الفسفور هو (60min/60min).


Article
Performance Evaluation of Trickling Filter and Extended Aeration of Wastewater Treatment Plants
تقييم اداء المرشح النقطي والتهوية الممتدة في محطات معالجة مياه الصرف الصحي

Authors: Saad Naif Awad سعد نايف عواد --- Basim Hussein Khudair Al-Obaidi باسم حسين خضير العبيدي
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2020 Volume: 26 Issue: 3 Pages: 93-99
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In recent decades, there has been increasing interest in wastewater treatment because of its direct impact on the environment and public health. Over time, other forms of treatment have been developed and modified, including extended aeration. This process is included in the suspended growth system. In this paper, a comparative study was conducted between the efficiency of the extended aeration plant and that of the trickling filter plant in removal of BOD and COD. The method of comparison was done by knowing the value of the pollutant before and after the treatment and then extra dr.basimal-obaidy@coeng.uobaghdad.edu.iq ct the removal ratio of each pollutant within each plant. The results showed that the percentage of removal of BOD in the trickling filter was 79.5% while in extended aeration was 90.7%. The efficiency of COD removal was 60% in trickling filter and 86% in extended aeration. The study was carried out at the Barrakiyah WWTP in Najaf province in Iraq. As the plant contains these two types of treatment, and the study has been achieved through monthly examinations over a full year.

خلال العقود الاخيرة اصبح الاهتمام متزايدا بعملية معالجة مياه الصرف الصحي نظرا لما تمثله من تأثير مباشر على البيئة والصحة العامة . بمرور الوقت تم تطوير و تعديل اشكال اخرى للمعالجة ومنها عملية التهوية الممتدة . هذه الوحدة تعتبر ضمن نظام النمو المعلق . في هذه الورقة البحثية تم تقديم دراسة مقارنة بين كفاءة الفلتر وكفاءة التهوية في ازالة BOD و COD. طريقة المقارنة تمت من خلال معرفة قيمة الملوث قبل وبعد المعالجة ومن ثم استخراج نسبة الازالة لكل ملوث داخل كل محطة. حيث اظهرت النتائج ان النسبة المئوية لأزالة BOD في التهوية الممتدة 90.7% بينما في الفلتر كانت 79.5% . أما كفاءة ازالة COD فقد كانت 60% في المرشح المنقط و 86% في التهوية الممتدة. جرت الدراسة في محطة البراكية في محافظة النجف في العراق . حيث ان المحطة تحتوي على هذين النوعين من المعالجة و قد تم تحقيق الدراسة من خلال الفحوصات الشهرية على مدى عام كامل .


Article
Advance Wastewater Treatment; Biological Removal of Eutrophic Nutrients
المعالجة المتقدمة لمياه الصرف الصحي , الازالة البايولوجية لمغذيات الاثراء الغذائي

Authors: Marwa F. Abed --- Mohammed Y. AL- Ani --- Faris H. Al-Ani
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 5 Part (A) Engineering Pages: 1131-1142
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In this study, a lab scale different activated sludge configurations methods were used to treat a municipal wastewater from effluent of; primary sedimentation tank of Al-Rustamiya wastewater treatment plant located near Baghdad city to remove organic load, nitrogen and phosphorus from the period of 15 July 2012 to 22 May 2013.Biological treatment systems were conventional activated sludge (CAS) , extended aeration , anaerobic-anoxic-aerobic( A2O) , anoxic-aerobic (MLE) and anaerobic –oxic(A/O). During the operation periods, the average removal efficiency of BOD5, COD and TSS is 81.9, 77.7 and 85.8 respectively regardless of the fluctuation in influent quality. In addition the results show removal efficiency of ammonia, nitrate, nitrite and phosphorus with ranges (61-85.8), (34-81.7) , (35-81.4) (32.3-85.54) % respectively. The biological treatment systems produced high quality effluent which can achieve the Iraqi limitations of rivers maintenance for all measured parameters.

في هذه الدراسة، على نطاقالمختبر تم استخدام تشكيلات أنظمة معالجةحمأة منشطة مختلفة لمعالجة مياه الصرف الصحي البلدية والخارجة من حوض الترسيب الاولي لمحطة معالجة الرستمية الواقعة بالقرب من مدينة بغداد لازالة الاحمال العضوية,النتروجين والفسفور في الفترة من 5 يوليو 2012 الى 22 مايو 2013. انظمة المعالجة البايولوجية هي الحماة المنشطة التقليدية ,التهوية المطولة ,(اللاهوائي –هوائي محدد – هوائي) ,( هوائي محدد – هوائي) و (اللاهوائي - هوائي) .أثناءفترات العمل، فإن متوسط كفاءة الإزالة لكل من الاوكسجين المطلوب حيويا ، الاوكسجين المطلوب كيميائيا والمواد االعالقة الكلية هو81.9، 77.7و 85.8 %على التواليبغض النظر عنالتذبذب فينوعية المياه الواردة. بالإضافةالى ان النتائج تظهر إزالةللأمونيا,النترات ,النتريت والفوسفورضمن مدى(61- 85.8) ,(34-81.7) ,(35-81.4) و (32.3-85.54) %على التوالي.أن أنظمةالمعالجة البيولوجية انتجت نوعيةتصريف خارج بنوعية ممتازة والتييمكن أن تحققحدود المواصفاتالعراقيةلصيانة الانهارو لجميعالمعايير التي تم قياسها.

Listing 1 - 3 of 3
Sort by
Narrow your search

Resource type

article (3)


Language

English (2)

Arabic (1)


Year
From To Submit

2020 (1)

2015 (1)

2014 (1)