research centers


Search results: Found 7

Listing 1 - 7 of 7
Sort by

Article
Bulid-up a flow injection analysis unit for ammonium determination in the Shatt Al-Arab water.
بناء وحدة تحليل حقن جرياني لتقدير أيون الأمونيوم في مياه شط العرب.

Loading...
Loading...
Abstract

Abstract - A Semi- automated flow injection analysis (FIA) unit was build-up for determination of ammonium ion in water samples from the Shatt Al-Arab River during the period from October 2009 to September 2010. The ammonium concentrations in water have been measured, at each of the eight stations (Qurnah (Tigres), Qurnah (Euphrates), Saad Bridge, Garmat Ali, Ashar, Abu Al-Khaseeb, Al-Seeba and Fao), monthly. The results indicated that (NH4+) concentrations increasing during May, June and July, 2010 especially in stations 5 and 6 were 0.95, 1.35 µg/ml , 1.30, 1.25 µg/ml and 1.45, 1.40 µg/ml, respectively. The FIA unit was applied successfully for the determination of ammonium in Shatt Al-Arab water sample and provide simple, fast, and reproducible methods for ammonium determination in water.

المستخلص - تم بناء وحدة تحليل حقن جرياني شبه ذاتية لتقدير أيون الأمونيوم في عينات مياه شط العرب شهرياً للفترة من تشرين الأول 2009 لغاية أيلول2010 في ثمان محطات ]القرنة (دجلة)، القرنة (الفرات)، جسر سعد، گرمة علي، العشار، أبو الخصيب، السيبة والفاو[ تشير النتائج الى زيادة في تراكيز أيون الأمونيوم خلال أشهر مايس، حزيران وتموز 2010 وخصوصاً في المحطات 5 و 6 وكالأتي (1.35, 0.95)، (1.25, 1.30) و(1.40, 1.45) مايكروغرام/مل وعلى التوالي. أن وحدة تحليل الحقن الجرياني لتقدير أيون الأمونيوم طبقت بنجاح ووفرت هذه الطريقة بسيطة وسريعة وأستعادية.


Article
Determination of Chloramphenicol from pure and pharmaceutical preparations using FIA- Spectrophotometric methods

Author: Kamal Mustafa Mahmoud كمال مصطفى
Journal: Iraqi National Journal Of Chemistry المجلة العراقية الوطنية لعلوم الكيمياء ISSN: 22236686 Year: 2007 Issue: 28 Pages: 634-641
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

AbstractFlow injection spectrophtometric method was described for the trace determination of chloramphenicol. This method depends upon the reduction of the nitro group of the chloramphenicol to the amino group using Zn- reductor mini-column, then diazotization of the amino group with nitrous acid and coupling with 8-hydroxyquinoline in alkaline medium to give an intense water soluble and stable azo dye with a maximum absorption obtained at a wavelength of 485 nm. The linear calibration curve was applied in the range of (0.5- 50 μg ml-1). The relative standard deviation was estimated as ≤ 1.4% for (30 μg ml-1) chloramphenicol solution of 10 successive injections. This method was found to be easy, simple, reproducible, high precession and very sensitive for the determination of chloramphenicol in pure form and in pharmaceutical preparations comparing with British pharmacopoeia method.

الخلاصة تم تقدير كميات ضئيلة من مادة الكلورامفينيكول داخل المستحضرات الصيدلانية ضوئياً وبأستخدام التحليل الحقن الجرياني. تعتمد الطريقة على أختزال مجموعة النايترو في الكلورامفينيكول إلى مجموعة الأمينو بأستخدام عامود الأختزال المعبأ بـ ملغم الخارصين ومن ثم تحويل المادة المختزلة إلى ملح الدايزونيوم بواسطة حامض النتروز، وأقتران الأخير مع الكاشف العضوي 8-هايدروكسي كوينولين في الوسط القاعدي لتكوين مركب تعتمد شدة لونه على كمية الكلورامفينيكول الموجود في المحلول المائي حيث أظهرت أعلى امتصاصية عند اعظم طول موجي 485 نانوميتر. أنطبق قانون بير-لامبرت على مدى التراكيز تتراوح بين 0.5-50 مايكروغرام / مللتر حيث كان الأنحراف القياسي النسبي أقل أو يساوي 1,4% للتركيز 30 مايكروغرام/مللتر........أن الطريقة بسيطة وسهلة ودقيقة وحساسة وذات تطابقية وتوافقية جيدة ولهذا فقد تم تطبيقها لتقدير الكلورا مفينيكول الموجود بشكل مستحضرات صيدلانية وتم تقييم النتائج العملية للطريقة المستخدمة بنتائج الطريقة القياسية المعتمدة من قبل الدستور البريطاني


Article
SPECTROPHOTOMETRIC DETERMINATION OF HUMAN SERUM ALBUMIN BY A HOME-MADE SEMI-AUTOMATED
التقدير الطيفي للآلبومين في مصل الدم البشريبأستخدام نظام حقن جرياني محلي الصنع شبه آلي

Loading...
Loading...
Abstract

The bromcresol green method was applied for spectrophotometric determination of albumin by using a home-made semi-automated flow injection in some pharmaceutical preparation with recoveries of 98.5-102 % and 54 serum samples of male and female patients in the range 32.48-51.25 g/L.The method is convenient, simple and sensitive with detection limit (2x noise) 0.625 g/L. The r.s.d % is 0.74 % for 8 measurements of 40 g/L albumin.

تم التقدير الطيفي للآلبومين بطريقة بروموكريسول الأخضر بأستخدام جهاز تحليل حقن جرياني محلي الصنع في المستحضرات الصيدلانية و بأستعادية 98.5- 102% وكذلك في مصل دم الذكور و الآناث بمدى 32.85-51.25 غم/ لتر. اثبتت الطريقة بأنها مناسبة و بسيطة و حساسة و بحد كشف 0.625 غم / لتر و انحراف معياري قياسي 0.74 % لثماني قراءات من محلول 40 غم / لتر البومين.


Article
Determination of hydroquinone in pure form and pharmaceutical preparations using Batch and FIA-Merging Zone techniques with spectrophotometric detection
التقدير الاني للهايدروكوينون بصيغته النقية والمستحضرات الصيدلانية باستخدام طريقتي الوجبة والحقن الجرياني-اندماج المناطق والتحسس بالطريقة الطيفية

Authors: Bushra B.Al-Mosulli بشرى بشير الموصلي --- Aseel S.Al-Jomaili اسيل صلاح الجميلي --- Hamssa S.Al-Janabi همسة شاكرالجنابي
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2015 Volume: 56 Issue: 1B Pages: 265-274
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this study, anew, rapid and sensitive batch and flow injection-merging zones spectrophotometric methods for the determination of hydroquinone in a pure material and in pharmaceutical preparation were proposed.These methods were based onthe oxidative-coupling reaction of HQ with 2,4-dinitrophenylhydazine(DNPH) in the presence of sodium periodate and sodium hydroxide to form a dark brown water slouble dye that is stable and has maximumabsorption at 530nm, graphs of absorbance versus concentration show that Beer's low is obeyed over the concentration rang of 1-40 and 3-300 µg.ml-1 of hydroquinone, with detection limits of 0.162 and 0.510 µg.ml-1of hydroquinone for batch and FIAmethods, respectively. The optimized FIAsystem is able to determine hydroquinone with a through put of83h-1.All different chemical and physical experimental parameters affecting on the development and stability of the colored productwere carefully studied and the proposed methods were successfully applied for the determination of hydroquinone in pharmaceuticalpreparations.

تتضمن الدراسة تطوير طريقة طيفية جديدة وسريعة للتقدير الكمي لمقادير ضئيلة من الهايدوكوينون في المحاليل المائية والمستحضرات الصيدلانية باستخدام طريقتي الدفعة التقليدية وتقنية الحقن الجرياني-اندماج المناطق.تعتمد الطريقتين على تفاعل الازدواج التأكسدي للهايدوكوينون مع كاشف 2و4-داي نايتروفنيل هايدرازين المؤكسد في الوسط قاعدي حيث تتكون صبغة آزو بني غامقة مستقرة وذائبة في الماء اعطت اعلى امتصاص عند طول موجي 530 نانومتر.تشير منحنيات الامتصاص مقابل التركيز انها مطاعةلقانون بير ضمن مدى التراكيز 1-40 , 3-300 مايكروغرام.مل-1 من الهايدروكوينون وبحدود كشف 0.162 , 0.52 مايكروغرام.مل-1 من الهايدوكوينون لطريقتي الدفعة والحقن الجرياني على التوالي وبمعدل نمذجة 83 أنموذج في الساعة بطريقة الحقن الجرياني, تم دراسة الظروف المثلى للتفاعل وجميع المتغيرات الفيزيائية ووالكيميائية المؤثرة على استقرارية الصبغة الناتجة بدقة وضبط عاليين, طبقت الطريقتين بنجاح في المستحضرات الصيدلانية الحاوية على الهايدوكوينون.


Article
Fistula in Ano; the Correlation of Pre-Operative Magnetic Resonance Imaging with Video Assisted Anal Fistula Treatment Findings

Authors: Hussain J K Alsalami --- Laith A S Alshareefi --- Falah D Salih
Journal: Karbala Journal of Medicine مجلة كربلاء الطبية ISSN: 19905483 Year: 2017 Volume: 10 Issue: 3 Pages: 3804-3809
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

background: Fistula-in-ano (FIA) is a common medical problem. Magnetic resonance imaging (MRI) is an excellent modality for the pre-operative evaluation of this condition. Video assisted anal fistula treatment (VAAFT) is a relatively new modality introduced in 2006, and is both diagnostic and operative.Aim: To correlate MRI findings with video assisted anal fistula treatment findings.Patients and methods: Thirty-five patients with clinically diagnosed FIA, had a pelvic MRI followed by VAAFT surgery.Results: Mean age was 42 years. In one case both MRI and VAAFT revealed a sinus. In 29 cases (82.8 %) there was concordance regarding the presence of an FIA, both tracts and internal openings. In 5 cases (14.2%), there was no concordance regarding the presence of an internal opening.Conclusion: MRI is essential in the pre-operative assessment of FIA especially for clinically complex fistulas.


Article
New Innovative Valve for Flow Injection to Determine the Total Phenols and Antioxidant in Mushroom

Authors: Dakhil N. Taha --- Kadhim K. Hashim --- Suhaam T. Ameen
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2016 Volume: 24 Issue: 7 Pages: 1820-1835
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

In this study a new valve B had been designed and constructed in the analytical laboratory by using local available facilities and resources. This was applied to determine the total phenols (TP) in plants extracts using gallic acid (GA) as a standard. The results were compared to those obtained from a standard valve A. It was found that under the optimized experimental conditions and using calibration graphs with range of 1.0 - 40.0 mgL-1 (r2=0.9986) and 1.0–50.0 mgL-1 (r2=0.9993) for the valves A and B respectively, the limit of detection (LOD) in the aqueous solution was 0.05 mg.L-1 for both valves. Total phenol content and antioxidant activity of methanol extracts from mushroom were determined and compared to those values obtained for gallic acid. Flow injection analysis (FIA) determination of the TP content was performed using the Folin-Ciocalteu Reagent (FCR), while antioxidant activity was measured by reaction with 1,1-diphenyl-2-picry RCydrazyl radical (DPPH assay). The values of phenolic compounds content and antioxidants activity which were determined by valve B were notably higher than these in valve A. Finally, both valves A and B showed high sensitivity, flexibility, extend range of linearity, rapidity and ease of use. Also their material were not expensive, therefore using them is successful to determine the total phenols and antioxidants.

تم تصميم وتركيب صمام جديد (ب) لمنظومة الحقن الجرياني في مختبر الكيمياء التحليلية باستعمال مواد متوفرة تجاريا, وقد استعمل هذا الصمام في تقدير الفينولات الكلية ومضادات الاكسدة في المستخلصات النباتية باستخدام حامض الكاليك كمحلول قياسي. تم مقارنة النتائج مع تلك المستحصلة من استعمال الصمام (أ) وتحت نفس الظروف التجريبية للصمامين حيث وجدت الخطية ضمن مدى (1.0-40.0 mgL-1 ) (R2 = 0.9986 ( و( 1.0 -50.0 mgL-1 ) (R2 = 0.9993 ) للصمامين (أ) و (ب) على التوالي, مع حد كشف ((LOD = 0.05 mgL-1 لكلا الصمامين. المحتوى الكلي للفينولات وفعالية مضادات الاكسدة للمستخلص الكحولي للفطر قدرت وتمت المقارنة بين النتائج المستحصلة لحامض الكاليك حيث تم تقديرها باستعمال تقنية الحقن الجرياني واستعمال كاشف فولن للكشف عن الفينولات الكلية بينما استعمل كاشف (DPPH ) لقياس فعالية الاكسدة وقد لوحظ ان قيم المركبات الفينولية ومضادات الاكسدة التي قيست باستعمال الصمام (ب) كانت نوعا ما اعلى من تلك المقاسة باستعمال الصمام (أ). في النهاية كلا الصمامين اظهرا مرونة وحساسية عالية, مدى واسع من الخطية, سهولة في الاستعمال, سرعة في القياس كذلك فان المواد الاولية المستعملة في تركيب الصمامين متوفرة ورخيصة الثمن ولهذا تم استعمالها بنجاح في تقدير الفينولات الكلية ومضادات الاكسدة.


Article
Determination of Doxycycline Hyclate by Batch and Reverse Flow Injection Analysis Based on the Oxidative Coupling Reaction with 3-Methyl-2-benzothiazolinone Hydrazone hydrochloride (MBTH)
تقدير الدوكسي سايكلين هايكلات بطريقتي الدفعة والحقن الجرياني العكوس اعتمادآ على تفاعل الاكسدة والازدواج مع كاشف 3-مثيل-2-بينزوثايازولينون هايدرازون هايدروكلورايد

Authors: Sadeem Subhi Abed سديم صبحي عبد --- Omar T. Hussein عمر طه حسين
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2016 Volume: 13 Issue: 2ملحق ابحاث المؤتمر الوطني الثاني للكيمياء Pages: 489-497
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

New, simple and sensitive batch and reverse FIA spectrophotometric methods for the determination of doxycycline hyclate in pure form and in pharmaceutical preparations were proposed. These methods based on oxidative coupling reaction between doxycycline hyclate and 3-methylbenzothiazolinone-2-hydrazone hydrochloride (MBTH) in the presence ammonium ceric sulfate in acidic medium, to form green water-soluble dye that is stable and has a maximum absorbance at 626 nm. A calibration graph shows that a Beer's law is obeyed over the concentration range of 1-80 and 0.5-110 μg.mL-1 of DCH for the batch and rFIA respectively with detection limit of 0.325 μg.mL-1 of DCH for r-FIA methods. All different chemicals and physical experimental parameters affecting the development and stability of the colored product were carefully studied. The proposed methods were successfully applied for the determination of DCH in pharmaceutical preparations.

يتضمن البحث تطوير طرائق طيفية جديدة وبسيطة للتقدير الكمي لمقادير ضئيلة من الدوكسي سايكلين هايكلات في المحاليل المائية والمستحضرات الصيدلانية باستخدام طريقة الدفعة والحقن الجرياني العكوس,تعتمد الطريقة على تفاعل الاكسدة والازدواج للدوكسي سايكلين هايكلات مع كاشف 3-مثيل-2-بينزوثايازولينون هايدرازون هايدروكلورايد في وسط حامضي حیث تتكون صبغة خضراء مستقرة وذائبة في الماء والتي اعطت اعلى امتصاص عند طول موجي 626 نانوميتر. تشير منحنيات الامتصاص مقابل التركيز بان قانون بير ينطبق ضمن مدى التراكيز 1-80 و 0.5-110مايكروغرام.مل-1 للدفعة والحقن الجرياني العكوس على التوالي وبحد كشف0.325مايكروغرام.مل-1 من الدوكسي سايكلين هايكلات وبمعدل نمذجة 72 نموذج في الساعة بطريقة الحقن الجرياني العكوس, تم دراسة الظروف المثلى للتفاعل وجميع المتغيرات الكيمائية والفيزيائية بدقة, طبقت الطريقة بنجاح على المستحضرات الصيدلانية الحاوية على الدوكسي سايكلين هايكلات.

Listing 1 - 7 of 7
Sort by
Narrow your search

Resource type

article (7)


Language

English (7)


Year
From To Submit

2017 (1)

2016 (2)

2015 (1)

2011 (1)

2009 (1)

More...