research centers


Search results: Found 21

Listing 1 - 10 of 21 << page
of 3
>>
Sort by

Article
Prediction slurry reactor design under uncertainty using CFD model
استخدام تقنية حركة الموائع الحسابية لمعالجة نموذج مفاعل الملاط تحت ظروف غير محددة

Authors: Ali A. Jazei --- Nabel K. Abd-Ali
Journal: KUFA JOURNAL OF ENGINEERING مجلة الكوفة الهندسية ISSN: 25230018 Year: 2010 Volume: 2 Issue: 1 Pages: 63-80
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

Mechanically agitated reactors find wide range of applications for solid suspension and mixing in the chemical, biochemical, and mineral processing industries. Understanding the solids dynamics in these reactors is necessary to improve the design and operation of such reactors. Computational fluid dynamic (CFD) models are often useful in this regard, as it can provide significant insights into the flow and mixing of the phases involved. However, the model predictions need extensive evaluation with experimental results before they can be confidently used for the scale-up and optimization of large scale reactors. In the present work the predictive capabilities of CFD techniques as applied to solid-liquid stirred vessels are investigated. Suspensions of sand (diameter equal to 327 m) in water are studied. Eulerian-Granular multiphase model was simulated using FLUNT 6.3.26 to predict the slurry reactor design under uncertainty. The profiles obtained with the Eulerian-Granular approach coupled with the Eulerian, Granular models, and experimental data for comparison purposes. The present model provides an improvement of the predictions in the lower part of the vessel, with respect to the Eulerian model; while the same results can be observed in the rest of the tank where the solid concentration is lower. It seems that the interaction phenomena between the solid and the liquid phases and those among the solid particles do not vary appreciably for low solid concentrations, while at higher concentration some effects become noticeable. It was found that the quasi-steady state behavior of the sand in the mixing tank reached after 20 sec, also after 10 sec were the free surface of the static pressure will be growth until reach peremptory shape after 20 sec. The present model provides a proper representation for the solid distribution, by adopting particle drag coefficient.

وجدت المفاعلات ذات الخلط الميكانيكي المدى الواسع في التطبيقات في مجال الهندسة الكيمياوية والبايوكيمياوية وهندسة المعادن. ان فهم ديناميكية المواد الصلبة العالقة ضروري لتحسين تصميم وتشغيل هكذا نوع من المفاعلات. وغالبا ما تستخدم نماذج ديناميكية الموائع الحسابية (CFD) لتوفير صورة واضحة حول الجريان والخلط للأطوار المتعددة. على أي حال فان عملية التنبؤ بالنموذج تحتاج إلى نتائج تجارب عملية واسعة قبل الشروع بتصميم المفاعل الصناعي وكذلك استخدام طرق الأمثلية (Optimization) لإيجاد أفضل التصاميم.تم خلال هذا البحث تحري إمكانية تقنية (CFD) لمعالجة نموذج مفاعل ذو خلاط يحتوي على طورين (صلب- سائل)، الطور السائل متمثلاً بالماء والطور الصلب متمثلاً بالرمل الحبيبي بقطر (m 327). وقد تم اعتماد نموذج يوليرين-الحبيبي المتعدد الاطوار لتحري تصميم مفاعل الملاط (slurry) تحت ظروف غامضة، وتمت مقارنة النموذج الحالي مع نماذج ونتائج عملية سابقة مستخدمة من قبل باحثين سابقين، وقد أعطى النموذج المقدم في هذا البحث تنبؤ مقبول عن الجزء الأسفل من المفاعل بالمقارنة مع نموذج (Eulerian)، كما بين ان ظاهرة التداخل بين الأطوار المختلفة أو بين جسيمات المادة الصلبة ذاتها لم تتغير عند التراكيز الواطئة للمادة الصلبة وكانت اقل وضوحاً، بينما في التراكيز العالية تصبح هذه الظاهرة قابلة للملاحظة. وقد تم الاستعانة ببرنامج (FLUNT 6.3.26) لحل المعادلات الخاصة بهذا النموذج . تم التوصل في هذا البحث الى ان عملية الخلط للرمل داخل الخزان تصل الى حالة خلط شبه مستقرة بعد) (20 ثانية, كما ويبدأ السطح الحر للضغط الساكن بالنمو بعد مرور(10) ثانية الى ان يصل الى شكله النهائي بعد مرور) (20 ثانية. ان النموذج الحالي يوفر صورة دقيقة عن طبيعة توزيع تركيز المادة الصلبة وذلك بالأخذ بنظر الاعتبار معامل الإعاقة (drag coefficient) للجسيمات الصلبة.

Keywords

Slurry Reactor --- CFD --- Fluent --- Multiphase model


Article
Experimental and Numerical Investigation to Evaluate the Performance of U-Longitudinal Finned Tube Heat Exchanger
تحقيق عملي ونظري لتقييم أداء مبادل حراري من نوع الأنبوب المزعنف بزعانف طولية على شكل حرف U

Loading...
Loading...
Abstract

Experimental and numerical investigation has been performed in this work to evaluate the performance for U-longitudinal finned tube heat exchanger. Four pairs of U-shaped longitudinal fins were selected and manufactured from copper material and welded on the straight copper tube. The inner tube is inserted inside insulated galvanized tube, sheet and roll insulation (arm flux) and glass wool have been utilized to cover inner and outer surface of galvanized tube for reducing heat losses. Air at various mass flow rates (0.03 to 0.07)kg/sec flows through annuli and de-ionized water at Reynold's numbers ranging from (270 to 1900) flows through the inner tube. Performance of (smooth and finned) tube heat exchanger was investigated experimentally. Experimental results showed (1.744 to 2.534) enhancement ratio when using U-longitudinal fins. Empirical correlations for air, water were represented by Nusselt's number. Numerical simulation has been carried out on present heat exchanger to analyze flow field and heat transfer using FLUENT package 14. The comparison between experimental work and numerical results showed good agreement.

في هذه الدراسة, تم انجاز تحقيق عملي وعددي لمبادل حراري من نوع الانبوب المزعنف بزعانف طولية علئ شكل حرف (U) من اجل دراسة اداءه الحراري. اربعة ازواج من الزعانف الطولية ذات شكل (U) تم تصميمها وتصنيعها من مادة النحاس وثبتت علئ انبوب نحاس الذي اولج داخل انبوب مصنع من مادة الكلفنايز ومعزول بعوازل من الداخل والخارج لتقليل الحرارة المفقودة. هواء عند معدلات تدفق كتلية تتراوح بين (0.03 الئ0.07 ) كغم/ثانية يجري خلال الفراغ الحلقي وماء منزوع الايونات ذو ارقام رينولدز تتراوح بين (270 الئ 1900) يجري خلال الانبوب الداخلي. اداء المبادل الحراري بالحالتين ( الاملس والمزعنف ) تمت دراسته. النتائج العملية بينت ان نسبة التحسين كانت (1.744 الئ 2.534) في حال استخدام المبادل الحراري ذو الانبوب المزعنف. علاقات تجريبية لجانب الهواء والماء تم تقديمها بدلالة رقم نيسلت. محاكاة عددية تم انجازها للمبادل الحراري لتحليل جريان المائع وانتقال الحرارة باستخدام البرنامج المتخصص 14ANSYS FLUENT. بينت المقارنة بين النتائج العملية والعددية وجود تطابق مقبول.


Article
NUMERICAL ANALYSIS OF A MODEFID AIRFOIL FOR WIND TURBINE
التحليل العددي لمطيار عنفة رياح

Author: Wisam Abd Mohammed Al-Shohani وسام عبد محمد محمود الشوهاني
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2014 Volume: 7 Issue: 2 Pages: 83-97
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

This paper presents a numerical analysis of new airfoil, TCB6612, and compared with respect to standard airfoil NACA4412 using them in wind turbine blade. The main objective of this work is to enhance the aerodynamic performance of airfoil by changing the geometry of the airfoil in order to increase the overall power output of the wind turbine. Two software, GAMBIT and FLUENT, are used in this work; GAMBIT is used to create modeling and meshing of the airfoils while FLUENT is used to simulate and analysis the airfoils. The analysis showed that the significant enhancement in aerodynamic performance for TCB6612 is occurred. It is found that value of Cd/Cl is decreased about 10.23%, the power coefficient is reached to 51.9%, and the power output is increased about 9.8%.

تعرض هذه الورقة التحليل العددي لمطيار جديد (TCB6612) ومقارنته مع مطيار قياسي (NACA4412) واستعمالهما في ريشة عنفة هوائية. الهدف الرئيسي من هذا العمل العمل هو تحسين الاداء الحركي الهوائي للمطيار وذلك من خلال تغيير الشكل الهندسي للمطيار من اجل زيادة الطاقة الاجمالية لعنفات الرياح. لانجاز هذا العمل تم استخدام برنامج كامبتGAMBIT و برنامج فلونت FLUENT، حيث استخدم برنامج كامبت لتكوين النمذجة للمطيار في حين استخدم برنامج الفلونت لمحاكات وتحليل المطيار. اظهر التحليل ان هناك تحسن كبير في الاداء الهوائي لـ TCB6612، حيث وجد ان قيمة Cd/Cl قد انخفضت حوالي 10.23%، ومعامل القدرة بلغ 51.9%، وزيادة في الطاقة المنتجة بنسبة 9.8%.


Article
Flow Separation Of Axial Compressor Cascade Blades

Authors: Sabah Faleh Habeeb --- Arkan Kh. Al-Taie
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2010 Volume: 16 Issue: 2 Pages: 4877 -4896
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

An experimental and theoretical investigation of the effect of flow separation on the performance of a cascade NACA 65_(12)10 axial compressor blade has been carried out. The experimental work includes the fabrication of three blades from wood, each having a chord (100mm) but one of these blades having a span of (90mm) for smoke tunnel testing and the other two blades having a span of (380mm) for wind tunnel testing.The two blades were connected by suitable mechanism in order to be fixed in the wind tunnel protractor and rotated in the required stagger angle. The cascade was tested in an open type low-speed subsonic (Mach number=0.117) wind tunnel, for Reynolds number (Re=239605) based on maximum velocity (35 m/s) and airfoil chord length. The total and static pressures were measured in selected points between the two blades for stagger angles of (4 , 0 ,-4 ,-8 and -120) by using a multi-tube manometer and a pitot static tube. The small blade (90mm span) is tested in the smoke tunnel to visualize the real behavior of flow separation. The theoretical work includes using the software FLUENT (V6.2) to simulate the flow between the two blades. The study shows that the flow separation begins when the cascade are inclined at a stagger angle of (-4) on the suction side of the lower blade at a position (96%chord experimentally and 98%chord theoretically). Then, the separation zone increases with increased stagger angle (in clockwise direction) and reach to the position (61%chord experimentally and 63%chord theoretically) at a stagger angle (-12 ).These results are validated by a smoke tunnel tests.This separation affects the performance of the compressor, where the static pressure ratio (pse /psi ) decreases as the separation zone gets bigger. The range of working stagger angle is then calculated. It was found in the range (-18 to 36 ). The flow behavior between the two blades shows that the blade-to-blade configuration works as nozzle-diffuser. The theoretical results were compared with the experimental results and good agreement was obtained.

تم في هذا البحث اجراء دراسة عملية ونظرية لتاثير انفصال الجريان على اداء الريشتين المتعاقبتين للضاغطة المحورية من نوع [NACA 65_ (12)10] . الجزء العملي يتضمن تصنيع ثلاث ريش من مادة الخشب, وتر كل ريشة (100ملم) لكن احدى الريش ذات عرض(90 ملم) لاختبارات النفق الدخاني والريشتين المتبقتين ذواتا عرض(380ملم)لاختبارات النفق الهوائي. تربط الريشتيين المستخدمتين لاختبارات النفق الهوائي بآليه مناسبة لكي تثتبت بمنقلة النفق وبالتالي يمكن تدويرها بالزاوية المطلوبة. تم اختبار متعاقبة الريشتين في نفق هوائي تحت صوتي واطى السرعة لعدد رينولد((Re=239605 المحسوب على اساس السرعة القصوى (35مثا) وطول وتر الريشة. لقد تم قياس الضغط الكلي والضغط الاستاتيكي للنقاط المختاره بين ريشتي الضاغطة لخمس زوايا أنحراف هي (4,0,4-,8- و12-) باستخدام مانوميترمتعدد الانابيب وأنبوب بيتوت-أستاتي. تم أختبار الريشة الصغيرة (ذات عرض90 ملم) بأستخدام النفق الدخاني لرؤية السلوك الحقيقي لأنفصال الجريان. الدراسة النظرية تتضمن استخدام البرنامج الجاهز ((FLUENT V6.2 لمحاكات الجريان بين الريشتين. أظهرت الدراسة بأن الأنفصال يبدأ عندما تكون زاوية الأنحراف (4-) حيث يحدث على السطح العلوي للريشة السفلى وبمسافة (96% من الوتر عمليا" و98 % من الوتر نظريا") من الدخول الى الخروج للمتعاقبة‘. وبعد ذلك تزداد منطقة الأنفصال بأزدياد زاوية الأنحراف(stagger angle)(بأتجاه عقرب الساعة) حتى تصل الى (61% من الوتر عمليا" و63% من الوتر نظريا") من الدخول الى الخروج عند زاوية أنحراف (12-) وهذا ما يوضحه أختبار النفق الدخاني. يؤثر الأنفصال على أداء الريشتين المتعاقبتين حيث تقل نسبة الضغط (الضغط الستاتيكي الخارج الى الضغط الستاتيكي الداخل) بأزدياد منطقة الانفصال. وبعد ذلك تم حساب المدى الشغال لزوايا الأنحراف . الذي وجد ضمن المدى (من-18 الى 36) . أن سلوك الجريان بين الريشتين يبين بأن الريشتين المتعاقبتين تعملان كبوق متقارب- متباعد. تمت مقارنة النتائج النظرية مع النتائج العملية وجد تقارب جيد بين تلك النتائج.


Article
Flow Separation Of Axial Compressor Cascade Blades

Authors: Sabah Faleh Habeeb --- Arkan Kh. Al-Taie
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2010 Volume: 16 Issue: 3 Pages: 5663- 5682
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

An experimental and theoretical investigation of the effect of flow separation on the performance of a cascade NACA 65_(12)10 axial compressor blade has been carried out. The experimental work includes the fabrication of three blades from wood, each having a chord (100mm) but one of these blades having a span of (90mm) for smoke tunnel testing and the other two blades having a span of (380mm) for wind tunnel testing.The two blades were connected by suitable mechanism in order to be fixed in the wind tunnel protractor and rotated in the required stagger angle. The cascade was tested in an open type low-speed subsonic (Mach number=0.117) wind tunnel, for Reynolds number (Re=239605) based on maximum velocity (35 m/s) and airfoil chord length. The total and static pressures were measured in selected points between the two blades for stagger angles of (4 , 0 ,-4 ,-8 and -120) by using a multi-tube manometer and a pitot static tube. The small blade (90mm span) is tested in the smoke tunnel to visualize the real behavior of flow separation. The theoretical work includes using the software FLUENT (V6.2) to simulate the flow between the two blades. The study shows that the flow separation begins when the cascade are inclined at a stagger angle of (-4 ) on the suction side of the lower blade at a position (96%chord experimentally and 98%chord theoretically). Then, the separation zone increases with increased stagger angle (in clockwise direction) and reach to the position (61%chord experimentally and 63%chord theoretically) at a stagger angle (-12 ).These results are validated by a smoke tunnel tests.This separation affects the performance of the compressor, where the static pressure ratio ( / ) decreases as the separation zone gets bigger. The range of working stagger angle is then calculated. It was found in the range (-18 to 36 ). The flow behavior between the two blades shows that the blade-to-blade configuration works as nozzle-diffuser. The theoretical results were compared with the experimental results and good agreement was obtained.

تم في هذا البحث اجراء دراسة عملية ونظرية لتاثير انفصال الجريان على اداء الريشتين المتعاقبتين للضاغطة المحورية من نوع [NACA 65_ (12)10] . الجزء العملي يتضمن تصنيع ثلاث ريش من مادة الخشب, وتر كل ريشة (100ملم) لكن احدى الريش ذات عرض(90 ملم) لاختبارات النفق الدخاني والريشتين المتبقتين ذواتا عرض(380ملم)لاختبارات النفق الهوائي. تربط الريشتيين المستخدمتين لاختبارات النفق الهوائي بآليه مناسبة لكي تثتبت بمنقلة النفق وبالتالي يمكن تدويرها بالزاوية المطلوبة. تم اختبار متعاقبة الريشتين في نفق هوائي تحت صوتي واطى السرعة لعدد رينولد((Re=239605 المحسوب على اساس السرعة القصوى (35مثا) وطول وتر الريشة. لقد تم قياس الضغط الكلي والضغط الاستاتيكي للنقاط المختاره بين ريشتي الضاغطة لخمس زوايا أنحراف هي (4,0,4-,8- و12-) باستخدام مانوميترمتعدد الانابيب وأنبوب بيتوت-أستاتي. تم أختبار الريشة الصغيرة (ذات عرض90 ملم) بأستخدام النفق الدخاني لرؤية السلوك الحقيقي لأنفصال الجريان. الدراسة النظرية تتضمن استخدام البرنامج الجاهز ((FLUENT V6.2 لمحاكات الجريان بين الريشتين. أظهرت الدراسة بأن الأنفصال يبدأ عندما تكون زاوية الأنحراف (4-) حيث يحدث على السطح العلوي للريشة السفلى وبمسافة (96% من الوتر عمليا" و98 % من الوتر نظريا") من الدخول الى الخروج للمتعاقبة‘. وبعد ذلك تزداد منطقة الأنفصال بأزدياد زاوية الأنحراف(stagger angle)(بأتجاه عقرب الساعة) حتى تصل الى (61% من الوتر عمليا" و63% من الوتر نظريا") من الدخول الى الخروج عند زاوية أنحراف (12-) وهذا ما يوضحه أختبار النفق الدخاني. يؤثر الأنفصال على أداء الريشتين المتعاقبتين حيث تقل نسبة الضغط (الضغط الستاتيكي الخارج الى الضغط الستاتيكي الداخل) بأزدياد منطقة الانفصال. وبعد ذلك تم حساب المدى الشغال لزوايا الأنحراف . الذي وجد ضمن المدى (من-18 الى 36) . أن سلوك الجريان بين الريشتين يبين بأن الريشتين المتعاقبتين تعملان كبوق متقارب- متباعد. تمت مقارنة النتائج النظرية مع النتائج العملية وجد تقارب جيد بين تلك النتائج.


Article
EXPERIMENTAL STUDY AND CFD SIMULATION OF TWO - PHASE FLOW (WATER – SOLID) IN FLUIDIZED BED COLUMN
دراسة عملية ومحاكاة لأبراج التمييع ثنائية الطور ( ماء- صلب)

Author: Dr. Riyadh S. Al-Turaihi Sarah Hassan Oleiwi
Journal: Iraqi journal of mechanical and material engineering المجلة العراقية للهندسة الميكانيكية وهندسة المواد ISSN: 20761819 Year: 2016 Volume: 16 Issue: 3 Pages: 297-314
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

The static pressure of two phase ( liquid - Solid ) fluidized bed was investigated experimentally in this work for different values of the ratio static bed height over the diameter of the bed column (H/D) (0.59, 0.98, 1.38) and liquid phase velocity (0.16, 0.49, 0.82 m/s). As well as the expansion of the bed visualized experimentally has compared with the solid volume fraction found numerically. The fluidized system consists of glass test pipe of 1m height and 0.0254 m diameter inserted with stainless steel particles of 1.5 mm diameter fluidized by water. Pressure was measured by pressure sensor located at four tapes on the side of the fluidized bed pipe. High speed camera was used to photograph the flow in the test pipe. The experimental results compared with computational fluid dynamics model simulated by ANSYS FLUENT version 15.0. The results were in a good agreement with the experimental data.

تم دراسة الضغط في أبراج التمييع ثنائية الطور (سائل - صلب) عمليا في هذا البحث لكميات مختلفة من نسبة ارتفاع المادة الصلبة إلى قطر الأنبوب المستخدم للتمييع (H/D) (0.59, 0.98, 1.38) و سرعه الطور السائل (0.16, 0.49, 0.82 m/s). كذلك تمت مشاهده ارتفاع المادة الصلبة داخل الانبوب عمليا ومقارنتها مع النتائج النظرية للكسر الحجمي للمادة الصلب. النظام المستخدم للتمييع يتكون من انبوب شفاف بارتفاع ام و قطر 0.0254 م وبداخله حبيبات من مادة الفولاذ المقاوم للصدأ بقطر 1.5ملم والتي تم تمييعها باستخدام الماء. تم استخدام أربع متحسسات لقياس الضغط على طول انبوب التمييع. استخدمت كاميرا تصوير ذات سرعه عالية لتصوير الجريان داخل الأنبوب. تمت مقارنة النتائج العملية مع نتائج الموديل الرياضي ووجدت في حالة تطابق جيد ..


Article
NUMERICAL INVESTIGATION OF HEAT TRANSFER ON LAMINAR FLOW IN CIRCULAR TUBE FITTED WITH CONICAL SPRING INSERTS AND NANOTECHNOLOGY

Authors: Qasim Saleh Mahdi --- Ali Shokor Golam
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2018 Volume: 22 Issue: 2 (Part-2) Pages: 146-160
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Numerical investigation have been worked to study the process of heat transfer by using laminar forced convection of nanofluid, using the water as a basefluid and Alumina (Al2O3) as nanoparticles in a three dimensional tube fitted with conical spring inserts under a constant heat flux. A Solid Works Software2012 is used to draw the geometries of heat exchanger in plain tube. Dimensions of 100cm, 2.2cm and 2.4 cm represent the straight copper tube length, inner diameter and outer diameter respectively. The conical spring inserts of 16mm-6mm coil diameter, 15cm length, pitch of 20mm and 4mm wire diameter. Those inserts were arranged into eight types. To predict the pressure of flow, heat transfer of heat exchanger and temperature distribution, numbers of governing equations under assumptions were utilized, such as energy equations, momentum and continuity. To get all of the computational results, commercial ANSYS Fluent copy package 14.0 with the assistance of solid works and Gambit software program along with the finite volume approach is used. Under constant heat flux, a constant heat flux of 10000 W/ m2 and constant Reynolds’ number of 2000, heat exchanger performance are investigated under the effect of different parameters. Including arrangement of conical spring inserts (A1 to A8) and volume consternation of nanoparticles (0.1%, 0.2%, and 0.3%).Significant improvement in the water heating process shown with the use of conical spring insert, indicating the enhancement of heat transfer between the water and hot tube surface.(A5) arrangement is the best type as shown in this study due to the increase in water temperature. Also, results show that the heat transfer is increases by using nanofluid and conical spring inserts together.


Article
Experimental and Numerical Study on Cavitation Effects in Centrifugal Pumps
دراسـة عملية و عددية حـول تـأثيـر ظاهرة التكهف فـي المضخات النابذة

Authors: Ali Abdul Mohsin Hassan علي عبد المحسن حسن --- Nabeel Ahmed Kamal نبيل أحمد كمال
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2014 Volume: 20 Issue: 2 Pages: 73-86
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Experimental and numerical investigations of the centrifugal pump performance at non-cavitating and cavitating flow conditions were carried out in the present study. Experiments were performed by applying a vacuum to a closed-loop system to investigate the effects of the net positive suction head available (NPSHa), flow rate, water temperature and pump speed on the centrifugal pump performance. Accordingly, many of the important parameters concerning cavitation phenomenon were calculated. Also, the noise which is accompanied by cavitation was measured. Numerical analysis was implemented for two phase flow (the water and its vapor) using a 2-D simulation by ANSYS FLUENT software to investigate the internal flow of centrifugal pump under cavitating conditions. It was observed that with decreasing NPSHa, the values of the pump head, flow rate and efficiency initially remain constant, but with further reduction in NPSHa these parameters will decrease. Also, it was found that at 3% head drop the percentage drop of the flow rate is less than 2% whereas the percentage drop of the efficiency is greater than 3%. Numerically, it was noticed that the cavitation regions appear at the leading edge of suction side of the impeller blades which represents the lowest pressure area inside the computational domain of the centrifugal pump.

يتناول هذا البحث دراسة عملية وعددية لإداء مضخة نابذة عند ظروف الجريان غير المتكهف والمتكهف. التجارب العملية أجريت بطريقة تقليل الضغط الداخل الى المضخة بواسطة منظومة تفريغ الهواء، حيث تم دراسة تأثير تغيير قيم رفع السحب الصافي الموجب المتوفر (NPSHa) و معدل الجريان الحجمي و درجة حرارة الماء وسرعة المضخة على اداء المضخة النابذة وعليه عدة متغيرات مهمة تخص ظاهرة التكهف تم أحتسابها، وكذلك تم قياس مستوى الضوضاء المصاحبة لظاهرة التكهف. التحليل العددي لهذه الدراسة تضمن إجراء محاكاة ثنائية الأبعاد للجريان ثنائي الطور (للماء وبخاره) باستخدام حقيبة (ANSYS FLUENT) لتحري ظروف الجريان المتكهف داخل المضخة النابذة. النتائج العملية أظهرت أنه عند تقليل قيمة (NPSHa) فإن قيم رفع المضخة ومعدل الجريان والكفاءة تبقى ثابتة بشكل أولي، ولكن مع أستمرار تقليل قيمة (NPSHa) فإن هذه القيم سوف تنخفض. كذلك لوحظ أنه عند هبوط رفع المضخة بنسبة 3% فأن نسبة هبوط معدل الجريان تكون أقل من 2% في حين أن نسبة هبوط الكفاءة تكون أكثر من 3%. المحاكاة العددية أظهرت أن مناطق التكهف تظهر عند الحافات الأمامية لريش البشارة من جهة السحب حيث أنها تتشكل في المساحة الأقل ضغطا داخل المضخة.


Article
Experimental and Numerical Investigation of Four- Phase Flow (Water–Gasoline-Air-Solid) in a Fluidized Bed Column

Author: Riyadh S. Al-Turaihi
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2016 Volume: 24 Issue: 1 Pages: 164-182
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

In this paper four phase fluidized bed is experimentally built and numerically modeled to study the bed characteristics such as ratio (the static bed height of solid particle / the bed diameter (H/D)), air, gasoline , and water superficial velocity. The test pipe for the experimental rig is Perspex pipe with 1 m long and 0.0254 m diameter. The 2D numerical model has been established with Ansys fluent 15.0. Pressure drop equation is found to relate the pressure drop with the bed parameters with deviation of 22%. The Four-phases was represented by air, water, gasoline and solid particle. The results show that the pressure of the bed increases as the ratio H/D increases and air, gasoline , and water superficial velocity increases. As well as the expansion of the bed increases as air, gasoline, and water superficial velocity increases.

في هذا البحث تمت دراسة خواص أنبوب التمييع رباعي الطور (نسبة ارتفاع الماده الصلبه / قطر الانبوب (H/D), سرعه الهواء والماء والكازولين) من خلال بناء أنبوب تمييع رباعي الطور عمليا و بناء نموذج نظريا. الأنبوب المستخدم عمليا من مادة (Perspex) بطول 1م وقطر 0.0254 م. تم أنشاء نموذج نظري ثنائي الأبعاد باستخدام برنامج (Ansys fluent 15.0). كذألك تم إيجاد معادلة تجريبيه لحساب فرق الضغط للأنبوب بالاعتماد على خواص الأنبوب وبنسبة حيود 22 %. الاطوار المستخدمه هي الهواء والماء والكازولين والحبيبات الصلبه. بينت النتائج بان ضغط الأنبوب يزداد بزيادة النسبة (H/D) وسرعة الهواء والكازولين والماء. بالإضافة إلى ذلك فان ارتفاع المادة الصلبة داخل الأنبوب يزداد بزيادة سرعة الهواء والكازولين والماء.


Article
A Numerical simulation of emissions of pollutants from industrial chimney

Authors: Saleh I. Najim --- Qais A. Rishack --- Alaa H. Mohammed
Journal: Basrah Journal for Engineering Science مجلة البصرة للعلوم الهندسية ISSN: Print: 18146120; Online: 23118385 Year: 2014 Volume: 14 Issue: 2 Pages: 1-12
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

The prediction of the concentration fields of pollutants released to the atmosphere is a key factor in assessing possible environmental damages caused by industrial emissions. To solve the concentration equation for gaseous or particulate effluents it is necessary to know as accurately as possible the velocity field and turbulence intensities at the atmospheric boundary layer in the region of interest. A two dimensional mathematical model based on the equations of fluid mechanics along with a modified non-isotropic k-ε turbulence model are employed to calculate the flow and dispersion at the atmospheric micro scale (distances of the order of kilometers).Results of investigation are obtained by using the finite volume method (FVM) to solve the average Navier Stock equations coupling with turbulent k- ε model. The calculation was carried out for plume flow from the industrial chimney with different plume velocities, wind velocities and heights of stack. The equations of model are solved with SIMPLE schemes.FLUENT program used to show the results of the plume flow at the variable parameters of wind and plume velocities and heights of stack, the code is applied to simulate several cases of flow and dispersion. Comparisons against experimental results show that the non-isotropic turbulence model has better ability to foresee the plume dispersion than the standard k- ε, in which the non-isotropic character of turbulence is relevant. The computational results show that the plume path and concentrations are correctly predicted by the numerical model

Listing 1 - 10 of 21 << page
of 3
>>
Sort by
Narrow your search

Resource type

article (21)


Language

English (17)

Arabic and English (3)

Arabic (1)


Year
From To Submit

2018 (6)

2017 (4)

2016 (2)

2014 (5)

2010 (4)