research centers


Search results: Found 5

Listing 1 - 5 of 5
Sort by

Article
Quantitative Determination of Paracetamol in Pharmaceutical Formulations by FTIR Spectroscopy
التقدير الكمي للباراسيتامول في المستحضرات الصيدلانية بواسطة مطيافية الاشعة تحت الحمراء FTIR

Author: Bashar Hussein Qasim
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2010 Volume: 28 Issue: 15 Pages: 5028-5035
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The aim of this work was to use a spectrophotometric method for thedetermination of paracetamol in pharmaceutical formulations.The quantification of paracetamol through infrared spectroscopy was developed and validated for pharmaceuticals in tablet forms. The method involves the extraction of the active ingredient with chloroform and the measurement of the area of the infrared band corresponding to the carbonyl group centered at 1650cm-1. The specificity,linearity,detection limits,precision and accuracy of the calibration curve, paracetamol extraction, infrared analysis and data manipulation were determined in order to validate the method. The statistical results were compared with the quantification of paracetamol through UVdetection.The recovery values obtained in the analysis of pharmaceuticals are within the range 98-105%.

تم في البحث الحالي استخدام طريقة طيفية (مطيافية الاشعة تحت الحمراء المعززة لتقدير الباراسيتامول المتواجد بشكل حبوب تقديرا كمياً. تتضمن ( FTIR بتحويلات فورير الطريقة استخلاص المادة الفعالة للباراستامول بوساطة المذيب العضوي الكلوروفورم، ومن ثم تحضير محاليل قياسية للباراسيتامول وقياسها بواسطة جهاز مطيافية الاشعة تحت ثم حساب مساحة الحزمة العائدة الى مجموعة الكاربونيل والواقعة في المدى FTIR الحمراء FTIR التي يسجلها جهازالاشعة تحت الحمراء (T%) 1650 سم- 1، تم تحويل قيمة النفاذيةوذلك لغرض رسم منحني المعايرة القياسي للمحاليل القياسية المقاسة (A) الى قيمة الامتصاصية بواسطة جهاز الاشعة تحت الحمراء. تم معالجة القيم المستحصلة من القياسات احصائياً وتقييم كل من الخطية ، حدود الكشف، الدقة لمنحني المعايرة القياسي ،كذلك تقييم استخلاص المادة الفعالة للباراسيتامول بواسطة المذيب، ومن ثم مقارنة هذه النتائج الاحصائية مع النتائج المستحصلة من التقدير الكمي للباراسيتامول بواسطة مطيافية الاشعة فوق البنفسجية . كانت قيمة . % 105 – الاستردادية للباراسيتامول تتراوح بين 98


Article
Estimation of Gypsum- Calcite Percentages Using a Fourier Transform Infrared Spectrophotometer (FTIR), in Alexandria Gypsiferous Soil -Iraq
تقدير تراكيز الجبسوم والكالسايت باستخدام جهاز طيف الاشعة تحت الحمراء(FTIR) للترب الجبسية في الاسكندرية – العراق

Authors: Moutaz Al Dabbas معتز الدباس --- Mohammed Y. Eisa محمد يعقوب عيسى --- Weam H. Kadhim وئام حسن كاظم
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2014 Volume: 55 Issue: 4B Pages: 1916-1926
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this study the Fourier Transform Infrared Spectrophotometry (FTIR) provides a quick, efficient and relatively inexpensive method for identifying and quantifying gypsum concentrations in the samples taken from different sites from different localities from Alexandria district southwest Baghdad. A comprehensive spectroscopic study of gypsum-calcite system was reported to give good results for the first time by using IR for analytical grades of gypsum (CaSO4.2H2O) and calcite (CaCO3) pure crystals. The spectral results were used to create a calibration curve relates the two minerals concentrations to the intensity (peaks) of FTIR absorbance and applies this calibration to specify gypsum and calcite concentrations in Iraqi gypsiferous soil samples, which were collected from different quarries at Alexandria district-Babylon Governorate , southwest of Baghdad city. The peaks were assigned to the fundamental vibrational modes of (SO4)-2 in gypsum and (CO3)-2 in calcite. Thus FTIR appears to provide fast and reliable method for identifying gypsum and calcite concentrations in the gypsiferous soils or any sediments or rocks that have different concentrations of these two minerals.

ثبت في هذه الدراسة أن استخدام جهاز طيف الأشعة تحت الحمراء (FTIR) يوفر طريقة سريعة وفعالة وغير مكلفة نسبيا لتحديد وقياس تراكيز الجبسوم والكالسايت لعينات أخذت من مواقع مختلفة في منطقة الاسكندرية جنوب غرب بغداد. وقد أفادت الدراسة الطيفية الشاملة لنظام بلورات الجبسوم - الكالسيت النقية في أطياف الأشعة باستخدام جهاز تحت الحمراء ولاول مرة بانها اعطت نتائج جيدة للنظم التحليلية لبلورات الجبسوم (CaSO4.2H2O) والكالسيت (كربونات الكالسيوم CaCO3) النقية . ثم باستخدام نتائج أطياف هذين المعدنين النقيين تم التوصل إلى إنشاء منحنى المعايرة الذي يشير الى تراكيز المعدنين من خلال شدة التراكيز الظاهرة من ارتفاع قمم منحنى FTIR الامتصاصية وتنطبق هذة المعايرة لتحديد تراكيز الجبسوم والكالسايت في عينات جمعت من الترب الجبسية التي اخذت من مقالع مختلفة من منطقة الإسكندرية في محافظة بابل إلى الجنوب الغربي من مدينة بغداد . ومن خلال مطابقة قمم النماذج المجهولة التراكيز من الترب الجبسية التي تحتوي على المعدنين وبنسب مختلفة وشدتها (اي ارتفاع قمة منحنيات كل معدن) ومقارنتها بالمنحنى القياسي تم تعيين تراكيز الجبسوم والكالسيت في الترب الجبسية. وبالتالي فان FTIR يمكن ان يعطي وسيلة سريعة وموثوق بها لتحديد تراكيز الجبسوم والكالسايت في الترب الجبسية او اية رواسب او صخور لهذين المعدنين.


Article
Mechanical evaluation of nano hydroxyapatite, chitosan and collagen composite coating compared with nano hydroxyapatite coating on commercially pure titanium dental implants

Authors: Sabreen W. Ibrahim --- Widad A. Al Nakkash
Journal: Journal of baghdad college of dentistry مجلة كلية طب الاسنان بغداد ISSN: 16800087 Year: 2017 Volume: 29 Issue: 2 Pages: 42-48
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Background: Dental implants act as infrastructure for fixed restoration to look like as a natural tooth.Osseointegration is a biological events and considered as a base for success of dental implant. The aim of this studyis to evaluate the bond strength between bone and Ti implant coated with mixture of nano hydroxyapatite-chitosancollagencompared with Ti implants coated with nano hydroxyapatite implanted in rabbit tibia, after different periodof implantation time (two and six weeks) by torque removal test.Material and methods: 36 screws of commercially pure titanium; 8mm in length and 3mm diameter , 18 screwscoated with mixture of nano hydroxyapatite-chitosan-collagen and18 screws coated with nano hydroxyapatite bydip coating. Structural characteristics was assessed by scanning electron microscope, and FTIR analysis. The screwswere implanted in 18 healthy adult male New Zeeland rabbits each tibia received one screw, right tibia receivedscrew coated with nano hydroxyapatite while left tibia received screw coated nano hydroxyapatite-chitosancollagencomposite. Removal torque test was done by torque meter to determine the highest torque valuenecessary to remove the implants from tibia bone after different period of time of implantation(2 and 6 weeks).Result: Nano hydroxyapatite-chitosan-collagen composite coating was resulting in higher torque removal value thannano hydroxyapatite coating for two periods of time.Conclusion: Concluded that addition of collagen and chitosan to nano hydroxyapatite was more efficient in rapidbone formation than nano hydroxyapatite only


Article
EXCESS MOLAR VOLUMES, SURFACE TENSIONS,VISCOCITY DEVIATION AND FTIR SPECTROSCOPY OF 1-BUTANOL-ETHYL ACETATE BINARY SYSTEM MIXTURE

Author: Mustafa J. Nuhma
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2017 Volume: 10 Issue: 4 Pages: 643-653
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

The physical properties (viscosity, surface tension and density) were computed in laboratory using different laboratory equipment for binary and pure system at (P=1 atm and T=25C). At mole fraction 0.5, the excess volume was found to be positive value while the deviation in viscosity and surface tension was found as negative values at the same mole fraction. Experimental excess properties were compared using Redlich-Kister equation and showed acceptable standard deviation. The inter molecular interaction of the 1-Butanol and Ethyl acetate found to be negligible and the vulnerability of the hydrogen bonds according to the FTIR spectra to a mixture of 1-Butanol and Ethyl acetate is consistent with the positive values of excess volume. Overlying the values of surface tension and the deviation in viscosity was found as negative values for all mole fractions studied.


Article
Excess Thermodynamic Properties and Ftir Spectroscopy of Aceton-Isopropanol Liquid Binary Mixture

Authors: Ali A. Jazie --- Mustafa J. Nuhma
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2018 Volume: 26 Issue: 2 Pages: 97-105
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

Experimental investigation was done using different instruments for the testing the properties of density, surface tension and viscosity in the case of pure and mixture system at the normal temperature of 25 oC and 1 atm. Excess volume was found to exhibit negative value at a mole fraction of 0.5. The deviation in the surface tension and viscosity were found of a positive value at the mole fraction value of 0.5. The experimental excess properties were correlated using the Redlich-Kister (RK) equation and showed an accepted standard deviation. The intermolecular interaction between acetone and isopropanol was found of negligible effect and showed a weakness in the hydrogen bonding according to the FTIR spectra for the mixture of acetone and isopropanol which agreed with the positive values of excess molar volume. Moreover, the values of surface tension and viscosity deviations were found of negative values for all the mole fraction range studied.

تمت الدراسه العمليه باستخدام اجهزه مختلفه لاختبار خواص الكثافه والشد السطحي واللزوجه للمكونات النقيه للسائل المدروس وكذلك للسائل الثنائي التركيب من الاسيتون والايزوبروبانول عند درجة حرارة 25 درجه مئويه وضغط جوي مقداره 1 ضغط جوي. لقد وجد ان قيمة الحجم المولي هي قيمة سالبه عند الكسر المولي الذي مقداره 0,5. بينما تم ايجاد قيم الانحراف في الشد السطحي والانحراف في اللزوجه عند الكسر المولي 0,5 وكانت قيم موجبه. تم ربط الخواص العمليه الزائديه بعضها مع البعض الاخر باستخدام معادلة ردلج كيستر وقد كانت النتائج ذات انحراف معياري مقبول. بواسطة تحليل المطياف الضوئي فقد تبين ان الترابط الجزيئي الداخلي لمكونات السائل الثنائي التركيب (من الاسيتون والايزوبروبانول) مهمول التاثير وايضا من خلال تحليل المطياف الضوئي لهذا المزيج فقد تبين الضعف في الاواصر الهيدروجينيه وهذا يتفق مع الحجم المولي الزائد.من ناحية اخرى فان قيم الشد السطحي وقيم الانحرافات في الشد السطحي و اللزوجه هي قيم سالبه لجميع الكسور الموليه المدروسه.

Listing 1 - 5 of 5
Sort by
Narrow your search

Resource type

article (5)


Language

English (5)


Year
From To Submit

2018 (1)

2017 (2)

2014 (1)

2010 (1)