research centers


Search results: Found 39

Listing 1 - 10 of 39 << page
of 4
>>
Sort by

Article
A new mode for an on-line determination of Amiloride in pure and pharmaceutical preparation using CFIA with homemade Ayah 3SBGRx3- 3D solar cell microphtometer analyzer
نمط جديد للتقدير الأني للأميلورايد في المستحضرات الصيدلانية والنقية بأستخدام التحليل بالحقن الجرياني المستمر عن طريق استخدام محلل طيفي مايكروي مصنع محليا Ayah 3SBGR x3-3D solar cell.

Authors: Malik H. Alaloosh Alamri مالك حسين العلوش العامري --- Nagam S. TurkieAl-Awadie نغم شاكر تركي العوادي
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2014 Volume: 55 Issue: 3B Pages: 1137-1152
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A new, simple, accurate, fast and sensitive spectrophotometric method has been developed for the analysis of amiloride in pure and pharmaceutical formulations by continuous flow injection analysis. The method was based on the oxidation of the drug with Ce(IV)sulfate in acidic medium to formed a pinkish-red color species which determined using homemade Ayah 3SBGR x3-3D solar cell flow injection photometer. Optimum conditions were obtained using a high intensity green light emitted diode as a source. The linear dynamic range for the instrument response versus amiloride concentration was 0.0005- 10 mmol.L-1 while the L.O.D was of 9.471 ng / sample. The correlation coefficient (r) was 0.9824 while percentage linearity (r2%) was 96.50%. RSD% for the repeatability (n=8) was lower than 1.5% for the determination of amiloride, at concentration of 0.5 mmol.L-1. The method was applied successfully for the determination of amiloride in pharmaceutical preparation. A comparison was made between the newly developed method and the classical method (UV-Vis spectrophotometry at wave length 540nm) of analysis using the standard additions method via the use of paired t-test. It showed that there was no significant difference between the quoted value of each individual company with calculated t-value at 95% confidence interval from developed method, in addition to comparison between two methods and calculate t-value, it was noticed that there no significant difference between two methods at 99% but a significant difference at 95% confidence level.

طورت طريقة طيفية جديدة, بسيطة, سريعة, مظبوطة, وحساسة لتحليل الاميلورايد في صيغته النقية والمستحضرات الصيدلانية بأستخدام التحليل بالحقن الجرياني المستمر. استندت الطريقة على اكسدة العقار بكبريتات السيريوم (VI) في الوسط الحامضي لتكوين اصناف ملونة وردي- محمر والتي قدرت بأستخدام مطياف الحقن الجرياني مع Ayah 3SBGR x3-3D solar cell المصنع محليا. تم دراسة الظروف الفضلى التي تم التوصل اليها بأستخدام ثنائي الوصلة باعث للضوء الاخضر وبشدة عالية كمصدر للتشعيع. كان المدى الخطي الفعال لعلاقة تغير الاستجابة الألية مع تركيز الاميلورايد 0.0005 - 10 مللي مول.لتر-1 بينما حدود الكشف 9.471 نانوغم / انموذج. وان معامل الارتباط (r) 0.9824 بينما نسبة الخطية r2 % = 96.50 % . الانحراف القياسي النسبي المؤي (RSD%) للتكرارية اقل من 1.5 % لمحلول الاميلورايد بتركيز 0.5 مللي مول .لتر-1 (8=n) طبقت الطريقة بنجاح لتقدير الاميلورايد في المستحضرات الصيدلانية . اجريت مقارنة بين الطريقة المطورة والطريقة التقليدية (مطيافية UV-Vis) عند طول موجي 540 نانو متر للتحليل باستخدام منحني الاضافات القياس من خلال استخدام اختبار t- المزدوج. تبين انه لايوجد فرق جوهري بين القيمة الرسمية وقيمة t- المحسوبة من الطريقة المطورة عند فاصل ثقة 95% بالاضافة الى اجراء مقارنة بين الطريقتين وحساب قيمة t- ولوحظ انه لايوجد فرق جوهري بين الطريقتين عند مستوى قناعة 99% وفرق جوهري عند مستوى قناعة 95%.


Article
Determination of phosphate levels in the southern part of Al-Hammar marsh water by flow injection analysis.
قياس مستويات الفوسفات في مياه الجزء الجنوبي لهور الحمّار بتحليل الحقن الجرياني.

Authors: K.H. Al-Sowdani كامل حسين السوداني --- Y.S. Al-Jorany يوسف شافي جبر الجوراني
Journal: Mesopotamian Journal of Marine Science مجلة وادي الرافدين لعلوم البحار ISSN: 18152058 Year: 2010 Volume: 25 Issue: 1 Pages: 99-109
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

Abstract - Flow Injection Analysis (FIA) was applied to determine phosphate concentration in water of the southern part of Al-Hammar marsh water from July 2007 to July 2008. A linear line was obtained over the range 0.25- 1.75 μg/ml of phosphate with regression coefficient for seven points is 0.9999. The detection limit was 0.075 μg/ml with % R.S.D for ten replicate analysis of 1.0 μg/ml phosphate is 0.511% and the dispersion coefficient in the flow system is 5.4. The samples can be analyzed at rates exceeding 72 sample per hour .It was noted that phosphate concentration ranged 0.295 - 1.450 μg/ml, whereas the maximum phosphate concentration was recorded in spring 2008 and the minimum in autumn 2008.

المستخلص تم تطبيق تقنية الحقن الجرياني (FI) لتقدير الفوسفات في مياه الجزء الجنوبي لهور الحمّار للفترة من تموز- 2007 ولغاية تموز- 2008. وكانت العلاقة الخطية ضمن المدى 0.25 -1.75 µg/ml بمعامل ارتباط 0.9999 وأن حد الكشف (2×noise) 0.075 µg/ml ومعامل الأنحراف القياسي النسبي r.s.d% لعشر قراءات من 1.0 µg/ml فوسفات يساوي 0.511% وكان معامل التخفيف لنظام الجريان 5.4 وأن سرعة النمذجة 72 sample/h وتراوحت تراكيز الفوسفات بـين 0.295- 1.450 µg/ml لمناطق الدراسة المختلفة . وسجلت أعلى القيم خلال فصل الربيع 2008 وأقلها خلال فصل الخريف 2008.


Article
New Developed Analytical-Chemiluminometric (Sensitized) Continuous Flow Injection Analysis, for Determination of Ciprofloxacin; Application to Pharmaceutical Preparation

Authors: Issam M.A. Shakir Al-Hashimi --- Nagam Shakir Turkie Al-Awadi
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2012 Volume: 15 Issue: 4 Pages: 11-21
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

A newly developed analytical method characterised by its speed and sensitivity for the determination of ciprofloxacin via the improvement of the chemiluminescence system for luminol-H2O2-OH--ciprofloxacin via continuous flow injection analysis. The method is based on the indirect chemiluminescence-reaction (Sensitized) via the improvement of the amount of photons released through the oxidation of luminol-H2O2-OH- in the presence of ciprofloxacin as a sensitizer for the reaction. Linear dynamic range for the chemiluminescence-emission vs. ciprofloxacin concentration was 0.01-1 mmol.L-1 while C.O.D was 96.64%. The L.O.Q was 203 ng/sample. L.O.D. (S/N=3) = 6.01ng/sample from the stepwise dilution for the minimum concentration of lowest concentration in the linear dynamic ranged of the calibration graph. R.S.D.% for n=10 was <1% for ciprofloxacin with concentration of 0.5 mmol.L-1. the method was applied successfully for the determination of ciprofloxacin in four pharmaceutical drugs. Using paired t-test it was shown that there were no significant difference between the two methods and on that basis the new method can be accepted as an alternative analytical method

تم تطوير طريقة تحليلية سريعة وحساسة لتقدير سايبروفلوكساسين بوساطة تحسين البريق الكيميائي لنظام: لومينال- بيروكسيد الهيدروجين- هيدروكسيد الصوديوم-سايبروفلوكساسين وباستخدام منظومة الحقن الجرياني. استندت الطريقة على تفاعل البريق الكيميائي غير المباشر (التحسسي) بفعل تحسين كمية الضوء المنبعث من اكسدة اللومينال ببيروكسيد الهيدروجين في وسط قاعدي بوجود سايبروفلوكساسين كمتحسس الى التفاعل. تم الحصول على علاقة لتغير استجابة البريق مع التركيز للسايبروفلوكساسين باستخدام معادلة الخط المستقيم وكان مدى منحني المعايرة (0.01-1) مللي مول.لتر-1 ومعامل التقدير (C.O.D) (%r2 = 96.64%)، اما حد التقدير الكمي (L.O.Q) 203 نانوغرام/83 مايكرولتر وبحد كشف (S/N=3) 16.01 نانوغرام/83 مايكرولتر من التخفيف التدريجي لاقل تركيز في منحني المعايرة. الانحراف القياسي النسبي المئوي (%R.S.D وn=10) < 1% لمحلول سايبروفلوكساسين بتركيز 0.5 مللي مول.لتر-1. طبقت الطريقة لتقدير سايبروفلوكساسين في اربع نماذج من المستحضرات الصيدلانية. اجريت مقارنة بين الطريقة المستحدثة (البريق الكيميائي التحسسي-الحقن الجرياني) والطريقة التقليدية للقياس الطيفي باستخدام نتائج منحني الاضافات القياسية وذلك باخضاعها الى اختبار t- المزدوج وتبين انه لا يوجد فرق جوهري بين الطريقتين وبالامكان استخدام نظام البريق الكيميائي: لومينال-H2O2--OH-سايبروفلوكساسين كبديل للطريقة التقليدية.


Article
Continuous Flow Injection Analysis for The Photometric Determination of Metformin Drug Via The Release of Copper(II) ion from Charged Gel Bead Crystal
التحليل الفوتومتري بالحقن الجرياني المستمر لعقار الميتافورمين من خلال تحرير ايون النحاس ( II ) من بلورة حبة الجيل المشحونة

Authors: Nagam S.Turkey Al-Awadi نغم شاكر تركي العوادي --- Issam M.A. Shakir عصام محمد علي شاكر
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2013 Volume: 54 Issue: 1 Pages: 17-26
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A newly developed analytical method characterized by its speed and sensitivity for the determination of metformin-HCl via the formation of complex for metformin-HCl-OH--copper(II) ion from the gel bead system by continuous flow injection analysis. The method is based on the imbedded copper(II) ion in the gel bead structure can be used in the reaction for the formation of red –magneta colour complex(λmax. =530nm) formed by direct reaction of the drug with the released copper (II) ion from the gel bead in alkaline medium. Linear dynamic range for the absorbance versus metformin concentration was 0.001-1 mmol.L-1 while C.O.D was (r2% =95.33%) . The L.O.Q was 0.868mmol.L-1.L.O.D (S/N=3)=0.5µmol.L-1 from the step wise dilution for the minimum concentration of lowest concentration in the linear dynamic ranged of the calibration graph with R.S.D% lower than 0.5% for 0.01 mmol.L -1( n=8) concentration of metformin- HCl, throughput 30 sample.hr-1. The method was applied successfully for the determination of metformin in three pharmaceutical drugs. A comparison was made between the newly developed method of analysis with the classical method(Uv-spectrophotometry at wave length = 241nm) of analysis using the standard addition method via the use of paired t-test. It shows that there was no significant difference at α= 0.05 (95% confidence) between the two methods. Therefore the newly developed method(using the Metformin- OH- - Cu(II) entrapped inside gel bead) can be adopted as an alternative method for the analysis of metformin.

تم تطوير طريقة تحليلية سريعة وحساسة لتقدير الميتافورمين بوساطة تكوين معقد لنظام :- ميتافورمين-هيدروكسيد الصوديوم –ايون النحاس(II) المحتوى داخل حبة الجيل وباستخدام منظومة الحقن الجرياني. استندت الطريقة على تكوين معقد بين ايون النحاس المزاح من حبة الجيل والعقار الميتافورمين في وسط قاعدي وبلون عنابي محمر والذي يمتص عند 530 نانومتر. تم الحصول على علاقة لتغير الممتصية مع التركيز للميتافورمين باستخدام معادلة الخط المستقيم وكان مدى منحني المعايرة (0.001-1) مللي مول.لتر-1 ومعامل التقدير (C.O.D) (%r2= 95.33%), اما حد التقدير الكمي (L.O.Q) 0.868 مللي مول . لتر-1 وبحد كشف (S/N=3) 0.5 مايكرو مول.لتر- 1 من التخفيف التدريجي لاقل تركيز في منحني المعايرة والانحراف القياسي النسبي المئوي اقل من 0.5% لتركيز 0.01 مللي مول.لتر-1 ول n=8 لمحلول الميتافورمين ومعدل النمذجة 30 انموذج/ ساعة . طبقت الطريقة لتقدير الميتافورمين في ثلاث نماذج من المستحضرات الصيدلانية . اجريت مقارنة بين الطريقة المستحدثة والطريقة التقليدية للقياس الطيفي(مطيافية الاشعة فوق البنفسجية وعند طول موجي 241 نانومتر) باستخدام نتائج منحني الاضافات القياسية وذلك باخضاعها لاختبار t- المزدوج وبين انه لايوجد فرق جوهري بين الطريقتين وبالامكان استخدام نظام: ميتافورمين- OH- - ايون النحاس(II) المحتوى داخل حبة الجيل كبديل اقل كلفة في استهلاك المواد الكيميائية مقارنة بالطريقة التقليدية.


Article
Flow injection analysis for the photometric determination of promethazine-HCl in pure and pharmaceutical preparation via oxidation by persulphate using Ayah 3SX3-3D solar micro photometer
التحليل بالحقن الجرياني للتقدير الطيفي للبروميثازين-هيدروكلورايد في المستحضرات الصيدلانية والنقية من خلال الاكسدة باستخدام بيرسلفات الصوديوم ومنظومة Ayah 3SX3-3D solar الطيفية

Authors: Nagam S. Turkey نغم شاكر تركي --- Issam M. A. Shakir عصام محمد علي شاكر
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2013 Volume: 10 Issue: 4 Pages: 1190-1202
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The first flow injection spectrophotometric method is characterized by its speed and sensitivity which have been developed for the determination of promethazine-HCl in pure and pharmaceutical preparation. It is based on the in situ detection of colored cationic radicals formed via oxidation of the drug with sodium persulphate to pinkish-red species and the same species was determined by using homemade Ayah 3SX3-3D solar flow injection photometer. Optimum conditions were obtained by using the high intensive green light emitted diode as a source. Linear dynamic range for the absorbance versus promethazine-HCl concentration was 0-7 mmol.L-1, with the correlation coefficient (r) was 0.9904 while the percentage linearity (r2%) was 98.09%. the L.O.Q was 3.97 µg/sample, while L.O.D (S/N=3) = 0.2407µg/sample (5 µmol.L-1) from the stepwise dilution for the minimum concentration of lowest concentration in the linear dynamic range of the calibration graph. The R.S.D% at 2 mmol.L-1 promethazine-HCl is less than 1% (eight replicates) using 150 µL sample volume. Throughput 30 sample.hr-1. The method was applied successfully for the determination of promethazine-HCl in pharmaceutical preparation. By using paired t-test it was shown that there was no significant difference between the proposed method and official method and on that basis the new method can be accepted as an alternative analytical method.

تم تطوير طريقة تحليلية طيفية سريعة وحساسة باستخدام تقنية الحقن الجرياني لتقدير بروميثازين – هيدروكلورايد في المستحضرات الصيدلانية والنقية. استندت الطريقة على التحسس الاني بالجذور الايونية الملونة والمتكونة من خلال اكسدة الدواء باستخدام بيرسلفات الصوديوم لتكوين اصناف بلون احمر – برمنغناتي وقياس الامتصاصية باستخدام منظومة مصنعة محلياً طيفية للتحليل بالحقن الجرياني المستمر Ayah 3SX3-3D solar FI photometer . تم دراسة الظروف المثلى باستخدام ثنائي الوصلة باعث للضوء الاخضر وبشدة عالية كمصدر للتشعيع. المدى الخطي الفعال لعلاقة تغير الممتصية مع التركيز للبروميثازين – هيدروكلورايد يمتد (0-7)مللي مول.لتر-1 وبمعامل ارتباط 0.9904 =r بينما نسبة الخطية 98.09 =%r2. حد التقدير الكمي (L.O.Q) 3.97 مكغم/انموذج بينما حدود الكشف (L.O.D) (S/N= 3) = 0.2407 مكغم /انموذج (5 مايكرومول.لتر-1) من التخفيف التدريجي لاقل تركيز في منحني المعايرة. الانحراف القياسي النسبي المئوي RSD% لتركيز 2 مللي مول.لتر-1 من البروميثازين – هيدروكلورايد اقل من 1% (تكرارية (8=n)) باستخدام حجم لانموذج محقن 150 مايكرولتر. معدل النمذجة = 30 انموذج/ساعة. طبقت الطريقة بنجاح لتقدير الدواء في المستحضرات الصيدلانية.باستخدام اختبار –tالمزدوج لوحظ انه لا يوجد فرق جوهري بين الطريقة المقترحة والطريقة القياسية، وعلى هذا الاساس بالامكان استخدام الطريقة المقترحة للتحليل بالحقن الجرياني الطيفي كبديل للطريقة القياسية.


Article
Determination of Atenolol in pharmaceutical formulations by continuous flow injection analysis via turbidimetric (T180o) and scattered light effect at two opposite position (2N90o ) using Ayah 4SW-3D-T180 -2N90 -Solar - CFI Analyser
تقدير الأتينولول في مستحضراته الدوائيه باستخدام تحليل الحقن الجرياني المستمر عن طريق قياس التعكريه (T180o) وتأثير استطاره الضوء عند اتجاهين متعاكسين (2N90o) باستخدام المحلل Ayah 4SW-3D-T180 -2N90 -Solar - CFI

Authors: Nagam S. Turkey Al-Awadie نغم شاكر تركي العوادي --- Ahmed F. Khudhair2 أحمد فاضل خضير
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2014 Volume: 55 Issue: 1 Pages: 12-26
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A simple, rapid and sensitive method for the analysis of Atenolol in pure and pharmaceutical preparation as an alternative analytical procedure were developed by continuous flow injection analysis via turbidimetric (T180o) and scattered light effect at two opposite position (2N90o). The method is based upon the formation of white precipitate for the ion pair compound by phosphomolybidic acid with Atenolol in aqueous medium. The precipitate is measured via the attenuation of incident light and scattering of the incident light in two opposite direction namely +90o and -90o angle were measured. Chemical and physical parameters were investigated. The linearity of Atenolol is ranged from (0.1-11) mmol.L-1, with correlation coefficient r=0.9938, lower limit of detection (LOD) 0.05 mmol.L-1(3SB)(S/N=3) for n=13 and the relative standard deviation for 7 mmol.L-1 Atenolol solution is lower than 3% (n=7). The method was applied successfully for the determination of atenolol in three pharmaceutical drugs. A comparisons were made between the newly developed method of analysis with the classical method ( uv-spectrophotometry at wave length 274nm) of analysis using the standard addition method via the use of t- test. It shows that there was no significant difference at α=0.05(95% confidence) between the two methods. Therefore the newly developed method can be accepted as an alternative method for the analysis of Atenolol, in addition to comparison between the official value and the calculated value for both methods

استحدثت طريقة بسيطة وسريعة لتقدير أتينولول بشكله النقي او على هيئة مستحضرات دوائية من خلال اقتران تقنية الحقن الجرياني المستمر مع قياس التعكريه والاستطاره. تستند الطريقة على تكوين راسب ابيض لمزدوج ايوني بين الاتنولول وحامض مولبدات الفسفوريك في الوسط المائي , تم قياس التعكرية للراسب عن طريق توهين الضوء الساقط وكذلك استطارته عند زاوية قائمه وابأتجاهين متعاكسين +90 و – 90 . تم دراسة المتغيرات الكيميائية والفيزيائية للحصول على الضروف المثلى لتعين الأتينولول, مدى الخطية للأتينولول بين (0.1-11 ) مللي مول.لتر-1 مع معامل الارتباط r=0.9938 وحدود الكشف (L.O.D) 0.05 ملي مول.لتر-1 (3SB) (S/N = 3) ولـ n = 13 ,الانحراف القياسي المئوي اقل 3% لتركيز 7 مللي مول.لتر-1 أتينولول ل(n = 7). طبقت هذه الطريقة بنجاح لتعين الأتينولول في ثلاثة عقاقير دوائية. اجريت مقارنة بين الطريقة المستحدثة مع الطريقة التقليدية للقياس الطيفي ( مطيافية الأشعة فوق البنفسجية عند طول موجي 274نانومتر) باستخدام طريقة الاضافات القياسية وذلك من خلال استخدام اختبار- t ولوحظ عدم وجود فرق جوهري عند 0.05= α وحدود ثقه 95% بين الطريقتين وبالامكان استخدام الطريقه المستحدثه كطريقة بديلة لتقدير أتينولول , بالاضافه الى المقارنه بين القيمه الرسميه والقيمه المحسوبه لكلا الطريقتين .


Article
New Approach for the On-Line Spectrophotometric Determination of Folic Acid in Pure and Pharmaceutical Preparation via Oxidation by Cerium(IV) Sulphate Using Ayah 3Sx3-3D-Solar Cell CFI Spectrophotometer Analyzer
نمط جديد للتقدير الاني الطيفي لحامض الفوليك في المستحضرات الصيدلانية والنقية من خلال الاكسدة بكبريتات السيريوم (IV) بأستخدام المحلل الطيفي للحقن الجوياني المستمر Ayah 3Sx3-3D-solar cell

Author: Aktham N. Jasim اكثم نصيف جاسم
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2014 Volume: 55 Issue: 3B Pages: 1153-1163
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A newly photometric analytical method characterized by its speed and sensitivity was developed for the determination of folic acid in pure and pharmaceutical samples via its oxidation to reddish-orange coloured complex through oxidation by cerium (IV) sulphate in aqua medium using homemade Ayah 3Sx3-3D-solar cell CFI photometer. The colored species were determined using supper bright green light emitting diode (LED) as a source. A 100µl was taken as a best sample volume for the determination of folic acid. The linearity of calibration curve for the instrument response versus folic acid concentration was 0.005-20 mmol.L-1 while the L.O.D. was 0.5  mol.L-1 from the stepwise dilution for the minimum concentration of lowest concentration in the linear dynamic range of the calibration graph. The correlation coefficient (r) was 0.9994 while the percentage linearity (r2%) was 99.88%. The method was applied successfully for the determination of folic acid in pharmaceutical preparation. RSD% for 8 mmo.L-1 (n=6) less than 1% . Using paired t-test it was shown that there was no significant difference between the proposed method and official method (Quoted value- 5mg) and on that basis the new method can be accepted as an alternative analytical method.

طورت طريقة تحليلية طيفية سريعة وحساسة لتقدير حامض الفوليك في المستحضرات الصيدلانية والنقية من خلال الاكسدة إلى معقد ملون برتقالي -محمر بوساطة اكسدته بكبريتات السيريوم (IV) في الوسط المائي بأستخدام منظومة الحقن الجرياني المستمر والمصممة محليا Ayah 3Sx3-3D-solar cell .قدرت القطع الملونة باستخدام ثنائي وصلة باعث للضوء الاخضر الساطع كمصدر تم اخذ 100 مايكروليتر كأفضل حجم لانموذج محقن لتقدير حامض الفوليك. الخطية لمنحني المعايرة للاستجابة الالية ضد تركيز حامض الفوليك 0.005-20 مللي مول.لتر-1 بينما حد الكشف 0.5 مايكرومول.لتر-1 من التخفيف التدريجي لاقل تركيز في منحني المعايرة . معامل الارتباط (r) 0.9994 بينما نسبة الخطية (r2%) 99.88% . طبقت الطريقة بنجاح لتقدير حامض الفوليك في المستحضرات الصيدلانية . الانحراف القياسي النسبي المئوي لتركيز 8 مللي مول. لتر-1 (n=6) اقل من 1% . بأستخدام اختبار t- المزدوج تبين انه لايوجد فرق جوهري بين الطريقة المقترحة والطريقة الرسمية (القيمة الموثقة -5 ملغم) وعلى هذا الاساس بالامكان قبول استخدام الطريقة المستحدثة كطريقة تحليلية بديلة.


Article
New Approach for an On-Line Turbidimetric Determination of Cadmium (II) in Different River Water Via the Use of A homemade Ayah 6SX1-T-2D Solar-Continuous Flow Injection Analyser
نمط جديد لقياس التعكرية الأني لتقدير ايون الكادميوم في مختلف مياه الانهر من خلال محلل جديد مصنع محليا للحقن الجرياني المستمر Ayah 6SX1-T-2D Solar) ).

Authors: Nagam S.Turkey نغم شاكر تركي العوادي --- Omar A. Yassin عمر اياد ياسين
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2014 Volume: 55 Issue: 4A Pages: 1402-1414
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A newly developed analytical method characterized by its speed and sensitivity for the determination of cadmium (II) in aqueous solution in three randomly chosen samples from river water at different locations via turbidimetric measurement by Ayah 6SX1-T-2D Solar - CFI analyser. The method is based on the formation of yellowish white precipitate for the complex Cd3[Fe(CN)6]2 by direct reaction of the cadmium (II) with potassium hexacyano ferrate (III) in aqueous medium. Turbidity was measured via the reflection of incident light that collides on the surfaces precipitated particles at 0-180o. Chemical and physical parameters were investigated. Linear dynamic of cadmium (II) is ranged from 0.05-12 mmol.L-1, with correlation coefficient r = 0.9951. The limit of detection 25.29 ng/ sample from the step wise dilution for the minimum concentration in the linear dynamic range of the calibration graph with RSD % lower than 1.5% for 8 mmol.L-1 (n=5) concentration of cadmium (II). The method was applied successfully for the determination of cadmium (II) in three river samples. A comparison was made between the proposed method of analysis with the classical method (HANNA instrument for turbidity measurement) using the standard additions method via the use of ANOVA-treatments. It was noticed that there is a significant difference at α=0.05 between the two methods at level < 0.05 was obtained. On that basis the new method can be accepted as an alternative analytical method.

تم تطوير طريقه تحليلية جديدة , تميزت بالسرعة والحساسية لتقدير ايون الكادميوم الثنائي في المحاليل المائية لثلاث نماذج عشوائية الاختيار من مياه الانهر ولمواقع مختلفة عن طريق قياس التعكرية بوساطة محلل الحقن الجرياني المستمر Ayah 6SX1-T-2D Solar. استندت الطريقة على تكوين راسب ابيض مصفر للمعقد Cd3[Fe(CN)]2 بوساطة التفاعل المباشر لايون الكادميوم (II) مع بوتاسيوم سداسي سيانيد الحديديك K3[Fe(CN)6] في وسط مائي. تم قياس التعكرية عن طريق انعكاس الضوء المسلط والمصطدم بسطوح دقائق الراسب بزاوية 0-180o. تم دراسة كافة المتغيرات الفيزياوية والكيميائية. العلاقة الخطية لمنحني المعايرة لايون الكادميوم (II) تمتد من 0.05-12 مللي مول.لتر-1 بمعامل ارتباط r = 0.9951 . حدود الكشف كانت = 25.29 نانوغم / انموذج من التخفيف التدريجي لاقل تركيز في منحني المعايرة مع انحراف قياسي نسبي مئوي RSD% اقل من 1.5 % لتركيز 8 مللي مول.لتر-1 (n=5) من ايون الكادميوم (II) . طبقت الطريقة بنجاح لتقدير ايون الكادميوم (II) في ثلاث نماذج لمياه النهر. اجريت مقارنة بين الطريقة المستحدثة للتحليل والطريقة التقليدية لقياس التعكرية باستخدام منحني الاضافات القياسية وبوساطة المعالجة بتحليل المتغيرات (ANOVA). لوحظ انه يوجد فرق جوهري بين الطريقتين عند مستوى قناعة 95% , حيث تم الحصول على sig > 0.05 . على هذا الاساس بالامكان قبول الطريقة الجديدة كطريقة تحليلية بديلة.


Article
New Mode for the On-Line Determination of Amiloride in Pure and Pharmaceutical Preparation Using CFIA Via the Use of Linear Array from Six LED (Snow White) with One Solar Cell in a Homemade Ayah 6Sx1-T-1D Solar CFI Analyser
نمط جديد للتقدير الاني للاميلورايد في المستحضرات الصيدلانية والنقية باستخدام التحليل بالحقن الجرياني المستمر عن طريق مصفوفة خطية لـ ست ثنائي وصلة باعث للضوء الابيض الثلجي مع خلية شمسية في محلل لقياس التعكرية Ayah 6Sx1-T-1D solar CFI

Author: Issam M.A. Shakir عصام محمد علي شاكر
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2014 Volume: 55 Issue: 4B Pages: 1708-1720
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A newly flow injection-turbidimetric method characterized by it is speed and sensitivity has been developed for the determination of Amiloride in pure and pharmaceutical preparations. It is based on the formation of yellowish white precipitate for the Amiloride-phosphomolybidic acid ion pair in aqueous medium. Turbidity was measured by Ayah 6Sx1-T-1D solar cell CFI analyser via the attenuation of incident light from the surfaces precipitated particles at 0-180. The Chemical and physical parameters were investigated. Linear dynamic range for the attenuation of incident light versus Amiloride concentration was of 0.005-10 mmol.L-1, with the correlation coefficient (r) of 0.9986 , while the percentage linearity (r2%) was 99.71%. The L.O.Q was of 23.14 µg/sample, while L.O.D (S/N=3) =5.74 ng/sample from the stepwise dilution for the minimum concentration in the calibration graph. The R.S.D% at 3, 9 mmol.L-1 Amiloride is less than 0.5% (eight replicates) using 50 µL sample volume. Through put was of 40 sample.hr-1. The method was applied successfully for the determination of Amiloride in pharmaceutical preparations. A comparison was made using the standard additions method via the use paired t-test. It showed that there was no significant difference between the quoted value of each individual paired t-test with calculated t-value at 95% confidence interval from developed method. In addition to comparison between two methods and calculate t-value, it was noticed that there was no significant difference between the two methods at =0.05 (95% confidence level).

طورت طريقة جديدة بالحقن الجرياني لقياس التعكرية وتميزت بالسرعة والحساسية لتقدير الاميلورايد في المستحضرات الصيدلانية والنقية. استندت على تكوين راسب ابيض مصفر للمزدوج الايوني: اميلورايد-حامض موليبدات الفسفوريك في الوسط المائي. تم قياس التعكرية بوساطة محلل الحقن الجرياني المستمرAyah 6Sx1-T-1D solar cell-CFI analyser عن طريق توهين الضوء المسلط من على سطوح دقائق الراسب بزاوية 0-180. تم دراسة الظروف الفضلى من المتغيرات الفيزيائية والكيميائية. المدى الخطي الفعال لعلاقة توهين الضوء الساقط ضد تركيز الاميلورايد 0.005-10 مللي مول.لتر-1 مع معامل ارتباط (r): 0.9986 ونسبة الخطية (r2%)=99.71%. معامل التقدير الكمي (L.O.Q) : 23.14 مكغم/انموذج بينما حد الكشف (S/N=3) L.O.D 5.74 نانوغرام/انموذج من التخفيف التدريجي لاقل تركيز في منحني المعايرة. الانحرافالقياسي النسبي المئوي لتركيز 3 و9 مللي مول.لتر-1 من الاميلورايد اقل من 0.5% (تكرارية لثمان مرات) باستخدام حجم لانموذج محقن 50 مايكرولتر. معدل النمذجة 40 انموذج/ساعة. طبقت الطريقة بنجاح لتقدير الاميلورايد في المستحضرات الصيدلانية. اجريت مقارنة باستخدام منحني الاضافات القياسية و اختبار-t المزدوج ولوحظ عدم وجود فرق جوهري بين القيمة الرسمية للاختبارات الانفرادية وقيمة t-المحسوبة عند فاصل ثقة 95% للطريقة المطورة بالاضافة الى اجراء مقارنة بين الطريقتين ولوحظ عدم وجود فرق جوهري بينها عند =0.05 (مستوى الثقة 95%).


Article
New Approach for the On-Line Spectrophotometric Determination of Vanadium (V) In Different River Water via the Use of a Homemade Ayah 6SX1-T-2D Solar-Continuous Flow Injection Analyser
نمط جديد للتقدير الأني الطيفي لأيون الفناديوم في مختلف مياه الانهار من خلال محلل جديد مصنع محليا للحقن الجرياني المستمر Ayah 6SX1-T-2D Solar) ).

Authors: Omar A. Yassin عمر اياد ياسين --- Nagam S.Turkey Al-Awadie نغم شاكر تركي العوادي
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2014 Volume: 55 Issue: 4B Pages: 1721-1735
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A new simple sensitive and selective spectrophotometric method has been developed for the analysis of vanadium(V) in three randomly chosen samples from river water at different locations by continuous flow injection analysis. The method based on the oxidation of pyrogallol by vanadium(V) in acidic solution to form color species and the same species was determined using homemade Ayah 6SX1-T-2D solar cell analyser . Chemical and physical parameters were investigated using the high intensity of snow white light emitted diode as a source. The linear dynamic range for the instrument response versus vanadium(V) concentration was 1-200 mg.L-1 with correlation coefficient r = 0.9920. The limit of detection (S/N=3) was 70 ng/ sample from the step wise dilution for the minimum concentration in the linear dynamic range of the calibration graph with RSD % of lower than 1% at 90 mg.L-1 (n=5) concentration of vanadium(V). The method was applied successfully for the determination of vanadium (V) in three river samples. A comparison was made between: both of the proposed methods and classical method (UV-Vis spectrophotometry at wave length 427 nm) using the standard additions method via the use of paired t-test. It was noticed that there was no significant difference between two methods at 95 % confidence level.

طورت طريقة تحليلية جديدة ، بسيطة, وانتقائية لتقدير ايون الفناديوم في المحاليل المائية لثلاث نماذج عشوائية الاختيار من مياه الانهار ولمواقع مختلفة عن طريق اكسده البايروكالول بفناديوم(V) في الوسط الحامضية لتكوين اصناف ملونة والتي قدرت باستخدام محلل الحقن الجرياني المستمر Ayah 6SX1-T-2D Solar المصنع محلياٌ. تم دراسة كافة المتغيرات الفيزيائية والكيميائية باستخدام شده عالية من ثنائي وصلة باعث للضوء الابيض الثلجي كمصدر. المدى الخطي لعلاقة تغير الاستجابة الالية مع تركيز الفناديوم ((V (1-200) ملي غم.مل-1 بمعامل ارتباط r=0.9920. حدود الكشف S/N)=3) 3SB))= 70 نانوغم/انموذج من التخفيف التدريجي لاقل تركيز في منحي المعايرة مع انحراف قياسي نسبي RSD% للتكرارية اقل من 1% لتركيز 90 ملي غم.لتر-1 ( (n=5من الفناديوم (V). طبقت الطريقة بنجاح لتقدير ايون الفناديوم(V) في ثلاث نماذج لمياه النهر. اجريت المقارنه بين الطريقتين (الطريقة المقترحه والطريقة التقليدية للقياس الطيفي عند λmax= 427 نانومتر) باستخدام منحني الاضافات القياسية عند اختبار t-المزدوج . لوحظ انه لايوجد فرق جوهري بين الطريقتين عند مستوى قناعة 95%.

Listing 1 - 10 of 39 << page
of 4
>>
Sort by
Narrow your search

Resource type

article (39)


Language

English (36)

Arabic (1)


Year
From To Submit

2019 (2)

2018 (2)

2017 (2)

2016 (2)

2015 (11)

More...