research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Hydraulic Paramters Of Groundwater Aquifers In Khanaqin Basin

Author: Hussein Ilaibi Zamil Al-Sudani
Journal: Journal of Basrah Researches (Sciences) مجلة ابحاث البصرة ( العلميات) ISSN: 18172695 Year: 2017 Volume: 43 Issue: 2A Pages: 80-95
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

ABSTRACT Estimating the physical properties of water-bearing layers is an essential part ofgroundwater studies. One of the most effective ways of determining these properties is toconduct and analyze aquifer tests. The aim of this research is to carry out hydrogeologicalinvestigation in Khanaqin basin within Diyala Governorate in the east of Iraq to calculatehydraulic parameters of the most important product groundwater aquifers. Cooper-Jacoband Theis Recovery test methods were used to calculate transmissivity and storagecoefficient after field investigation of aquifers extended in the basin. The geographicalposition, elevations, static water levels, depths, thicknesses and maximum yields werecarried out during field work. The results showed that Khanaqin basin has two geologicalunits represented by unconfined and confined aquifers, where (4) wells were used inpumping test. The average transmissivity parameter was ranged between (273-4590m2/day) in unconfined aquifer while this range was (14.47-244.35 m2/day) in confinedaquifer. Transmissivity contour map indicated increasing value of this parameter towardsnorthern west direction of the Khanaqin basin. Storage coefficient ranged between(3.5*10-5) to (1.14*10-3). The increasing of transmissivity parameter as groundwatermovement generally flow towards the northern west leading to increase groundwaterdischarge from wells penetrate unconfined and confined aquifers


Article
The Exploitation of Dar-Zarrouk Parameters to Differentiate Between Fresh And Saline Groundwater Aquifers of Sinjar Plain Area.
توظيف معاملات دار الزاروق في تمييز المياه الجوفية العذبة عن المالحة في منطقة سهل سنجار

Authors: Wadhah M. Shakir وضاح محمود شاكر --- Nawal A. Alridha نوال عبد الرضا --- Ameen I. Al-Yasi امين ابراهيم حسون الياسي
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2013 Volume: 54 Issue: 2 Pages: 358-367
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This research discusses the exploitation of Dar-Zarrouk (D-Z) parameters which were deduced from the quantitative interpretation of 80 Schlumberger Vertical Electrical Sounding VES points distributed in six profiles within the Sinjar plain area which bounded by the coordinates:Latitudes :35o 22’ 00’’ S – 36o 22’ 00’’ N ; longitudes : 41o 36’ 00’’ W – 43o 00’ 00’’ E. The VES field data were provided by the Iraqi general commission of groundwater. The VES field readings were interpreted manually by applying the (auxiliary point -partial resistivity curve matching) method, then the interpretation enhanced by using sophisticated computer software. The VES field data were interpreted and analyzed with an advanced technique through the deduction of D-Z geoelectric parameters which are: Longitudinal unit conductance (S) and Transverse resistance (T), then a new geoelectric maps were constructed. The D-Z parameters maps were used to differentiate aquifers of fresh groundwater from those of saline ones. This technique reduced the ambiguity related to interpretation which mainly produced by principles of equivalence and suppression and cause intermixing in recognizing depth limits for the electrical zones (fresh and saline water bearing formations) during interpretation. The drawing of (D-Z) and other geoelectric parameters maps provided a decipherable vision about the occurrence and distribution of saline and fresh groundwater aquifers within the study area.

36’ 00’’ W – 43o 00’ 00’’ E . تم توفير المعلومات الحقلية للمسح الكهربائي الذي اجري من قبل الهيئة العامة للمياه الجوفية العراقية و قد تم تفسيرها يدويا" بأستخدام طريقة النقطة المساعدة للمطابقة الجزئية مع المنحنيات القياسية ثنائية الطبقة ثم تحسين النتائج من خلال التفسير لاحقا" بأستخدام برنامج حاسوب مخصص لهذا الغرض. تضمن تحليل نتائج التفسير حساب معاملات دار الزاروق الجيوكهربائية والتي تمثل التوصيلية الطولية(S) و المقاومة المستعرضة (T) و التي استخدمت لاحقا" في عمل خرائط لمنطقة الدراسة لغرض التمييز بين الخزانات ذات المياه الجوفية العذبة عن تلك ذات المياه الجوفية المالحة. ان هذه التقنية في التفسير تقلل من الغموض المصاحب للتفسير و الذي يسببانه مبدأي التكافؤ و الاخماد و اللذان يؤديان الى حدوث خلط في التمييز بين الحدود العمقية للانطقة الكهربائية الحاوية على المياه الجوفية العذبة عن تلك الحاملة للمياه المالحة عند التفسير. لذا فأن خرائط معاملات دار الزاروق الجيوكهربائية ستوفر نظرة واضحة عن كيفية التمييز بين هذين النوعين من الانطقة الكهربائية في منطقة الدراسة .هذه الدراسة تناقش توظيف معاملات دار الزاروق المستحصلة من تحليل معلومات الجس الكهربائي الارضي العمودي (ترتيب شلمبرجر) لثمانين نقطة جس موزعة على ستة مسارات ضمن منطقة سهل سنجار و المحصورة ضمن الاحداثيات Latitudes :35o 22’ 00’’ S – 36o 22’ 00’’ N ; longitudes : 41o

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic and English (1)

English (1)


Year
From To Submit

2017 (1)

2013 (1)