research centers


Search results: Found 6

Listing 1 - 6 of 6
Sort by

Article
Experimental Investigation of Short Square Normal and Hybrid Fiber Reactive Powder Concrete Columns Subjected to Chloride Solution Attack
التصرف العملي للأعمدة الخرسانية القصيرة مربعة المقطع ذات الخرسانة العادية والمساحيق الفعاله المسلحة بالياف هجينة والمعرضة لهجوم محلول الكلورايد

Authors: Mohammed Mosleh Salman محمد مصلح سلمان --- . Husain Khalaf Jarallah حسين خلف جارالله --- Raed Satar Al-Behadili رائد ستار البهادلي
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2018 Volume: 24 Issue: 7 Pages: 75-94
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this research, the structural behavior of reinforced concrete columns made of normal and hybrid reactive powder concrete (hybrid by steel and polypropylene fibers) subjected to chloride salts with concentration was 8341.6 mg/l. The study consists of two parts, the first one is experimental study and the second one is theoretical analysis. Three main variables were adopted in the experimental program; concrete type, curing type and loading arrangement. Twenty (120x120x1200) mm columns were cast and tested depending on these variables. The samples were reinforced using two different bars; Ø8 for ties and Ø12 with minimum longitudinal reinforcement (0.01Ag). The specimens were divided into two main groups based on curing type: The first group consists of casting and testing of ten columns that cured in tap water for 28 days with two types of concrete (normal and hybrid), five columns for each type. While the second group consists of ten columns that direct cured and fully immersed in chloride water (8341.6 mg/l) 6 months with two types of concrete (normal and hybrid), five columns for each type. The specimens were tested under three types of loading, the first one is axial load, the second one is eccentric load with three different eccentricities (50,100 and 150) mm and where (e/h) are (0.42, 0.83 and 1.25) respectively from the center of column while the third type of loading is tested the specimens as beam.The experimental results showed an increase in ultimate load capacity and higher chlorides resisting for hybrid reactive powder concrete in comparison with normal concrete in both types of curing (tap and chloride water) through studying strain profile. Interaction diagram charts were obtained from different types of loading for each specimen. These charts showed high values for hybrid reactive powder concrete in comparison with normal concrete.

في هذا البحث تم دراسة التصرف الانشائي للاعمدة الخرسانية والمعرضة للاملاح الكلوريدية و (بتركيز 8341.6 ملغملتر) في نوعين من الخرسانة العادية وذات المساحيق الفعاله والمهجنة بالالياف ((steel and polypropylene fibers. تم اجراء ( جانبين في البحث الاول الجانب العملي والثاني الجانب النظري. يتضمن الجانب العملي ثلاث متغيرات هي نوع الخرسانة ونوع المعالجة ونوع التحميل, حيث تم صب وفحص 20 عمود خرساني بابعاد (120 × 120) ملم وبارتفاع 1200 ملم واستخدام نوعين من الاقطار لحديد التسليح Ø8 للاطواق المقاومة للقص و Ø12 التسليح الطولي وبنسبة 1%, تم تجزئة الجانب العملي الى جزئين: الجزء الاول وهو صب 10 اعمدة ومعالجتها في المياه العادية لمدة 28 يوم بنوعين من الخرسانة العادية والمهجنة 5 اعمدة لكل نوع خرسانة اما الجزء الثاني هو صب 10 اعمدة ومعالجتها بالمياه الكلوريدية و (بتركيز 8341.6 ملغملتر) وغمرها كليا لمدة 6 اشهر وايضا بنوعين من الخرسانة ولكل نوع 5 اعمدة.في الفحص تم تسليط ثلاث انواع من الحمل وهي الحمل المحوري واللامحوري وهي (50, 100, 150) ملم ونسبة ( (e/h0.42 , 0.83 و 1.25 ) من سنتر العمود والحمل الاخير هو فحص النموذج كعتبة.اظهرت النتائج العملية زيادة في الحمل والمقاومة في كلا المعالجة العادية والكلوريدية للخرسانة المهجنة مقارنة بالخرسانة العادية من خلال الحصول على interaction diagram chart, strain profile من خلال اختلاف نوع الحمل لكل نموذج حيث اظهرت النتائج الارقام العالية لرسم ال chart للخرسانة المهجنة مقارنة بالعادية.


Article
Mechanism of Hybrid Reinforcement and its Effect on some Properties of Binary Polymer Blend
ألية التسليح الهجين وتأثيرها على بعض الخواص لخليط بوليمري ثنائي

Authors: Awham M. Hameed --- Entihaa G. Daway
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 2 Part (B) Scientific Pages: 287-301
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The aim of current study is carrying out some modifying in properties of resin material (Unsaturated polyester, UPE) by adding thermoplastic material (polystyrene, PS) with different weight ratios included (0%, 5%, 10%, 15% and 20%) of (PS) to prepare binary polymer blend. The optimum ratio was selected in terms of the homogeneity case between the two polymers and studying the nature of the surfaces of the prepared materials using the optical microscope. Some mechanical tests were performed to determine the values of impact strength (I.S), ultimate tensile strength (UTS) for all prepared specimens. The ratio (80/20, weight/weight)% of (UPE/PS) blend was selected and reinforced with fibers volume fraction Фf = 10% using three types of fibers included(glass fibers (G.F), Carbon fibers (C.F) and hybrid from the two types (5% G.F and 5% C.F). All the above tests were repeated after the reinforcement for comparing the results and studying the behavior of materials under work. The results exhibited that the values of (I.S) increase with increasing of the blending ratio of (PS) while the values of (UTS) decrease at blending ratios (10, 15) % of (PS) and return to increase at the ratio 20% . After the reinforcement, it was found that the composite reinforced with carbon fibers records the highest values of impact strength for un notch specimens while the hybrid composite has the highest value of the ultimate tensile strength comparing with E-glass and carbon fibers composites.

الهدف من الدراسة الحالية هو اجراء بعض التحوير في خواص مادة راتنجية ( البولي استر غير المشبع , UPE) بأضافة مادة ثرموبلاستيكية (البولي ستايرين ,PS) وبنسب وزنية مختلفة شملت0,5 10, 15, 20) )% من البولي ستايرين لتحضيرخليط بوليمري ثنائي.وقد تم اختيارالنسبة المثلى بدلالة حالة التجانس بين البوليمرين ودراسة طبيعة السطوح للموادالمحضرة بأ ستخدام المجهر الضوئي. أجريت بعض الاختبارات الميكانيكية لتحديد قيم مقاومة الصدمة (I.S) , مقاومة الشد القصوى (UTS) لجميع النماذج المحضرة. تم اختيارالنسبة الوزنية (80/20)% من خليط البولي استر غير المشبع/ البولي ستايرين وسلحت بالالياف وبكسرحجمي (Фf = 10%) باستخدام ثلاثة انواع من الالياف شملت (الياف الزجاج (G.F), الياف الكاربون ((C.F وهجين من نوعي الالياف (5% G.F) و(5% C.F). تم تكرار جميع الاختبارات اعلاه بعد التسليح لغرض مقارنة النتائج ودراسة سلوك المواد قيد البحث. أظهرت النتائج بأن قيم (I.S) تزداد مع زيادة نسبة الخلط للبولي ستايرين في حين قيم (UTS) تنخفض عند نسبتي الخلط (10, 15)% من البولي ستايرين وتعود لتزداد عند النسبة 20%. وبعد التسليح اظهرت النتائج بأن المتراكب المسلح بألياف الكاربون يسجل القيم الاعلى لمقاومة الصدمة لنماذج غير محزوزة في حين المتراكب الهجين يمتلك القيمة الاعلى لمقاومة الشد القصوى مقارنة مع متراكبات الياف الزجاج والكاربون.


Article
PROPERTIES OF SUSTAINABLE HIGH PERFORMANCE LIGHTWEIGHT AGGREGATE CONCRETE REINFORCED WITH FIBERS
خواص خرسانة الركام الخفيف الوزن عالية الاداء والمستدامة المسلحة بالالياف

Loading...
Loading...
Abstract

يهدف هذا البحث الى انتاج خرسانة الركام خفيف الوزن عالية الاداء والمستدامة تحتوي على مكسر الطابوق الطيني المعاد تدويره من مخلفات البناء كركام خشن خفيف الوزن ومسلحة بالالياف الاحادية والهجينة المزدوجة والثلاثية بانواع ونسب باعية مختلفة. تم تحضير خرسانة عالية الاداء من مكسر الطابوق الطيني الخفيف الوزن بمقاومة انضغاط 41.2 نيوتنمم2 و كثافة جافة 1930 كغمم3 بعمر 28 يوم. الالياف المستخدمة تتضمن, الياف فولاذية معقوفة النهاية بنسبة باعية 60 (نوع S1 ), الياف بلاستك بنسبة باعية63, الياف فولاذية دقيقة معقوفة النهاية بنسبة باعية65 (نوع S ), والياف البولي بروبلين الدقيقة بنسبة باعية667. تم اعداد ست خلطات خرسانية تتضمن على, الخلطة المرجعية بدون الياف , خلطتان مسلحة بنوع واحد من الالياف (الالياف الفولاذية نوع S1 أو الياف البلاستك وبنسبة حجمية (0.75%, اثنان من الخلطات المسلحة بالالياف الهجينة المزدوجة ( الالياف الفولاذية نوع S 0.5%+ الياف بولي بروبلين0.25% وخلطة الياف البلاستك 0.5% + الالياف الفولاذية نوع S 0.25 %) والخلطة الخرسانية الهجينة ثلاثية الالياف (0.25 % ( الياف فولاذية نوع S1 +الياف البولي بروبلين + الياف فولاذية نوع S). تم دراسة الخواص الطرية للخرسانة (قابلية التشغيل والكثافة الطرية ) وخواص الخرسانة المتصلبة (الكثافة الجافة, مقاومة الانضغاط, مقاومة شد الانثناء, مقاومة الشد الانشطاري و الامتصاص للماء ). بصورة فان نماذج الخرسانة العالية الاداء الخفيفة الوزن والمسلحة بالالياف الاحادية والهجينة (الثنائية والثلاثية ) أظهرت زيادة مهمة في مقاومة الشد الانشطاري مقاومة شد الانثناء مقارنة بالنماذج الخرسانية المرجعية (بدون الالياف). ان نسب الزيادة في مقاومة الشد الانشطاري للنماذج المسلحة بالالياف الفولاذية الاحادية هي 55.8%, 65.9,%, 82% و 91.9%, بينما نسب الزيادة للنماذج المسلحة بالالياف البلاستكية الاحادية هي 34%, 45.5%, 61.5% و71.2% للاعمار 7, 28, 60 و 90 يوماً على التوالي بالمقارنة مع النماذج غيرالمسلحة بالالياف. ان اعلى مقاومة شد انشطاري و ومقاومة شد انثناء سُجلت للنماذج المسلحة بالالياف الهجينة ثلاثية الالياف. ان نسب الزيادة لمقاومة الشد الانشطاري للنماذج المسلحة بالالياف الهجينة ثلاثية الالياف هي 57.2%, 68.6 %, 87.5%, 101.8%, بينما نسب الزيادة لمقاومة شد انثناء هي 48 %, 59.6 %, 66.9%, 70.7%, للاعمار 7, 28, 60 و 90 يوماً على التوالي بالمقارنة مع النماذج غيرالمسلحة بالالياف.

In this investigation, sustainable High Performance Lightweight Aggregate Concrete (HPLWAC) containing recycled crushed clay brick from construction and demolition waste as coarse lightweight aggregate (LWA) and reinforced with mono fiber, double and triple hybrid fibers in different types and aspect ratios were produced. High Performance crushed brick lightweight aggregate concrete mix with compressive strength of 41.2MPa, oven dry density of 1930 kg/m3 at 28 days were prepared. The Fibers used including, macro hooked steel fiber with aspect ratio 60 (type S1), macro crimped plastic fiber (P) with aspect ratio 63, micro steel fiber with aspect ratio 65 (type S), and micro polypropylene fiber (PP) with aspect ratio 667. Six HPLWAC mixes were prepared including, one plain concrete mix (without fiber), two mono fiber reinforced concrete mixes ( reinforced with either steel fiber type S or plastic fiber with 0.75% volume fraction), two double hybrid fiber reinforced concrete mixes (0.5% steel fiber type S +0.25% polypropylene fiber and 0.5% plastic fiber + 0.25% steel fiber type S), and one mix with triple hybrid fiber (0.25% steel fiber type S1+0.25% polypropylene fiber +0.25% steel fiber type S). Fresh (workability and fresh density) and hardened concrete properties (oven dry density, compressive strength, splitting tensile strength, flexural strength and absorption) were studied. In general mono and hybrid (double and triple) fiber reinforced HPLWAC specimens give significant increases in splitting tensile strength and flexural strength compared with plain HPLWAC specimens. The percentages increase in splitting tensile strength for specimens with mono steel fiber are 55.8%, 65.9%, 82% and 91.9%, while for specimens with mono plastic fiber the percentages increase are 34%, 45.5%, 61.5% and 71.2% at 7, 28, 60, 90 days age respectively relative to the plain concrete. The maximum splitting tensile and flexure strengths were recorded for triple hybrid fiber reinforced HPLWAC specimens. The percentages increase in splitting tensile strength for triple hybrid fiber reinforced specimens are 57.2%, 68.6%, 87.5% and 101.8%, while the percentages increase in flexure strength are 48%, 59.6%, 66.9% and 70.7% at 7, 28, 60 and 90 days age respectively relative to the plain concrete specimens.


Article
Behavior of Hybrid Reactive Powder Concrete Columns Exposed to Chloride Attack
تصرف الاعمدة ذات الخرسانة الفعاله المهجنة المعرضة لهجوم الكلورايد

Authors: Mohammed M. Salman محمد مصلح سلمان --- Husain K. Jarallah حسين خلف جارالله --- Raed Satar Al-Behadili رائد ستار ورور
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2018 Volume: 21 Issue: 3 Pages: 327-343
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

In this paper, the cross section behavior of reinforced concrete columns made of normal and hybrid reactive powder concrete (hybrid by steel and polypropylene fibers) under concentric and eccentric vertical load was study. The casted columns were cured in two different type tap water for 28 days and chloride water for six months. Chloride salts with concentration was 8341.6 mg/l. Three variables were adopted in the experimental program; concrete type, curing type and the eccentricity of vertical load. Twenty (120x120x1200) mm columns were casted and tested depending on these variables. The different eccentricities were (0, 50,100 and 150) mm and where (e/h) were (0, 0.42, 0.83 and 1.25) respectively from the center of column, the other types of loading are tested the specimens as beam.The experimental results showed increasing in ultimate load capacity and higher chlorides resisting for hybrid reactive powder concrete in comparison with normal concrete in both types of curing (tap and chloride water). Through studying load deflection, test results for Normal Strength Concrete (NSC) and Hybrid Fiber Reactive Powder Concrete (HFRPC) columns that deflection for columns cured in chloride water more than tap water when compared at the same load that also by increase eccentricity leads to an increase in deflection for both cured and The neutral axis depth for HFRPC columns is more than NSC at the same load also when eccentricity increases, the compression zone decreases and neutral axis also decrease by increase eccentricity. These results occur when columns are cured in tap and chloride water.

في هذا البحث تم دراسة تصرف المقاطع للاعمدة الخرسانية المسلحة والمصنوعة من نوعين من الخرسانة العادية وذات المساحيق الفعالة والمهجنة بالالياف (steel and polypropylene fiber) تحت تأثير الحمل المحوري واللامحوري , تم صب الاعمدة ومعالجتها في نوعين مختلفين الاولى في المياه العادية ولمدة 28 يوم والثانية في المياه الكلوريدية ولمدة 6 اشهر و بتركيز ( 8341.6 ملغملتر) . يتضمن الجانب العملي ثلاث متغيرات هي نوع الخرسانة ونوع المعالجة ونوع التحميل, حيث تم صب وفحص 20 عمود خرساني بابعاد (120 × 120) ملم وبارتفاع 1200 ملم. في الفحص تم تسليط ثلاث انواع من الحمل وهي الحمل المحوري واللامحوري وهي (0, 50, 100, 150) ملم ونسبة (, 0) (e/h0.42 , 0.83 و 1.25 ) من سنتر العمود والحمل الاخير هو فحص النموذج كعتبة.اظهرت النتائج العملية زيادة في الحمل والمقاومة في كلا المعالجة العادية والكلوريدية للخرسانة المهجنة مقارنة بالخرسانة العادية من خلال الحصول على منحنيات القوى-الانفعال, نتائج الفحص للخرسانة العادية والمهجنة ومن خلال الرسوم تم استنتاج بأن الانفعال للخرسانة العادية والمهجنة عند معالجتها في المياه الكلوريدية هي اكثر من الانفعال لنفس الخرسانة عند معالجتها في المياه العادية. وكذلك بزيادة اللامحورية يزداد التشوه للخرسانة. وبنت النتائج بأن عمق المنطقة الانضغاطية للخرسانة ذات المساحيق الفعاله والمهجنة بالالياف هي اكثر من الخرسانة العادية عند نفس الحمل وكذلك بزيادة اللامحورية فان منطقة الانضغاط تقل وعمق المنطقة كذلك يقل وهذه النتائج تنطبق على كلا المعالجتين العادية والكلوريدية.


Article
A Study on Thermal Diffusivity and Dielectric Properties of Epoxy Matrix Reinforced by Fibers Material
دراسة الاْنتشار الحراري وخواص العزل الكهربائي لنسيج الايبوكسي المدعم بالألياف

Authors: Hakim S. Sultan Aljibori1 --- Firas K. Mohamad Alosfur2 --- Noor J. Ridha2 --- Mohammed Salim3
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2016 Volume: 14 Issue: 2 Pages: 42-53
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

The study of thermal diffusivity, dielectric properties and fabrication of fabric composite materials such as carbon fiber-epoxy, glass fiber-epoxy and hybrid fiber-epoxy composite materials are identified and reported in this paper. Hand layup method was used for the samples preparation. Thermal diffusivity of these samples was measured using photoflash method. The thermal diffusivity values of these materials were compared with the thermal diffusivity of several materials including ceramics (SrTiO3). The results show that carbon and glass fibers have lowest thermal diffusivity values compared with other materials. Dielectric constant, dielectric loss and conductivity were measured at room temperature using impedance analyzer technique. It was found that although hybrid material has the same behavior of glass fiber but the value of the dielectric constant was significantly increased.

في هذا البحث تم دراسة الانتشار الحراري و خصائص العزل الكهربائي لمواد نسيجية محضرة تحتوي على مادة راتنج الايبوكـسي مثل نسيج ألياف الكاربون- الايبوكسي، الياف الزجاج- الايبوكسي والمواد المركبة الهجينة من ألالياف و الايبوكسي. استخدمت طريقة الصب اليدوي (Hand layup) لتحضير العينات. لقد تمت مقارنة قيم الانتشار الحراري للمواد المحضره مع الانتشار الحراري لمجموعة من المواد بما في ذلك سيراميك التيتانات السترونتيوم .(SrTiO3) وقد أظهرت النتائج إن ألياف الكاربون والزجاج لها أدنى قيم للانتشار الحراري مقارنة مع المواد الأخرى. أيضا تم قياس ثابت العزل الكهربائي، و فقدان العزل الكهربائي والموصلية الكهربائية في درجة حرارة الغرفة باستخدام تقنية محلل المعاوقه. لقد تبين أنه على الرغم من أن المواد الهجينة لديها نفس سلوك الألياف الزجاجية ولكن قيمة ثابت العزل الكهربائي قد زادت بشكل ملحوظ


Article
EFFECT OF EXTERNAL SULFATE ATTACK ON MECHANICAL PROPERTIES AND MODELING OF HYBRID FIBER REACTIVE POWDER CONCRETE

Authors: Mohammed Mosleh Salman محمد مصلح سلمان --- Husain Khalaf Jarallah حسين خلف جارالله --- Shifaa Al-Bayati
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2017 Volume: 10 Issue: 3 Pages: 121-140
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

Sulfate attack is a serious factor play important role in the degradation of structural capacity of reinforced concrete structures members especially those members exposure with ground water or sea water. This paper study the effect of external sulfate attack on mechanical properties of hybrid fiber reactive powder concrete (HFRPC) containing (polypropylene fiber and steel fiber) and normal strength concrete (NSC) after specimens have been casted, directly and continuously cured, and full immersed in saline solution containing magnesium sulfate, the concentration of the sulfate ion used in this study was equal to upper limit defined in ACI318M building code (10000 ppm), other specimens have been direct and continuously cured and fully immersed in tap water, prepare 108 cylinder, 36 cube and 36 prism for this purpose. The mechanical properties such as compressive strength, splitting tensile strength (measured splitting resistance and tensile strength), modulus of rupture (measured tensile strength) and modulus of elasticity (measured flexural strength) tests were investigated for HFRPC and NSC at different exposure periods (28, 90 and 180) days. Test results showed continuous development with time in mechanical properties for HFRPC when cured in sulfate water but test results for NSC showed significant deterioration when cured in sulfate water. An analytical equations have been derived by curve fitting to derive the relationships between the mechanical properties and compressive strength for HFRPC and NSC and its validation with ACI predicted. The ACI expression for the mechanical properties may result in underestimation of HFRPC and good accuracy of NSC under tap water and sulfate water curing condition.

تعد مهاجمة الاملاح الكبريتية مشكلة رئيسية تؤثر بشكل سلبي على الخرسانة والمواد الانشائية المختلفة. تناول البحث تأثير الاملاح الكبريتية الخارجية على مقاومة خرسانة المساحيق الفعالة المحتوية على الياف هجينة (الياف البولي بروبلين والياف الحديد) والخرسانة العادية بعد غمر النماذج كليا وبشكل مباشر ومستمر بعد الصب في محلول ملحي احتوى على كبريتات المغنسيوم المضافة بتركيز مساوي لاعلى تركيز محدد بالكود الامريكي,وكان هنالك نماذج اخرى مغمورة بشكل كلي ومباشر في المياه الاعتيادية الخالية من الكبريتات, وقد تم تهيئة 108 اسطوانة و36 مكعب و36 موشور لهذا الغرض. أجريت فحوصات مقاومة الانضغاط و الشد بالانشطار الغير المباشر ومعامل الانحناء ومعامل المرونة لكل من خرسانة المساحيق الفعالة والخرسانة العادية خلال فترات مختلفة من المعالجة بالمياه الاعتيادية ومياه الكبريتات وتشمل فترات المعالجة(28 و90 و 180) يوم وقد اجريت هذه الفحوص لكل النماذج المعالجة بالمياه الاعتيادية والمعالجة بالكبريتات. أظهرت نتائج الفحوصات الخاصة بخرسانة المساحيق الفعالة تطور مستمر أثناء معالجتها بمياه ألاملاح الكبريتية(محلول كبريتات المغنسيوم),بينما حصل تدهور واضح في النتائج المستحصلة من الخرسانة العادية عند نفس ظروف المعالجة. تم اشتقاق معادلات خاصة بعلاقة الخواص الميكانيكية مع قوة الانضغاط للخرسانة العادية والهجينة باستخدام منحني المناسيب وتم مقارنتها مع معادلات الكود الامريكي. تبين من الدراسة ان معادلات الكود الامريكي تعطي قيم اقل للخرسانة الهجينة وقيم جيدة للخرسانة العادية تحت تأثير المعالجة بالمياه الاعتيادية والمعالجة بالكبريتات.

Listing 1 - 6 of 6
Sort by
Narrow your search

Resource type

article (6)


Language

English (6)


Year
From To Submit

2018 (2)

2017 (2)

2016 (1)

2014 (1)