research centers


Search results: Found 8

Listing 1 - 8 of 8
Sort by

Article
Flexural Behavior of Hybrid Tee Beams (Containing Reactive Powder Concrete and Normal Strength Concrete)
سلوك الإنثناء للعتبات الهجينة ذات المقطع (T) (الحاوية على خرسانة المساحيق الفعالة والخرسانة عادية المقاومة)

Loading...
Loading...
Abstract

Reactive powder concrete has superior mechanical and structural properties but the major drawback of this new construction martial is its high cost. This research presents experimental study to investigate flexural behavior of hybrid tee beams and study the ability of using normal strength concrete together with RPC in the same section to exploit the advantages of these two materials in optimal way. The experimental results showed that using RPC in the web and normal strength concrete in the flange effectively enhanced performance of hybrid T-section beams when compared with normal strength concrete T-beam, however, the increases in the first crack load, ultimate flexural load and ultimate deflection were 86.67%, 60% and 29.19% respectively, while, the increases for the case of using RPC in the flange and normal strength concrete in the web were 20%, 34.28% and 14.97 respectively when compared with normal strength concrete T-beam

خرسانة المساحيق الفعالة تمتلك خصائص ميكانيكية وإنشائية متفوقة لكن العيب الرئيسي لهذه المادة الإنشائية الجديدة هو كلفتها العالية. يقدم هذا البحث دراسة تجريبية لتحري سلوك الإنثناء للعتبات الهجينة ذات المقطع (T) ودراسة إمكانية استخدام الخرسانة العادية سوية مع خرسانة المساحيق الفعالة في نفس المقطع للعتبات للأستفادة من مميزات هاتين المادتين بأمثل طريقة. النتائج التجريبية بينت أن استخدام خرسانة المساحيق الفعالة في الجذع(web) والخرسانة العادية في الشفة flange)) حسنت بشكل كفوء أداء العتبات الهجينة ذات المقطع ((T ,حيث ان الزيادة في كل من حمل التشقق الاولي وحمل الإنثناء الاقصى والهطول الاقصى كانت ٨٦٫٦٧٪٦٠٬٪و٢٩٫١٩٪ على التوالي ٬بينما كانت الزيادة في حالة استخدام خرسانة المساحيق الفعالة في الشفة و الخرسانة عادية المقاومة في الجذع كانت ٢٠٪٬ ٣٤٫٢٨٪ و١٤٫٩٧٪ على التوالي بالمقارنة مع العتبة ذات الخرسانة عادية المقاومة.


Article
Experimental Behavior of Hybrid Steel and Polypropylene Fiber Reinforced Concrete Deep Beam Containing Openings Abstract-Twelve simple span reinforced concrete deep beams were

Authors: Nabeel A. al-Bayati --- Noor A. Hadi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2018 Volume: 36 Issue: 2 Part (A) Engineering Pages: 163-171
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Twelve simple span reinforced concrete deep beams were tested under symmetrically two points top load to examine the effect of steel fiber and polypropylene fiber and influence of the transverse circular openings on their behavior. The variables investigated involve beams with and without openings, the volume fraction of fibers, shear span to effective ratio a/d, and inclined reinforcement around the openings. All the beams had the same overall dimensions, flexural reinforcement and opening size. Many mixes have been used by combination between steel fibers and polypropylene fibers with different percentages of (1%SF-0%PPF), (0.75%SF-0.25%PPF), (0.5%SF-0.5%PPF), (0.25%SF-0.75%PPF), (0%SF-1%PPF) in addition to mix without fibers. The test results showed that fibers greatly increase the diagonal cracking strength and shear strength of reinforced concrete deep beams, where the variation of the type of concrete from normal concrete to hybrid concrete for deep beam contains openings led to increase the ultimate strength by about 30%. In addition, it was found that the shear capacity of deep beams increased when the shear-span/effective depth ratio decreased. The inclined reinforcement around the opening was observed to be very efficient in improving the ultimate load capacity and deflection response.


Article
PUNCHING SHEAR STRENGTHS OF HYBRID REINFORCED CONCRETE FLAT PLATE SLABS

Authors: Suha Rasheed Abass --- Haitham Jameel Abd
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2018 Volume: 22 Issue: 4 Pages: 101-115
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

This study is conducted to test experimentally the punching shear of reinforced concrete flat plate slabs made with hybrid concrete (two types of concrete in two layers in specimens. Twelve test slab with ( 450×450×50 ) mm dimension The tested slabs have been. divided into four groups, each of which consisted of three slab specimens identical in size and shape but different in concrete type and steel bar reinforcement. All slabs are simply supported along the all edges and subjected to single point load applied at the center of gravity of each slab.Experimental results show that the use of hybrid concrete and high strength concrete improves the punching shear resistance and allows higher forces to be transferred through the slab-column connection. For slab specimen which fully cast using high strength concrete, the ultimate shear capacity increased by (40%) in comparison with the normal concrete slabs. While, for slab specimens cast using with hybrid concrete the ultimate shear capacity increased by (5%-45%) in comparison with the normal concrete slabs.This experimental results revealed that the ultimate load capacity increase with the addition of super plasticizers to the mix of concrete.


Article
Nonlinear Finite Elements Modeling of HybridReinforced Concrete Beams
التمثيــل اللاخطــي بالعناصـــر المحـــددة للعتبــاتالخرسانيــة المسلــحة المهجنــة

Authors: شـذى صـاحب كـريم --- أكـرم شاكـر محمـود
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2010 Volume: 8 Issue: 3 Pages: 193-202
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

This paper presents results from a nonlinear finite element analysis of hybrid reinforced concrete rectangular section beams. The concept of hybrid R.C. concrete structures was applied by many designers for use in constructions of bridge superstructures. Although the steel reinforcement is often modeled as a linear-elastic material until failure, the linear finite element analysis could not predict the behavior of the R.C. concrete beams model up to failure. Results from material tests and loading tests of beams model indicated that the nonlinearity of concrete should be considered to predict the failure modes. In this study, an effort was made to implement a rate-independent plasticity model, which describes a constitutive model of concrete types (Normal and High Strength Concrete), in a finite element code. Results obtained from the numerical analysis showed a good correlation with the experimental results.

يُُعنى هذا البحث بنتائج تحليل لاخطي بالعناصر المحددة لعتبات مسلحة مهجنة ذات مقاطع مستطيلة. يُطبق مبدأ العتبات المهجنة من قبل الكثير من المصممين وذلك باستخدامه في الجسور. بالرغم من استخدام التحليل المرن-الخطي في تمثيل خصائص حديد التسليح لكن لا يمكنه تقدير السلوك للعتبات الخرسانية المسلحة وتَتبُعُها حتى حمل الفشل. اعتمدت النتائج من فحوصات المواد والأحمال على نموذج السلوك اللاخطي حيث في هذا البحث اُستخدم نموذج اللدن للخرسانة لوصفه بنوعيه ( خرسانة ذات تحمل اعتيادي وعالي) في العناصر المحددة. وقد أظهرت النتائج التي استخرجت من التحليل العددي توافق جيد مع النتائج العملية.


Article
Experimental Study for Punching Shear Behavior in RC Flat Plate with Hybrid High Strength Concrete
دراسة عملية لمقاومة القص الثاقب للسقوف الخرسانية المستوية المصنوعة من الخرسانة الهجينية عالية الانضغاط

Authors: Ban Sahib A. بان صاحب --- Shatha S. Kareem شذى صاحب كريم --- Ali H. Aziz علي حميد عزيز
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2013 Volume: 17 Issue: 3 Pages: 105-119
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

This Paper is conducted to investigate experimentally the punching shear behavior of hybrid flat plate. Five slab specimens with (1000x1000x70) mm dimensions have been tested, two of which have been made fully with High Strength Concrete and Steel Fiber Reinforced Concreter , while, the others have been made by mixing two types of concrete (Steel Fiber Reinforced Concreter in the critical zone and High Strength Concrete in the other part of slab specimen). The slab dimensions, main reinforcement have been kept constant in all slab specimens. The variables are concrete type and dimensions of critical area. Experimental results show that the use of SFRC improves the punching shear resistance and allows higher forces to be transferred through the slab-column connection. For slab specimen which made fully with SFRC, the ultimate shear capacity increased by (25%) in comparison with the normal slab. While, for slab specimens which made with hybrid concrete the ultimate shear capacity increased by (5%-13%) in comparison with the normal slab.

تأثير استخدام أنواع مختلفة من الخرسانة (الخرسانة الهجينية) في المنطقة الحرجة لالتقاء العمود مع البلاطة على مقاومة القص الثاقب في البلاطات الخرسانة الصفائحية تمت دراستها في هذا البحث. تم فحص خمسة بلاطات مربعة الشكل بأبعاد (1000*1000*70) ملم بالإضافة الى سلسلة من الفحوصات التي تم أجراءها على نماذج السيطرة لدراسة الخواص الميكانيكية لأنواع الخرسانة المستخدمة. المتغيرات في هذه الدراسة هي نوع الخرسانة في المنطقة الحرجة وأبعاد هذه المنطقة مع الإبقاء على أبعاد البلاطات و حديد التسليح دون تغيير .تعرضت كلا من النماذج المرجعية و بلاطات الفحص الى نفس الظروف المختبرية. أظهرت النتائج المختبرية أن الزيادة في مقاومة انضغاط الخرسانة حسن مقاومة القص الثاقب وهذا يسمح بانتقال قوة اكبر من خلال المفصل الرابط بين العمود والبلاطة. كذلك، بينت النتائج أن مقاومة القص الثاقب قد ازدادت بمقدار (25%) بالنسبة للبلاطات المسلحة بالكامل بألياف الحديد عند مقارنتها مع البلاطة العادية. أظهرت النتائج، كذلك، حصول زيادة في المقاومة القصوى للقص الثاقب بمقدار (5%-13%) بالنسبة للبلاطات المسلحة جزئيا بألياف الحديد عند مقارنتها مع البلاطة العادية.


Article
Behavior of Reinforced Hybrid Concrete Corbel-Column Connection with Vertical Construction Joint

Authors: Ammar Yasir Ali --- Waseem Hamzah Mahdi
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2017 Volume: 25 Issue: 1 Pages: 30-44
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

In this paper, shear behavior of reinforced hybrid concrete connection of corbel-column is experimentally investigated. Nine homogenous and hybrid concrete corbel-column connections subjected to vertical applied loads were constructed and tested within two test groups (A, B). The experimental program included the effect of several variables such as type of hybrid concrete;high strength concrete (HSC) or steel fiber reinforced concrete (SFRC), monolithic casting of hybrid concrete connection, and presence of construction joint at the interface of corbel-column. Experimental results showed significant effects of concrete hybridization on the structural behavior of connection specimens such as: ultimate strength, cracking loads, cracking patterns, and failure modes. Hybridization process in group (A) included hybrid connection of corbel-column with HSC or SFRC corbel instated of NSC. This process led to increase the capacity of connection by (26%, 38%) and shear cracking loads by (20%, 120%) respectively. Moreover, connections of hybrid concrete corbels cast monolithically improved the shear capacity of corbels by (19%, 42%) for HSC or SFRC respectively. In group (B), presence of construction joint at connection region reduced the shear capacity of connectionsby (10% to 22%) and cracking loads by (23%-62%) compared with connections cast monolithically.

تقدم هذه الدراسة تقصيا عمليا لسلوكمنطقة الاتصال بين العمود والكتف والمكونة من الخرسانة الهجينة. تضمنت الدراسة انشاء وفحص تسعة من نماذج الكتف الخرساني المرتبط بعمود الهجينة والمتجانسة تحت تأثير احمال عمودية ضمن مجموعتينA,B)).تضمن البرنامج العملي تأثير عدة متغيرات مثل نوع الخرسانة الهجينة;خرسانة عالية المقاومةHSC)) او الخرسانة الحاوية على الالياف الفولاذية (SFRC),الصب الموحد لمنطقة الاتصال الهجينة ,وجود مفصل انشائي في منطقة التداخل بين العمود والكتف. بينت نتائج الدراسة العملية وجود تأثيرات مهمة لتهجين الخرسانة على التصرف الانشائي لنماذج الاتصال من حيث: المقاومة القصوى ,احمال التشقق, نمط التشقق, شكل الفشل. عملية التهجين في المجموعةA)) تضمنت انشاء منطقة اتصال هجينة بين الكتف والعمود عن طريق صب الكتف بخرسانة عالية المقاومة او حاوية على الياف فولاذية بدلا من الخرسانة ذات التحمل الاعتياديNSC)).تؤدي هذه العمليةالى زيادة مقاومة منطقة الاتصال بحوالي26%, 38%)) واحمال تشققات القص بحوالي 20%, 120%)) على التوالي.اضافة الى ذلك , تزداد مقاومة القص في مناطق الاتصال ذات الاكتاف الخرسانية الهجينة التي تم صبها في وقت واحد بحوالي 19%-42%)) للأكتاف المهجنة بالخرسانة عالية المقاومة او الخرسانة الحاوية على الالياف الفولاذية على التوالي. في المجموعة B)),وجود مفصل انشائي في منطقة الاتصال يقلل من مقاومتها للقص بحوالي(10%-41%) واحمال التشقق بحوالي((23%- 62% مقارنة بمناطق الاتصال التي تم صبها في وقت واحد.


Article
Experimental Investigation for Behavior of Reinforced Hybrid Concrete Corbel-Column System Subjected to Un-Symmetrical Vertical Loading

Authors: Ammar Yasir Ali --- Waseem Hamzah Mahdi
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2017 Volume: 25 Issue: 2 Pages: 375-388
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

In this paper, shear and flexural behavior of reinforced hybrid concrete corbel-column system was experimentally investigated. Fourteen hybrid and homogenous concrete corbel-column systemssubjected to un-symmetrical loading were constructed and tested within two test groups (A, B). The experimental program included several variables such as: type of hybrid concrete;high strength concrete(HSC) or steel fiber reinforced concrete(SFRC), shear span to depth ratio (a/d), area of hybridization in corbel - column system.Experimental results showed significant effects of concrete hybridization on structural shear and flexural behavior including: ultimate strength, cracking loads, cracking patterns, failure modes, and ductility. Hybridization process ingroup (A) included casting the corbel with HSC or SFRC instated of normal strength concrete (NSC). In shear behavior corbels (a/d= 0.37), this process led to increase the shear capacity of corbel by (26%, 38%) and shear cracking loads by (20%, 120%) respectively. Furthermore, in flexural behavior corbels (a/d= 0.74) shear capacity increased by (19%, 42%), flexural cracking loads increased by (29%, 143%) for HSC and SFRC corbels respectively. In group (B) hybridization process included increasing the hybrid area of corbel-column system in group (A) to represent a distributed region (D-region) or decreasing it to represent hybrid corbel. In both cases shear capacity of corbel increased with a range of (10 to 41) % for specimens hybridized monolithically with HSC, while it increased with a range of (19 to 44) % for specimens hybridized monolithically with SFRC; compared with homogenous NSC specimens having same (a/d) ratio.

تقدم هذه الدراسة تقصيا عمليا لسلوك القص و الانحناء لنموذج الكتف الخرساني المرتبط بعمود والمكون من الخرسانة الهجينة في منطقة الاتصال بين العمود والكتف. تضمنت الدراسة انشاء وفحص اربعة عشر نموذج من نماذج الكتف الخرساني المرتبط بعمود الهجينة والمتجانسة تحت تأثير احمال غير متماثلة ضمن مجموعتينA,B)).تضمنت المتغيرات العمليةنوع الخرسانةالهجينة;خرسانة عالية المقاومةHSC)), الخرسانة الحاوية على الالياف الفولاذيةSFRC)), نسبة فضاء القص الى العمق الفعالa/d)) ,مساحة التهجين في نموذج الكتف الخرساني المرتبط بعمود. بينت نتائج الدراسة العملية وجود تأثيرات مهمة لتهجين الخرسانة على تصرف القص والانحناء من حيث: المقاومة القصوى ,احمال التشقق, نمط التشقق شكل الفشل والمطاوعة. عملية التهجين في المجموعةA)) تضمنت صب الكتف بخرسانة عالية المقاومة او حاوية على الياف فولاذية بدلا من الخرسانة ذات التحمل الاعتياديNSC) ).تؤدي هذه العمليةالى زيادة مقاومة القص للكتف بحوالي 26%, 38%)) واحمال تشققات القص بحوالي 20%, 120%)) على التواليفي الاكتاف التي يكون تصرفها هو القص a/d = 0.37)).اضافة الى ذلك في الاكتاف التي تتصرف تصرف الانحناء a/d=0.74)) تزداد المقاومة القصوى للكتف بحوالي 19%-42%)) اما احمال تشقق الانحناء تزداد بحوالي29%, 143%)) للأكتاف ذات الخرسانة عالية المقاومة او الخرسانة الحاوية على الالياف الفولاذية على التوالي.عملية التهجين في المجموعةB))تضمنت زيادة مساحة التهجين لنماذج الكتف الخرساني المرتبط بعمود في المجموعة A) ) لتمثل منطقة منتشرةD-region)) او تقليلها لتمثل كتف هجين. في الحالتين فان مقاومة الكتف تزداد بحوالي (10%-41%) للنماذج المهجنة باستخدام HSC)) والتي تم صبها في نفس الوقت بينما تزداد مقاومة الكتف بمدى يتراوح بين 19% - 44%)) للنماذج المهجنة باستخدام SFRC)) التي تم صبها في نفس الوقت مقارنة بنماذج الخرسانة ذات التحمل الاعتياديNSC)) والتي لها نفس نسبة فضاء القص الى العمق الفعال.


Article
Behavior of Reinforced Concrete Hybrid Trapezoidal Box Girders Using Ordinary and Highly Strength Concrete

Authors: Nameer A. Alawsh --- Teeba Haider Mehdi
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2018 Volume: 26 Issue: 5 Pages: 272-278
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

In this paper, the general behavior of reinforced concrete hybrid box girders is studied by experimental and numerical investigation. Experimental work is included casting monolithically five specimens of box girders with trapezoidal cross section and testing it as simply supported under two point loading. Two specimens were cast as homogenous box girders (full normal strength concrete (NSC) (about 35MPa) and full high strength concrete (HSC) (about 55MPa)) and three specimens were cast as hybrid box girders (HSC in upper flange only, HSC in upper flange and half depth of webs, and HSC in bottom flange and total depth of webs). Experimental results showed significant effects of concrete hybridization on the structural behavior ofbox girders specimens such as: cracking loads, cracking patterns, ultimate strengths, and failure modes. The ultimate strength of Hybrid box girders increased by 23% as average when compared with the homogenous box girder (full NSC) and decreased by 9% as average when compared with homogenous box girder (full HSC). In numerical investigation, the tested specimens were modeled and analyzed using three dimensional non-linear finite element analysis. The analysis was carried out by using a computer program (ANSYS V16.1). The numerical results showed an acceptable agreement with the experimental work with difference about (3.12% and 9.588%) as average for ultimate load and deflection, respectively.

تم في هذا البحث دراسة التصرف العام للروافد الخرسانية المسلحة ذات المقطع الصندوقي والمصنوعة من الخرسانة الهجينة (نوعين مختلفين من الخرسانة تصب ككتلة واحدة) عمليا ونظريا. تضمن الجزء العملي انشاء وفحص خمسة نماذج من الروافد الصندوقية مع مقطع شبه منحرف تحث تأثير فحص نقطي ثنائي التحميل. نموذجان من المقاطع الصندوقية تم صبهما من الخرسانة المتجانسة (احدهما من خرسانة عادية المقاومة (35MPa) والاخر من خرسانة عالية المقاومة (MPa55)) وثلاثة نماذج من الخرسانة الهجينة (خرسانة عالية المقاومة في: الشفة العليا فقط, الشفة العليا ونصف عمق الوترة, و الشفة السفلى والعمق الكلي للوترة). بينت نتائج الدراسة العملية وجود تأثيرات مهمة لتهجين الخرسانة على التصرف الإنشائي لنماذج الروافد الصندوقية من حيث: احمال التشقق, نمط التشقق, المقاومات القصوى, و اشكال الفشل. المقاومة القصوى للروافد الصندوقية ذات الخرسانة الهجينة ازدادت بنسبة حوالي 23% كمعدل بالمقارنة مع الروافد الصندوقية ذات الخرسانة المتجانسة (خرسانة عادية المقاومة) وقلت بنسبة حوالي 9% فقط. في الجزء النظري من الدراسة تم تمثيل وتحليل النماذج المفحوصة بشكل رقمي باستخدام طريقة العناصر المحددة. النماذج الرقمية تم تكوينها بثلاثة أبعاد باستخدام برنامج إلكتروني (ANSYS الإصدار 16.1). أظهرت النتائج النظرية (التحليلية) توافقا معقولا مع النتائج العمليةبنسبة اختلاف (3.12% و 9.588%) كمعدل بالنسبة للحمل الاقصى والهطول, على التوالي.

Listing 1 - 8 of 8
Sort by
Narrow your search

Resource type

article (8)


Language

English (6)

Arabic and English (1)


Year
From To Submit

2018 (3)

2017 (2)

2015 (1)

2013 (1)

2010 (1)