research centers


Search results: Found 5

Listing 1 - 5 of 5
Sort by

Article
OFF-GRID ELECTRICITY GENERATION WITH HYBRID RENEWABLE ENERGY TECHNOLOGIES IN IRAQ: AN APPLICATION OF HOMER
توليد الكهرباء بدون الشبكة الوطنية مع استخدام تكنولوجيا الطاقة البديلة الهجينة في العراق باستخدام تطبيق HOMER

Author: AMMAR ISSA ISMAEL عمار عيسى اسماعيل
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2015 Volume: 8 Issue: 4 Pages: 277-286
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

The current power system in Iraq used fossil fuels that effect an environmentally, also the power generated does not cover the power demand. In the other hand, to reduce the gap between the generation and the power demand suggested renewable energy alternative sources adding to power system, renewable energy is zero pollution. The purpose of this proposal is to find the preferable hybrid technology combination by a hybrid renewable energy resources for electricity generation to satisfy the electrical needs in a reliable manner of an off grid choosing small town, Bald Ruz in the state of Diyala, Iraq as case study. Three renewable resources, namely, solar photovoltaic systems, wind turbines, with natural gas generator are considered. The software used HOMER that offers optimal solution from the types of resources. The proposal estimates COE of energy of the optimized system is $0.998/kWh for stand-alone and $0.2/kWh for hybrid grid system. The PV system represents around 42% of power production small percentage for wind turbine that reaches to 6%.

نظام القدرة الحالية في العراق يستخدم الوقود الحفري التي توثر على البيئة وهذه القدرة لا تلبي حاجه القدرة المطلوبة للاستهلاك. ومن ناحية أخرى استخدام الطاقة البديلة توفر قدرة إضافية لتقليل الفجوة بين التوليد والمتطلبات وهذه الطاقة لا تنتج إي تلوث للبيئة. الغرض من هذا البحث المقترح إيجاد أفضل مزيج من مصادر توليد متعددة بدون استخدام ألشبكه الوطنية حيث تم اختيار مدينه بلدروز الواقعة في محافظه ديالى في العراق كنموذج للدراسة. سوف يستخدم ثلاث أنواع من الطاقة البديلة هي الطاقة الشمسية, طاقه الرياح وطاقه الديزل. المقترح خمن طاقة COE 0.998 دولار لكل kWh للنظام القائم بذاته بينما 0.2 دولار لكل kWh لنظام الشبكة ألهجيني. يمثل نظام PV نسبه 42% من القدرة المنتجة بينما نسبه قليله من تورباين الرياح الذي يصل إلى 6% من القدرة المنتجة.


Article
Enhancement of Hybrid Solar Air Conditioning System using a New Control Strategy
تحسين الاداء لنظام التبريد الشمسي الهجين باستخدام ستراتيجية سيطرة جديدة

Authors: Ahmed Abed Mohammed أحمد عبد محمد --- Raed Ayad Abduljabbar رائد اياد عبد الجبار
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2018 Volume: 14 Issue: 4 Pages: 24-33
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Enhancement of the performance for hybrid solar air conditioning system was presented in this paper. The refrigerant temperature leaving the condenser was controlled using three-way valve, this valve was installed after the compressor to regulate refrigerant flow rate towards the solar system. A control system using data logger, sensors and computer was proposed to set the opening valve ratio. The function of control program using LabVIEW software is to obtain a minimum refrigerant temperature from the condenser outlet to enhance the overall COP of the unit by increasing the degree of subcooled refrigerant. A variable load electrical heater with coiled pipe was used instead of the solar collector and the storage tank to simulate the solar radiation. Experimental data was measured to study the performance of the system. The proposed system was compared with the conventional one. Results show that the COP of the proposed system was higher than the COP of the conventional system by 10 %. In addition, the controlled system saved an electricity of 11.2 %. The optimum opening valve ratio fluctuated between 0.3 and 0.4 when the heater power was 500 W.

في هذا البحث تم دراسة تحسين الاداء لنظام التبريد الشمسي الهجين ، حيث تم نصب صمام تحكم ثلاثي بعد الضاغط مباشرة لغرض التحكم في درجة حرارة مائع التبريد الخارج من المكثف عن طريق تنظيم معدل تدفقه ، تم استخدام نظام سيطرة مع قارئ بيانات ومتحسسات وجهاز حاسوب للتحكم في نسبة فتحة الصمام ، تم استخدام برنامج LabVIEW للحصول على اقل درجة حرارة للمائع الخارج من المكثف وذلك لتحسين معامل الاداء الكلي للمنظومة من خلال زيادة درجة التبريد المفرط للمائع. تم استخدام سخان كهربائي متغير السعة مع انبوب ملف بدلا من المجمع الشمسي والخزان لمحاكاة الاشعاع الشمسي. تم قياس عدد كبير من البيانات لغرض دراسة اداء النظام ، تم مقارنة النظام المقترح مع النظام التقليدي وقد بينت النتائج أن معامل الاداء للنظام المقترح اعلى من النظام التقليدي بنسبة 10% ، ويرشد طاقة كهربائية بنسبة 11.2 % . وقد تراوحت نسبة فتحة الصمام ما بين 0.3 و 0.4 عندما كانت سعة قدرة السخان حوالي 500 واط.


Article
Design of Shell and Tube Heat Exchanger for Air Conditioning-Water Heating Hybrid System

Authors: Mohammed Jawad Yaseen --- Ahmed F. Atwan --- Alaa H. Shneishil
Journal: Journal of Education for Pure Science مجلة التربية للعلوم الصرفة ISSN: 20736592 Year: 2017 Volume: 7 Issue: 4 Pages: 1-15
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

AbstractThe use of air conditioning-water heating hybrid system for heating, cooling and hot water ofbuildings, has significantly importance for energy saving. It has been proposed a system to recoverthe waste heat of refrigerant after leaving the air conditioning system condenser in the heating modeand the waste heat of refrigerant after leaving the air conditioning system compressor in the coolingmode to heat water for domestics or other needs. Shell and tube heat exchanger has been designed asa refrigerant-to-water heat exchanger located between the condenser and the expansion valve in theheating mode and between the compressor and the condenser in the cooling mode. The simulationprogram of heat exchanger has been built by using (MATLAP) in order to determining the heattransfer parameters and the temperature difference between the inlet cold water and outlet hot water,the results show that the effectiveness decrease with increase of water mass flow rate, while increasewith increase of tube length. As the tube length (15) m, the outlet hot water temperature from heatexchanger is (60.94) °C, for water mass flow rate (0.15) kg/s, and this value decrease exponentiallyand reach to about (7.528) °C, for water mass flow rate (2) kg/s, while for tube length (5) m, thesevalues ranging between (43.92) °C, to (1.234) °C, respectively.


Article
Removal of Methyl Violet Dye From Synthetic Wastewater Using a Hybrid Detoxification Process
تنقية المياه من صبغة المثيل البنفسجية باستخدام الطريقة الهجينة لازالة السمية

Authors: Mohammad F. Abid --- Amir A, Abdul-Rahman --- Noor H. Hamza
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 6 Part (A) Engineering Pages: 1544-1561
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The aim of the present study was to design a solar reactor and analyze its performance for removal of methyl violet dye (MV) from water with titanium dioxide as the photocatalyst. The solar reactor was made up of a flat-plate colorless glass of dimensions 1000 x 750 x 4 mm. The base of the reactor was made of aluminum. Various operating parameters were studied to investigate the behavior of the designed reactor like initial dye concentration (CMV=10-50 mg/L), loading of catalyst (CTiO2=200-800 mg/L), suspension flow rate (QL=0.3-2 L/min), pH of suspension (5-10), and H2O2 concentration (CH2O2=200-1000 mg/L). The operating parameters were optimized to give higher efficiency to the reactor performance. The designed reactor when operating at optimum conditions offered a degradation of MV up to 95.27% within one hours of operation time, while a conversion of 99.95% was obtained in three hours. The effluent from the photocatalytic reactor was fed to a LPRO separation system which produced a permeat of turbidity value of 0.09NTU. The product water was analyized using UV-spectrophotometer and FTIR. The analysis results confirmed that the water from the Hybrid-system could be safely recycled and reuse. It was found that the kinetics of dye degradation was first order with respect to dye concentration and could be well described by Langmuir-Hinshelwood model.

يهدف البحث الى دراسة كفاءة مفاعل الطبقة الساقطة في ازالة صبغة المثيل البنفسجية من المياه باستخدام ضوء الشمس وثاني اوكسيد التيتانيوم كعامل مساعد. ثم بحث تأثير المتغيرات التشغيلية (تركيز الصبغة, تركيز العامل المساعد, معدل تدفق السائل, حامضية المحلول, تركيز بيروكسيد الهيدروجين) على كفاءة اداء المفاعل في ازالة الصبغة. بعد ايجاد افضل الظروف التشغيلية التي تؤدي الى اعلى كفاءة للمفاعل وقد وجد ان المفاعل يحقق ازالة بمقدار95.27% بعد ساعة من التشغيل و99.95% بعد ثلاث ساعات من التشغيل. ثم دراسة حركية التفاعل للتفاعل الضوئي ووجد ان قانون سرعة التفاعل من الدرجة الاولى بالنسبة لتركيز الصبغة وتطابق مع موديل Langmuir-Hinshelwood , كما وجدت علاقة تجريبية تربط بمعدل الازالة الصبغة مع المتغيرات التشغيلية.


Article
Experimental Study of Hybrid Solar Air Conditioning System in Iraq
دراسة تجريبية لنظام تكييف الهواء الشمسي الهجين في العراق

Authors: Raed Ayad Abduljabbar رائد اياد عبد الجبار --- Ahmed Abd Mohammed احمد عبد محمد
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2018 Volume: 24 Issue: 10 Pages: 32-48
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this paper, an experimental study of the thermal performance for hybrid solar air conditioning system was carried out, to investigate system suitability for the hot climate in Iraq. The system consists of vapor compression unit combined with evacuated tube solar collector and liquid storage tank. A three-way valve was installed after the compressor to control the direction flow of the refrigerant, either to the storage tank or directly to the condenser. The performance parameters were collected by data logger to display and record in the computer by using LabVIEW software. The results show that the average coefficient of performance of hybrid solar air conditioning system (R=1) was about 2.42 to 2.77 and the average power consumption was about 1.1 to 1.12 kW when the ambient temperature was about 34.2 to 39.7 ˚C, while the average coefficient of performance of conventional system (R=0) was about 3.23 and the average power consumption was about 1 kW when the ambient temperature was about 30.8 to 34.3 ˚C. It can be concluded that the use of the hybrid solar system in Iraq with its current form could not be saved electricity.

تم إجراء دراسة تجريبية لاختبار الأداء الحراري لنظام تكييف الهواء الشمسي الهجين ورؤية مدى ملائمته للاجواء الحارة في العراق. يتكون النظام من دورة بخار انضغاطية مدمجة مع مجمع شمسي من نوع الانابيب المفرغة بالاضافة الى خزان الماء الحار. تم تركيب صمام ثلاثي الاتجاه بعد الضاغط مباشرة للتحكم في اتجاه جريان مائع التثليج ، حيث يكون اتجاه جريان مائع التثليج اما باتجاه خزان الماء الحار (كما في النظام الهجين) أوباتجاه المكثف مباشرة (كما في النظام التقليدي). تم جمع معاملات الأداء بواسطة مسجل البيانات، وتم عرضها وتسجيلها في جهاز الحاسوب باستخدام برنامجLabView. أظهرت النتائج أن متوسط معامل أداء النظام الهجين (R=1) كان يتراوح ما بين 2.42 الى 2.77 ، وكان متوسط استهلاك الطاقة الكهربائية ما بين 1.1 إلى 1.12 كيلوواط عندما كانت درجة حرارة الهواء الخارجي ما بين 34.2 إلى 39.7 درجة مئوية، في حين أن متوسط معامل أداء النظام التقليدي(R=0)كان حوالي 3.23 ومتوسط استهلاك الطاقة الكهربائية حوالي 1 كيلوواط عندما كانت درجة حرارة الهواء الخارجي ما بين 30.8 إلى 34.3 درجة مئوية، لذلك فان استخدام النظام الهجين في العراق بشكله الحالي قد لا يوفر طاقة كهربائية.

Listing 1 - 5 of 5
Sort by
Narrow your search

Resource type

article (5)


Language

English (4)

Arabic and English (1)


Year
From To Submit

2018 (2)

2017 (1)

2015 (1)

2014 (1)