Life-Cycle Cost Analysis for Three Different Types of A/C Systems Applied on an Apartment Located in a Multi-Floors Residential Tower in Mosul City
تحليل كلفة العمر الافتراضي لثلاث منظومات مختلفة لتبريد وتكييف الهواء لشقة متواجدة في برج سكني متعدد الطوابق في مدينة الموصل

Author: Badran Mohammed Salim
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 9 Part (A) Engineering Pages: 2134-1147
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This research studies the life cycle cost analysis using detailed cooling and electrical load profiles to calculate initial and running costs to evaluate the economic feasibilities of three different types of air conditioning systems as residential air conditioning system (RACs), commercial air conditioning system (CACs) and multi power air conditioning system (MPACs). The present-worth cost method for life-cycle cost period for ten (10) years analysis is applied to a sample building located in Mosul city / Iraq so as to select the best air conditioning system. The cooling load temperature differential with cooling load factor (CLTD/CLF) was used with hourly analysis program (HAP v4.6) for the estimation cooling load in each room of apartment.The results showed that the RAC system is lower than CAC and MPAC systems in initial cost approximately 53% and 67% respectively and the running cost for CAC system is lower than RAC and MPAC systems approximately 12% and 7% respectively for one month. The the total cost for two systems RAC and CAC are equal after 20 months of the beginning run and after even break point (BEP) the total cost for CAC system began to decline which indicates there is save in electric consumption and present worth cost over a period of (10) ten years after operation interval. The CAC system uses duct always to distribute air into each condition zone, therefor this system gives less noise of air distribution with best interior aesthetic appearance so that it fits with the interior decoration for each rooms of apartment. The outdoor unit of CAC system doesn’t appearance because the system working for long distances and can put outdoor units on the roof of the building.

يتضمن البحث الحالي تحليل كلفة العمر الافتراضي لثلاث منظومات مختلفة لتبريد وتكييف الهواء وكانت على النحو التالي منظومة تبريد وتكييف منزلية ومنظومة تبريد وتكييف تجارية ومنظومة تبريد وتكييف متعددة الاحمال حيث تم دراسة الكلفة الاولية والكلفة التشغيلية للمنظومات المختلفة بالاعتماد على مخطط الاحمال الحرارية والاحمال الكهربائية لنموذج شقة سكنية تقع في برج متعدد الطوابق في مدينة الموصل / العراق ، تم أعتماد طريقة فرق درجات حرارة مع عامل تصحيح حمل التبريد (CLTD/CLF) وبرنامج تحليل الساعات (HAP) أصدار (4.6) من شركة كاريير لحساب احمال التبريد الخاصة بالشقة السكنية. تم ملاحظة أن منظومة التبريد والتكييف المنزلية (RACs) تكون كلفتها الاولية اقل بمقدار 53% عن منظومة التبريد والتكييف التجارية (CACs) و67% عن منظومة التبريد والتكييف متعددة الاحمال (MPACs) وأن الكلفة التشغيلية لمدة شهر واحد فقط لمنظومة التبريد والتكييف التجارية هي أقـل من منظومة التبريد والتكييف المنزلية ومنظومة التبريد والتكييف متعددة الاحمال بمقدار 7% و 12% على التوالي، كذلك تم استنتاج أن منظومة التبريد والتكييف التجارية هي أفضل من ناحية الكلفة الكلية (المتمثلة بالكلفة الاولية والتشغيلية) لمدة تشغيلية مقدارها (10) عشر سنوات وأنه بعد مرور ((20 شهر من التشغيل الاولي للمنظومات الثلاث سيحدث تطابق في قيم الكلف الكلية لمنظومتي التبريد والتكييف التجارية والمنزلية وبعد تجاوز نقطة التطابق (EBP) سيتم عمل منظومة التبريد والتكييف التجارية مع ربح من ناحية الكلفة التشغيلية على مدار السنوات المتعاقبة وهذا يمثل الربح في اختيار هذا النوع من المنظومات الثلاث، فضلا عن ان منظومة التبريد والتكييف التجارية تستخدم مجرى هوائي دائماً لتمرير الهواء من الوحدة الداخلية وصولاً الى الحيز المراد تكييفه وبالتالي سيتم التحكم من خلال تصميم المجرى الهوائي بمقدار الضوضاء التي يصدرها الهواء الخارج من موزع الهواء لكل حيز مع وجود تناسق كبير بين اشكال والوان موزعات الهواء التي ستكون ملائمة مع التصميم الداخلي لكل حيز. إن منظومة التبريد والتكييف التجارية (CACs) تعمل لمسافات طويلة وبذلك سيكون من السهل جداً وضع الوحدة الخارجية على سطح البرج السكني وبالتالي المحافظة على المظهر الخارجي للبرج السكني .


Article
Economic Feasibility Study of Modern and Conventional Central Heating Systems for Villa Located in Duhok City, Iraq

Authors: B.M. Salim --- I.F. Abdulqadir --- F.M. Younis
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2017 Volume: 35 Issue: 7 Part (A) Engineering Pages: 725-736
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This research includes the evaluation of economic feasibilities based on the Iraqi’s market cost by using three different types of central heating systems in a residential villa located in Duhok city / Iraq. It also compares between modern and conventional central heating systems. A life cycle cost analysis based on detailed heating and operation load profiles considered in this work. Initial, running and maintenance costs for three central heating systems examined for fifteen years as a working period. The used systems in this study were; modern central heating system (heat pump water heater system) and conventional central heating system (fuel oil hot water boiler system and electric hot water boiler system). Transfer function method with hourly analysis program platform (HAP4.9) used for estimation the heating loads within each zone of the project. The proposed technique of modern central heating system found to be more efficient for thermal and economic efficiencies and it uses an environmentally friendly refrigerant such as (R410A). It also works efficiently in severe cold climate with low temperature of (-20°C) in winter season. The results shows that the heat pump water heater central heating system is most efficient system, this system has provided an energy saving range up to 57.5% compared with electric hot water boiler system and 70.6% compared with fuel oil hot water boiler system.


Article
COMPARATIVE ANALYSIS BETWEEN MODERN AND CONVENTIONAL HVAC SYSTEMS FOR USE AT COMMERCIAL BUILDING IN BAGHDAD CITY / IRAQ
تحميل مقارن لمنظومات التبريد والتكييف الحديثة والتقليدية لبناية تجارية في مدينه بغداد / العراق

Authors: Dr. Nabil J. Yasin د.نبيل جميل ياسين --- Badran M. Salim بدران محمد سالم
Journal: AL-TAQANI مجلة التقني ISSN: 1818653X Year: 2017 Volume: 30 Issue: 6 Pages: E47-E63
Publisher: Foundation of technical education هيئة التعليم التقني

Loading...
Loading...
Abstract

This research use the life cycle cost analysis and a detailed cooling, heating and electrical load profiles to determine the initial, running and maintenance costs for evaluation the economic feasibilities of using three different types of central air conditioning systems in a commercial building located in Baghdad city / Iraq, so as to select the best air conditioning system. The systems were modern air conditioning system (variable refrigerant flow), all air conditioning system (package roof top unit) and all water air conditioning system (fan coil unit). The present-worth cost method for lifecycle cost period for fifteen years analysis is applied. The transfer function method was used with hourly analysis program (HAP v4.9) for estimation the cooling and heating loads in each space of the building with adopted the indoor air quality in the design as adequate fresh air per person, acceptable noise level and air quality. The comparison between the different methods for the total cost (during fifteen years) for air conditioning systems showed that the variable refrigerant flow system has lowest total cost compare with other methods used for the period operation, so as the variable refrigerant flow air conditioning system worked into variable cooling and heating load between 0% and 100% of total load.

يتضمن البحث الحالي اجراء تحميل لكمفة العمر الافتراضي وحسابات احمال التبريد والتدفئه بالاضافه الى الأحمال الكهربائية لتحديد الكلفه الاوليه وكلفه الصيانه وكلفة التشغيل لثلاث أنواع مختلفة من منظومات التكييف المركزيه التي تعمل في نموذج لبنايه تجاريه )مول( تقع في مدينه بغداد/العراق. المنظومات كانت عمى النحو التالي منظومة تبريد وتكييف هواء مركزية نوع هواء كمي ومنظومة تبريد وتكييف هواء مركزية نوع ماء كمي ومنظومة تبريد وتكييف هواء مركزية حديثة. تم اعتماد طريقة دالات التحويل مع برنامج ) HAP ( نسخة 4.9 لأيجاد احمال التبريد والتدفئة الخاصة بكل حيز من المول مع الاخذ بنظر الاعتبار توفير شروط جودة الهواء الداخلي ) IAQ ( التي تخص توفير هواء نقي لكل شخص ويكون الهواء المجهز ذو نقاوة جيدة بالاضافة الى توزيع الهواء بدون ضوضاء تؤثر عمى راحة الانسان في داخل الحيز المشغول ، من خلال مقارنة الكلفة الكمية لمنظومات التبريد والتكييف المركزية وخلال مدة تشغيلية قدرها خمسة عشر عام تبين ان الاختيار الامثل والمناسب لهذا المشروع هو منظومة تبريد وتكييف هواء مركزية حديثة ) VRF (لانها تعمل حفظ لمطاقة وبالتالي تكون صرفيات الطاقة أقل من المنظومات الاخرى فضلا عن عمل المنظومة بحمل جزئي للتبريد او التدفئة متغيير يترواح بين % 0 الى 100 % ..

Listing 1 - 3 of 3