research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Calculation the optical energy band gap of LR115 SSNTD irradiated by α particle
حساب طاقة الفجوة الضوئية لكواشف الأثر النووي LR115 المشععة بجسيمات الفا

Author: Hassan M.Jaber Al-Tai'i حسن مكطوف جبر الطائي
Journal: Iraqi Journal of Physics المجلة العراقية للفيزياء ISSN: 20704003 Year: 2013 Volume: 11 Issue: 22 Pages: 1-7
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The effect of α-particle irradiation on the optical absorption in nuclear track detectors (LR115) has been studied. These detectors have been irradiated with different doses. The optical absorption has been measured using the ultraviolet-visible (UV-1100) spectroscopy, that irradiation results in shifting the peaks of the optical absorption. The values of Urbach energy have been calculated from the position of steady-state optical band gap energy, for a standard sample which was unirradiated with indirect influence, has been found 1.9 eV whereas its value after irradiation 1.98 eV. In case of the direct influence, it is found to be, respectively, before irradiation 1.98 eV and after irradiation 2.05 eV. From these results, we can reveal that the values of energy gaps in direct–coincidence before and after irradiation greater than those for indirect one. The number of carbon atoms has been determined in each case for the optical energy gaps.

تمت دراسة تأثير التشعيع بجسيمات الفا على الامتصاصية الضوئية لكواشف الأثر النووي LR115. حيث شععت بجرعات مختلفة وتم قياس الامتصاصية الضوئية باستخدام جهازالمطيافية ( (UV- 1100وكانت نتيجة للتشعيع هو حصول إزاحة قليلة في قمم الامتصاصية الضوئية وكذلك تم حساب طاقة اورباخ من مناطق طاقة الفجوة وتم مقارنتها مع التأثير المباشر وغير المباشر للعينة القياسية، ووجد أن قيمة التأثير غير المباشر قبل التشعيع 1.9eV وبعد التشعيع 1.98eV وفي حالة التأثير المباشر كانت قبل وبعد التشعيع 1.98eV و2.05eV على التوالي. ومن هذه النتائج نجد ان قيمة طاقة الفجوة في حالة التأثير المباشر قبل وبعد التشعيع اكبر من حالة غير المباشرة، وأيضا تم حساب عدد ذرات الكاربون لطاقات الفجوة الضوئية في كلتا الحالتين.


Article
Determination of the Bulk Etch Rate of the Nuclear Track Detector LR-115
إيجاد معدل القشط العام لكاشف الأثر النووي LR-115

Loading...
Loading...
Abstract

The present paper aims to determine the bulk etch rate (VB) of the nuclear track detector LR115 type  using the track "length-diameter" (Le-D) measurement method. The detector was irradiated with energies 1.8, 2.47, 3.29 and 3.95 MeV of alpha particles under normal incidence. A 1Ci241Am source emits alpha particles with the main energy of 5.485 MeV was used in irradiation of the detector. The energies less than the main value are obtained by changing the source to detector distance in air at atmospheric pressure. The alpha-irradiated detectors were etched with a 2.5 N of NaOH solution at temperature 50±1oC, and then the track diameters were measured. Using an alternative method presented by Al-Nia'emi and the D-Le calibration method, the track lengths were determined from the directly measured track diameters for different etching times according to the energies of the alpha particles. It was found that the average value of VB was 1.1 m.h-1, which is not extremely dependent on the alpha particle energies. The result was compared to values recorded by other studies using different methods of measurement.

يهدف البحث إلى إيجاد معدل القشط العام VBلكاشف الأثر النووي LR115 type باستخدام طريقة قياس "طول-قطر" الأثر (Le-D). شعع الكاشف بجسيمات ألفا بسقوط عمودي بطاقات MeV1.8, 2.47, 3.29 & 3.95. اُستخدم مصدر 241Am(1 Ci)الباعث لجسيمات ألفا بطاقة رئيسة 5.485MeV في تشعيع الكاشف. تم الحصول على طاقات اقل من الطاقة الرئيسة بتغيير المسافة بين الكاشف والمصدر المشع في الهواء تحت الضغط الجوي الاعتيادي. قُشِطت الكواشف المشعّعة بالمحلول الكيميائي NaOH بتركيز 2.5N ودرجة حرارة 50±1oC، ثم قيست أقطار الآثار المتكونة. حُسِبت أطوال الآثار بالطريقة البديلة للـ Al-Nia'emi وطريقة معايرة الـ D-Leمن الأقطار التي تم قياسها مباشرة عند أزمان القشط المختلفة تبعاً لطاقات جسيمات ألفا. وُجِد أن معدل قيمة VB كانت 1.1 m h-1، وأنه لا يعتمد بشكل كبير على طاقة جسيمات ألفا. قورنت النتيجة مع القيم لدراسات أخرى اُستخدِمت فيها طرائق مختلفة في القياس.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic (1)

English (1)


Year
From To Submit

2018 (1)

2013 (1)