research centers


Search results: Found 45

Listing 1 - 10 of 45 << page
of 5
>>
Sort by

Article
Heterogeneously Catalyzed Esterification Reaction: Experimental and Modeling Using Langmuir- Hinshelwood Approach

Loading...
Loading...
Abstract

The esterification reaction of ethyl alcohol and acetic acid catalyzed by the ion exchange resin, Amberlyst 15, was investigated. The experimental study was implemented in an isothermal batch reactor. Catalyst loading, initial molar ratio, mixing time and temperature as being the most effective parameters, were extensively studied and discussed. A maximum final conversion of 75% was obtained at 70°C, acid to ethyl alcohol mole ratio of 1/2 and 10 g catalyst loading. Kinetic of the reaction was correlated with Langmuir-Hanshelwood model (LHM). The total rate constant and the adsorption equilibrium of water as a function of the temperature was calculated. The activation energies were found to be as 113876.9 and -49474.95 KJ per Kmol of acetic acid for the esterification reaction and the heat of adsorption of water. These results agreed well with the previous published data.


Article
Simple method for removal of cadmium ions (ІІ) From Industrial Wastewater Using Calcinated Porcellanite

Authors: Jameel M. Dhabab --- Kadhem A. Hussien
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2014 Volume: 22 Issue: 5 Pages: 1635-1648
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

A simple method is developed for the removal of cadmium ions from industrial wastewater. Batch process has been used with natural and calcinated Iraqi porcellanite as adsorbent. Experimental parameters were given, concentration cadmium ion 10-50 mg/L, pH from (2-10), time was 60 min and maximum adsorption was achieve at 30°C.The present study had indicated appositive relationship between the removal efficiency of Cadmium ions with the increasing weight of adsorbents. Adsorption process was pseudo second- order kinetics, and followed Langmuir isotherm model which gave a better fit to the experimental data in comparison with the Temkin and Freundlich equations.Thermodynamic studies of two different surfaces were also given and showed endothermic process.ΔH°, ΔG° and ΔS° values were measured and showed that adsorption is spontaneous.ΔH° was positive, while ΔG° was negative. ΔS° was increased and showed activity of surface for adsorption. X-RAY and FT-IR spectroscopy were used to prove that calcinated porcellanite was more efficient than natural porcellanite.

تهدف الدراسة إلى إيجاد طريقة بسيطة جديدة لإزالةِ أيونات الكادميومِ مِنْ مخلفات المياه الصناعية باستعمال البورسلينات العراقية الطبيعية والمكلسنة بنظام الوجبة . تم دراسة الظروف التجريبية لعملية الإزالة ( pH بحدود (2-10) , درجة الحرارة = 30 C° , زمن التماس = 60min , والتركيز الابتدائي لايونات الكادميوم ( 50 mg/L 10-) . أثبتت الدراسة وجود علاقة طردية بين النسبة المئوية لإزالة ايونات الكادميوم وزيادة وزن المادة المازة.دلت دراسة حركيات التفاعل إن عملية الامتزاز تتبع المرتبة الثانية الكاذبة. أثبتت الدراسة الايزوثيرمية إن نموذج لانكماير للايزوثيرم أكثر انطباقاً من نموذجي فراندليش وتمكن في كلا السطحين. بينت الدراسات الثرموديناميكية إن العملية ماصة للحرارة من قيم ΔH° الموجبة , وتلقائية من القيم السالبة لـ ΔG° , بينما دلت القيم الموجبة لـΔS° على زيادة العشوائية أو اللاانتظام لعملية الإزالة. استخدمت مطيافية الأشعة تحت الحمراء وتقنية حيود الأشعة السينية لتشخيص المجاميع الفعالة على السطح الماز المستخدم.


Article
Diagnostics of low-pressure capacitivelycoupled RF dischargeargon plasma
تشخيص التفريغ الكهربائي عند الضغط الواطئ لمنظومة الاقتران السعوي ذو الترددات الراديوية لبلازما الاركون

Loading...
Loading...
Abstract

Low-pressure capacitively coupled RF discharge Ar plasma has been studied using Langmuir probe. The electron temperature, electron density and Debay length were calculated under different pressures and electrode gap. In this work the RF Langmuir probe is designed using 4MHz filter as compensation circuit and I-V probe characteristic have been investigated. The pressure varied from 0.07 mbar to 0.1 mbar while electrode gap varied from 2-5 cm. The plasma was generated using power supply at 4MHz frequency with power 300 W. The flowmeter is used to control Argon gas flow in the range of 600 standard cubic centimeters per minute (sccm). The electron temperature drops slowly with pressure and it's gradually decreased when expanding the electrode gap.As the gas pressure increases, the plasma density rises slightly at low gas pressure while it drops little at higher gas pressure. The electron density decreases rapidly with expand distances between electrodes.

تم دراسة التفريغ الكهربائي لبلازما الاركون عند الضغط الواطئ لمنظومة الاقتران السعوي ذو الترددات الراديوية باستخدام مجس لانكمور. وكذلك تم حساب درجة حرارة الالكترون وكثافة الالكترون وطول ديباي مع اختلاف الضغوط والمسافة بين القطبين. في هذا العمل صمم مجس لانكمور ذو الترددات الراديوية باستخدام مرشح 4 ميكا هيرتز كدائرة تعويض وبحثت العلاقة بين الفولتية والتيار. تم تغيير الضغط من 0.07 الى 0.1 ملي بار بينما تم تغيير المسافة بين القطبين من 2 الى 5 سنتمتر. استخدم مجهز قدرة ذو تردد 4 ميكا هيرتز لتوليد البلازما بطاقة 300 واط. وكذلك استخدم مقياس التدفق بمدى 600 سنتمتر مكعب بالدقيقة للسيطرة على تدفق غاز الاركون.ووجد ان درجة حرارة الالكترون تتناقص مع زيادة الضغط وتتناقص ايضا مع زيادة المسافة بين الاقطاب بينما تتزايد كثافة الالكترون عند زيادة الضغط وتتناقص عند زيادة المسافة بين الاقطاب.


Article
Langmuir Probe Diagnostics of Low-Pressure Glow Discharge Plasma Using Argon-Nitrogen Mixtures
التشخيص باستخدام مجس لانجمور لبلازما التفريغ ذي الضغط الواطئ باستخدام خلائط غازي الاركون والنتروجين

Authors: Bahaa T. Chiad --- Oday A. Hammadi --- Firas J. Kadhim --- Mohammed K. Khalaf
Journal: Iraqi Journal of Applied Physics المجلة العراقية للفيزياء التطبيقية ISSN: 18132065 23091673 Year: 2016 Volume: 12 Issue: 3 Pages: 17-26
Publisher: iraqi society for alternative and renewable energy sources and techniques الجمعية العراقية لمصادر وتقنيات الطاقة البديلة والمستجدة

Loading...
Loading...
Abstract

In this work, experimental results on Langmuir probe diagnostics of low-pressure glow discharge plasma using argon-nitrogen mixtures are presented. The effect of variation in working pressure on the current-voltage characteristics of Langmuir probe diagnostics in unmagnetized glow-discharge plasma was introduced. The current-voltage characteristics of Langmuir probe diagnostics in glow-discharge plasma were studied at working pressure of 0.7mbar and three different cases (no magnetron, using one magnetron at the cathode, and using dual magnetrons). Similarly, the current-voltage characteristics of Langmuir probe in glow-discharge plasma at three different positions of the Langmuir probe inside plasma volume were presented. The variation of electron temperature and density in plasma with working gas pressure at the center point between the electrodes when dual magnetrons were used was determined. As well, the effect of mixing nitrogen with argon on the Langmuir probe characteristics at total working pressure of 0.7mbar and inter-electrode distance of 4cm was studied.


Article
Employment of Magnetron to Enhance Langmuir Probe Characteristics of Argon Glow Discharge Plasma in Sputtering System

Authors: Oday A. Hammadi --- Waleed N. Raja --- Mohammed A. Saleh --- Wisam A. Altun
Journal: Iraqi Journal of Applied Physics المجلة العراقية للفيزياء التطبيقية ISSN: 18132065 23091673 Year: 2016 Volume: 12 Issue: 4 Pages: 19-28
Publisher: iraqi society for alternative and renewable energy sources and techniques الجمعية العراقية لمصادر وتقنيات الطاقة البديلة والمستجدة

Loading...
Loading...
Abstract

In this study, the parameters affecting the Langmuir characteristics of a closed-field unbalanced magnetron plasma sputtering system were studied. These parameters include the effect of variation in working pressure on the current-voltage characteristics of Langmuir probe diagnostics in unmagnetized glow-discharge plasma. Also, the current-voltage characteristics of Langmuir probe diagnostics in glow-discharge plasma at working pressure of 0.7mbar and three different cases (no magnetron, using one magnetron at the cathode, and using dual magnetrons) were introduced. The current-voltage characteristics of Langmuir probe in glow-discharge plasma at three different positions of the Langmuir probe inside plasma volume were determined. The variation of electron temperature and density in plasma with working gas pressure was determined at the center point between the electrodes when dual magnetrons were used. Finally, the effect of mixing nitrogen with argon on the Langmuir probe characteristics at total working pressure of 0.7mbar and inter-electrode distance of 4cm was introduced.


Article
Removal Of Dissolved Cadmium Ions from Contaminated Wastewater using Raw Scrap Zero-Valent Iron And Zero Valent Aluminum as Locally Available and Inexpensive Sorbent Wastes
ازالة ايونات الكادميوم من مياه الفضلات الملوثة باستخدام مخلفات برادتي الحديد والالمنيوم الصفر التكافؤ كملوثات مازة متوفرة محليا ورخيصة

Authors: Hayder M. Rashid --- Ayad A.H. Faisal
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2018 Volume: 19 Issue: 4 Pages: 39-45
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The current study was to examine the reliability and effectiveness of using most abundant, inexpensive waste in the form of scrap raw zero valent aluminum ZVAI and zero valent iron ZVI for the capture, retard, and removal of one of the most serious and hazardous heavy metals cadmium dissolved in water. Batch tests were conducted to examine contact time (0-250) min, sorbent dose (0.25-1 g ZVAI/100 mL and 2-8 g ZVI/100 mL), initial pH (3-6), pollutant concentration of 50mg/L initially, and speed of agitation (0-250) rpm . Maximum contaminant removal efficiency corresponding to (90 %) for cadmium at 250 min contact time, 1g ZVAI/ 6g ZVI sorbent mass ratio, pH 5.5, pollutant concentration of 50 mg/L initially, and 250 rpm agitation speed were obtained. Langmuir and Freundlich isotherms were presumed to fit the batch kinetics data for the sorption of Cd(II) onto ZVAI and/or ZVI and found that Langmuir (I) was the most representative model type with coefficient of determination R2 greater than 0.9115. Kinetics data for the sorption of Cd(II) onto ZVAI/ZVI mixture and due to the good agreement between the fitted and the experimental results; the data was found to obey the pseudo second order model. The scanning electron microscopy (SEM) for the ZVI and ZVAI was conducted before and after the sorbent-liquid reaction and revealed distinct morphological changes in the sorbent surface due to the contaminant saturation and pore channel blockages that ceased the sorption process.

تقوم الدراسة الحالية على فحص مدى قابلية وفعالية استخدام مخلفات برادة الحديد والالمنيوم كفضلات متوفرة ورخيصة في اقتناص, اعاقة, وازالة اكثر العناصر الثقيلة خطورة وهو الكادميوم الذائب في الماء. لقد تم استخدام معالم تجريبية في اختبارات الوجبة مثل زمن تماس (0-250) دقيقة ،جرعة (0.25-1) غم برادة المنيوم و(2-8) غم برادة حديد 100مل من المحلول المائي الملوث، دالة حامضية (3-6)،تركيز بدلئي للملوث (50-200) mg/L وسرعة تقلّب (0-250) دورة في الدقيقة حيث تحققت 90% ازالة للكادميوم مقترنة بأفضل معالم تجريبية وهي زمن التماس (250) دقيقة ،جرعة ((1 غم برادة المنيوم و(6) غم برادة حديد 100مل من المحلول المائي الملوث، دالة حامضية (5.5)، تركيز ملوث بدائي ( (50 mg/L وسرعة تقلّب ( ( 250دورة في الدقيقة ومن خلال نتائج تجارب الوجبة تبيّن ان موديل لانكمير(I) هو افضل تمثيل لبيانات امتزاز الكادميوم على برادة الألمنيوم والحديد وبمعامل ارتباط اكبرمن 0.9115 وقد وجد ان بيانات حركيات التفاعل لامتزاز الكادميوم على خليط البرادتين وكنتيجة لمدى التقارب الحاصل بين النتائج النظرية والعملية تخضع لنموذج تفاعل الرتبة الثانية الكاذب حيث تكون الية الامتزاز الكيميائي هي المهيمنة على عملية الامتزاز. لقد تم اجراء الفحص المجهري لكل من برادة الحديد والالمنيوم قبل وبعد التفاعل بينها ةبين الكادميوم وقد لوحظ بان هنالك تغييرات سطحيه للمواد المازة نتيجة لتشبعها بالملوث وغلق قنواتها المسامية والتي كانت سبب في توقف عملية الامتزاز.

Keywords

Cadmium --- ZVI --- ZVAI --- Langmuir --- SEM --- Equilibrium


Article
Removal of organic matters from domestic wastewater by using adsorption technique

Authors: Layla Abdulkareem Mokif --- NoorAlaa Abdulhusain --- Hind Mufeed Jalil --- Jasim M.Salman
Journal: Mesopotamia Environmental Journal بيئة وادي الرافدين ISSN: 24102598 Year: 2018 Volume: 4 Issue: 4 Pages: 16-24
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

In this research a low cost material (Citrus aurantifolia) was used as adsorbent for removing of organic matter expressed as biological oxygen demand (BOD) from domestic wastewater. Batch experiments were used in this study under certain experimental conditions. The results showed that the maximum value of adsorption capacity of Citrus aurantifolia with BOD (13.5) mg/g. The maximum removal efficiency of BOD was (69.75%) at higher mass of adsorbent (5gm). The coefficient of determination values were higher for Freundlich than for Langmuir. Freundlich isotherm is better fitting isotherm for the experimental data with a correlation coefficient of 0.8806. The results demonstrated that the best contact time was (105 min.) and removal efficiency increases as contact time increase. The results revealed that the removal efficiency of BOD from wastewater increases when the amount of adsorbent increase.


Article
Characterization of Low-Pressure Argon and Nitrogen Discharge Plasmas Using Electrical Floating Probe Method

Authors: M.A.K. Ahmed --- A.S. Jasim --- K.I. Khaleel
Journal: Iraqi Journal of Applied Physics المجلة العراقية للفيزياء التطبيقية ISSN: 18132065 23091673 Year: 2013 Volume: 9 Issue: 3 Pages: 25-28
Publisher: iraqi society for alternative and renewable energy sources and techniques الجمعية العراقية لمصادر وتقنيات الطاقة البديلة والمستجدة

Loading...
Loading...
Abstract

In this work, a low-pressure dc-discharge plasma is characterized by electrical floating probe method. To get sufficient working conditions for plasma electrical probe, a sweep voltage power supply was built. The plasma generation chamber was used to produce glow-discharge using nitrogen and argon gases at pressures of 0.03, 0.07 and 0.1 mbar. The current-voltage characteristics were performed using plasma probe and some calculations, such as electron temperature, plasma frequency and plasma species density, were carried out. The results obtained from I-V curve showed that electron temperature for argon and nitrogen plasmas was increased by increasing gas pressure.


Article
Removal of Cadmium (II) Ion from Wastewater using Natural and Modified myrtus communis leaves

Authors: Jameel M. Dhabab --- Kadhem A. Hussien --- Hiend A. Abbas
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2014 Volume: 22 Issue: 3 Pages: 1119-1131
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

A new simple method was developed for the removal of cadmium ions from wastewater by using natural and modified dried leaves of myrtus communis .The effects of varying adsorbent weight, hydrogen ion concentration, contact time and temperature of adsorption were studied. Optimal conditions were obtained (pH was6, weight of adsorbent was2g, particle size was 300µm, temperature was25°c, contact time was 90 minute and concentration of cadmium ions was 10 mg/L). , in order to compare the results obtained from the natural and modification experiments. The result showed that the natural adsorbent gave about 78.12% removal for Cd(II) at a pH of 6.0 while KMnO4 modified adsorbent gave 98.06% removal for Cd(II) at the same conditions. The equilibrium data for the adsorption of cd(II) ion on myrtus communis leaves tested using the Freundlich,Temken and Langmuir adsorption isotherms. The Langmuir isotherm was observed more suitable for Cd(II) adsorption on natural myrtus communis leaves , while The Freundlich isotherm was found to be more suitable for Cd(II) adsorption on modified myrtus communis . To evaluate the mechanism of adsorption, pseudo-first order and second order kinetic models were used. The adsorption mechanism was found fit the second order. The thermodynamic parameters were given and showed that ΔH° was endothermic-positive value, ΔG° was found (a spontaneous process-negative value) and ΔS° was found positive value-in KMnO4 modified adsorbent while ΔH° was exothermic-negative value, ΔG° was found (a spontaneous process-negative value) and ΔS° was found negative value on natural myrtus communis. FTIR was used to identify the activity of adsorption process.

تهدف الدراسة إلى إيجاد طريقة بسيطة لإزالةِ أيونات الكادميومِ مِنْ مخلفات المياه الصناعية (التي تحوي معقدات الكادميوم) باستعمال مسحوق الأوراقِ المُجَفَّفةِ الطبيعيةِ والمعدلة من نبات الياس (Myrtus Communis). تم دراسة الظروف المثالية لعملية الإزالة ( pH=6 , وزن المادة المازة = 2gm , الحجم الحبيبي = 300µm , درجة الحرارة = 25 C° , زمن التماس = 90min , والتركيز الابتدائي لايونات الكادميوم = 10 mg/L ) . تم تطبيق هذه المعطيات على عيناتِ ذات تركيز (50 mg/L) وكانت كفاءة الإزالة بنسبة (78.12% ) باستخدام النبات الطبيعي وبنسبة (98.06%) باستخدام النبات المعدل بمحلول KMnO4. أثبتت الدراسة الايزوثيرمية انطباق نموذج Langmuir للايزوثيرم في حالة استخدام مسحوق النبات الطبيعي , لكن نموذجَ Freundlich كان الأكثر انطباقاً في النبات المعدل. دُرست حركيات التفاعل بتطبيق قانون المرتبة الأولى الكاذبة إضافة إلى قانون المرتبة الثانية للتفاعل ووُجد أن التفاعل من المرتبة الثانية. بينت الدراسات الثرموديناميكية إن العملية ماصة للحرارة من قيم ΔH° الموجبة , وتلقائية من القيم السالبة لـ ΔG° , بينما دلت القيم السالبة لـΔS° على زيادة العشوائية أو اللاانتظام لعملية الإزالة في حالة النبات الطبيعي بينما كانت العملية باعثة للحرارة في حالة النبات المعدل أو المحور. استخدمت مطيافية الأشعة تحت الحمراء لتشخيص المجاميع الفعالة على السطح الماز المستخدم.


Article
Purification of Aqueous Solution from Ni (II) Ions Using Commercial and Bitter Orange Leaves Activated Charcoal

Authors: Areej. A. Jarullah --- Mahasin. F. Alias --- Karim. H. Hassan
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2014 Volume: 17 Issue: 1 Pages: 32-40
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

The purification of diluted aqueous solution from toxic Ni (II) ion was investigated using commercial and bitter orange leaves activated charcoal as adsorbents through batch method. The contact times between the adsorbents and adsorbate at 298 K and pH of 5 were studied. The percentage metal removal approached equilibrium within 75 min on Commercial and 90 min on prepared charcoal surfaces. The experimental data of the metal removal equilibrium were correlated by either the Langmuir or Freundlich equations. Results indicate that the Langmuir model gave a better fit to the experimental data than the Freundlich equation. Kinetic processes of Ni2+ adsorption on Commercial and prepared charcoal were described by applying pseudo-first-order and pseudo-second-order rate equations which that the adsorption process obey pseudo-second-order rate equation.

يتناول البحث تنقية المحلول المائي من ايون النيكل الثنائي باستخدام الفحم المنشط التجاري والفحم المحضر من اوراق النارنج كسطوح امتزاز ودراسة زمن التماس بين المادة الممتزة وسطحي الامتزاز عند درجة حرارة 298 كلفن والدالة الحامضية 5 حيث بينت نتائج الدراسة ان النسبة المئوية لإزالة الفلز تصل الى حالة الاتزان عند 75 دقيقة على سطح الفحم التجاري و90 دقيقة على سطح الفحم المحضر. حللت ايزوثيرمات الامتزاز وفق نموذجي لانكماير و فريندلش اذ وجد ان ايزوثيرمات الامتزاز تتبع معادلة لانكماير. كما تضمن البحث دراسة حركية لإمتزاز ايون النيكل الثنائي على سطحي الفحم التجاري والمحضر بتطبيق معادلات المرتبة الاولى والثانية حيث اظهرت النتائج ان عملية الامتزاز تطيع قانون المرتبة الثانية بشكل افضل وبمعامل ارتباط 0.9992 للفحم التجاري و 0.9974 للفحم المحضر من اوراق النارنج.الكلمـات المفتاحيـة: الفحـم المنشـط، ايـون النيكـل، لانكمايرايزوثيرم، فريندلش ايزوثيرم.

Listing 1 - 10 of 45 << page
of 5
>>
Sort by
Narrow your search

Resource type

article (45)


Language

English (38)

Arabic and English (3)

Arabic (2)


Year
From To Submit

2020 (2)

2019 (3)

2018 (4)

2017 (5)

2016 (10)

More...