research centers


Search results: Found 269

Listing 1 - 10 of 269 << page
of 27
>>
Sort by

Article
Influence of Geogrid Reinforced Loose Sand In Transfer of Dynamic Loading To Underground Structure

Authors: Mohammed Y. Fattah --- Nahla M. Salim --- Mohammad S. Ismaiel
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2016 Volume: 34 Issue: 11 Part (A) Engineering Pages: 1915-1927
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Underground facilities are an integral part of the infrastructure of modern society and are used for a wide range of applications, including subways and railways, highways, material storage, and sewage and water transport. Underground facilities built in areas subject to dynamic activity must withstand both dynamic and static loading. This study focuses on the effect of the geogrid reinforcement in transfer of the dynamic load to the underground structure. The underground structure was simulated as a PVC pipe 110 mm in diameter inside the sandy soil. In order to investigate the response of soil, footing and underground tunnel to dynamic loading, a physical model was manufactured. The manufactured physical model could be used to simulate the application of dynamic loading. The total number of the tests carried out is 4 models. All the 4 model tests with relative density equal to 40% corresponding to loose sand. The applied harmonic load has an amplitude of 0.5 ton and a frequency of 2 Hz. For each amplitude and frequency of the load, the sand models were tested without geogrid and with geogrid of three series of geogrid depths from the model surface (0.5B, 1B and 1.5B) and width equal to (1B), where B is the strip footing width. The dynamic load was applied in the tests by a hydraulic jack system. The response of the tunnel to dynamic loading includes measuring the pressure above the crown of the tunnel by using a pressure cell (manufactured by Geokon company) as well as measuring the amplitude of displacement by using a vibration meter. The response of footing was elaborated by measuring the total settlement using sensors in the dynamic load apparatus. It was found the pressure above the crown of the tunnel decreased by about (14-33) % when using geogrid reinforcement. Also, it was found the settlement decreased by about (13-20) % when using geogrid reinforcement.

Keywords

Tunnel --- dynamic load --- geogrid --- load transfer


Article
Short Term Load Forecasting Based Artificial Neural Network

Author: Adel M. Dakhil
Journal: Iraqi Journal for Electrical And Electronic Engineering المجلة العراقية للهندسة الكهربائية والالكترونية ISSN: 18145892 Year: 2014 Volume: 10 Issue: 1 Pages: 42-47
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

Present study develops short term electric load forecasting using neural network; based on historical series of power demand the neural network chosen for this network is feed forward network, this neural network has five input variables ( hour of the day, the day of the week, the load for the previous hour, the load of the pervious day, the load for the previous week). Short term load forecast is very important due to accurate for power system operation and analysis system security among other mandatory function. The trained artificial neural network shows good accuracy and robust in forecasting future load demands for the daily operation, mean absolute percentage error (MAPE) was calculated and it is maximum value is 0.75% in load forecasting on Monday


Article
Cooling Load Calculations For Typical Iraqi Roof And Wall Constructions Using Ashrae's RTS Method
حسابات حمل التبريد لتركيبات سقوف وجدران نموذجية عراقية باستخدام نظرية RTS لاشري

Authors: Khalid Ahmed Joudi خالد أحمد جودي --- Ali Naser Hussien علي ناصر حسين
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2015 Volume: 21 Issue: 5 Pages: 98-114
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present work is an attempt to develop design data for an Iraqi roof and wall constructions using the latest ASHRAE Radiant Time Series (RTS) cooling load calculation method. The work involves calculation of cooling load theoretically by introducing the design data for Iraq, and verifies the results experimentally by field measurements. Technical specifications of Iraqi construction materials are used to derive the conduction time factors that needed in RTS method calculations. Special software published by Oklahoma state university is used to extract the conduction factors according to the technical specifications of Iraqi construction materials. Good agreement between the average theoretical and measured cooling load is obtained and the difference between them does not exceed 9.3%.

الدراسة الحالية هي محاولة لتقديم بيانات تصميمية لسقوف وجدران عراقية باستخدام أحدث الطرق المستخدمة من قبل جمعية اشري لحساب حمل التبريد وهي طريقة السلسلة الزمنية للإشعاع (RTS). يتضمن العمل حساب الحمل الحراري نظريا باستخدام ظروف العراق التصميمية, والتحقق منها بالقياسات العملية. تم استخدام المواصفات الفنية لمواد بناء عراقية لاشتقاق المعاملات الزمنية للتوصيل المطلوبة للعمليات الحسابية بطريقة (RTS). وقد استخدم برنامج خاص مصمم من قبل جامعة أوكلاهوما الأميركية لاستخراج المعاملات الزمنية للتوصيل وفقا للمواصفات الفنية لمواد البناء العراقية. وقد تم الحصول على توافق جيد بين معدل حمل التبريد المحسوب نظريا والمقاس عمليا ولم يتجاوز الفرق بينهما 9,3%.


Article
Feasibility Study of Power Saving Based on Using EMMEDUE M2 Building System

Author: Akram. W. Izzat
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2008 Volume: 14 Issue: 4 Pages: 3257-3267
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present work concentrates on the feasibility of the heat load reduction by utilizing some structural material with very poor heat conductivity as isolators for heat transmission. Average annular heating and cooling load is estimated for a typical building of certain area and design using ordinary structural material and EMMEDUE M2 building system. The basic element of the new structural material is made of a foam polystyrene core that is self extinguishing and chemically inert with varying density and thickness depending on panel type. The calculations are based on the average maximum and minimum monthly temperature in Baghdad. Building heating load could mainly depend on the average temperature difference per each daily hour per year, while building cooling load components are; direct solar radiation, transmission load, ventilation/infiltration load and internal load. Except the transmission load which depends on the same average temperature difference the other factors could be calculated separately.A reduction of 55% in the annual load is estimated per each house using the new building technology. For a district sums up 1000 houses of the new structural design the total saving of power will be 10.45 MW. The saving in heating and cooling cost is estimated based on capital cost of the diesel generation system and the fuel consumption cost. It has been concluded that the passive structural heat isolation is a very effective manner in countries like Iraq which has severe temperature differences between the summer and winter seasons.

يتركز البحث على مدى عملية تفليل الحمل الحراري بأستخدام مواد بناء ذات توصيل حراري ضعيف كمواد عازلة للأنتقال الحراري. تم تخمين معدل الحمل الحراري والتريد السنوي لبناية نموذجية ذات مساحة وتصميم معين بأستخدم مواد بناء عادية مقارنة بمادة بناء EMMEDUE M2. العنصر الأساسي في مادة البناء الجديدة مكونة من مادة البوليسترين الرغوية ذات قابلية الأطفاء التلقائي وغير الفعالة كيمياويا وبكثافات مختلفة وسمك يعتمد على نوع القطعة.تم بناء الحسابات على معدل القيم العليا والسفلى لدرجات الحرارة الشهرية في مدينة بغداد. يعتمد الحمل الحراري على معدلات فرق درجات الحرارة اليومية على مدار السنة بينما يعتمد حمل التبريد على: أشعة الشمس المباشرة¸ الحمل الأنتقالي, حمل التهوية, والحمل الداخلي. بأستثناء الحمل الأنتقالي الذي على نفس معدلات فروقات درجات الحرارة فأن بقية العوامل تحسب بشكل منفصل.تم تخمين مفدار النقصان في قيمة الحمل السنوي بقيمة مقدارها 55% لكل بناية يتم فيها أستخدام مواد البناء العازلة والمشار اليها في البحث. لحي سكني مكون من 1000 بناية مبنية من مادة البناء العازلة يكون مقدار الأدخار في طاثة التدفئة والتبريد 10.45 ميكاواط. تم حساب معدل الأدخار في كلفة التدقئة والتبريد بناءا على القيمة الفعالة لمنظومة التوليد وكلفة الوقود المتسخدم لمدة سنة. حيث تم الأستنتاج من البحث أن أستخدام مواد البناء العازلة في دول ذات مناخ قاري يكون ذا جدوى اقتصادية عالية جدا.


Article
Construction of Railway Track Using Asphalt – Ballast Layer
انشاء مسارات السكك الحدیدیھ باستخدام طبقات الحجر المكسر - الاسفلت

Author: Kawther.Y.H.AL-Soudany
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2012 Volume: 30 Issue: 3 Pages: 512-528
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The work presented in this paper focuses on new trends in the construction ofrail track using asphalt ballast layer. Model tests were performed with ballast layer150mm or 200mm. These thicknesses are the common range used in railwayconstruction. Overlaying a sandy layer 400mm in thickness. This conditionrepresents a case where rail networks pass through sandy zones.Two series of model tests were performed; the first on untreated ballast and thesecond where the ballast layer was incorporated with inter asphalt layers.A model footing 200mm wide and 400mm long was placed on the surface of theballast layer and loaded monotonically or repeatedly up to failure. Thesedimensions were selected representing the plain strain condition which exists inreal rail networks. The layers treated with asphalt demonstrated substantialimprovement in the load carrying capacity over the untreated layers.

ھذا العمل یسلط الضوء على اسالیب جدیده في تنفیذ تعلیة السكھ باستخدام طبقات الحجر المكسر– الاسفلت. نماذج الفحص نفذت بطبقھ حجر ذات سمك 150 مم او 200 مم تسند على طبقھ رملیھسمكھا 400 مم. أن الابعاد المستخدمة في ھذا البحث ھي الابعاد الشائعة الأستخدام في تنفیذ تعلیةالسكة وقد تم أستخدام التربة الرملیھ أسفل طبقة الحجر المكسر لتمثیل حالة مرورالسكة الحدیدیةعلى طبقة رملیة.تم تنفیذ مجموعتین من الفحوصات في المجموعھ الاولى تم استخدام الحجر وحده بدون معالجھبینما في المجموعھ الثانیھ تم معالجة طبقة الحجر باستخدام الاسفلت بوضع طبقھ من الاسفلت داخلالحجر.تم اُستخدام اساس عرضھ 200 مم وطولھ 400 مم وضع على سطح طبقة الحجر وتم تحمیلھ(Plain Strain) تدریجیا او تحمیل تكراري لحین الفشل. أن أختیار ھذه الابعاد جاء لتمثیل حالةللسكة الحدیدیة في الواقع. أن الطبقات المعالجھ بالاسفلت أعطت تحسین ملحوظ بقابلیة التحملمقارنھ مع الطبقات الغیر معالجھ.


Article
Performance Study of the Single and Double Stages Anaerobic Biological Filters in Treating Domestic Greywater
دراسة كفاءة المرشح البيولوجي اللاهوائي ذو المرحلة الواحدة وذو المرحلتين في معالجة المياه الرمادية المنزلية

Loading...
Loading...
Abstract

AbstractIn this paper, a laboratory plant was constructed and operated in order to assess the effect of stages; detention times and depth of filter on the performance of the upflow anaerobic biological filter that treating domestic grey water. The experimental plant was consisted of two upflow anaerobic filters; the first one operates with a single stage, while the second one was with two stages. Crushed gravels were used as a medium for growing the biological organisms. The two filters were worked simultaneously in continuous flow regime at hydraulic detention times of 12, 18 and 24 hours using greywater samples with COD concentration between 190-350 mg/l. The results showed that the two stages filter was more efficient than the single stage filter. The COD and BOD removals were (55.5, 62.7, 75.3)% and (57.2, 67.4, 78.2)% for the detention times of (12, 18 and 24) hours respectively. While the COD and BOD removals were (67.7, 54.8, 39.1)% and (73.2, 60.5, 44.8)% for the first filter and at the same detention times respectively. The two filters were also efficient in removing the suspended solids. Increasing depth of filter has a little influence on the performance efficiency. Depth of (0.3) m was considered the most effective height by which the quickest COD removal is performed.

الملخصتم في هذا البحث إنشاء وتشغيل محطة مختبريه لغرض دراسة تأثير مراحل الترشيح، وقت المكوث الهيدروليكي وعمق المرشح على سلوك وكفاءة المرشحات البيولوجية اللاهوائية ذات الجريان نحو الأعلى في معالجة المياه الرمادية المنزلية. اشتملت المحطة الاختبارية على مرشحين بيولوجيين الأول ذو مرحلـة واحـدة والثاني ذو المرحلتين حيث استخدم الـحصى المكسر كوسط لنمو الأحياء المجهرية. تم تشغيل المرشحين وفقاً لنظام التغذية المستمرة باستخدام نماذج مياه رمادية منزلية ذات تراكيز COD تراوحت ما بين (190-350) ملغم/لتر وبأوقات مكوث هيدروليكية قدرها 24 و18 و12 ساعة. أظهرت النتائج تفوق المرشح البيولوجي اللاهوائي ذو المرحلتين خصوصا عند زيادة الحمل الهيدروليكي والعضوي المسلط. إذ بلغت نسبة إزالة كل من COD و BOD في المرشح البيولوجي ذو المرحلتين (75.3 ، 62.7 ، 55.5)% و (78.2 ، 67.4 ، 57.2)% عند أوقات مكوث (24 و18 و12) ساعة على التوالي. في حين كانت نسبة إزالة الـ COD والـ BOD في المرشح البيولوجي اللاهوائي الأول (67.7 ، 54.8 ، 39.1)% و (73.2 ، 60.5 ، 44.8)% وعند نفس أوقات المكوث وعلى التوالي. كذلك أظهرت النتائج كفاءة هذه المرشحات في إزالة المواد الصلبة العالقة. كما أثبتت النتائج أن ارتفاع المرشح البيولوجي لا يعد عاملا مؤثرا حيث لوحظ بان أسرع إزالة COD تحدث عند ارتفاع (0.3) متر.


Article
A Correlation Between Dynamic and Static Pile Load Test Results
مقارنة بين نتائج فحص الركائز الستاتيكي والديناميكي

Authors: Kais T. Shlash --- Hussein H. Hussein
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2009 Volume: 27 Issue: 15 Pages: 2730-2737
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Three selected bored piles executed at Basrah area were tested both bystatic and dynamic pile test procedures in order to correlate their results when evaluating the piles capacities. The correlation showed that the results are close to each other in terms of load- settlement relations, but on the other hand, end bearing capacity and skin friction values obtained by the dynamics tests are far from the real behavior of piles. The reason may be due to lack of experience ofcrew that supervises the dynamic tests. They have to practice more dynamic tests and should build accumulated knowledge about the dynamic method of testing piles. The time is still early for the dynamic tests to replace the classical static test when evaluating piles capacities.

تم فحص عدد من الركائز المختارة بطريقتي التحميل الستاتيكي التقليدية والطريقة الديناميكية في محاولة لربط نتائج الفحص بالطريقتين و دراسة امكانية الاعتماد على فحص الركائز بالطريقة الديناميكية دون اللجوء الى فحص التحميل الستاتيكي المعمول به حاليا. وجد من خلال المقارنة بين نتائج الفحص بالطريقتين ان هناك تقارب جيد بين الطريقتين من حيث شكل العلاقة بين الحمل و الهبوط و لكن قيم مقاومة الاحتكاك و مقاومة بهاية الركيزة التي تسجلها الطريقة الديناميكية تختلف كثيرا عن تلك المحسوبة على ضوء خواص التربة المنفذة خلالها الركائز. قد يكون السبب في ذلك هو عدم كفاءة الفاحصين في تنفيذ الفحص و خاصة موضوع ادخال بعض المتغيرات الواجب تغذيتها الى برنامج الفحص الديناميكي وعليه يحتاج الفاحصون بالطريقة الديناميكية الىممارسة وجهد اكبر لغرض الالمام قبل اعتماد الطريقة الديناميكية في تقرير تحمل الركائز. على ضوء النتائج التي تم الحصول عليها يمكن القول بان احلال الفحص الديناميكي بدل الفحص الستاتيكي التقليدي امر يحتاج الى مزيد من الخبرة و الدراسة قبل اعتماده في العراق


Article
Developing Annual Load Duration Curve Using an Intelligent Technique
استحصال منحنى فترة الحمل السنوي باستخدام الطرق الذكية

Loading...
Loading...
Abstract

AbstractThe paper discusses a method to get the hourly load data from the peak daily load (i.e. to store one value and get 24 values). The method uses one of the intelligent techniques (Artificial Neural Network ANN). The annual load duration (ALDC) is used in different studies, such as power system planning, reliability study . . . etc. In this work the ALDC is used as an example for the application of the proposed method. When the hourly load data for a year are available, it is easy to find the ALDC. In the studies where the ALDC is needed, the load is usually forecasted (future load) where the hourly data are not available. A proposed ANN is explained to overcome this difficulty. The method develops the daily load (24 hours) from the peak load. The required days are encountered, which means that the ALDC is obtained for the required days. Also if there is a missing period, the proposed method can develop that missing period in the data. The data of the Iraqi North Region National Grid (INRNG) for the year 2001 is used to verify the validity of the proposed method. The results of a conventional method are also given.Key words: ALDC, Daily load, Hourly load, ANN.

الخلاصة يناقش هذا البحث طريقة جديدة للحصول على قيم الحمل لساعات اليوم من ذروة الحمل اليومي،أي أنه بخزن قيمة واحدة يتم الحصول على 24 قيمة. تستخدم الطريقة المقترحة احدى التقنيات الذكية وهي الشبكات العصبية الآصطناعية. يستخدم منحنى فترة الحمل السنوي في دراسات مختلفة مثل تخطيط المنظومة الكهربائية، دراسات الموثوقية، وحسابات كلفة الطاقة . . . الخ. عند توفر قيم احمال ساعات السنة يكون من السهل الحصول على منحنى فترة الحمل السنوي ، ولكن تقتضي الحاجة في مثل هذه التطبيقات الى تخمين قيم الأحمال لفترات مستقبلية حيث لاتتوفر فيها أحمال الساعات. تتغلب الطريقة المقترحة على هذه المشكلة وذلك بالحصول على قيم أحمال ساعات اليوم من قيم ذروة الحمل لذلك اليوم. من الممكن اختيار الايام المطلوبة واستخراج فترة الحمل لها. تم استخدام بيانات الحمل للشبكة الكهربائية الوطنية الشمالية للسنة 2001 وذلك لتحقيق نتائج الطريقة المقترحة. وقد اعطيت النتائج المستحصلة بالطريقة التقليدية والطريقة المقترحة.


Article
Exponential Based Load Model for Baghdad Distribution Feeder
تمثيل الاحمال بنموذج ذو صيغة أسية لشبكة مغذي

Author: Azhar M. Al-Rawi أزهر مجيد عبد الحميد الراوي
Journal: Al-Ma'mon College Journal مجلة كلية المامون ISSN: 19924453 Year: 2013 Issue: 21 Pages: 203-211
Publisher: AlMamon University College كلية المامون الجامعة

Loading...
Loading...
Abstract

Distribution feeders in Baghdad comprise different load classes, those classes differ in load component, characteristics and sensitivity to network variables. In view of this fact, applying any dynamic study to those feeders requires proper modeling of loads, otherwise, unfavorable results obtained. Realistic load component varies in relation to both system voltage and frequency, and this variation is related to load type and sensitivity, that may alter studies by deliveringnon -desired results. Proper modeling leads to desirable decisions,correct and realistic results, and undoubtedly will reduce efforts and expense of the un-justified network modifications. In this work, residential load mix feederisstudied,the load characteristic is acquired, and thennetwork componentsand loads are presented using voltage-frequency dependable exponential load model. The results obtained arerecommended to be implemented in distribution network studies and dedicated software within Baghdad network.

تتضمن مغذيات شبكة توزيع كهرباء بغداد أنواعاً متنوعة من الاحمال تختلف عن بعضها بالسلوك والخصائص والحساسية لمتغيرات النظام . ان تنفيذ اية دراسات واقعية على هذه المغذيات يتطلب التمثيل الامثل للاحمال وبخلافه تنتج هذه الدراسات نتائج غير مثالية.تتغير الاحمال الواقعية عند تذبذب الفولتية وتردد النظام ويعتمد هذا التغير على نوع الحمل وحساسيته ومن الممكن ان يؤثر في الدراسات الديناميكية لانظمة التوزيع. ان التمثيل الامثل للاحمال يقود لقرارات مثلى ونتائج واقعية صحيحة وبالتاكيد يقلل من كلفة التطوير والتنمية غير المبررة للشبكات في حال تمثلها بشكل ثابت.تضمن هذا البحث دراسة نموذج لمغذي ذي حمل سكني ,حيث تم تسجيل خصائص الحمل ومن ثم تمثيله باستخدام نموذج أسي مع الاخذ بنظر الاعتبار تاثير تغير الفولتية والتردد على تلك الاحمال , وخرجت هذه الدراسة بنتائج واقعية يوصى باستخدامها في دراسات شبكة توزيع كهرباء بغداد وبرامجياتها.


Article
VALIDATION OF DERIVED EQUATION USING ENERGY TECHNIQUE FOR CALCULATING THE CRITICAL BUCKLING LOAD FOR INTERMEDIATE AND LONG COLUMNS
اثبات صحة معادلة مشتقة باستخدام تقنية الطاقة لحساب حمل الانبعاج الحرج للاعمدة المتوسطة الطول و الطويلة

Authors: Ahmed Naif Al-Khazaraji --- Samir Ali Al-Rabii --- Hameed Shamkhi Al-Khazaali
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2016 Volume: 20 Issue: 4 Pages: 217-237
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

A new equation has been derived using energy technique (dummy load method) to describe the buckling behavior of intermediate and long columns under dynamic buckling loads compression load and under dynamic combined load with consider of the initial imperfections of the columns and the effect of eccentricity. The results of this equation are compared with the experimentally results of 40 specimens of AISI 303 stainless steel intermediate and long columns tested under dynamic compression loading (compression and torsion) and under dynamic combined loading (compression, bending, and torsion) by using a rotating buckling test machine, and it be found that the derived equation may be used to predict of the theoretical critical buckling load (

تم في هذا البحث اشتقاق معادلة لوصف سلوك الانبعاج الديناميكي للاعمدة المتوسطة الطول والطويلة تحت تأثير حمل الانضغاط الديناميكي والحمل الديناميكي المركب بأستخدام تقنية الطاقة مع الاخذ بنظر الاعتبار تأثير كل من الانحراف الاولي للعمود وتأثير اللامحورية في تسليط حمل الانضغاط. النتائج النظرية لحمل الانبعاج الحرج من هذه المعادلة تم مقارنتها مع النتائج العملية لحمل الانبعاج الحرج والتي تم الحصول عليها بفحص 40 عينة من اعمدة الصلب المقاوم للصدأ AISI 303 الطويلة والمتوسطة الطول وتحت تأثيركل من حمل الانضغاط الديناميكي )حمل ضغط محوري زائد حمل التواء( والحمل الديناميكي المركب )حمل ضغط محوري وحمل انحناء زائد حمل التواء(، حيث وجد ان المعادلة المشتقة يمكن ان تستخدم للتنبؤ بمقدار حمل الانبعاج النظري للاعمدة تحت تأثير حمل الانضغاط الديناميكي والحمل الديناميكي المركب وبأعلى نسبة مئوية للخطأ 19.3 % و 16.8 % على التوالي

Listing 1 - 10 of 269 << page
of 27
>>
Sort by
Narrow your search

Resource type

article (269)


Language

English (224)

Arabic (21)

Arabic and English (19)


Year
From To Submit

2019 (10)

2018 (30)

2017 (39)

2016 (26)

2015 (26)

More...