research centers


Search results: Found 3

Listing 1 - 3 of 3
Sort by

Article
Effect of Using Well Water as Mixing Waterin Concrete
تأثير استخدام مياه الابار كماء للخلط في الخرسانة

Authors: I. H. Hassan ابتسام حازم حسن --- O. M. Abdul-Kareem عمر محمد عبد الكريم --- A. Y. Shihab أحمد ياسين شهاب
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2014 Volume: 22 Issue: 5 Pages: 166-177
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

Water quality has been a matter of concern in civil engineering projects.Most specifications require the use of potable water because its chemical composition is known and well regulated. In some situations where potable water is not ready available, many water types which are unacceptable for drinking may be satisfactorily used in concrete, such as the well water. In this study, Well water is being investigated the feasibility of using well water as a mixing water in concrete. Water samples were obtained from three different wells. The chemical properties of these samples were investigated in the laboratory. Eight mixes were prepared from two types of cement (ordinary and sulfate resisting Portland cements) and these samples of well water as well as distilled water in order to make a comparative study. The concrete specimens were cured and tested for compressive,splitting tensile and flexural strengths at(3, 7, 28) days. The results, when compared with the results of control mixes (made with distilled water), showed that same effect of well water on the concrete strengths approximately. Therefore, the well water with acceptable limits in its chemical analysiswas suitable for use in production of concrete with acceptable strength.

تعتبر نوعية الماء من الامور المهمة التي لها علاقة بمشاريع الهندسة المدنية. إذ أن اغلب المواصفات تتطلب استخدام ماء الشرب بسبب تركيبه الكيميائي المعروف والمنتظم بشكل جيد. في بعض المواقع عندما لايكون ماء الشرب متوفراً وجاهزاً للاستخدام فإن الكثير من انواع الماء غير الصالحة للشرب من الممكن أن يكون استخدامها ملائماً للخرسانة كما هو الحال في مياه الابار. في هذه الدراسة يتم التحقق من مدى ملائمة استخدام مياه الابار كماء للخلط في الخرسانة. تم أخذ عينات الماء من ثلاثة ابار مختلفةوقد أجري تحليلها كيميائياً في المختبر كما تم تحضير ثمان خلطات خرسانية من نوعين من السمنت (سمنت اعتيادي وسمنت بورتلاند مقاوم للكبريتات) مع عينات مياه الابار اضافة الى الماء المقطر. وقد تمت معالجة النماذج الخرسانية وفحص مقاومة انضغاطها ومقاومة الشد الانشطاري ومقاومة الانثناء عند الاعمار(3، 7، 28) يوماً. أظهرت النتائج بعد مقارنتها بنتائج الخلطة المرجعية (المحضرة من الماء المقطر). أظهرت تأثيراً مشابهاً لمياه الابار على مقاومات الخرسانة وبشكل تقريبي. لذلك فإن مياه الابار ذات الحدود المقبولة في تحليلها الكيميائي تعتبر مناسبة للاستخدام في انتاج خرسانة بمقاومة مقبولة.


Article
INFLUENCE OF WATER SOURCE ON COMPRESSIVE STRENGTH OF HIGH STRENGTH CONCRETE
تاثير نوعية الماء على خواص الكونكريت عالي المقاومة

Authors: Shatha Deyaa Mohammed شذى ضياء محمد --- Nawar Omran Ali نوار عمران علي --- Rawaa Khalid Aboud رواء خالد عبود
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2017 Volume: 10 Issue: 1 Pages: 31-38
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

This research studies the influence of water source on the compressive strength of high strength concrete. Four types of water source were adopted in both mixing and curing process these are river, tap, well and drainage water (all from Iraq-Diyala governorate). Chemical analysis was carried out for all types of the used water including (pH, total dissolved solids (TDS), Turbidity, chloride, total suspended solid (TSS), and sulfates). Depending on the chemical analysis results, it was found that for all adopted sources the chemical compositions was within the ASTM C 1602/C 1602M-04 limits and can be satisfactorily used in concrete mixtures.Mixture of high strength concrete for compressive strength of (60 MPa) was designed and checked using water-to-cement ratio of 0.37, 400.5 kg cement with 10% replacement of SF (Silica Fume), 607 kg sand, 1147 kg gravel and 0.85 lit /100 kg of cement of SP (Supper Plasticizer). Five ages were adopted to measure the compressive strength these are (7, 14, 28, 60, 90 and 120) days. The results indicated that the strength of concrete at different ages was affected by the adopted water source especially on the period (28-90) days. There was a reduction on the compressive strength varies between (8.5-3) % and (3-1.5) % for both river and well water source which is belong to the effect of chlorides.

يدرس هذا البحث تاثير مصدر الماء على مقاومة الكونكريت عالي المقاومة. استخدام اربع انواع من مصادر الماء في عملية صب الكونكريت وانضاجه هي ماء النهر, ماء الشرب, ماء البئر و ماء البزل (جميعها اخذت من محافظة ديالى في العراق). تم اجراء التحليل الكيميائي لكل نوع من انواع مصادر الماء المعتمدة في الدراسة واشتمل التحليل اجراء فحوصات (الحامضية, المواد الصلبة المذابة, العكرة, الكلوريد , نسبة المواد الصلبة العالقة و الكبريتات) وبالاعتماد على نتائج هذه الفحوصات الكيميائية وجد بان كافة مصادر الماء المعتمدة في البحث مطابقة لمتطلبات المدونة الامريكية الخاصة بخواص الماء المستخدم في انتاج الكونكريت (ASTM C 1602/C 1602M-04 ).صممت ودققت الخلطة الخاصة بانتاج كونكريت عالي المقاومة (60 MPa) باعتماد نسبة سمنت/ماء مقدارها (0.37) وبتسب خلط مقدارها 400.5 كغم سمنت وبنسبة استبدال من السليكا فيوم 10%, 607 كغم من الرمل , 1147 كغم من الحصى و 0.85 لتر من الملدن لكل 100 كغم من السمت. تم اعتماد خمسة اعمار لفحص مقاومة الانضغاط هي( 120,90,60,28,14,7) يوم.أظهرت النتائج تاثر مقاومة الكونكريت في اعمار مختلفة بنوعية الماء المستخدم في عمليتي الصب والانضاج خاصة للفترة بين ( 28-90) يوم. اذ انخفضت مقاومة الانضغاط بنسبة تتراوح بين (3-8.5) % و (3-1.5) % لكل من ماء النهر والبئر بسبب تاثير الكلورايد


Article
Estimation of fresh concrete temperature
تخمين درجة حرارة الصب للخرسانة الطرية

Author: Adil Mahdi Jabbar عادل مهدي جابر
Journal: Wasit Journal of Engineering Sciences مجلة واسط للعلوم الهندسية ISSN: 23056932 Year: 2017 Volume: 5 Issue: 2 Pages: 55-63
Publisher: Wassit University جامعة واسط

Loading...
Loading...
Abstract

ACI Committee 305 R proposed an equation for estimating temperature of fresh concrete with ice or without ice. Upon using the equation, it is shown that it is inaccurate. When using ice in percentage greater than 50 % of the mixing water , that equation gives irrational results. Also, ACI Equation under-estimates the actual temperature and it can be used with a little accuracy when using ice as a percentage of added mixing waterat 20 % and lower. For more accuracy and rational results and at different percentages of ice to replace mixing water, an experimental test and theoretical analysis have led to a more accurate equation for estimating fresh concrete temperature.

جنة ( 305R) في معهد الخرسانة الأمريكي (ACI) اقترحت معادلة لتخمين درجة حرارة الخرسانة الطرية عند استعمال الثلج لتعويض ماء الخلط أو بدونه . عند استعمال هذه المعادلة تبين أنهاغير دقيقة حيث عند استعمال الثلج بنسبة اكبر من 50% منماء الخلط تعطي هذه المعادلة نتائج غير منطقية . كذلك فإنهاتعطي نتائج اقل من نتائج درجات الحرارة الطبيعية للخرسانة الطرية، و يمكن استعمالها بدقة قليلةةبسنبطلخلاءامضوعييذلاجلثلانوكيامدنع20% أو اقل.و لغرض الحصول على نتائج أكثردقة و منطقية عند استعمال الثلج الذي يعوض ماء الخلط بنسب مختلفة ، تم إجراءيذلاوجذامنليرظنليلحتوةيلمعتارابتخاأدىإلىاقتراح معادلة أكثردقة لتخمين درجة حرارة الخرسانة الطرية

Listing 1 - 3 of 3
Sort by
Narrow your search

Resource type

article (3)


Language

English (3)


Year
From To Submit

2017 (2)