Article
Evaluation of Compressive Strength by Non- Destructive Test Using Ultrasonic Pulse Velocity With Maximum Size Aggregate (10 And 20)mm
تقييم مقاومة الخرسانة بطريقة الفحص اللا إتلافي للموجات فوق الصوتية باستخدام المقاس الأقصى للركام (10 و 20 ) مم

Authors: Laith A. Al-jaberi ليث عبد الباري الجابري --- Asmaa Mahdi Ali Asmaa Mahdi Ali أسماء مهدي علي
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2014 Volume: 18 Issue: 3 Pages: 208-222
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The concrete is tested non destructively to determine its mechanical properties (compressive strength) which is considered as the main property and the parameter used in its evaluation. This research aims to establish a fairly accurate relation between the ultrasonic pulse velocity and the concrete strength. The concrete was poured in the moulds [(30) cubes of size (150X 150X150)mm] are used to test ultrasonic pulse velocity for each size 10mm and 20mm coarse aggregate. The samples tested by ultrasonic test with direct ultrasonic pulse velocity (DUP) for each sample. The results obtained from the experimental work are analysed and studied by using statistica software. An empirical mathematical equation is derived by using statistic software program. In this paper the effect of maximum size of aggregate (20mm and 10mm) size on the result of ultrasonic pulse velocity.

تم فحص للخرسانة الفحص اللا إتلافي لتحديد الخواص الميكانيكية ( فحص مقاومة الانضغاط) حيث يعتبر من أهم الخواص للخرسانة . ويهدف هذا البحث لتخمين العلاقة مابين فحص الموجات فوق الصوتية وفحص المقاومة للخرسانة باستعمال مقاس مختلف من الركام الخشن (10مم و20 مم) ،حيث تم صب (30 نموذج) من المكعبات بإبعاد (150×150×150مم) وتم فحص الموجات فوق الصوتية و فحص مقاومة الانضغاط للنماذج وتحليل النتائج باستخدام برنامج الإحصائي statistica software .واستنادا إلى النتائج لوحظ إن مقاومة الانضغاط للنماذج باستخدام ركام خشن ذو مقاس 20مم اقل من مقاومة الانضغاط للنماذج باستعمال ركام خشن ذو مقاس 10 مم وذلك بسبب المناطق الضعف مابين عجينة السمنت وحبيبات الركام الخشن مما يؤدي إلى تقليل مقاومة الانضغاط .


Article
Predicting Mechanical Properties of High Performance Concrete by Using Non-destructive Tests
التنبؤ بالخواص الميكانيكية للخرسانة عالية الأداء بإستخدام الفحوصات اللاإتلافية

Authors: Sura F. Al-Khafaji --- Waleed A. Al-Qaisi --- Shakir A. Al-Mishhadani
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2009 Volume: 27 Issue: 3 Pages: 425-444
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In this study, high performance concrete mixes were produced by using highrange water reducing agent and also by using 10% silica fume or 10% highreactivity metakaolin as a partial replacement by weight of cement. Three cementcontents (350, 450, and 550) kg/m3 were used through this study. A total of 330(100 mm) cubes, 132 (100×200 mm) cylinders, 132 (100×100×400 mm) prisms,and 66 (150×300 mm) cylinders were casted and cured to the required age of test .All specimens were cured in tap water except 165 cubes, which were submerged inCl ˉ + SO4ˉ ˉ solution at concentration identical to those present in severeaggressive environment to study the effect of this solution on the compressivestrength of high performance concrete mixes. Compressive strength, splittingtensile strength, modulus of rupture, static modulus, rebound number, ultrasonicpulse velocity, dynamic modulus, initial surface absorption, density ,and totalabsorption tests were investigated for all mixes at 7, 28, 90, and 120 days age.Results of the destructive tests (compressive tensile strength, strength, splittingmodulus of rupture, and static modulus) and non–destructive tests (hammer,ultrasonic pulse velocity, and dynamic modulus) are statistically analyzed by usingSPSS Ver.15 software to study the possibility of predicting the mechanicalproperties of high performance concrete by using non–destructive tests. Simple andmultiple linear regression analysis of the obtained results leads to the proposedstatistical models for evaluating the compressive strength, splitting tensilestrength, modulus of rupture, and static modulus by using one or two or three ofthe above mentioned non–destructive tests. Analysis of variance (ANOVA)and t–test was also used to investigate the adequacy of the statistical models.

تم في هذه الدراسة انتاج خلطات خرسانية عالية الاداء باستخدام مضاف مقلل للماء بدرجة متفوقةوكذلك باستخدام ابخرة السليكا المكثفة بنسبة ١% او الميتاكاؤولين عالي الفعالية بنسبة ١% كتعويضعن جزء من وزن الاسمنت ، كما و تم استخدام ثلاث محتويات من السمنت 426٤٥٠،٣٥٠ و ٥٥٠ ) كغم/م ٣. تم صب و تهيئة ٣٣٠ مكعب بابعاد ( ١٠٠ ملم) ، ١٣٢ اسطوانة )٤٠٠ ملم ) و ٦٦ اسطوانة بابعاد ×١٠٠× ٢٠٠ ملم) ، ١٣٢ موشور بابعاد ( ١٠٠ × بابعاد ( ١٠٠٣٠٠ ملم) و قد عولجت جميعها بالماء لغاية عمر الفحص المطلوب ما عدا ١٦٥ مكعب تم ×١٥٠)غمرها جزئياً في محلول الكلوريدات و الكبريتات بتراكيز مماثلة لتلك الموجودة في ظروف بيئيةقاسية لدراسة تأثير هذا المحلول على مقاومة الانضغاط للخلطات الخرسانية العالية الاداء .اجريت فحوصات مقاومة الانضغاط ، مقاومة الشد الانفلاقي ، مقاومة الانثناء ، معامل المرونةالاستاتيكي ، رقم الارتداد، سرعة الموجات فوق الصوتية، معامل المرونة الديناميكي ، فحصالامتصاص السطحي الاولي ، الكثافة ، وفحص الامتصاص الكلي باعمار ١٢٠،٩٠،٢٨،٧ يوم .تم تحليل نتائج الفحوص ات الإتلافية (مقاومة الانضغاط ، مقاومة الشد الانفلاقي ، مقاومة الانثناء، ومعامل المرونة الاستاتيكي ) و اللاإتلافية (رقم الارتداد، سرعةالموجات فوق الصوتية، معامللدراسة امكانية التنبؤ بالخواص (SPSS Ver. المرونة الديناميكي) احصائياً باستخدام برنامج ( 15الميكانيكية لخرسانة عالية الاداء باستخدام الفحوصات اللاإتلافية . التحليل الانحداري البسيطوالمتعدد الخطي للنتائج المستحصلة ادى الى النماذج الاحصائية المقترحة لتقييم الخواصالميكانيكية باستخدام فحص واحد او فحصين او ثلاثة من الفحوصات اللاإتلافية . كذلك تم استخداملتحري كفاءة النماذج الاحصائية. (t-test) و (ANOVA) تحليل التباين


Article
COMPRSSIVE STRENGTH MODEL FOR CONCRETE CONTAINING POLYETHYLENE TEREPHTHALATE(PET) BY USING ULTRASONIC PULSE VELOCITY

Authors: Rasha Jasim --- Mohammed Qasim
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2017 Volume: 10 Issue: 4 Pages: 384-396
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

This research proposed a model describing the relationship between ultrasonic pulse velocity (UPV) and the compressive strength test of concrete containing PET (Polyethylene terephthalate). This was achieved by measuring ultrasonic pulse velocity (UPV) on this type of concrete and comparing the result of compressive strength tests to clarify the accuracy of the ultrasonic test equation for this type of concrete. Waste bottles of water was used in this study by cutting them into laminar form of fibers with zigzag edges in different length (1,2,3) cm for each volume fraction of PET (1%,2% and 3%) by cement weight with fixed width (0.5) cm. Then, they were incorporated with the concrete. It was noticed from the laboratory tests results that the relationship UPV - strength are related together in the volume fraction of 1% for the length 3cm and the correlation factor (R) is equal to 0.94. This indicates a very good exponential relationship between UPV and compressive strength. Also, the results are compared and discussed with another proposed formula that found in literature.


Article
Producing Equation for Non-destructive Tests from Empirical Equation by Using Statistical Program
استنباط معادلة للفحوص الغيراتلافية من معادلات وضعية سابقة بأستخدام البرامج الاحصائية

Authors: ايمن جميل كاظم لسعد --- ليث محمد رضا حمود --- حيدر عباس عاشور
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2015 Volume: 13 Issue: 4 Pages: 96-102
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

The Non-destructive tests considered one of the most important solvent of losing cubing test to estimate compressive strength .The objective of research is main to find a relationship between many situations of combined method equations for Non-destructive tests between Ultrasonic Pulse Velocity tests, hammer rebound test. Also for producing a new equation where, the variation and the contrast between the use of the highest values and minimum values is lower than the previous equations. Using of advanced statistical programs such as (SPSS) program as well as program (Mini Tab) makes rustles more confidence. The conclusion equation has experimented with real data for one building, it was found that this equation gives medium rates and formulas used and therefore that the use of this equation gives excellent results and removed the negative consequences of the equations of the other.

ان الهدف الرئيسي من البحث هو ايجاد علاقة مشتركة بين العديد من المعادلات الوضعية الرصينة للفحوص الغيراتلافية للطريقة المشتركة بين فحص الامواج فوق الصوتية وفحص ارتداد المطرقة ووضعها بصيغة معادلة جديدة يكون فيها التشتت والتباين بين استخدام القيم العليا والقيم الدنيا قليلا جدا من خلال استخدام برامج احصائية متقدمة وهي برنامج (SPSS) وكذلك برنامج (Mini Tab). ان المعادلة المستنتجة تم اختبارها على بيانات حقيقية لاحد البنايات قيد الانشاء حيث تم التوصل الى ان هذه المعادلة تعطي منتصفات ومعدلات المعادلات المستخدمة وبالتالي ان استخدام هذه المعادلة تعطي نتائج دقيقة وازالت النتائج السلبية للمعادلات الاخرى.


Article
Statistical Equations to Estimate the In-situ Concrete Compressive Strength from Non-destructive Tests
معادلات احصائية لحساب مقاومة انضغاط الخرسانة الموقعية من خلال الفحوصات اللأتلافية

Author: Ahmed Faleh Al-Bayati احمد فالح البياتي
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2018 Volume: 24 Issue: 11 Pages: 53-67
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The aim of this study is to propose reliable equations to estimate the in-situ concrete compressive strength from the non-destructive test. Three equations were proposed: the first equation considers the number of rebound hummer only, the second equation consider the ultrasonic pulse velocity only, and the third equation combines the number of rebound hummer and the ultrasonic pulse velocity. The proposed equations were derived from non-linear regression analysis and they were calibrated with the test results of 372 concrete specimens compiled from the literature. The performance of the proposed equations was tested by comparing their strength estimations with those of related existing equations from literature. Comparisons revealed that the proposed ultrasonic pulse velocity and combined equations achieved better agreements with the test results than the related existing equations, whereas the proposed and the existing rebound hummer equations were inconsistent.

تهدف هذه الدراسة الى ايجاد معادلات موثوقة لحساب مقاومة انضغاط الخرسانة الحقلية من خلال الفحوصات اللااتلافية. ثلاث معادلات أقترحت في هذه الدراسة: المعادلة المقترحة الاولى تعتمد على رقم الارتاد في فحص المطرقة, المعادلة الثانية تعتمد على سرعة الامواج فوق الصوتية, المعادلة الثالثة تدمج بين رقم الارتداد في فحص المطرقة و سرعة الامواج فوق الصوتية في حساب مقاومة الانضغاط للخرسانة. تم تطوير هذه المعادلات باستخدام التحليل اللاخطي والنتائج المختبرية الخاصة ب 372 نموذج من البحوث السابقة.تمت مقارنة نتائج حساب مقاومة الانضغاط بواسطة المعادلات المقترحة مع المعادلات المقترحة مسبقا للتأكد من دقة المعادلات المقترحة. اظهرت المقارنات ان المعادلة المدمجة وتلك التي تعتمد على سرعة الامواج فوق الصوتية المقترحتين في هذا البحث اكثر دقة في حساب مقاومة الانضغاط للخرسانة من المعادلات المقترحة مسبقا المناظره لهما. فيما كانت حسابات مقاومة الانضغاط للخرسانة بواسطة المعادلة المقترحة في هذا البحث التي تعتمد على رقم الارتداد في فحص المطرقة والمعادلات المقترحة مسبقا المناظرة لها غير دقيقة.