research centers


Search results: Found 4

Listing 1 - 4 of 4
Sort by

Article
Removal of Oil From Wastewater UsingWalnut-Shell
ازالة الزيوت من المياه الملوثة بها باستخدام قشور ثمار الجوز

Author: Dr. Zainab Ziad Ismail زينب زياد اسماعيل
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2005 Volume: 1 Issue: 1 Pages: 117-124
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The ability of pulverized walnut-shell to remove oil from aqueous solutions has been studied. It involves two-phase process which consists of using walnut-shell as a filtering bed for the accumulation and adsorption of oil onto its surface. Up to 96% oil removal from synthetic wastewater samples was achieved while tests results showed that 75% of oil can be removed from the actual wastewater discharged from Al- Duara refinery in the south of Baghdad.

تم في هذا البحث دراسة قابلية مسحوق قشور ثمار الجوز في إزالة الزيوت من المياه الملوثة بها. تتضمن عملية الإزالة وجود طورين هما الطور السائل الملوث بالزيت والطور الصلب (مسحوق قشور الجوز) الذي يتم تراكم وامتصاص الزيت عليه. تم استخدام مجموعتين من النماذج المائية الملوثة بالزيت في التجارب العملية, المجموعة الأولى محضرة مختبريا وقد بلغت نسبة إزالة الزيت من هذه النماذج 96%. أما المجموعة الثانية فهي نماذج حقيقية تم جمعها من مياه الصرف الصناعية في مصافي الدورة جنوب بغداد وقد بلغت نسبة إزالة الزيت منها 75%


Article
Removal Of Oil From Wastewater By Organoclay Prepared From Iraqi Bentonite

Authors: Jassim M. Kshash --- Abbas H. Sulaymon
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2010 Volume: 16 Issue: 4 Pages: 5778-5798
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present study deals with the removal of oil from wastewater by organoclay. The organoclay was prepared by combination of Iraqi bentonite with quaternary amine (hexadecyltrimethyl ammonium chloride). The wastewater samples were obtained from the washing unit of fuel oil in the "South Baghdad Gas Power Plant". The operating conditions of batch process for removal of oil from wastewater by using the prepared organoclays were studied in details (quantity of organoclay, mixer speed and time of adsorption). Initial concentration of wastewater used in this study was within a maximum range of 230-1512 mg/L. XRD and FTIR diagram of the prepared organoclay showed a considerable differences from those for natural bentonite which indicates the exchange of quaternary amine with Ca++ ions at the surface of bentonite. The concentration of oil in the wastewater samples decreased below 10 mg/L after treatment with organoclay. Batch kinetics studies were conducted by using kinetic equations (Lagergren and Ho et al) and batch isotherm studies was conducted by using isotherm models (Freundlich, Langmuir and BET).

يتناول هذا البحث عملية إزالة الملوثات النفطية من المياه الصناعية باستخدام الطين العضوي. ان الطين العضوي المستخدم في هذا البحث تم تصنيعه عن طريق مزج خام البنتونايت العراقي (Iraqi bentonite) مع الامين الرباعي المسمى هكساديسايل تراي ميثايل امونيوم كلورايد (hexadecyltrimethyl ammonium chloride). إن مخلفات المياه(wastewater) المستخدمة في هذه الدراسة أخذت من وحده غسل زيت الوقود (fuel oil ) الموجودة في محطة كهرباء جنوب بغداد الغازية. لقد تم دراسة الظروف التشغيلية لإزالة زيت الوقود (fuel oil) من نموذجين من المياه الصناعية بالتفصيل (كمية الطين العضوي و سرعة الخلاط وزمن الامدصاص). ان التراكيز الأولية للمياه الصناعية المستخدمة في التجارب كانت ضمن حدود 230 الى 1512 مل/لتر. النتائج التي تم الحصول عليها من مخططات الأشعة السينية (XRD) وكذلك مخططات الأشعة تحت الحمراء (FTIR) للطين العضوي المحضر اظهرت اختلاف واضح عن مثيلاتها العائدة للبنتونايت وهذا يشير الى استبدال ايونات الكالسيوم Ca++ الموجودة على سطح البنتونايت بايونات الأمين الرباعي الموجبة. النتائج المستخلصة من هذه الدراسة بينت إن تركيز الملوثات النفطية في المياه الصناعية انخفض دون 10 ملغم/لتر (الحدود المسموح بها لتصريف المياه الملوثة بالنفط) بعد معاملتها بالطين العضوي. كذلك تم دراسة حركية عملية الامتزاز (Kinetics) باستخدام المعادلات الحركية (Lagergren and Ho. et al) ودراسة سعة عملية الامتزاز ((adsorption capacity باستخدام النماذج الرياضية(Freundlich, Langmuir, and BET) .


Article
Removal of Oil from Industrial Wastewater Using Organoclay Prepared From Iraqi Bentonite

Author: Jasem Mohammed Kashash
Journal: Journal of Petroleum Research & Studies مجلة البحوث والدراسات النفطية ISSN: 22205381 Year: 2012 Volume: 212 Issue: 6th Pages: 80-112
Publisher: Ministry of Oil وزارة النفط

Loading...
Loading...
Abstract

The present study deals with the removal of oil from wastewater by organoclay. The organoclay was prepared by combination of Iraqi bentonite with quaternary amine (hexadecyltrimethyl ammonium chloride). The wastewater used in this study taken from the washing unit of fuel oil in the "South Baghdad Gas Power Plant". The operating conditions of batch process for removal of oil from wastewater by using the prepared organoclays were studied in details (quantity of organoclay, mixer speed and time of adsorption). Initial concentration of wastewater used in this study was within the maximum range 230-1512 mg/L. XRD and FTIR diagram of the prepared organoclay showed considered differences from those for natural bentonite which indicates the exchange of quaternary amine with Ca++ ions at the surface of bentonite. The concentration of oil in the wastewater decreased less than 10 mg/L after treatment with organoclay. Batch kinetics studies were conducted by using kinetic equations (Lagergren and Ho et al) and batch isotherm studies was conducted by using isotherm models (Freundlich, Langmuir and BET).

يتناول هذا البحث عملية إزالة الملوثات النفطية من المياه الصناعية باستخدام الطين العضوي. ان الطين العضوي المستخدم في هذا البحث تم تصنيعه عن طريق مزج خام البنتونايت العراقي (Iraqi bentonite) مع الامين الرباعي المسمى هكساديسايل تراي ميثايل امونيوم كلورايد (hexadecyltrimethyl ammonium chloride). إن مخلفات المياه(wastewater) المستخدمة في هذه الدراسة أخذت من وحده غسل زيت الوقود (fuel oil ) الموجودة في محطة كهرباء جنوب بغداد الغازية. لقد تم دراسة الظروف التشغيلية لإزالة زيت الوقود (fuel oil) من نموذجين من المياه الصناعية بالتفصيل (كمية الطين العضوي و سرعة الخلاط وزمن الامدصاص). ان التراكيز الأولية للمياه الصناعية المستخدمة في التجارب كانت ضمن حدود 230 الى 1512 ملغم/لتر. النتائج التي تم الحصول عليها من مخططات الأشعة السينية (XRD) وكذلك مخططات الأشعة تحت الحمراء (FTIR) للطين العضوي المحضر اظهرت اختلاف واضح عن مثيلاتها العائدة للبنتونايت وهذا يشير الى استبدال ايونات الكالسيوم Ca++ الموجودة على سطح البنتونايت بايونات الأمين الرباعي الموجبة. النتائج المستخلصة من هذه الدراسة بينت إن تركيز الملوثات النفطية في المياه الصناعية انخفض دون 10 ملغم/لتر (الحدود المسموح بها لتصريف المياه الملوثة بالنفط) بعد معاملتها بالطين العضوي. كذلك تم دراسة حركية عملية الامتزاز (Kinetics) باستخدام المعادلات الحركية (Lagergren and Ho. et al) ودراسة سعة عملية الامتزاز ((adsorption capacity باستخدام النماذج الرياضية (Freundlich, Langmuir, and BET).


Article
Oily Wastewater Treatment Using Expanded Beds of Activated Carbon and Zeolite

Loading...
Loading...
Abstract

Two types of adsorbents were used to treat oily wastewater, activated carbon and zeolite. The removal efficiencies of these materials were compared to each other. The results showed that activated carbon performed some better properties in removal of oil. The experimental methods which were employed in this investigation included batch and column studies. The former was used to evaluate the rate and equilibrium of carbon and zeolie adsorption, while the latter was used to determine treatment efficiencies and performance characteristics. Expanded bed adsorber was constructed in the column studies. In this study, the adsorption behavior of vegetable oil (corn oil) onto activated carbon and zeolite was examined as a function of the concentration of the adsorbate, contact time, adsorbent dosage and amount of coagulant salt(calcium sulphate) added . The adsorption data was modeled with Freundlich and Langmuir adsorption isotherms. and it was found that the adsorption process on activated carbon and zeolite fit the Freundlich isotherm model. The amount of oil adsorbed increased with increasing the contact time, but longer mixing duration did not increase residual oil removal from wastewater due to the coverage of the adsorbent surface with oil molecules. It was found that as the dosage of adsorbent increased, the percentage of residual oil removal also increased. The effects of adsorbent type and amount of coagulant salt(calcium sulphate) added on the breakthrough curve were studied in details in the column studies. Expanded bed behavior was modeled using the Richardson-Zaki correlation between the superficial velocity of the feed stream and the void fraction of the bed at moderate Reynolds number.

تم في هذه الدراسة معالجة مياه التصريف الزيتية بواسطة الامتزاز على الكاربون المنشط والزيولايت واستخدمت طريقة الامتزاز ذو الدفعات وباستخدام الاعمدة المتمددة. حيث استخدمت الاولى لايجاد معدل وعلاقة الامتزاز للزيت على الكاربون المنشط والزيولايت بينما استخدمت الثانية لايجاد كفاءة عملية المعاملة وايجاد الاداء. المتغيرات التي تم دراستها هي تركيز المادة الممتزة والزمن وكمية المادة المازة. في هذه الدراسة ، تم فحص سلوك الامتزاز للزيوت النباتية (زيت الذرة) على الكربون المنشط والزيولايت كدالة للتركيز ، وكمية المادة الممتزة وكمية الملح (كبريتات الكالسيوم) المضاف.تم تمثيل النتائج باستخدام علاقات الامتزاز ثابتة درجة الحرارة فروندليتش ولنكمير. ووجد أن معادلة فرويندلش تنطبق على عملية الامتزاز على الكربون المنشط والزيولايت. ان كمية الزيت الممتز تزداد مع زيادة زمن التماس وكذلك وجد ان زيادة المادة المازة ستزيد من نسبة ازالة الزيت. تم ايضا دراسة تاثير نوع المادة المازة المستخدمة على منحني المقاومة.تم تمثيل تصرف الاعمدة المتمددة باستخدام معادلة ريتشاردسن – زاكي بين السرعة الفراغية والجزء البيني للعمود في حدود معتدلة من رقم رينولدز.

Listing 1 - 4 of 4
Sort by
Narrow your search

Resource type

article (4)


Language

Arabic and English (2)

English (2)


Year
From To Submit

2012 (1)

2011 (1)

2010 (1)

2005 (1)