research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Effect of Using Anaerobic Selectors on the Performance of Continuous Flow Activated Sludge Systems
تأثير استخدام الأحواض الانتقائية اللاهوائية على كفاءة أنظمة الحماة المنشطة المستمرة الجريان-عربي

Authors: Dr. Kossay K. Al-Ahmady د. قصي كمال الدين الأحمدي --- HananHaqeIsmaeel حنان حقي إسماعيل
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2013 Volume: 21 Issue: 6 Pages: 88-99
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

AbstractIn this research, four experimental plants have been constructed and operated in order to study the impact of using the anaerobic selectors on the behavior and efficiency of the extended aeration activated sludge system. The study program was divided into three stages. In the first stage, the experimental plants were run on the hydraulic retention time of the aerobic reactor equals to (32) hours, whereas, the hydraulic retention times in the biological aerobic reactors for the second and the third stages were (24 and 18) hours respectively. The results of the study revealed that; adding the anaerobic selectors improves the properties of the aerobic biological treatment in terms of removing soluble organic materials (CODs) and the efficiency of removing phosphor (PO4). The results also showed that,the organic and phosphorus removal efficiency increases with increasing the hydraulic retention time of the anaerobic selector. In contrast the values of the sludge volume index (SVI) decreases with this increasing. Higher removal efficiencies were recorded in the experimental stations that include anaerobic selector, which operates on a hydraulic retention time of (120 min) followed by the plant with the selector of (60 min) detention time and in the last place the plant that include selector, which operates on a hydraulic retention time of (30 min).Keywords:Anaerobic selector, Activated sludge, HDT,SVI, Phosphorus removal, Organic removal

الملخصتم في هذا البحث إنشاء وتشغيل محطة اختباريه تتكون من أربعة مفاعلات بيولوجية لغرض دراسة تأثير استخدامالأحواض الانتقائية اللاهوائية على سلوك وكفاءة أداء وحدات الحماة المنشطة المستمرة الجريان.قسم برنامج العمل إلى ثلاثة مراحل تم في المرحلة الأولى تشغيل الوحدات الاختبارية على وقت تعويق هيدروليكي للمفاعل الهوائي يساوي (32 ساعة)، في حين كان وقت التعويق الهيدروليكي في المفاعل البيولوجي الهوائي وللمرحلتين الثانية والثالثة مساويا لـ (24 و 18 ساعة) وعلى التوالي.أثبتت نتائج البحث إن إضافة الأحواض الانتقائية اللاهوائية يحسن من خصائص المعالجة البيولوجية الهوائية من حيث إزالة المواد العضوية الذائبة والفسفور والخصائص الترسيبية للحماة البيولوجية. كذلك أظهرت النتائج أن هناك علاقة بين زيادة وقت التعويق الهيدروليكي للحوض الانتقائي اللاهوائي وكفاءة إزالة كل من المواد العضوية والفسفور وتحسين خصائص الحمأة حيث تزداد كفاءة إزالة المواد العضوية والفسفور مع زيادة وقت التعويق الهيدروليكي للأحواض الانتقائية اللاهوائية، بالمقابل تقل قيمة معامل دليل الحماة الحجمي مع زيادة وقت التعويق الهيدروليكي للأحواض الانتقائية،حيث لوحظ أن أفضل كفاءة إزالة واقل معامل دليل حماة حجمي (SVI) تحقق في المحطة الاختبارية الحاوية على حوض انتقائي يعمل بوقت تعويق يساوي (120) دقيقة تليها المحطة الاختبارية ذات الحوض الانتقائي اللاهوائي الذي يعمل بوقت تعويق يساوي (60) دقيقة ثم المحطة ذات الحوض الانتقائي الذي يعمل بوقت تعويق يساوي (30) دقيقة.


Article
Effect of Continuous and Intermittent Aeration Modes on the Efficiency of the Continuous Flow Extended Aeration Activated Sludge Systems
مقارنة تأثیر أسلوبي التھویة المستمرة والتھویة المتقطعة على كفاءة أنظمة الحمأة المنشطة ذات التھویة المطولة والجریان المستمر

Authors: Kossay K. Al-Ahmady قصي كمال الدین الاحمدي --- Ammar A. Al-Sultan عمار عبدلله السلطان
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 13 Part (A) Engineering Pages: 498-512
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In this research an experimental plant was constructed and operated in order to study the efficiency of the intermittent aeration activated sludge system that operated at the ratio of (On/Off aeration times) (15min/15min), (30min/30min), (60min/60min), (90min/90min) and (120min/120min) and compare their performance with the continuous flow extended aeration activated sludge. The results of the study revealed that; extended aeration reactor is more efficient in removing organic matter than the intermittent aeration reactors. At the hydraulic detention times of (24, 18 and 32), 100%, 65% and 100% of effluent readings had organic concentration less than the acceptable effluent level in compare to 75%, 60% and 80% at the (90min/90min) reactor. In comparison of On/Off aeration times, (90min/90min) reactors provide the best organic removal. All readings from the extended aeration and (15min/15min), (60min/60min), and (90min/90min) reactors were within the acceptable level for effluent suspended solids while the effluent concentrations from the (120min/120min) reactors were higher. The results also indicated that, intermittent aeration reactors are better in removing phosphorous than the extended aeration. At the detention times of 24 and 18 hours, 8% and 6% of readings from the extended aeration reactors had (PO4 ≤ 5 mg/l) in compare to 90% and 52% of readings from the (60min/60min) reactor. At detention time of 32 hours, 32% of readings from the extended aeration reactor had (PO4 ≤ 2 mg/l) in compare to 72% for the (60min/60min) reactor. Higher phosphorus removals were recorded at (60min/60min) reactors.

تم في هذا البحث دراسة تأثير التهوية المتقطعة على كفاءة أنظمة الحمأة المنشطة ذات الجريان المستمر وذلك من خلال إنشاء وتشغيل محطة اختبارية تعمل بنظام الجريان المستمر والتهوية المتقطعة وبأوقات تشغيل وإيقاف تهوية (15min/15min)، (30min/30min)،(60min/60min) ،(90min/90min)،(120min/120min) ومقارنتها مع نظام الحمأة المنشطة ذو الجريان المستمر والتهوية المطولة حيث استخدمت مياه المطروحات الصناعية لمصنع أدوية نينوى مصدرا للفضلات السائلة. أثبتت نتائج البحث أن نظام التهوية المطولة ذو كفاءة أعلى في إزالة المواد العضوية من نظام التهوية المتقطعة، حيث كانت 100% و 65 % و 100% من القراءاتلتراكيز المياه الخارجة من مفاعلاتالتهوية المطولة العاملة بأوقات مكوث هيدروليكي (24، 18 و 32) ساعة تقع ضمن محددات الطرح المحلية مقابل 75% و 60% و 80% لمفاعلات التهوية المتقطعة (90min/90min) العاملة بنفس اوقات المكوث وعلى التوالي،وكان افضل تشغيل متقطع لإزالة المواد العضوية هو (90min/90min). وكانت جميع القراءات المسجلة لتراكيز المواد الصلبة العالقة الخارجة من مفاعلات التهوية المطولة والتهوية المتقطعة (15min/15min)،(60min/60min) و (90min/90min)ضمن حدود مواصفات الطرح المعتمدة، كماتفوقتمفاعلات التهوية المستمرة على مفاعلات التهوية المتقطعة من حيث انخفاض تراكيز المواد الصلبة العالقة في المياه الخارجة،كذلككانت الدورات الطويلة لتشغيل وإيقاف التهوية (120min/120min) ذات كفاءة اقل من حيث تراكيزهذه المواد. كما واثبتت النتائج ان مفاعلاتالتهوية المتقطعة افضلمن مفاعلات التهوية المستمرة في إزالة الفسفور حيث كانت 8% و 6% من تراكيز الفوسفات في المياه الخارجة من مفاعلات التهوية المطولة العاملة بأوقات مكوث هيدروليكي (24 و 18) ساعة اقل او يساوي 5 ملغم/لتر، مقابل 90% و 52% لمفاعلات التهوية المتقطعة (60min/60min) العاملة بنفس اوقات المكوث وعلى التوالي،وكانت 32% من تراكيز المياه الخارجة من مفاعل نظام التهوية المطولة العاملة بوقت مكوث هيدروليكي 32 ساعة ذات تركيز فوسفات اقل او يساوي 2 ملغم/لتر مقابل 72% لمفاعل التهوية المتقطعة (60min/60min). وان أفضل تشغيل متقطع لإزالة الفسفور هو (60min/60min).

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic (2)


Year
From To Submit

2014 (1)

2013 (1)