research centers


Search results: Found 34

Listing 1 - 10 of 34 << page
of 4
>>
Sort by

Article
A Study of Water Flux through Forward Osmosis Membrane Using BrineFresh Water System

Authors: Adel A. Al-Hemiri عادل احمد عوض --- Marwah M. Kamil مروة مازن
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2013 Volume: 14 Issue: 4 Pages: 11-18
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present work aims to improve the flux of forward osmosis with the use of Thin Film Composite membrane by reducing the effect of polarization on draw solution (brine solution) side.This study was conducted in two parts. The first is under the effect of polarization in which the flux and the water permeability coefficient (A) were calculated. In the second part of the study the experiments were repeated using a circulating pump at various speeds to make turbulence and reduce the effect of polarization on the brine solution side.A model capable of predicting water permeability coefficient has been derived, and this is given by the following equations:z = Z_0 + (C.R.T)/(9.8 ( d^2/D^(2 ) +1) ) [Exp. [- 9.8 ( d^2/D^(2 ) +1 ) (A.M )/ρ . t] -1]


Article
Efficiency and Reliability of Reverse Osmosis Desalination Systems

Author: Ayad A. F. Al-Dulaimi
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2007 Volume: 8 Issue: 4 Pages: 59-62
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This study is concerned with the evaluation of the effect of Euphrates River water quality in Al-Samawa region duringthe period 1984-2003 on efficiency and reliability of reverse osmosis desalination systems by calculating the calciumsulfate scaling index depending on the following indicators: - TDS, Ca+2, Mg+2, Na+1, Cl-1, So4-2, HCO3-1. It wasfound from data analysis that this index for these units is greater than permissible limit. Also, the fitted relationshipbetween this index and TDS is logarithmic, i.e. this index varies more rapidly than TDS, and consequently it is morerepresentative to the water quality than TDS.


Article
STUDY OF THE EFFICIENCY OF REVERSE OSMOSIS SYSTEM FOR WATER DESALINATION
دراسة كفاءة نظام تحليه المياه بالتناضح العكسي

Authors: Anas B. Salman انس بديوي سلمان --- Dr. Ra’id Tarik Hade رائد طارق هادي
Journal: Muthanna Journal of Engineering and Technology(MJET) مجلة المثنى للهندسة والتكنولوجيا ISSN: 25720317 25720325 Year: 2013 Volume: 2 Issue: 2 Pages: 17-29
Publisher: Al-Muthanna University جامعة المثنى

Loading...
Loading...
Abstract

This paper studied th effect of operating parameters on the efficiency of a small scale reverse osmosis with cellulose acetate (CA) membrane type has been studied. different samples were selected from several wells from different spots from Baghdad city. It was found that the highest system’s efficiency can be attained at 36 oC temperature, 250 pressure, pH=3 and 2000 ppm salinity. Also it has been found that the reflux ratio is proportional to the pressure and temperature of feed water, and this ratio is inversely proportional with the pH and salinity of feed water. Four samples with different salinity values were selected from wells in south of iraq.

في هذا البحث, تمت دراسة تاثير الظروف التشغيلية على كفاءة منظومة مصغرة لتحلية المياه بواسطة التناضح العكسي ي الغشاء التنافذي من نوع ( سيليلوز اسبست). حيث تم استخدام عينات مختلفة من ابار موزعة على مناطق متفرقة من جنوب بغداد. تم التوصل الى انه اعلى كفاءة للمنظومة المستخدمة كانت تحت حرارة 36 م وضغط 250 بار وحامضية بمقدار pH = 3 وملوحة بمقدار 200 جزء بالمليون, كما تم التوصل الى انه نسبة الارجاع تتناسب تناسب طردي مع كل من الضغط والحرارة للماء الداخل الى المنظومة, كما تم التوصل الى انه نسبة الارجاع تتناسب تناسب عكسي مع حموضية وملوحة الماء الداخل الى المنظومة.


Article
Thermal Osmosis of Mixtures of Water and Organic Compounds through Different Membranes

Authors: Ahmed Faiq Al-Alawy --- Ramy Mohamed Al – Alawy
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2016 Volume: 17 Issue: 2 Pages: 53-68
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present work aimed to study the efficiency of thermal osmosis process for recovery of water from organic wastewater solution and study the factors affecting the performance of the osmosis cell. The driving force in the thermo osmosis cell is provided by a difference in temperature across the membrane sides between the draw and feed solution. In this research used a cellulose triacetate (CTA), as flat sheet membranes for treatment of organic wastewater under orientation membrane of active layer facing feed solution (FS) and draw solution (DS) is placed against the support layer. The organic materials were phenol, toluene, xylene and BTX (benzene, toluene, and xylene) used as feed solution. The osmotic agent in draw solution was sodium chloride salt. The membranes have high rejection percentage for NaCl and organic materials. In this research, the operating conditions that have been studied are: temperature of draw and feed solution (18 – 45 °C) and the operating time of process was (0 – 3) hours. It was found that water flux in thermal osmosis process increases with increasing temperature of draw and feed solution ( by average ratio 1:2), and decreases with increasing operating time.


Article
Forward and Reverse Osmosis Process for Recovery and Re-use of Water from Polluted Water by Phenol
عملية التناضح الامامي والعكسي لاسترجاع واعادة استخدام الماء من المياه الملوثة بالفينول

Author: Ahmed Faiq Al-Alawy
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2011 Volume: 17 Issue: 4 Pages: 912-928
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The research aims to apply the novel forward osmosis (FO) process to recover pure water from contaminated water. Phenol was used as organic substance in the feed solution, while sodium chloride salt was used as draw solution. Membranes used in the FO process is the cellulose triacetate (CTA) and polyamide (thin film composite (TFC)) membrane. Reverse osmosis process was used to treatment the draw solution, the exterior from the forward osmosis process. In the FO process the active layer of the membrane faces the feed solution and the porous support layer faces the draw solution and this will show the effect of dilutive internal concentration polarization and concentrative external concentration polarization.In the FO process was a run-time for five hours, and the concentration of phenol 100 and 1000 mg/l, and for the NaCl the concentration was 10000 and 30000 mg/l. It was found that recovery percent increases with increasing time, while water flux through membrane decreases with increasing time. Also, it was found that recovery and water flux increases with increasing draw solution concentration, on the contrary, water flux and the percentage of recovery decreases with increasing the concentration of phenol (feed solution). Increase in draw solute (NaCl) concentration has more effect on the water flux in FO process compared with increase in the concentration of phenol. Outlet phenol concentration increases with time, while the outlet salt concentration decreases with increasing the time. The results showed that the cellulose triacetate membrane gave the highest recovery ratio from the thin film composite membrane. The highest recovery was reached in five hours is 51.33%, while using CTA membrane recovery rate increase, by 23% compared with TFC membrane. The value of the resistance to solute diffusion within the membrane porous support layer is 36.83 h/m. Reverse osmosis is perfect method for removal of dissolved salts from water, thus its suitable process for reducing the content of NaCl in draw solution; therefore the sodium chloride rejection percentage was 91.6 – 96 % for polyamide membrane (TFC). Within two hours of work of the reverse osmosis system the recovery percentage of pure water is 58%.

يهدف البحث الى تطبيق عملية التناضح الامامي(FO) الجديدة لاسترجاع الماء النقي من المياه الملوثة. تم استخدام الفينول كمادة عضوية في محلول التغذية, بينما تم استخدام ملح كلوريد الصوديوم كمحلول سحب. الاغشية المستخدمة في عملية التناضح الامامي هي غشاء الأسيتات الثلاثي السليلوزي (CTA) وغشاء البولي امايد (البوليمر الرقيق المركب (TFC)). تم استخدام عملية التناضح العكسي لمعالجة محلول السحب الخارج من عملية التناضح العكسي. في عملية التناضح الامامي الطبقة الفعالة للغشاء تقابل محلول التغذية وطبقة الدعم المسامية تقابل محلول السحب وهذا سوف يظهر تاثير استقطاب التركيز الداخلي المخفف واستقطاب التركيز الخارجي المركز. في عملية التناضح الامامي كان وقت التشغيل لمدة خمس ساعات ، وتركيز الفينول المستخدم 100 و 1000 مغ لتر ، وبالنسبة لتركيز NaCl كان 10000 و 30000 ملغم لتر. لقد وجد بأن نسبة الاسترجاع تزداد بزيادة الزمن ، في حين تدفق الماء خلال الغشاء يتناقص مع زيادة الوقت. وكذلك, لقد وجد بان الاسترجاع وتدفق الماء يزداد بزيادة تركيز محلول السحب, وبالعكس, تدفق الماء ونسبة الاسترجاع تقل بزيادة تركيز الفينول (محلول التغذية). الزيادة في تركيز مذاب السحب (NaCl) له تأثير اكثر على معدل تدفق الماء في عملية التناضح الامامي مقارنةً بالزيادة في تركيز الفينول. تركيز الفينول الخارج يزداد مع الزمن, بينما تركيز الملح الخارج يقل بزيادة الزمن. وأظهرت النتائج أن غشاء الأسيتات الثلاثي السليلوزي أعطى أعلى نسبة استرجاع من الغشاء الرقيق المركب. اعلى نسبة مئوية للاسترجاع تم التوصل اليها في خمس ساعات هي 51,33% ,بينما استخدام غشاء CTA الاسترجاع زاد بنسبة 23% مقارنةً باستخدام غشاء TFC. قيمة المقاومة لانتشار المذاب داخل الطبقة الداعمة المسامية للغشاء هي 36،83 ساعة م. التناضح العكسي هي طريقة مثالية لأزالة الاملاح الذائبة من الماء, لهذا تعتبر عملية مناسبة لتقليل محتوى ملح كلوريد الصوديوم في محلول السحب, ولهذا النسبة المئوية لرفض كلوريد الصوديوم كانت 91,6 – 96 % لغشاء البوليمر (TFC). خلال ساعتين من عمل نظام التناضح العكسي نسبة استرجاع الماء النقي هي 58 ٪.


Article
Concentration of Orange Juice Using Forward Osmosis Membrane Process

Author: Khalid W. Hameed خالد وليد حميد
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2013 Volume: 14 Issue: 4 Pages: 71-79
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Forward osmosis (FO) process was applied to concentrate the orange juice. FO relies on the driving force generating from osmotic pressure difference that result from concentration difference between the draw solution (DS) and orange juice as feed solution (FS). This driving force makes the water to transport from orange juice across a semi-permeable membrane to the DS without any energy applied. Thermal and pressure-driven dewatering methods are widely used, but they are prohibitively energy intensive and hence, expensive. Effects of various operating conditions on flux have been investigated. Four types of salts were used in the DS, (NaCl, CaCl2, KCl, and MgSO4) as osmotic agent and the experiments were performed at the concentration of the salts in the DS ranged (3.5 – 20% by wt), the temperature of DS ranged (20 – 50oC), and the flow rate of the FS and DS ranged (1 – 4 lit/min). It was observed that the optimum operating conditions are: concentration of salt = 20% by wt for CaCl2, temperature of DS = 50oC, and the flow rate of FS = 4 lit/min where at these conditions the maximum flux was obtained equal to 13.2 lit/m2.h or the total volume of the water transferred from the juice (during 3 hours and membrane area of 0.0135 m2) was 0.535 lit. NaCl performed much higher efficiency as osmotic agent than the others salts up to the concentration of 15.2%, but after 15.2% the CaCl2 was the best.


Article
A Study of Forward Osmosis Using Various Drawing Agents

Authors: Adil A. Al-Hemiri عادل احمد الحميري --- ِAdil O. Sharif --- Mustafa Hussein
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2009 Volume: 10 Issue: 3 Pages: 51-56
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This research was aimed to study the osmotic efficiency of the draw solutions and the factors affecting the performance of forward osmosis process. The draw solutions used were magnesium sulfate hydrate (MgSO4.7H2O), potassium chloride (KCl), calcium chloride (CaCl2), and ammonium bicarbonate (NH4HCO3). It was found that water flux increases with increasing draw solution concentration, and feed solution flow rate and decreases with increasing draw solution flow rate and feed solution concentration. And also found that the efficiency of the draw solutions is in the following order:CaCl2> KCl> NH4HCO3> MgSO4.7H2O


Article
Forward Osmosis Process for the Treatment of Wastewater from Textile Industries
عملية التناضح الامامية لمعالجة مخلفات المياه من الصناعات النسيجية

Authors: Hasan F. Makki حسن فرهود مكي --- Majid I. Abdul Wahab ماجد ابراهيم عبدالوهاب --- Rana Raheem Said رنا رحيم سيد
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2013 Volume: 19 Issue: 12 Pages: 1557-1565
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This paper was aimed to study the efficiency of forward osmosis (FO) process as a new application for the treatment of wastewater from textile effluent and the factors affecting the performance of forward osmosis process.The draw solutions used were magnesium chloride (MgCl2), and aluminum sulphate (Al2 ( SO4)3 .18 H2O), and the feed solutions used were reactive red, and disperse blue dyes. Experimental work were includes operating the forward osmosis process using thin film composite (TFC) membrane as flat sheet for different draw solutions and feed solutions. The operating parameters studied were : draw solutions concentration (10 – 90 g/l), feed solutions concentration (5 – 30 mg/l), draw solutions flow rate (10 – 50 l/hr), feed solutions flow rate (20-60 l/hr), constant pressure and temperature were maintained at 0.5 bar and 30ºC respectively. And includes operating the forward osmosis process using cellulose triacetate (CTA) membrane as flat sheet for different draw solutions and feed solutions. The operating parameters studied were : draw solutions concentration (10 – 90 g/l), and feed solutions concentration (5 – 30 mg/l), constant temperature at 30ºC. It was found that water flux increases with increasing draw solution concentration, and feed solution flow rate and decreases with increasing draw solution flow rate and feed solution concentration for TFC and CTA. It was found MgCl2 given water flux larger than Alum. And also found that reactive red given water flux larger than disperse blue.The experiments also show that CTA membrane gives higher water flux than TFC membrane for forward osmosis operation. The increase in water flux for CTA is about 12.85% than TFC.

يهدف هذا البحث الى دراسة كفاءة عملية التناضح الامامي كتطبيق جديد لمعالجة الفضلات الخارجة من الصناعات النسيجية والعوامل التي تؤثر على اداء عملية التناضح الامامي . محاليل السحب المستخدمة هي : كلوريد المغنيسيوم و كبريتات الالمنيوم المائية و محاليل اللقيم المستعملة هي : الاحمر المتفاعل و الازرق المنتشر . العمل التجريبي يتضمن تشغيل عملية التناضح الامامي باستخدام اغشية ( TFC ) على شكل صفيحة مستوية لمحاليل سحب مختلفة و محاليل لقيم مختلفة. العوامل التشغيلية التي تم دراستها : تركيز محاليل السحب (10-90غرام / لتر ), تركيز محاليل اللقيم (5-30ملغم / لتر) , معدل الجريان الحجمي لمحاليل السحب ( 10-50لتر / ساعة ) , معدل الجريان الحجمي لمحاليل اللقيم ( 20-60لتر / ساعة). الضغط و درجة الحرارة ثابتين عند0.5 بار و30 o م على التوالي . وكذلك يتضمن تشغيل الوحدة التناضحية بأستخدام اغشية من نوع CTA على شكل صفيحة مستوية . العوامل التشغيلية التي تم دراستها : تركيز محاليل السحب ( 10-90 غرام / لتر ) , و تركيز محاليل اللقيم ( 5-30ملغم / لتر )عند درجة حرارة ثابتة30o م. لقد وجد بأن معدل تدفق الماء يزداد بزيادة تركيز محلول السحب و معدل الجريان الحجمي لمحلول اللقيم ويقل بزيادة معدل الجريان الحجمي لمحلول السحب و تركيز محلول اللقيم لكلا الغشائين TFC)) وCTA)) .لقد وجد بان كلوريد المغنيسيوم يعطي معدل تدفق ماء اعلى من كبريتات الالمنيوم المائية . وايضا وجد بان الاحمر المتفاعل يعطي معدل تدفق ماء اعلى من الازرق المنتشر. اظهرت التجارب ايضا ان اغشية CTA تعطي معدل تدفق ماء اعلى من اغشية TFC في عمليات التناضح الامامي. ان الزيادة في معدل تدفق ماء لاغشية CTA تقريبا 12,85% من اغشية TFC.


Article
Water Treatment of Cooling Towers Blowdown by Reverse Osmosis

Authors: Ammar A. Beddai --- Adil Al-Hemiri
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2005 Volume: 11 Issue: 2 Pages: 421-428
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

An experimental investigation was conducted to study the effect of operating parameters on the permeable conductivity and product rate were studied for reverse osmosis process. The parameters studied were: - conductivity of feed water in the range of (1000-1500 us/cm), pH in the range of (4-10) and operating pressure in the range of (3-6 bar).The best operating conditions, which lead to good quantity and quality for water product, are: (1000 us/cm) conductivity of feed water, (7) pH and (6 bar) operating pressure. At these conditions the permeable conductivity is (52.905 us/cm) and the product rate is (328.143 1/hr).

تمت دراسة عوامل التشغيل التي تؤثر على النفاذية ونوعية الماء الناتج في عملية التنافذ العكسي وهذه العوامل كانت: موصلية الماء الداخل والاس الهيدروجيني والضغط التشغيليالنتائج دلت على ان الظروف التشغيلية التي تحقق كمية ونوعية عالية من الماء الناتج من عملية التنافذ العكسي هي: موصلية الماء الداخل (0us/cm100 (7) ph (والضغط التشغيلي (6 bar). عند هذة الظروف تكون موصلية الماء الناتج (52.905 us/cm) وانتاجية الغشاء (328.143 1/h).


Article
Forward-Reverse Osmosis Processes for Oily Wastewater Treatment
عمليات التنافذ الامامي-العكسي لمعالجة المياه الملوثة بالزيوت

Authors: Hasan Farhood Makki حسن فرهود مكي --- Noor Hammood Zghair نور حمود زغير
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2014 Volume: 20 Issue: 7 Pages: 191-212
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this study, the feasibility of Forward–Reverse osmosis processes was investigated for treating the oily wastewater. The first stage was applied forward osmosis process to recover pure water from oily wastewater. Sodium chloride (NaCl) and magnesium chloride (MgCl2) salts were used as draw solutions and the membrane that was used in forward osmosis (FO) process was cellulose triacetate (CTA) membrane. The operating parameters studied were: draw solution concentrations (0.25 – 0.75 M), oil concentration in feed solution (FS) (100-1000 ppm), the temperature of FS and draw solution (DS) (30 - 45 °C), pH of FS (4-10) and the flow rate of both DS and FS (20 - 60 l/h). It was found that the water flux and oil concentration in FS increase by increasing the concentration of draw solutions, the flow rate of FS and the temperature for a limit (40oC), then, the water flux and oil concentration decrease with increasing the temperature because of happening the internal concentration polarization phenomenon. By increasing the oil concentration in FS and the flow rate of the DS, the water flux and oil concentration in FS decreased, while it had a fluctuated behavior with increasing pH of oily wastewater. It was found also that MgCl2 gives water flux higher than NaCl. So the values of resistance to solute diffusion within the membrane porous support layer were 55.93 h/m and 26.21 h/m for NaCl and MgCl2 respectively. The second stage was applied reverse osmosis process using polyamide (thin film composite (TFC)) membrane for separating the fresh water from a diluted (NaCl) solution using different parameters such as draw solution concentration (0.08–0.16 M), feed flow rate (20–40 l/h).

في هذه الدراسة, تم بحث مدى ملائمة عمليات التنافذ (الامامي– العكسي) لمعالجة المياه الملوثة بالزيوت. في المرحلة الاولى طبقت عملية التنافذ الامامي لاسترجاع الماء النقي من المياه الملوثة بالزيوت. استخدمت كل من املاح كلوريد الصوديوم (NaCl ) و كلوريد المغنيسيوم (MgCl2) كمحاليل سحب, واستخدم غشاء السليلوز تراي اسيتيت خلال عملية التنافذ الامامي. الظروف التشغيلية التي تم دراستها هي : تركيز محاليل السحب (0,25 – 0,75مول / لتر), تركيز الزيت في محلول القيم (100 – 1000 جزء بالمليون), درجة حامضية اللقيم (4 – 10), درجة حرارة محلول اللقيم ومحلول السحب (30 - 45 مo) و معدل الجريان الحجمي لكل من محلول اللقيم ومحلول السحب (20 - 60 لتر/ساعة) , وجد ضمن مدى الظروف التشغيلية التي تم دراستها, ان معدل تدفق الماء وتركيز الزيت في محلول اللقيم يزداد بزيادة تركيز محلول السحب , معدل الجريان الحجمي لمحلول اللقيم و درجة الحرارة لمحاليل اللقيم والسحب لغاية (40 مo), بعد ذلك, يقل معدل تدفق الماء وتركيز الزيت في محلول اللقيم مع زيادة درجة الحرارة بسبب حدوث ظاهرة استقطاب التركيز الداخلي. بزيادة تركيز الزيت في محلول اللقيم و معدل الجريان الحجمي لمحلول السحب, يقل معدل تدفق الماء وتركيز الزيت في محلول اللقيم. بينما وجد ان له سلوك متذبذب بزيادة درجة حامضية اللقيم. كذلك وجد بأن املاح كلوريد المغنيسيوم تعطي معدل تدفق ماء اعلى من املاح كلوريد الصوديوم. كانت قيم المقاومة لانتشار المذاب داخل الطبقة الداعمة المسامية للغشاء ( 55,9 ساعة/ م) و ( 26,2 ساعة/ م) لكل من كلوريد الصوديوم و كلوريد المغنيسيوم على التوالي. المرحلة الثانية تم تطبيق عملية التنافذ العكسي لفصل الماء النقي من محلول كلوريد الصوديوم المخفف باستخدام متغيرات مختلفة كتركيز محلول السحب (0,08 – 0,16مول / لتر) ومعدل الجريان الحجمي لمحلول السحب (20 -40 لتر/ساعة).

Listing 1 - 10 of 34 << page
of 4
>>
Sort by
Narrow your search

Resource type

article (34)


Language

English (28)

Arabic (3)

Arabic and English (2)


Year
From To Submit

2019 (2)

2017 (4)

2016 (5)

2015 (3)

2014 (4)

More...