research centers


Search results: Found 22

Listing 1 - 10 of 22 << page
of 3
>>
Sort by

Article
OZONE THERAPY

Journal: Basrah Journal of Surgery مجلة البصرة الجراحية ISSN: 16833589 / ONLINE 2409501X Year: 2016 Volume: 22 Issue: 1 Pages: 3-7
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

Ozone therapy is a term that describes a number of different practices in which oxygen, ozone, or hydrogen peroxide are administered via gas or water to kill disease microorganisms, improve cellular function, and promote the healing of damaged tissues. The rationale behind bio-oxidative therapies, as they are sometimes known, is the concept that as long as the body's needs for antioxidants are met, the use of certain oxidative substances will stimulate the movement of oxygen atoms from the bloodstream to the cells. With higher levels of oxygen in the tissues, bacteria and viruses are killed along with defective tissue cells. The healthy cells survive and multiply more rapidly. The result is a stronger immune system.Ozone itself is a form of oxygen, O3, produced when ultraviolet light or an electric spark passes through air or oxygen. It is a toxic gas that creates free radicals, the opposite of what antioxidant vitamins do. Oxidation, however, is good when it occurs in harmful foreign organisms that have invaded the body. Ozone inactivates many disease bacteria and viruses.

Keywords

OZONE --- THERAPY


Article
Evaluation the Efficacy of Ozone and Temperature to Control Mover Stages for Hairy Grain Beetle (khapra) in Laboratory Trogoderma granariumEverts Coleoptera : Dermestidae.))
تقييم كفاءة استعمال غاز الاوزون و درجات الحرارة في مكافحة الادوار المتحركة لخنفساء الحبوب الشعرية(الخابرا) مختبريا Trogoderma granariumEverts Coleoptera : Dermestidae.))

Authors: Saadi H.Sabr سعدي حسين صبر --- Falah A. Sabet فلاح عبود سابط
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2015 Volume: 56 Issue: 3A Pages: 1904-1910
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

اختبر تاثير اتحاد غاز الاوزون مع درجات الحرارة 35 ،40 و45 سيلزية (Z+H) ومعاملة الحرارة المنفردة ((H فضلا عن معاملة المقارنة في الدور اليرقي والكاملة لحشرة T. granarium Everts ، فوجد ان المعاملتين كانتا افضل المعاملات في احداث نسب قتل عالية وصلت الى 100%(LT100) وتبين ان رفع درجات الحرارة يؤدي في تقليص فترات تعرضها للقتل الكلي وان المعاملة (Z+H) اشد تاثيرا من المعاملة ((H في دوري الحشرة كما ان درجة الحرارة35 و 40 سيلزية منفردة قد فشلت في التاثير في ادوار اليرقات والبالغات من الذكور والاناث ، وان درجة 45 سيلزية سواء كانت منفردة او متحدة مع غاز الاوزون هي الافضل في التاثير وعند مختلف فترات تعرضها ،كما اظهر ان دور البالغات كان اكثر حساسية للمعاملات اذ كانت المدة اللازمة لبلوغ نسبة القتل 100 % هي 0.40 و1.05 ساعة على التوالي فيما ظهر ان الاطوار المتقدمة في اليرقة هي الاكثر مقاومة من الاطوار المتوسطة والاولية فكانت المدة اللازمة لبلوغ نسبة القتل 100 % هي 0.50 و 1.05 ساعة على التوالي وان ذكور الحشرة كانت الاكثر حساسية من اناثها لتاثير المعاملات اذ بلغت نسبة القتل 100 % عند المددo.18 و0.30 ساعة على التوالي لتاثير المعاملات.

The effect of the following treatments were tested on the adult and larval stages of hairy grain beetle Trogoderma granarium (Everts).The treatments were the combination of ozone gaz with high temperatures ( 35، 40 and 45C) and tempreture alone in addition to control treatment. Results showed that (Z+H) and (H) treatments were more lethally effective (100%mortality) than other treatment on larvae and adult stages of insect. The results also showed that first treatment( Z+H) was more effective than the second treatment (H) on two stages ,the temperature alone treatment with 35,40C was not effective on larvae and adults ( male+femal) :while the temperature 45C alone and combined with Ozone gaz was more effective on two stages of insect .It was also found that adult stage was more sensetive to all treatments than larval stage,whereas the late instars larvae was more resistance than middle and early larva instars .the study indicated that insect males were more sensetive than females to the effect of all treatments.


Article
Evaluation the Efficacy of Ozone and High Temperature to Control Egges and Pupae Stages Laboratory for Hairy Grain Beetle (khapra) Trogoderma granarium Everts Coleoptera : Dermestidae
تقييم كفاءة استعمال غاز الاوزون و درجات الحرارة العالية على طوري البيض والعذارى لخنفساء الحبوب الشعرية(الخابرا) مختبريا.Trogoderma granarium Everts Coleoptera : Dermestidae

Authors: Falah A. Sabet فلاح عبود سابط --- Saadi H.Sabr سعدي حسين صبر
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2015 Volume: 56 Issue: 3B Pages: 2164-2169
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The effect of the treatments were the combination of ozone gaz with high temperatures ( 35، 40 and 45C) and tempreture alone in addition to control treatment treatments were tested on Egges and Pupae stages of hairy grain beetle Trogoderma granarium (Everts). Results showed that( Z+H) and (H) treatments were more lethally effective (100%mortality) than to control treatment on Egges and Pupae stages of insect . The results also showed that first treatment(Z+H) was more effective than the second treatment (H) on two stages , the total killings 100% (LT100) in eggs reached at periods 15.00, 13.00 hours and 18 minutes, respectively with treatment of the ozone gaz with high temperatures ( 35، 40 and 45C),when tempreture alone showed exposure to 0.0, 0.0 and 30 minutes. Result showed also the pupae stage was more resistant than egg stage the time required to achieve 100% kill ratio is 15.00, 13.30 and 1.00 hours, respectively, and in the treatment of tempreture alone showed exposure to 0.0, 0.0 and 1.15 hours, respectively. ,the temperature alone treatment with 35,40C was not effective on Egg and Pupae while the temperature 45C alone and combined with Ozone gaz was more effective on two stages of insect .It was also found that Egg stage was more sensetive to all treatments than Pupae stage at 45 Celsius.

اختبر تاثير معاملة اتحاد غاز الاوزون مع درجات الحرارة 35 ،40 و45 سيلزيه (Z+H) ومعاملة الحرارة المنفردة ((H فضلا عن معاملة المقارنة لطوري البيض و العذارى لحشرة T. granarium وجد ان المعاملتين كانتا الافضل في احداث نسب قتل عالية وصلت الى 100%(LT100) وتبين ان رفع درجات الحرارة أدى الى تقليص مدد تعرضها للقتل الكلي وان المعاملة الاولى اشد تاثيرا من المعاملة الثانية في طوري الحشرة وان درجتي الحرارة35 و 40 سيلزيه منفردة فشلت في التاثير في اطوار البيض والعذارى ، وان درجة 45 سيلزيه منفردة او متحدة مع غاز الاوزون الافضل في التاثير في طوري الحشرة وعند مختلف مدد تعرضها ، ففي الوقت الذي وصلت فيه نسبة القتل الكلي 100% (LT100) بين اعداد البيض في معاملة الاتحاد عند الدرجات الحرارية الثلاث عند المدد 15.00 ، 13.00ساعة و18 دقيقة على التوالي بلغت هذه النسب في معاملة الحرارة المنفردة عند مدد التعرض 0.0 ،0.0 و30 دقيقة وظهر ان طور العذراء من اكثر الاطوارمقاومة للمعاملات فكانت المدة اللازمة لبلوغ نسبة القتل 100 % هي 15.00, 13.30و 1.00ساعة على التوالي و في معاملة الحرارة المنفردة عند مدد التعرض 0.0 ،0.0 و1.15 ساعة على التوالي حيث لم يظهر اي تاثير لدرجات الحرارة ) 40,35 ).


Article
Mass transfer of ozone in purified water
انتقال كتلة الاوزون في الماء النقي

Authors: Omar J. Mahmood --- Riyadh S.Al-mukhtar --- Asawer A. Alwasit
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2009 Volume: 27 Issue: 4 Pages: 776-786
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This work presents the study of ozone mass transfer in water in bubble column with0.5cm inside diameter and 2 m height. The volumetric mass transfer, rate constant ofozone decomposition and mass transfer efficiency were studied with different gas flowrates (50,100, 150, 200, 250) L/min.The volumetric mass transfer as well as rate of decomposition of ozone was found toincrease with increasing gas flow rate. They were ranged between 0.21-0.41min-1 and0.018-0.036min-1 respectively.Mass transfer efficiency was increased from 77 to 98% with increasing gas flow rate.A mathematical model was numerically solved to describe the liquid ozoneconcentration with time. The model and experimental results agreed well.

هذا البحث يقدم دراسة عن انتقال كتلة الأوزون في الماء داخل عمود التفقيع بقطر 5 سم وارتفاع 2م. تم دراسة انتقال الكتلة ألحجمي, ثابت سرعة تحلل الأوزون و كفاءة انتقال الكتلة بسرع جريان مختلفة من الغاز 250 )لتر/دقيقة. , 200 , 150 ,100 ,50) - وجد إن انتقال الكتلة ألحجمي و ثابت سرعة التحلل يزدادان بازدياد سرع الجريان وتتراوح قيمهما بين 0.21 0.036 دقيقة- 1 على التوالي. - 0.41 دقيقة- 1 و 0.018 كفاءة انتقال الكتلة ازدادت من 77 % إلى 98 % بازدياد سرعة الجريان. تم حل موديل رياضي بصورة عددية لوصف تركيز الأوزون في السائل مع الزمن.كان هناك تطابق جيد بين قيم النتائج العملية وبين قيم نتائج الموديل.


Article
Measurement Of Ground Level Ozone In Selective Locations In Baghdad City

Authors: Sinan J. Mohammed --- Adnan H. Afaj --- Yasmen A. Mustafa
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2011 Volume: 17 Issue: 5 Pages: 1174-1190
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The ground level ozone concentration at different locations in Baghdad city was identified. Five different sites have been chosen to identify the ground level ozone concentration. Al- Dora and Al-Za'afarania were chosen as areas contained point source ( power plant station ) in addition to high traffic load , while Al –Uma park, Aden square and Al-Mawal square were chosen as area contained heavy traffic only (line source). The measurement focuses on spring and fall because these periods display favorable meteorology to ozone formation. During the research period the maximum values (peaks) for ground level ozone concentration were observed at fall: at Al-Za'afarania area 101ppb as an average, at Al-Dora 87 ppb as an average and at line source areas 48 ppb as an average. Among the line sources area Al-Mawal square represent the highest peak value at fall 68 ppb. At spring the peaks of ozone concentration observed to be at the same height, 50 ppb for all sites. The downwind sites from the power plant stations at Al-Dora and Al-Za'afarania areas record higher ozone peaks compared with up wind sites. It can be concluded that the effect of power plant stations in forming ozone is larger than traffic load.The comparison between the ground level ozone concentrations that measured during the research period in spring and fall, and the ambient air quality standards (AAQS) shows that:•No exceeded levels were observed in spring for all sites.•In fall the AAQS for ozone was exceeded in Al-Za'afarania area at 12: PM, 1: PM, 2: PM and 3: PM, and in Al-Dora at 2: PM

يهدف البحث الى تعيين تراكيز غاز الاوزون عند المستوى الارضي لعدة مناطق في مدينة بغداد . تم اختيارخمسة مناطق وهي منطقة الدورة و منطقة الزعفرانية والتي تمثل مصدر للتلوث النقطي ( بسبب وجود محطات توليد الطاقة الكهربائية) اضافة الى انها مناطق مزدحمة بالمركبات. وتم اختيار حديقة الامة وساحة عدن وساحة الموال كمناطق مزدحمة بالمركبات ( مناطق ذات مصدرخطي للتلوث ). القياسات تمت في فصل الربيع والخريف لان هذي الفترة تمثل افضل فترة لتكون الاوزون. خلال فترة البحث تبين ان اعلى قيمة لتركيز الاوزون ظهرت خلال فصل الخريف: في منطقة الزعفرانية 101 جزءا ً بالبليون كمعدل , في منطقة الدورة 87 جزءا بالبليون كمعدل , وفي مناطق التلوث الخطي 48 جزءا بالبليون كمعدل. ساحة الموال سجلت اعلى قيمة لتراكيز الاوزون لمناطق التلوث الخطي في الخريف والبالغة 68 جزءا بالبليون .اما في الربيع اعلى تركيز للاوزون كان متساويا ً تقريبا لكافة المناطق ,50 جزءا ً بالبليون . في منطقة الدورة والزعفرانية خلال فصل الخريف, القياسات التي تمت في المناطق التي هي باتجاه الريح السائدة اظهرت قيم اعلى من القياسات التي تمت بعكس اتجاه الرياح السائدة . هذا يعطي مؤشر الى ان تأثير محطات توليد الطاقة الكهربائية على تكون الاوزون اكبر من تأثير حمل المركبات. ان المقارنة بين تراكيز الاوزون عند المستوى الارضي خلال فترة البحث مع المحددات القياسية للهواء المحيط بينت انه لا يوجد تجاوز في فصل الربيع , كما بينت انه تم تجاوز المحددات في منطقة الزعفرانية في الساعة الثانية عشر,الواحدة ,الثانية والثالثة بعدالظهر خلال فصل الخريف. وكذلك تم تجاوز المحددات في منطقة الدورة في الساعة الثانية بعد الظهر


Article
Performance of Alternative Refrigerant R431A on Air- Conditioning System under Real Transient Conditions
أداء المبرّدِ البديلِ آر 431 أي على منظومة تكييف الهواء تحت ظروف استجابة عابرة حقيقية

Author: Haider ali hussen
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 10 Part (A) Engineering Pages: 1962-1971
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This paper presents the performances of new ozone-friendly refrigerant (R431a) in air-conditioning system were investigated experimentally and compared with R22 under transient conditions.R431a has no ozone depletion potential and very low greenhouse warming potential of less than 43 (ASHRAE Listed,2007)[1].The variation in refrigeration rate of evaporator, work consumption of compressor and heat rejection rate of condenser with time from the start to stop of the air condition system have been examined. Test results showed that the refrigeration rate of evaporator and heat rejection rate of condenser drops almost parallel to each other, both with a decreasing rate with time. The power consumption on the other hand does not increasing much. The coefficient of performance of R431a decreased from rang 8.96 to 9.28% through (5000 sec) at different ambient temperatures. The refrigeration rate of evaporator decreased by 2.69% through 5000 sec at ambient temperature 30 C° for R431a .The heat rejection rate of condenser decreased by 2.34% through 5000 sec at ambient temperature 30 C° for R431a. Results showed that the coefficient of performance of R431a is 14.67 to 20.34% higher than that of R22. Compressor input power of R431a is 8.39 to 14.19% lower than that of R22 at different ambient temperatures.

هذا البحث يقدم دراسة عملية لاداء منظومة تكييف الهواء باستخدام موائع تبريد جديدة R431a تحت ظروف استجابة عابرة حقيقية بالمقارنة مع الموائع القديمة R22.وسيط تبريد R431a لايؤثر على طبقة الاوزون وكذالك GWP اقل من 34.أظهرت النتائج العملية بان كمية الحرارة الممتصة من قبل المبخر وكمية الحرارة المطروحة من قبل المكثف تنخفض بشكل متوازي. لكن الطاقة المستهلكه من قبل الظاغط من جهة اخرى لا تزداد كثيرأ. معامل الأداء للغاز (R431a) تقل بنسبة 8.96-9.28% خلال 5000 ثانية عند درجاتِ الحرارة البيئيةِ المختلفةِ . كمية الحرارة الممتصة من قبل المبخر تقل بنسبة 2.69% خلال 5000 ثانية عند درجة الحرارة البيئيةِ 30 مئوية للغاز (R431a). كمية الحرارة المطروحة من قبل المكثف تقل بنسبة 2.34% خلال 5000 ثانية عند درجة الحرارة البيئيةِ 30 مئوية للغاز (R431a). معامل الأداء للغاز (R431a) هو أعلى بنسبة 14.67-20.34% بالمقارنه مع غاز(R22). وكذالك أقل أستهلاك للطاقه للغاز (R431a) بنسبة 8.39-14.19% بالمقارنه مع غاز(R22) عند درجاتِ الحرارة البيئيةِ المختلفةِ.


Article
Design an Ozone Generator by Using Dielectric Barrier Discharge

Authors: Hamid H. Al-Jobouri --- Hadeel O. Ismaeel
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2014 Volume: 17 Issue: 1 Pages: 89-94
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

An Ozone generator was designed according to dielectric barrier discharge (DBD) technique with Oxygen as a feed gas for Ozone generating. The effect of the flow rate on the concentration of the Ozone was studied, the flow rate was varied from 0.6 to 5lit/ min for two values of the gap space between electrodes d= 2 and 4 mm, and two values of the electrode area A= 20 and 36 cm2. Also, the effect of the applied voltage on the concentration of the Ozone was studied, the applied voltage was varied from (1- 9 kV) for the same gap space and electrode area values. It is found that the concentration of Ozone produced increases with increasing voltage, and decreases with increasing flow rate.

تم تصميم وتشغيل منظومه لانتاج الاوزون طبقاً لتقنية تفريغ حاجز العزل الكهربائي بأستخدام الاوكسجين كغاز ادخال لتوليد الاوزون، درس تأثير معدل الجريان على تركيز الاوزون المنتج في المنظومه بأخذ قيم مختلفة لمعدل الجريان ما بين (L/min 5- 0.6) لقيمتين مختلفتين للمسافة بين الاقطاب (d=2,4 mm)، وكذلك لقطبين مختلفين في المساحة ((Ae= 20,36 cm2، ايضاُ تم دراسة تأثير الفولتية المسلطة على تركيز الاوزون وذلك بأخذ فولتيات مختلفة بين1-9 kV) ) لنفس المسافة بين الاقطاب ومساحة القطب ولوحظ ان تركيز الاوزون المنتج يزداد بزيادة الفولتية المسلطة ويقل بزيادة معدل الجريان.


Article
Air Quality Over Baghdad City Using Ground and Aircraft Measurements
تقييم نوعية هواء مدينة بغداد باستخدام القياسات الارضية وقياسات الطائرة.

Authors: Ebtesam F.Khanjer ابتسام فاضل خنجر --- Mohammed A.Yosif محمد علي يوسف --- Mathem A.Sultan ميثم عبدالله سلطان
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2015 Volume: 56 Issue: 1C Pages: 839-845
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this paper, the air pollutants concentrations measurements such as Total Suspended Particles(TSP), Carbon Monoxides(CO),Carbon Dioxide (CO2) and meteorological parameters including temperature (T), relative humidity (RH) and wind speed & direction were conducted in Baghdad city by several stations measuring numbered (22) stations located in different regions, and were classified into (industrial, commercial and residential) stations. The results show that the concentrations of pollutants (TSP, CO, and CO2) have exceeded the air quality standards set by World Health Organization (WHO) and Iraqi limitation in the stations of the Baghdad city. The program (ArcGIS) used to prepare maps of air pollution in Baghdad city, as well as MS Excel used for drawing the concentrations of pollutants in ground and to show changed the concentrations with altitude. Aircraft measurements of gaseous pollutants including ozone (O3), Carbone monoxide (CO) , Carbone dioxide (CO2) and the particulate matter concentrations ( PM10 , PM2.5 ) were conducted in the Baghdad city from ( 2 January 2014 to 4 Mars 2014 ),the data of total 10 flight (22 h flight time ),the vertical profile of (CO ,CO2 ,O3 ,PM10and PM2.5 ) have been obtained at different altitude over the Baghdad city covering the lowermost troposphere up to 2100 feet altitude above ground level (AGL) during all flights were obtained by A bell 407 aircraft and A king aircraft. The objective was to characterize the spatial and vertical distributions of these air pollutants.The results indicate that the air pollution levels were severe over the Baghdad city. The pollutants concentrations were generally decreasing with altitude in the boundary layer in the flight measurements .These results are valuable for studying vertical distribution characteristics of gaseous pollutants and particulate matters in the boundary layer over the Baghdad city and for providing important basic data to environmental assessment and decision-making. The reasons for this increasing due to increase in anthropogenic emissions, mainly due to the increase in fossil fuel use for heating, the burning of the fuel used in various types of vehicles, as well as the low quality of fuel and the age of the vehicles, the use of generators, the dry climate, soil erosion, lack of roadside vegetation, paved areas, substantial rise in number of vehicles and poorly maintained vehicles have all been held Responsible.

في هذا البحث تم قياس تراكيز الملوثات الهوائية المتمثلة بالدقائق العالقة الكلية (TSP) واكاسيد الكربون (CO , CO2) في مدينة بغداد من خلال عدة محطات قياس ارضية بلغ عددها(22) محطة موزعة في مناطق مختلفة، وجرى تصنيفها إلى محطات (صناعية وتجارية وسكنية). أظهرت نتائج قياس تراكيز الملوثات الهوائية في مدينة بغداد إن تراكيز الملوثات(TSP,CO,CO2) قد تجاوزت المحددات القياسية المسموح بها محلياً وعالمياً لملوثات الهواء ولمحطات القياس جميعها. وكذلك تم قياس تراكيز الملوثات الهوائية المتمثلة بالدقائق العالقة (PM10,PM2.5) واكاسيد الكربون (CO , CO2)وغاز الازون O3)) في مدينة بغداد من خلالتقسيم مدينة بغداد الى اربع مقاطع جوا حيث استخدمت الطائرة في عملية القياس واظهرت النتائج ان تركيز الملوثات الهوائية في مدينه بغداد عالي وان تركيز الملوثات يقل مع زيادة الارتفاع وان تركيز الملوثات الهوائية له ارتباط بموقع القياس. وجرى استخدام برنامج (ArcGIS 9.2) لإعداد خرائط للملوثات الهوائية.


Article
Pathological Effects of Endosulfan Pesticide on Common Carp Cyprinus carpio
التأثيرات المرضية لمبيد الاندوسلفان في اسماك الكارب العادي Cyprinus carpio

Loading...
Loading...
Abstract

The present study done at the college of Veterinary Medicine University of Baghdad. The chronic toxic effects of endosulfan was investigated with conferments on histopathological effect of infected organ in Cyprinus carpio. Different concentrations of endosulfan 0.0001 µg/L, 0.0002µg/L, 0.0003µg/L, 0.0004µg/L and 0.0005µg/L were used to study the chronic effects of endosulfan exposure to 60 fingerlings for 90 days in fish organs mainly gills, liver, kidney, muscles and brain.Histopathological changes in gills characterized by lamellar fusion, extensive odema of primary lamellar epithelium, telengiectasis of secondary lamellar as well as severe destructive changes of epithelial lamellae while or diffuse necrosis, congestion with marked mononuclear cells infiltrate mainly surrounding bile duct. Kidneys results varying degrees of tubular necrosis with severe congestion and hemosiderosis together with melanomacrophage infiltration. Muscular tissues showed fragmentation and separation of muscle bundles with intramuscular odema with necrotic changes accompanied with distortion of surviving structure. Severe vascular changes were seen in all organs including brain with severe vacuolar changes (spongiosis) of neurons

هدفت الدراسة الى معرفة التأثير المرضي السمي المزمن لمبيد الأندوسلفان في أسماك الكارب العادي ، إذ تم تعريض 60 أصبعية الى خمسة تراكيز سمية (0.0002 µg/L, 0.0001µg/L 0.0005µg/L , 0.0004µg/L,0.0003µg/L) ولمدة 90 يوماً. تميزت التغيرات المرضية النسجية في الغلاصم باندماج والتصاق الصفائح الغلصمية وخزب شديد في ظهارة الصفائح الأولية مع تبقع الشعيرات المتوسعة في الصفائح الغلصمية الثانوية فضلاً عن التدمير الشديد في ظهارة الصفائح الغلصمية ، أما نسيج الكبد فتميز بوجود التنكس الأستسقائي مصحوبآ بالتنكس الدهني ونخر بؤري منتشر ونزف مع ارتشاح الخلايا وحيدة النواة لاسيما حول قناة الصفراء أما الكلية فأظهرت درجات متفاوتة مابين التنكس النبيبي وحدوث النخر المصحوب باحتقان الأوعية وحدوث الهيموسدرية مع أرتشاح خلايا البلاعم الميلانينية في حين بينت النتائج للأنسجة العضلية تجزء وأنفصال الحزم العضلية و خزب مابين العضلات مع نخر مصحوب بتحريف التراكيب العضلية المتبقية وأظهرت النتائج وجود تغيرات وعائية شديدة في أغلب الأعضاء ولاسيما الدماغ مصحوبة بتغيرات فجوية شديدة مع خزب في العصبات


Article
The Efficiency of Using Ozone Gas and Heat to Control Larvae and Adult Stage of Red Flour Beetle, Tribolium castaneum (Herbst) (Coleoptera: Tenebrionidae)
كفاءة استعمال غاز الاوزون والحرارة في مكافحة دور اليرقات والبالغات لخنافس الطحين الحمراء Tribolium castaneum (Herbst) (Coleoptera: Tenebrionidae)

Author: F. A. Sabeat فلاح عبود سابط
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2017 Volume: 14 Issue: 4 Pages: 677-681
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The effect of ozone gas with temperatures 35. 40 and 45 Celsius to control on larval and adult stages of Tribolium castaneum was tested and at time of exposure 1.0, 3.0, 7.0, 9.0, 11.0, 13.0 hours and the level of relative humidity prevailing during the test 45 ± 1%. Results showed significant differences between the exposure times, when the percentage of mortality 100% between larvae (primary, intermediate and advanced) in the treatment effect at a temperature of 35 Celsius with ozone gas at exposure time to 9.0, 11.0, 11.0 hours for the three ages respectively, and adult (male and female) in the same treatment when the three heat degrees had given ratios the total mortality reached 100% of both males at exposure time to 7.0 ,3.0, 1.0 hour respectively and females at exposure time 9.0 ,7.0 ,1.0 hour respectively, While completely failed under the effect of a heat treatment at temperatures of 35 Celsius for both stages respectively, while the effect was clear when the temperature is 45 Celsius where the of total mortality of 100% when the heat treatment of the stage of the larval and adult at the time 7.0, 3.1, 1.0 hour respectively. This means that the combined effect of ozone gas with temperatures has resulted in the reduction of the time needed to get the total mortality in both insect stages and significantly influential and that mortality rates in the two stages were increasingly higher degree of exposure used heat and high heat was the lead in reducing the time of exposure and even access to the total mortality.

اختبر تاثير المعاملات بغاز الاوزون مع درجات الحرارة 40,35و 45 سيلزية في مكافحة دورياليرقات والبالغات لحشرة Tribolium castaneum وعند الاوقات الزمنية للتعريض 13.0,11.0,9.0,7.0,3.0,1.0ساعة، وان بلغت مستوى الرطوبة النسبية السائدة في اثناء الاختبار 1±45% ،اظهرت النتائج ان هناك فروقا معنوية بين هذه الاوقات ، ففي الوقت الذي وصلت فيه نسبة القتل الى 100% بين دوراليرقات (الاولية والمتوسطة والمتقدمة) في معاملة غاز الاوزون والحرارة عند درجة حرارة 35 سيلزية عند اوقات التعريض 11.0,9.0, 11.0 ساعة للاطوار الثلاثة على التوالي، والبالغات (الذكور و الاناث) في المعاملة نفسها عند الدرجات الحرارية الثلاث التي اعطت نسب قتل كلي 100% لكل من الذكور عند اوقات التعرض 1.0,3.0,7.0 ساعة على التوالي والاناث عند اوقات التعرض و 1.0,7.0,9.0ساعة على التوالي ،بينما فشلت كليا تحت تأثير معاملة الحرارة عند درجات الحرارة 35 سيلزية لكلا الدورين على التوالي ، كما لوحظ التأثير عند درجة الحرارة 45 سيلزيه قد بلغت نسبة القتل الكلي100% عند معاملة الحرارة المنفردة في دور اليرقات (الاولية ، المتوسطة ،المتقدمة) والبالغات(الذكور و الاناث) بالوقت 1.0ساعة وهذا يعني ان التأثير المشترك لغاز الأوزون مع درجات الحرارة قد ادى الى اختزال الوقت اللازم لحصول القتل الكلي في دوري الحشرة وبشكل ملحوظ ومؤثر، و ان نسب القتل في الدورين المعامل قد ازدادت كلما ارتفعت درجة حرارة التعريض المستعملة وان ارتفاع الحرارة كان يؤدي في تقليص اوقات التعرض الى حين الوصول الى القتل الكلي

Listing 1 - 10 of 22 << page
of 3
>>
Sort by
Narrow your search

Resource type

article (22)


Language

English (14)

Arabic (7)

Arabic and English (1)


Year
From To Submit

2018 (2)

2017 (3)

2016 (3)

2015 (5)

2014 (3)

More...