research centers


Search results: Found 4

Listing 1 - 4 of 4
Sort by

Article
Phosphorus Removal from Water and Waste Water by Chemical Precipitation Using Alum and Calcium Chloride

Loading...
Loading...
Abstract

Phosphorus is usually the limiting nutrient for eutrophication in inland receiving waters; therefore, phosphorus concentrations must be controlled. In the present study, a series of jar test was conducted to evaluate the optimum pH, dosage and performance parameters for coagulants alum and calcium chloride. Phosphorus removal by alum was found to be highly pH dependent with an optimum pH of 5.7-6. At this pH an alum dosage of 80 mg/l removed 83 % of the total phosphorus. Better removal was achieved when the solution was buffered at pH = 6. Phosphorus removal was not affected by varying the slow mixing period; this is due to the fact that the reaction is relatively fast.The dosage of calcium chloride and pH of solution play an important role in phosphorus removal. The removal efficiency increases with increasing pH, and the optimum dosage of CaCl2 was 60 mg/l. Alum demonstrated much better results in phosphorus removal than CaCl2.

يعتبر الفسفور من المواد الملوثة للماء والتي تؤدي الى عملية التحول في الحياة المائية (Eutrophication) ولهذا فمن الضروري السيطرة على تركيزه في الماء.في هذه الدراسة تم اجراء سلسلة من التجارب باستخدام جهاز (jar test) لايجاد افضل قيمة للرقم الهيدروجيني وكمية المادة الكيمياوية المضافة.لقد وجد ان افضل قيمة للرقم الهيدروجيني في حالة استخدام الشب هو من 5.5-6 وافضل كمية مستخدمة هي 80 ملغم/لتر والتي تعمل على ازالة 83% من كمية الفسفور الذائب في الماء وكانت عملية الازالة افضل عندما تمت السيطرة على قيمة الرقم الهيدروجيني على قيمة 6.لم تتأثر كفاءة الازالة بتغيير الزمن اللازم للتحريك البطئ و ذلك لكون التفاعل سريع.اما في حالة ازالة الفسفور باستخدام كلوريد الكالسيوم فان كمية الكلوريد المضاف والرقم الهيدروجيني للمحلول كان لها دور مهم في عملية الترسيب وان افضل قيمة للرقم الهيدروجيني هو 11 وافضل قيمة لكمية الكلوريد هي 60 ملغم/لتر.دلت النتائج على ان الشب اعطى كفاءة افضل في عملية ترسيب الفسفور بالمقارنة مع كلوريد الكالسيوم.


Article
Effect of Using Anaerobic Selectors on the Performance of Continuous Flow Activated Sludge Systems
تأثير استخدام الأحواض الانتقائية اللاهوائية على كفاءة أنظمة الحماة المنشطة المستمرة الجريان-عربي

Authors: Dr. Kossay K. Al-Ahmady د. قصي كمال الدين الأحمدي --- HananHaqeIsmaeel حنان حقي إسماعيل
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2013 Volume: 21 Issue: 6 Pages: 88-99
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

AbstractIn this research, four experimental plants have been constructed and operated in order to study the impact of using the anaerobic selectors on the behavior and efficiency of the extended aeration activated sludge system. The study program was divided into three stages. In the first stage, the experimental plants were run on the hydraulic retention time of the aerobic reactor equals to (32) hours, whereas, the hydraulic retention times in the biological aerobic reactors for the second and the third stages were (24 and 18) hours respectively. The results of the study revealed that; adding the anaerobic selectors improves the properties of the aerobic biological treatment in terms of removing soluble organic materials (CODs) and the efficiency of removing phosphor (PO4). The results also showed that,the organic and phosphorus removal efficiency increases with increasing the hydraulic retention time of the anaerobic selector. In contrast the values of the sludge volume index (SVI) decreases with this increasing. Higher removal efficiencies were recorded in the experimental stations that include anaerobic selector, which operates on a hydraulic retention time of (120 min) followed by the plant with the selector of (60 min) detention time and in the last place the plant that include selector, which operates on a hydraulic retention time of (30 min).Keywords:Anaerobic selector, Activated sludge, HDT,SVI, Phosphorus removal, Organic removal

الملخصتم في هذا البحث إنشاء وتشغيل محطة اختباريه تتكون من أربعة مفاعلات بيولوجية لغرض دراسة تأثير استخدامالأحواض الانتقائية اللاهوائية على سلوك وكفاءة أداء وحدات الحماة المنشطة المستمرة الجريان.قسم برنامج العمل إلى ثلاثة مراحل تم في المرحلة الأولى تشغيل الوحدات الاختبارية على وقت تعويق هيدروليكي للمفاعل الهوائي يساوي (32 ساعة)، في حين كان وقت التعويق الهيدروليكي في المفاعل البيولوجي الهوائي وللمرحلتين الثانية والثالثة مساويا لـ (24 و 18 ساعة) وعلى التوالي.أثبتت نتائج البحث إن إضافة الأحواض الانتقائية اللاهوائية يحسن من خصائص المعالجة البيولوجية الهوائية من حيث إزالة المواد العضوية الذائبة والفسفور والخصائص الترسيبية للحماة البيولوجية. كذلك أظهرت النتائج أن هناك علاقة بين زيادة وقت التعويق الهيدروليكي للحوض الانتقائي اللاهوائي وكفاءة إزالة كل من المواد العضوية والفسفور وتحسين خصائص الحمأة حيث تزداد كفاءة إزالة المواد العضوية والفسفور مع زيادة وقت التعويق الهيدروليكي للأحواض الانتقائية اللاهوائية، بالمقابل تقل قيمة معامل دليل الحماة الحجمي مع زيادة وقت التعويق الهيدروليكي للأحواض الانتقائية،حيث لوحظ أن أفضل كفاءة إزالة واقل معامل دليل حماة حجمي (SVI) تحقق في المحطة الاختبارية الحاوية على حوض انتقائي يعمل بوقت تعويق يساوي (120) دقيقة تليها المحطة الاختبارية ذات الحوض الانتقائي اللاهوائي الذي يعمل بوقت تعويق يساوي (60) دقيقة ثم المحطة ذات الحوض الانتقائي الذي يعمل بوقت تعويق يساوي (30) دقيقة.


Article
Effect of Continuous and Intermittent Aeration Modes on the Efficiency of the Continuous Flow Extended Aeration Activated Sludge Systems
مقارنة تأثیر أسلوبي التھویة المستمرة والتھویة المتقطعة على كفاءة أنظمة الحمأة المنشطة ذات التھویة المطولة والجریان المستمر

Authors: Kossay K. Al-Ahmady قصي كمال الدین الاحمدي --- Ammar A. Al-Sultan عمار عبدلله السلطان
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 13 Part (A) Engineering Pages: 498-512
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In this research an experimental plant was constructed and operated in order to study the efficiency of the intermittent aeration activated sludge system that operated at the ratio of (On/Off aeration times) (15min/15min), (30min/30min), (60min/60min), (90min/90min) and (120min/120min) and compare their performance with the continuous flow extended aeration activated sludge. The results of the study revealed that; extended aeration reactor is more efficient in removing organic matter than the intermittent aeration reactors. At the hydraulic detention times of (24, 18 and 32), 100%, 65% and 100% of effluent readings had organic concentration less than the acceptable effluent level in compare to 75%, 60% and 80% at the (90min/90min) reactor. In comparison of On/Off aeration times, (90min/90min) reactors provide the best organic removal. All readings from the extended aeration and (15min/15min), (60min/60min), and (90min/90min) reactors were within the acceptable level for effluent suspended solids while the effluent concentrations from the (120min/120min) reactors were higher. The results also indicated that, intermittent aeration reactors are better in removing phosphorous than the extended aeration. At the detention times of 24 and 18 hours, 8% and 6% of readings from the extended aeration reactors had (PO4 ≤ 5 mg/l) in compare to 90% and 52% of readings from the (60min/60min) reactor. At detention time of 32 hours, 32% of readings from the extended aeration reactor had (PO4 ≤ 2 mg/l) in compare to 72% for the (60min/60min) reactor. Higher phosphorus removals were recorded at (60min/60min) reactors.

تم في هذا البحث دراسة تأثير التهوية المتقطعة على كفاءة أنظمة الحمأة المنشطة ذات الجريان المستمر وذلك من خلال إنشاء وتشغيل محطة اختبارية تعمل بنظام الجريان المستمر والتهوية المتقطعة وبأوقات تشغيل وإيقاف تهوية (15min/15min)، (30min/30min)،(60min/60min) ،(90min/90min)،(120min/120min) ومقارنتها مع نظام الحمأة المنشطة ذو الجريان المستمر والتهوية المطولة حيث استخدمت مياه المطروحات الصناعية لمصنع أدوية نينوى مصدرا للفضلات السائلة. أثبتت نتائج البحث أن نظام التهوية المطولة ذو كفاءة أعلى في إزالة المواد العضوية من نظام التهوية المتقطعة، حيث كانت 100% و 65 % و 100% من القراءاتلتراكيز المياه الخارجة من مفاعلاتالتهوية المطولة العاملة بأوقات مكوث هيدروليكي (24، 18 و 32) ساعة تقع ضمن محددات الطرح المحلية مقابل 75% و 60% و 80% لمفاعلات التهوية المتقطعة (90min/90min) العاملة بنفس اوقات المكوث وعلى التوالي،وكان افضل تشغيل متقطع لإزالة المواد العضوية هو (90min/90min). وكانت جميع القراءات المسجلة لتراكيز المواد الصلبة العالقة الخارجة من مفاعلات التهوية المطولة والتهوية المتقطعة (15min/15min)،(60min/60min) و (90min/90min)ضمن حدود مواصفات الطرح المعتمدة، كماتفوقتمفاعلات التهوية المستمرة على مفاعلات التهوية المتقطعة من حيث انخفاض تراكيز المواد الصلبة العالقة في المياه الخارجة،كذلككانت الدورات الطويلة لتشغيل وإيقاف التهوية (120min/120min) ذات كفاءة اقل من حيث تراكيزهذه المواد. كما واثبتت النتائج ان مفاعلاتالتهوية المتقطعة افضلمن مفاعلات التهوية المستمرة في إزالة الفسفور حيث كانت 8% و 6% من تراكيز الفوسفات في المياه الخارجة من مفاعلات التهوية المطولة العاملة بأوقات مكوث هيدروليكي (24 و 18) ساعة اقل او يساوي 5 ملغم/لتر، مقابل 90% و 52% لمفاعلات التهوية المتقطعة (60min/60min) العاملة بنفس اوقات المكوث وعلى التوالي،وكانت 32% من تراكيز المياه الخارجة من مفاعل نظام التهوية المطولة العاملة بوقت مكوث هيدروليكي 32 ساعة ذات تركيز فوسفات اقل او يساوي 2 ملغم/لتر مقابل 72% لمفاعل التهوية المتقطعة (60min/60min). وان أفضل تشغيل متقطع لإزالة الفسفور هو (60min/60min).


Article
Kinetic Study of the Recovery of Phosphorus from Wastewater by Calcium Hydroxide Solution
دراسة حركية تفاعل الاسترجاع للفسفور من المياه الصناعية باستخدام محلول هيدروكسيد الكالسيوم

Authors: Shams Asem Mahdi شمس عاصم مهدي --- Raghad Fareed Qasim رغد فريد قاسم
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2019 Volume: 25 Issue: 6 Pages: 19-29
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This research presents a study for precipitating phosphorus (as phosphate ion) from simulated wastewater (5ppm initial concentration of phosphorus) using calcium hydroxide Ca(OH)2 solution. The removal of phosphorus by Ca (OH)2 solution is expected to be very effective since the chemical reaction is of acid-base type but Ca(OH)2 forms complex compound with phosphate ions called. Hydroxyapatite Ca5 (PO4)3OH. hydroxyapatite is slightly soluble in water. This research was directed towards sustainable elements as phosphorus. Kinetics of the dissolution reaction of hydroxyapatite was investigated to find the best factors to recover phosphorus. The effect of concentration of Ca(OH)2 (180- 380 ppm) on phosphorus precipitation on the outputs like the residual phosphorus concentration in the simulated solution, the percentage removal of phosphorus and the weight of the precipitate was also studied. The residual phosphorus decreased with increasing Ca(OH)2 concentration while the percentage removal, as well as the weight of the precipitate, increased with increasing Ca(OH)2 concentration at constant temperature and mixing speed. The best Ca(OH)2 concentration was obtained depending on the lowest amount of the residual phosphorus concentration. The best value obtained was 230 ppm at a fixed mixing speed of 400 rpm and a temperature of 20°C. The best value for Ca(OH)2 concentration under fixed stirring speed and temperature was applied on a real wastewater taken from the detergent factory. The percentage removal was 30. 69% due to the complexity of the real sample. Oxalic acid was chosen to dissolve hydroxyapatite because it is an organic acid, less hazardous than mineral acids and of less cost. Kinetics of the dissolution reaction of hydroxyapatite in (160 ppm) concentration oxalic acid under ambient conditions (20°C and 1 atm (and mild stirring (200 rpm) was studied using the differential method for determining the order of the reaction which was 0.4296 and the rate constant 0.0743 (L/mg)-0.5704. min-1. The reaction was considered as a rate-controlled reaction.

هذا البحث يقدم دراسة لإزالة الفسفور (كأيونات الفسفور) من مياه مطروحة محاكاة بتركيز ابتدائي للفسفور 5 جزء بالمليون باستخدام محلول هيدروكسيد الكالسيوم. ان ازالة الفسفور باستخدام محلول هيدروكسيد الكالسيوم يتوقع ان تكون فعالة جدا لان التفاعل الكيميائي هو من نوع حامض – قاعدة لكن هيدروكسيد الكالسيوم يكون مركب معقد مع ايونات الفوسفات يسمى هيدروكسي ابتايت Ca5(PO4)3 OH. هذا المركب قليل الذوبان في الماء. هذا البحث وجه لدراسة العناصر المستدامة مثل الفسفور. درست حركية تفاعل اذابة الهيدروكسي ابتايت في الماء لإيجاد أفضل الطرق لاسترجاع الفسفور. ايضا درس تأثير تركيز Ca(OH)2 (180-380 ملغرام/لتر) على ترسيب الفسفور مضافا الى الماء في دورق على مخرجات مثل: تركيز الفسفور المتبقي، النسبة المئوية لإزالة الفسفور ووزن الراسب. تبين ان تركيز الفسفور المتبقي يقل بزيادة تركيز هيدروكسيد الكالسيوم لكن النسبة المئوية للإزالة بالإضافة الى وزن الراسب يزداد بزيادة تركيز هيدروكسيد الكالسيوم بثبوت درجة الحرارة وسرعة المزج. تم الحصول على أفضل قيمة لتركيز هيدروكسيد الكالسيوم بالاعتماد على اقل قيمة لتركيز الفسفور المتبقي. أفضل قيمه كانت 230 ملغرام/لتر بثبوت سرعة المزج على 400 د/ثانيه ودرجه الحرارة 20 درجه مئوية. طبقت أفضل قيمة لتركيز هيدروكسيد الكالسيوم بثبوت سرعة الخلط ودرجة الحرارة على ماء مطروح حقيقي مأخوذ من معمل المنظفات. نسبة الإزالة كانت 30.69% بسبب تعقيد النموذج الحقيقي. اختير حامض الاوكزاليك لإذابة الهيدروكسي ابتايت لأنه حامض عضوي، اقل خطورة من الحوامض المعدنية، اقل كلفة. تم دراسة حركية تفاعل الاذابة لهيدروكسي ابتايت في (160 ملغرام/لتر) تركيز حامض الاوكزاليك تحت ظروف المحيط (20 درجة مئويه, ضغط 1 جو) و سرعة خلط معتدلة ( 200 د/دقيقه ) باستخدام الطريقة التفاضلية لتحديد مرتبة التفاعل والتي كانت 0.496 وثابت سرعة التفاعل 0.0743 (لتر/ملغرام)-0.5704 دقيقة-1 . لذألك اعتبر التفاعل من التفاعلات المسيطر عليها من النسبة التفاعلية.

Listing 1 - 4 of 4
Sort by
Narrow your search

Resource type

article (4)


Language

Arabic (2)

English (2)


Year
From To Submit

2019 (1)

2014 (1)

2013 (1)

2009 (1)