research centers


Search results: Found 8

Listing 1 - 8 of 8
Sort by

Article
SOLAR PHOTOCATALYTIC TREATMENT OF SIMAZINE FROM SYNTHETIC WASTEWATER

Author: Manar Banwan Hasan
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2017 Volume: 21 Issue: 5 Pages: 200-212
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

: In this research, a solar pilot plant designed for solar photocatalytic applications have been used to investigate the feasibility of simazine degradation in an aqueous solution. Simazine degradation was investigated in both homogeneous and heterogeneous photocatalysis systems by photo-Fenton and titanium dioxide, respectively. Simazine remediation was studied at different reagent doses to identify the optimum condition, H2O2 (400-2400 mg/L), Fe2+ (5-30 mg/L) and TiO2 (100-500 mg/L). The optimum remediation conditions for solar homogenous system was observed at H2O2 and Fe2+ concentrations of 1200 and 20 mg/L, respectively. The best remediation conditions for solar heterogeneous system was identified at TiO2 and H2O2 concentrations of 300 and 2000 mg/L, respectively. The best COD removal efficiency at both homogenous and heterogeneous systems were 43.8% and 43%, respectively. Simazine removal were about 96.7% and 92% for homogenous and heterogeneous systems, respectively.

في هذه الدراسة تم استخدام منظومة تعمل بنظامي الاكسدة المتقدمة المتجانس والغير متجانس باستخدام الطاقة الشمسية في دراسة تحلل المبيد العشبي (Simazine) في المحاليل المائية. وقد تم ذلك تحت تأثير تراكيز مختلفة من المواد التالية: H2O2 (400-2400 mg/L) , TiO2 (100-500 mg/L) .Fe2+ (5-30 mg/L)بلغت نسبة إزالة ال COD في نظام الاكسدة المتجانس والغير متجانس 43.8% و43% على التوالي. في هذه الدراسة كانت الظروف المثلى لإزالة المبيد هي عند تركيز 1200 ملغ/لتر من H2O2 و 20 ملغم/لتر من Fe2+ باستخدام الاكسدة المتقدمة المتجانسة في حين ان الظروف المثالية للإزالة باستخدام نظام الاكسدة المتقدمة الغير متجانس كانت عند تركيز 300 ملغم/لتر TiO2 و 2000 ملغم/لتر من H2O2. أفضل نسبة إزالة لل COD في نظامي الاكسدة المتقدمة المتجانس والغير متجانس كانت 43.8% و43% على التوالي. نسبة إزالة المبيد العشبي Simazine بلغت 96.7% و92% في نظامي الاكسدة المتقدمة المتجانس والغير متجانس على التوالي.


Article
Treatment of Furfural Wastewater by (AOPs) Photo-Fenton Method
معالجة المياه الملوثة بالفورفورال باستخدام عمليات الاكسدة المتقدمة(طريقة الفوتوفنتون)

Authors: Yasmen A. Mustafa ياسمين عبد العزيز مصطفى --- Raid Raho Omran رائد رهو عمران
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2015 Volume: 21 Issue: 3 Pages: 129-141
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The objective of this study is to investigate the application of advanced oxidation processes (AOPs) in the treatment of wastewater contaminated with furfural. The AOPs investigated is the homogeneous photo-Fenton (UV/H2O2/Fe+2) process. The experiments were conducted by using cylindrical stainless steel batch photo-reactor. The influence of different variables: initial concentration of H2O2 (300-1300mg/L), Fe+2(20-70mg/L), pH(2-7) and initial concentration of furfural (50-300 mg/L) and their relationship with the mineralization efficiency were studied. Complete mineralization for the system UV/H2O2/Fe+2 was achieved at: initial H2O2 = 1300mg/L, Fe+2 = 30mg/L, pH=3, temperature =30oC and irradiation time of 60 min, for 300mg/L furfural concentration. The results have shown that the oxidation reagent H2O2 plays a very important role in the furfural mineralization.

الهدف من هذا البحث دراسة معالجة المياه الملوثة بمادة الفورفورال باستخدام احد طرق الاكسدة المتقدمة(AOPs) . حيث تم استخدام نظام الاكسدة المتجانسة (UV/H2O2/Fe+2, photo-Fenton process). التجارب تم اجرائها باستخدام مفاعل اسطواني مصنوع من الفولاذ المقاوم للصدأ يعمل بنظام الوجبات. تاثيرالمتغيرات المختلفة مثل: التركيز الابتدائي لل H2O2 1300mg/L) (300-و Fe+2(20-70mg/L) وpH (2-7) والتركيز الابتدائي للفورفورال(50-300 mg/L) تم دراستها ودراسة علاقتها مع كفاءة التحلل للفورفورال. بينت التجارب ان التحلل الكامل للفورفورال بتركيز mg/L 003 تم باستخدام H2O2=1300mg/L وFe+2 =30mg/L وبظروف حامضية pH=3 ودرجة حرارة 30oC وبوقت 60 دقيقة . النتائج بينت ان تركيز العامل المؤكسد H2O2 له دور مهم في عملية الاكسدة.


Article
Degradation of Brilliant Green by Using a bentonite Clay- Based Fe Nano Composite Film as a Heterogeneous Photo- Fenton Catalyst.
دراسة حركية للتفكك الضوئي نوع (فنتون) المحفز لصبغة Brilliant Green باستخدام طين البنتونايت المزود بالحديد النانوي بسطح غير متجانس للتفاعل الضوئي المحفز

Authors: Khulood Abid Saleh AL-Saade خلود عبد صاحب السعدي --- Shatha Fadel Al- Saidi شذى فاضل السعيدي --- Hamdia Hateem Juad حمدية حا تم جواد
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2016 Volume: 13 Issue: 3 Pages: 524-530
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This paper aims to study the chemical degradation of Brilliant Green in water via photo-Fenton (H2O2/Fe2+/UV) and Fenton (H2O2/Fe2+) reaction. Fe- B nano particles are applied as incrustation in the inner wall surface of reactor. The data form X- Ray diffraction (XRD) analysis that Fe- B nanocomposite catalyst consist mainly of SiO2 (quartz) and Fe2O3 (hematite) crystallites. B.G dye degradation is estimated to discover the catalytic action of Fe- B synthesized surface in the presence of UVC light and hydrogen peroxide. B.G dye solution with 10 ppm primary concentration is reduced by 99.9% under the later parameter 2ml H2O2, pH= 7, temperature =25°C within 10 min. It is clear that pH of the solution affects the photo- catalytic degradation of B.G dye. All the conditions above have been studied to reach the optimum operation condition for the two processes Fenton and photo- Fenton. The B.G degradation process follows first- order reaction rules. Photo- Fenton process causes a more efficient oxidation rate than the Fenton process. So, the photo- Fenton degradation is an effective and economic process by producing higher percentage of degradation and mineralization in short radiation time.

يهدف هذا البحث الى دراسة التفكك الضوئي لصبغة Brilliant Green (B.G.) بالماء باستخدام تفاعل فينتون الضوئي (UV/ H2O2/(Fe+2 وتفاعل فينتون (H2O2/Fe+2) حيث تم دقائق نانوية من (الحديد-بنتونايت) كسطح فعال وقد طلي السطح الداخلي لخلية مختبرية. وقد اثبتت تحليل الاشعة السينية وجود SiO2 (الكوارتز) بصورة رئيسية ووجود الحديد النانوي بهيئة Fe2O3 (الهيماتايت) البلوري. تم تقدير فعالية السطح المحضر (Fe-B) كعامل مساعد باستخدام الصبغةB.G ودرست قابليته على تكسير هذه الصبغة من المحلول بوجود ضوء الاشعة الفوق البنفسجية نوع C وبوجود بيروكسيد الهيدروجين. لقد تم متابعة محلول صبغة B.G ذات تركيز ابتدائي 10 اجزاء بالمليون عند رقم هيدروجين pH=7 وعند درجة حرارة 25 درجة مئوية ولوحظ ان 99.9% من الصبغة قد ازيلت او تكسرت خلال 10 دقائق.ان للرقم الهيدروجيني pH تاثير كبير في التكسير الضوئي المحفز لصبغة B.6 كما تبين من خلال هذه الدراسة. ثم دراسة كل الظروف وثم الحصول على القيم المثلى للعمليتين (فينتون الضوئي)و(فينتون). ان عملية تجزء صبغة B.6 في المحلول المائي تتبع تفاعل المرتبة الاولى. وتفاعلات الفينتون الضوئي تؤدي الى كفاءة اكسدة عالية اكثر من مثيلاتها لتفاعل فينتون دون ضوء. وبالتالي تعتبر تفاعلات فينتون الضوئية عملية فعالة و اقتصادية يمكن ان تزيد من نسبة تكسير وازالة الملوثات بزمن تشعيع قصير.


Article
REMOVAL OF VEGETABLE OIL FROM WASTEWATER BY PHOTO-FENTON PROCESS
ازالة الزيوت النباتية من المياه الملوثة بواسطة الاكسدة المتقدمة (Photo-Fenton)

Authors: Aola H. F. Tahir --- Nagam Obeid --- Shatha Abdul Jabbar
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2016 Volume: 20 Issue: 3 Pages: 36-46
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The present work evaluated the use of photo-Fenton process (UV/H2O2/Fe2+) for the treatment of oily aqueous solution using batch system. The photo-Fenton best operating conditions, such as time, pH, oil concentration, H2O2 dosage, Fe2SO4.7H2O concentration and temperature were evaluated. The efficiency of the treatment was measured by COD (chemical oxygen demand) removal. The results showed that the optimum pH for the photo-Fenton process was equal to 3. The increase in H2O2 application resulted in an efficiency increase of the photo-Fenton process at 800 mg/l, the optimum Fe2SO4.7H2O concentration found was 60 mg/l. It was found that the optimal temperature for the Photo-Fenton processes 30oC. Oil concentrations were varied and lower concentration was removed more efficient. Photo-Fenton process gave a maximum COD reduction of 80.59 % (COD from 2684 to 521 mg/l) after the total reaction time (180 min) at optimal operation conditions.

: تم دراسة عملية معالجة المياه الملوثة بالزيوت النباتية بطريقة الاكسدة المتقدمة(AOP) . حيث استخدم طريقة الـ .(UV/H2O2/Fe2+) عدة عوامل تاثر على التفاعلات لذلك تم دراستها معظمها و لعله اهمها هي تركيز بيروكسيد الهيدروجين H2O2 وتركيز كبريتات الحديد الثنائي Fe2SO4.7H2O كعامل مساعد. لقد تم ايضا دراسة الوقت ودرجة الحموضة والحرارة وتركيز الزيوت في المياه الملوثة. تم احتساب نسبة الازالة بالاعتماد على المتطلب الاوكسجين الكيميائي COD. اظهرت النتائج ان افضل درجة حموضية تساوي 3 في افضل وقت وهو 180 دقيقة. كما ان زيادة تركيز بيروكسيد الهيدروجين ادى الى زيادة في نسبة الازالة عند 800 mg/l و افضل تركيز لكبيرتات الحديد الثنائي كانت 60 mg/l. كما وجد ان افضل درجة حرارة لاجراء التفاعل هي 30 درجة سيليزية و كانت نسبة ازالة 80.59 % (COD من 2684 mg/l الى 521 mg/l ) في 180 دقيقة عند تركيز 1000 mg/l زيت. اظهرت النتائج بان هذه الطريقة قد تكون واعدة لازالة الزيوت النباتية في المصانع.


Article
Removal of 4-Chlorophenoles from Simulated Wastewater by Advanced Oxidation Processes

Authors: Yasmen Abdul Mustafa --- Ahmed Hameed Shihab
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2012 Volume: 18 Issue: 10 Pages: 1115-1127
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The degradation and mineralization of 4-chlorophenol (4-CP) by advanced oxidation processes (AOPs) was investigated in this work, using both of UV/H2O2 and photo-Fenton UV/H2O2/Fe+3 systems. The reaction was influenced by the input concentration of H2O2, the amount of the iron catalyst, the type of iron salt, the pH and the concentration of 4-CP.A colored solution of benzoquinon can be observed through the first 5 minutes of irradiation time for UV/H2O2 system when low concentration (0.01mol/L) of H2O2 was used. The colored solution of benzoquinon could also be observed through the first 5 minutes for the UV/H2O2/Fe+3 system at high concentration (100ppm) of 4-CP. The results have shown that adding Fe+3 to the UV/H2O2 system enhanced the rate of 4-CP oxidation at a molar ratio of H2O2/Fe+3/4-CP equals to 13/0.4/1 by a factor of 7. This reduced the consumption of H2O2 by a factor of 6 and the irradiation time required for complete degradation was reduced by a factor of 6. The experimental results have shown that the optimum reagents for a complete degradation of 4-CP(50ppm) were H2O2.=0.005mol/L, Fe+3=0.16*10-3 mol/L under acidic condition (pH=3) and irradiation time of 15 min for the UV/H2O2/Fe+3 system with a molar ratio of H2O2/Fe+3/4-CP equals to 13/0.4/1.

تم التحقق من فاعلية استخدام طرق الأكسدة الحديثة ((AOPs للنظامين UV/H2O2 وUV/H2O2/Fe+3 لأكسدة وتحلل مادة الكلوروفينول ((4-CP . التفاعل تأثر باختلاف الكميات المضافة من بيرو كسيد الهيدروجينH2O2)), كميـــــة الحديد كعامل مساعد ,نوعية العامل المساعد Fe+3 وFe+2 , pH و تراكيز المحلول للكلوروفينول . المواد الملونة متمثلة بال ( benzoquinone ( تم ملاحظتها بعد 5دقائق من بدأ التجربة لنظام UV/H2O2عند استعمال تركيز قليل لبيروكسيد الهيدروجين (mol/L 0.01(. كذلك تم ملاحظة ظهور المواد الملونة بعد 5 دقائق من بدأ التجربة لنظام UV/H2O2/Fe+3 عند استعمال تراكيز عالية من الكلوروفينول (100ppm). النتائج بينت ان إضافة الحديد (Fe+3) كعامل مساعد الى لنظام UV/H2O2 وبنسبة مولارية 13/0.4/1 ل H2O2/Fe+3/4-CP أعطت تحلل أعلى بمقدار 7 مرات وأدت إلى تقليل مادة إل H2O2 المضافة بمقدار 6 مرات وان الزمن اللازم للوصول الى التحلل الكامل انخفض بمقدار6 مرات.التراكيز المثلى اللازمة للحصول على تـــحلل كامل للكلوروفينول بتركيز50 ppm هي Fe+3=0.16*10-3mol/L , H2O2=0.005mol/L عند وســط حامضـي pH = 3 وبزمن 15دقيــقة للنــظام UV /H2O2 /Fe+3 وبنسبة مولارية 13 /0.4 /1.


Article
Treatment of Wastewater Contaminated with Pesticide (Alachlor) by Solar Enhanced Advanced Oxidation Processes
معالجة المياه الملوثة بالمبيد (الاكلور) باستخدام عمليات الاكسدة المتقدمة المعززة بالطاقة الشمسية

Authors: Ahmad Benwan Hassan احمد بنوان حسن --- Yasmen Abdulaziz Mustafa ياسمين عبد العزيز مصطفى
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2015 Volume: 21 Issue: 11 Pages: 130-144
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The degradation performance of aqueous solution of pesticide Alachlor has been studied at solar pilot scale plant in two photocatalytic systems: homogeneous photocatalysis by photo-Fenton and heterogeneous photocatalysis with titanium dioxide. The pilot scale system included of compound parabolic collectors specially designed for solar photocatalytic applications, and installed at University of Baghdad, Department of Environmental Engineering back yard. The influence of different concentrations, H2O2 (200-2400 mg/l), Fe+2(5- 30 mg/l) and TiO2 (100-500 mg/l) and their relationship with the degradation efficiency were studied.The COD removal efficiency for homogeneous photocatalytic system at the best dosage was found to be 73.7%. The parent pollutant concentrations which were monitored using HPLC decreased to reach zero level at early time of the experiment. For heterogeneous photocatalytic system the COD removal efficiency was found to be 72.7%.

تم دراسة تحلل المبيد (Alachlor) في المحاليل المائية باستخدام منظومة ريادية تعمل بنظام الاكسدة المتقدمة المتجانس (Homogeneous photocatalysis by photo-Fenton) ونظام الاكسدة المتقدمة الغير متجانس (Heterogeneous photocatalysis with titanium dioxide ) باستخدام الطاقة الشمسية (compound parabolic collectors ) .تم دراسة تحلل المبيد تحت تاثير تراكيز مختلفة للمواد H2O2 (200-2400 mg/l) , Fe+2(5- 30 mg/l) و 500 mg/l)-TiO2 (100. تم دراسة التحلل لتاثير (Fe+2, H2O2) في النظام المتجانس و (TiO2, H2O2) في النظام الغير متجانس, بلغت نسبة ازالة الCOD 73.7% في نظام الاكسدة المتجانسة و 72.7% في نظام الاكسدة الغير متجانسة.


Article
Removal Color Study of Toluidine Blue dye from Aqueous Solution by using Photo-Fenton Oxidation
دراسة ازالة صبغه التلودين الازرق من محلولها المائي بواسطه استخدام تقنية الفنتون

Authors: Saadiyah A. Dhahir سعدية احمد ظاهر --- Enaas A. Hussein ايناس عبد الحسين --- Asaad H. Saleh اسعد حسون صالح --- Mouna Samer منى سمير هادي
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2016 Volume: 13 Issue: 2ملحق ابحاث المؤتمر الوطني الثاني للكيمياء Pages: 440-446
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The degradation of Toluidine Blue dye in aqueous solution under UV irradiation is investigated by using photo-Fenton oxidation (UV/H2O2/Fe+). The effect of initial dye concentration, initial ferrous ion concentration, pH, initial hydrogen peroxide dosage, and irradiation time are studied. It is found put that the removal rate increases as the initial concentration of H2O2 and ferrous ion increase to optimum value ,where in we get more than 99% removal efficiency of dye at pH = 4 when the [H2O2] = 500mg / L, [Fe + 2 = 150mg / L]. Complete degradation was achieved in the relatively short time of 75 minutes. Faster decolonization is achieved at low pH, with the optimal value at pH 4 .The concentrations of degradation dye are detected by spectrophotometer at λmax =626 nm. The order of photo degradation reaction under UV is the first order kinetics. The photo-Fenton degradation process was monitored by UV-visible spectrophotometer.

تم التحري عن صبغة تولدين الازرق باستعمال عمليات الأكسدة المتقدمة التي تتضمن تقنية الفنتون UV /H2O2 /Fe+2. تضمنت هذه الدراسة تأثير تركيز الصبغة الابتدائي , pH المحلول , كاشف فنتون ,جرعة بيرو كسيد الهيدروجين المستخدمة وزمن التشعيع على سرعة إزالة اللون . وجد إن سرعة الإزالة تزداد بزيادة تركيز بيرو كسيد الهيدروجين وايون الحديدوز للوصول إلى القيمة المثلى. أن التجزئة الضوئية باستعمال UV/H2O2/Fe+2 أسرع والنتائج أفضل حيث نحصل على كفاءة أكثر من 99% عند pH= 4 عندما يكون [H2O2 ]=500mg/L, ,[Fe+2= 150mg/L] . تم تحديد الطول الموجي لصبغة تولدين بلو باستعمال جهاز Spectrophotometer وكان الطول الموجي الأعظم يساوي 626nm. أوضحت نتائج التجارب الحركية إن تفاعل درجة التحطم الضوئي بتأثير الأشعة فوق البنفسجية هي من الدرجة الأولى بوجود الصبغة فقط .


Article
Removal of Oil from Wastewater by Advanced Oxidation Process / Homogeneous Process
ازالة الزيت من المياه الملوثة باستخدام عملية الاكسدة المتقدمة / الطريقة المتجانسة

Authors: Yasmin Abdulaziz Mustafa ياسمين عبد العزيز مصطفى --- Abeer Ibrahim Alwared عبير ابراهيم الورد --- Mothana Ebrahim مثنى ابراهيم
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2013 Volume: 19 Issue: 6 Pages: 686-694
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In the present work advanced oxidation process, photo-Fenton (UV/H2O2/Fe+2) system, for the treatment of wastewater contaminated with oil was investigated. The reaction was influenced by the input concentration of hydrogen peroxide H2O2, the initial amount of the iron catalyst Fe+2, pH, temperature and the concentration of oil in the wastewater. The removal efficiency for the system UV/ H2O2/Fe+2 at the optimal conditions and dosage (H2O2 = 400mg/L, Fe+2 = 40mg/L, pH=3, temperature =30oC) for 1000mg/L load was found to be 72%.

تم في هذا البحث دراسة معالجة المياه الملوثة بالزيت باستعمال احد طرق الاكسدة المتقدمة/المتجانسة بواسطة طريقة photo-Fenton (UV/H2O2/Fe+2) . تاثرت التفاعلات عند اضافة تراكيز مختلفة من بيروكسيد الهيدروجين (H2O2) ومن الحديد(Fe+2) كعامل مساعد والدرجة الحامضية (pH) والحرارة وتركيز الزيت في المياه الملوثة .اظهرت التجارب ان نسبة الازالة للزيت بلغت72% بواسطة الاكسدة المتقدمة / المتجانسةباستعمال طريقة photo - Fenton UV/H2O2/Fe+2 بالظروف المثالية (بيروكسيد االهيدروجين =400 ملغم /لتر ,اوكسيد الحديدوز= 40 ملغم /لتر ,الـدالة الحامضية pH=3 ودرجة الحرارة = 30 درجة مئوية وعند تركيز 1000ملغم /لتر للزيت في الماء) .

Listing 1 - 8 of 8
Sort by
Narrow your search

Resource type

article (8)


Language

English (7)

Arabic and English (1)


Year
From To Submit

2017 (1)

2016 (3)

2015 (2)

2013 (1)

2012 (1)