Argon plasma needle source
مصدر توليد ابرة بلازما الاركون

Loading...
Loading...
Abstract

Non thermal argon plasma needle at atmospheric pressure was generated. The experimental set up is based on very simple and low cost electric components that generate electrical field sufficiently high at the electrodes to ionize various gases, which flow at atmospheric pressure. The high d.c power supply is 7.5kV peak to peak, the frequency of the electrical field is 28kHz, and the plasma power less than 15W. The plasma is generated using only one electrode. In the present work the voltage and current discharge waveform are measured. Also the temperature of the working Ar gas at different gas flow and distances from the plasma electrode tip was recorded.

تم توليد ابرة بلازما الاركون غير الحرارية وتحت الضغط الجوي. باستعمال مكونات الكترونية بسيطة وواطئة الكلفة. لها القدرة على توليد مجال كهربائي عالي عند الاقطاب يكفي لتأين الغازات المختلفة والمتدفقة عند الضغط الجوي. ولدت البلازما التي تم دراستها بفولتية متناوبة عند الاقطاب 7.5 كيلوفولت من القمة الى القمة وكانت قدرتها 15 واط وتردد المجال المسلط 28 كيلو هرتز. قدم هذا العمل معلومات عن قياس القولتية والتيار اللذان استعملا في توليد البلازما. كذلك تم قياس درجة حرارة الاركون المتدفق بمستويات تدفق مختلفة من نهاية القطب الكهربائي.


Article
The Study of Electrical Description for Non-Thermal Plasma Needle System
دراسة التوصيف الكهربائي لمنظومة ابرة البلازما غير الحرارية

Authors: Ibrahim Karim Abbas ابراهيم كريم عباس --- Mohammed Ubaid Hussein محمد عبيد حسين --- Hamid H. Murbat حامد حافظ مربط
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2017 Volume: 58 Issue: 3B Pages: 1447-1453
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this research, a non-thermal plasma system was designed and a non-thermal plasma needle was manufactured for argon gas operating at normal atmospheric pressure. The electrical description of this system studied by using two different values of voltages (4.9,8) kV. Where the results showed the small amount of electrical current consumed by the system of plasma needle up to several microns of amps, and the value of the electrical current increase with the increasing gas flow, as well as the results, showed that happen a breakdown voltage at (8) kV when gas flow (4 l/min) causing a slight decrease in the electrical current value.

في هذا البحث، تم تصميم وتصنيع منظومة بلازما غير الحرارية لغاز الأرجون والتي تعمل عند الضغط الجوي الاعتيادي. حيث تم دراسة الوصف الكهربائي لهذه المنظومة المصنعة وذلك من خلال استخدام قيمتين مختلفتين من الفولتية (4.9,8) كيلو فولت. حيث اظهرت النتائج التي تم الحصول عليها صغر قيمة التيار الكهربائي المستهلك من قبل منظومة أبرة البلازما غير الحرارية حيث كان بحدود عدة مايكرونات من الامبير ، وكانت قيمة التيار الكهربائي تزداد زيادة طردية مع زيادة تدفق الغاز ، وكذلك اظهرت النتائج حدوث انهيار في الفولتية عندما تكون الفولتية المستخدمة (8) كيلو فولت والتي سببت انخفاض قليل في قيمة التيار الكهربائي عندما يكون تدفق الغاز (4 لتر/دقيقة).


Article
The study of thermal description for non-thermal plasma needle system
دراسة الوصف الحراري لمنظومة إبرة البلازما غير الحرارية

Loading...
Loading...
Abstract

Cold plasma is a relatively low temperature gas, so this feature enables us to use cold plasma to treat thermally sensitive materials including polymers and biologic tissues. In this research, the non-thermal plasma system is designed with diameter (3 mm, 10 mm) Argon at atmospheric pressure as well as to be suitable for use in medical and biotechnological applications.The thermal description of this system was studied and we observed the effect of the diameter of the plasma needle on the plasma, when the plasma needle slot is increased the plasma temperature decrease, as well as the effect of the voltages applied to the temperature of the plasma, where the temperature increasing with increasing the applied voltage . Results showed that the plasma temperature would be low, which enables the use of this system in many medical aspects.

البلازما الباردة هي غاز درجة حرارته منخفضة نسبيا، لذلك هذه الميزة تمكننا من استخدام البلازما الباردة لعلاج المواد الحساسة حراريا بما في ذلك البوليمرات والأنسجة البيولوجية. في هذا البحث تم تصميم منظومة بلازما الأرجون غير الحراري بقطر (3 و 10) مم عند الضغط الجوي، وكذلك لتكون مناسبة للاستخدام في التطبيقات الطبية والبيوتكنولوجية. تم دراسة الوصف الحراري لهذه المنظومة ولاحظنا تأثير قطر ابرة البلازما على درجة حرارة البلازما فانه كلما زاد نصف قطر الابرة فان درجة حرارة البلازما تقل, وكذلك تأثير الفولتية المطبقة على درجة حرارة البلازما حيث تزداد كلما زادت مقدار الفولتية, وأظهرت النتائج أن درجة حرارة البلازما ستكون منخفضة، والتي تمكن من استخدام هذا النظام في العديد من الجوانب الطبية.


Article
Influence of non-thermal argon plasma needle on blood coagulation
تأثير بلازما الأركون غير الحرارية على تخثر الدم

Authors: Kadhim A. Aadim كاظم عبد الواحد عادم --- Heba R. Najem هبه رياض نجم
Journal: Iraqi Journal of Physics المجلة العراقية للفيزياء ISSN: 20704003 Year: 2016 Volume: 14 Issue: 29 Pages: 101-106
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Non-thermal argon plasma needle at atmospheric pressure was constructed. The experimental setup was based on a simple and low cost electric component that generates a sufficiently high electric field at the electrodes to ionize the argon gas which flow at atmospheric pressure. A high AC power supply was used with 1.1 kV and 19.57 kHz. Non-thermal Argon plasma used on blood samples to show the ability of non-thermal plasma to promote blood coagulation. Three tests have been done to show the ability of plasma to coagulate both normal and anti-coagulant blood.Each blood sample has been treated for varying time from 20sec. to 180sec. at different distances. The results of the current study showed that the cold plasma produced from argon significantly increase the in vitro speed of blood coagulation, the plasma increases activation and aggregation of platelets, causes proliferation of fibroblasts and fibrin production accelerates blood coagulation.

تم تكوين أبره أركون بلازما غير الحرارية عند الضغط الجوي. واستندت الإعدادات التجريبية على مكونات كهربائية ذات تكلفة بسيطة ومنخفضة تعمل على توليد حقل كهربائي عالي عند الأقطاب لتأين غاز الاركون المستخدم الذي يتدفق عند الضغط الجوي. تم استخدام مجهز قدرة عالي ذو تيار متردد AC عند القيمة 1.1كيلوفولت وبالتردد19.57كيلوهيرتز.كما تم استخدام بلازما الاركون غير الحراريه في اظهار قدرتها على تخثر الدم.حيث اجريت ثلاث تجارب لاظهار قدرة البلازما على تخثير الدم الاعتيادي والدم المضاف له مانعات تخثر كل عينة دم تم معالجتها بزمن يتراوح مابين 20ثانية الى 180ثانية وعند مسافات مختلفة. النتائج اظهرت ان البلازما الباردة لها القدرة على تخثير الدم خارج الجسم خلال فترة قصيرة وكذلك تعمل على تفعيل تجمع الصفائح الدموية وتسريع انتشار الخلايا الليفية وبالتالي انتاج الفايبرين الذي يسرع تخثر الدم.


Article
The Effect of the Non-Thermal Plasma Needle on Pseudomonas Aeruginosa Bacteria
تأثير البلازما غير الحرارية على بكتيريا سيدوموناس ايروجينوسا

Loading...
Loading...
Abstract

The development in the field of medical physics has led to the use of devices that are manufactured under normal conditions to make tremendous progress in the world of development in medical treatment by using these devices with modern techniques by reducing the use of antibiotics and relying on these tools and devices that link between physics and modern therapeutic medicine. In this research, a non-thermal plasma system for argon gas operated at normal atmospheric pressure was designed, this system was applied on Pseudomonas Aeruginosa bacteria isolated from burn patients from Yarmouk Teaching Hospital. These bacteria were exposed to this system, the results showed that these bacteria were killed at time (5 min) and (8kV) where the argon gas flow rate was (5l/min).

أدى التطور في مجال الفيزياء الطبية الى استخدام الاجهزة التي يتم تصنيعها وتعمل تحت ظروف طبيعية الى احداث طفرة في العلاج الطبي وذلك بتقليل استخدام المضادات الحيوية والاعتماد على هذه الادوات والاجهزة التي تربط ما بين الفيزياء والطب العلاجي الحديث ، في هذه البحث تم تصميم منظومة بلازما غير حرارية لغاز الارجون تعمل عند الضغط الجوي الاعتيادي ، حيث تم تطبيق هذه المنظومة على بكتيريا Pseudomonas Aeruginosa) ) التي عزلت من المرضى المصابين بالحروق من مستشفى اليرموك التعليمي حيث تم تعريض هذه البكتريا لهذه المنظومة حيث تم الحصول على نسبة القتل التام لهذه البكتريا عند الزمن (5دقيقة) وعند فولتية (8 كيلو فولت) وتدفق غاز (5 لتر/دقيقة).


Article
Urinary Tract Infection Risk Assessment By Non- Thermal Plasma In Iraqis Patients

Author: Mohammed Ubaid Hussein (Ph.D ,Medical Physics )*, Rana Talb Mohsen(Master., Medicine Microbiology) **
Journal: Al-Kindy College Medical Journal مجلة كلية الطب الكندي ISSN: 18109543 Year: 2017 Volume: 13 Issue: 1 Pages: 86-91
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Background: In the present study used device jet plasma needle with atmospheric pressure which generates non thermal plasma jet to measure treatment potent with plasma against pathogenic bacteria founded in UTI was inactivated with plasma at 10 sec, Objective:. This work included the application of the plasma produced from the system in the field of bacterial sterilization , where sample of Gram- negative bacteria (Escherichia coli) were exposed to intervals (1-10)second . Midstream Urine samples swabs were obtained from patients with urinary tract infections.Type of the study: Cross -sectional study.Methods: The work were used in this study obtained from studying 100 urine samples, the age of patients ranged between 10 years to 60 years. They were 60 females and 40 males. These samples were cultured on culture media to isolate bacterial colonies .After that, bacteria were identified by means of highly specific investigations Escherichia coli, plasma needle treatment is applied on bacteria through sterilization, and adhesion.Results : It was found that the percentage of the killing of Gram-negative bacteria (E.coli) was 100% at (10) second, also decreasing bacterial adhesion on epithelial cells, where numbers adhesion bacterial with uroepithelial cells decrease after treatment with plasma needle .Conclusion : From this work, it has been observed that applied voltage ,distance between plasma needle and treatment model as well as time treatment effect on inactivation bacteria and sterilization ,also it effect on decreasing bacterial adhesion on epithelial cells, where numbers adhesion bacterial with uroepithelial cells decrease after treatment with plasma needle .


Article
The influence of argon gas flow in the killing of staphylococcus epidermidis bacteria
تأثير تدفق غاز الأرجون على نسبة قتل بكتيريا Staphylococcus epidermidis

Loading...
Loading...
Abstract

In this research, non-thermal plasma system of argon gas is designed to work at normal atmospheric pressure and suitable for work in medical and biotechnological applications. This technique is applied in the treatment of the Staphylococcus epidermidis bacteria and show the role of the flow rate of Argon gas on the killing rate of bacteria, and it obtained a 100 % killing rate during the time of 5 minutes at the flow Argon gas of 5 liters/ min.

في هذا البحث، تم تصميم منظومة البلازما غير الحرارية تعمل بغاز الأركون عند الضغط الجوي الاعتيادي ومناسبة للتطبيقات الطبية والبايوتكنولوجية. حيث تم تطبيق هذه التقنية في معالجة بكتيريا ستافلوكوكاس ابديرمدس وتبيين دور معدل تدفق غاز الأرجون على معدل قتل البكتيريا، وحصلنا على معدل قتل بنسبة 100٪ خلال زمن 5 دقائق عند تدفق 5 لتر/ الدقيقة.


Article
Electrical, thermal and optical characteristicsof plasma torch
تشخيص شعلة البلازما كهربائيا وحراريا وبصريا

Loading...
Loading...
Abstract

Non thermal argon plasma needle at atmospheric pressure was constructed. The experimental set up was based on simple and low cost electric components that generate electrical field sufficiently high at the electrodes to ionize various gases which flow at atmospheric pressure. A high AC power supply was used with 9.6kV peak to peak and 33kHz frequency. The plasma was generated using twoelectrodes. The voltage and current discharge waveform were measured. The temperature of Ar gas plasma jet at different gas flow rate and distances from the plasma electrode was also recorded.It was found that the temperature increased with increasing frequency to reach the maximum value at 15 kHz, and that the current leading the voltage, which demonstrates the capacitive character of the discharge.The electron temperature was measured at about 0.61 eV, and we calculated the electron number density to be 4.38×1015 cm-3.

تم توليد ابرة بلازما الاركون غير الحرارية وتحت الضغط الجوي. باستعمال مكونات الكترونية بسيطة وواطئة الكلفة. لها القدرة على توليد مجال كهربائي عالي عند الاقطاب يكفي لتاين الغازات المختلفة والمتدفقة عند الضغط الجوي. ولدت البلازما التي تم دراستها بفولتية متناوبة عند الاقطاب 9.6 كيلو فولت من القمة الى القمة, وتردد المجال المسلط 33 كيلو هرتز. قدم هذا العمل معلومات عن قياس الفولتية والتيار اللذان استعملا في توليد البلازما. كذلك تم قياس درجة حرارة الغاز (Ar) الاركون لابرة البلازما المتدفق بمستويات تدفق مختلفة من نهاية القطب الكهربائي. وجدت أن درجة الحرارة أرتفعت بأزدياد التردد للوصول إلى القيمة القصوى15 كيلو هيرتز ويبدا بالانخفاض مرة اخرى, ويمكن ان نرى ان سلوك التيار والفولتية يدل على شكل التفريغ ذو خواص سعوية. كما تم حساب درجة حرارة الالكترون وكانت بحدود 0.61 الكترون فولت, وحساب كثافة عدد الالكترونات وكانت بحدود 4.38×1015سم-3.