research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Effect Of Industrial Pollution On Different Types Of High Voltage Insulators
تأثير التلوث الصناعي على انواع مختلفة للعوازل العالية الفولتية

Authors: Sabah S. Salih صباح صديم صالح --- Yaroub G. Jasim يعرب جاسم --- Arkan A. Hussein اركان احمد
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2011 Volume: 15 Issue: 1 Pages: 108-117
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

High voltage insulators is essential part of the high voltage electric power transmission line . This paper investigate the electrical performance of two types of insulator (porcelain and silicon rubber) used in service and subjected to pollution condition from Baiji Refinery and thermal power station of Baiji for more than(10) years .The test data of flashover voltage measurements, surface resistance measurements and the insulators hydrophobicity are evaluated. The test result show that the silicon rubber insulator has a better performance compare with porcelain insulator.

عوازل الضغط العالي عنصر أساسي من مكونات خطوط الضغط العالي . هذا البحث تناول الخصائص الكهربائية لنوعين من العوازل ( البورسلين و مطاط السيلكون) مستخدمين في الخدمة ومعرضين إلى التلوث الصادر من مصفى بيجي و محطة بيجي الحرارية لأكثر من عشرة سنوات . النتائج المختبرية لقياس فولتية الشرر ، ومقاومة السطح ومقاومة العازل للماء تم حسابها . النتائج المختبرية أظهرت أن عوازل مطاط السيلكون لها الخصائص الأفضل مقارنة مع عوازل البورسلين .


Article
Studying Critical Flash Over of Different Types of High Voltage Insulator

Authors: Mokdad T.Younis --- Dr.Sami A.Ajeel
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2007 Volume: 25 Issue: 6 Pages: 815-827
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The critical flashover CFO of an insulation structure is commonly used todescribe the insulation structure lightening impulse strength. In this work,first CFO of polymer and porcelain each alone was measured and then, a newstructural arrangement is represented to measure (CFO). This arrangementsconsists of three layers; fiberglass is placed between two layers of polymer andporcelain .All insulation materials are examined in dry and wet condition withpositive and negative lightening impulse under (15,25 and 35) KV. The criticalflashover voltage (CFO) of insulator is distributed on certain surface alongwith fiberglass distribution poles as an insulator. Also altitude of poles istaken into consideration in calculating critical flashover voltage for bothinsulator and structure. (CFO) voltages are added from fiberglassdistribution pole to basic insulation component and are calculated based onthe test result of the (CFO). The above measurements indicated that the totalCFO voltage of new arrangements insulator under dry condition is muchhigher than under wet condition for the same impulse polarity and tested polelength.

يستخدم الجهد الحرج للومضة اللحظية بشكل مالوف لوصف قوة الضوء النبضي للبنية العازلة.في هذا البحث تم قياس , اولا الجهد الحرج للومضة اللحظية لمواد عازلة من البوليمروالبورسلين كلا على حدة بعد ذلك تم القياس لترتيب بنية جديدة حيث يتالف هذا الترتيب م نثلاث طبقات ، طبقة من الليف الزجاجي وضعت بين طبقتين من البوليمر مرة والبورسلين مرةاخرى. كل المواد اعلاه اختبرت تحت ظروف جافة ورطبة مع نبضات اضاءة موجبة وسالبةتحت ( ١٥،٢٥،٣٥ كيلو فولت ) . يكون الجهد الحرج للومضة اللحظية للعازل متوزع علىالسطح المحدد بامتداد الاعمدة الموزعة للالياف الزجاجية . اخذ بنظر الاعتبار ارتفاع الاعمدةفي حساب الجهد الحرج للومضة اللحظية لكلا من العازل والبنية . اضيفت الجهود الحرجةللومضة اللحظية من عمود الالياف الزجاجية الموزعة الى مكون العازل الاساسي وتكونمحسوبة بالاستناد الى نتيجة الاخت بارات للجهد الحرج للومضة اللحظية . القياسات اعلاه تشيرالى ان الجهود الحرجة للومضة اللحظية لترتيب العازل الجديد تحت ظروف جافة يكون اعلىبكثير مقارنة مع الظروف الرطبة لنفس النبض القطبي ونفس طول عمود الاختبار .

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic and English (1)

English (1)


Year
From To Submit

2011 (1)

2007 (1)