MANAGEMENT OF ELECTRICAL POWER CONSUMPTION USING NETWORK PROCESSOR
أدارةاستهلاكالطاقةالكهربائيةباستخداممعالجالشبكة

Loading...
Loading...
Abstract

AbstractProviding electrical power in developing countries is something hard to do for many reasons that could be financial, technical and even the lack of raw materials. Therefore, the need for new technique for fairly power distribution is more attractive. From this an idea comes to make new sophisticated distributed network system which controls power consumption for the given inhibited area. The system should give a certain amount of power for each consumer .When the consumer reaches his limit the system will take an action to increase the limit if power is available or disconnect the overloaded consumer for a specified time. the present work is devoted to design a system which has an ability of controlling the power consumption by using network processor.the designed overall system is fulfilled through four distinct stages; each stage has a predefined job. The four stages communicate with each other using TCP/IP protocols suit. Therefore, a TCP/IP stack should be available at each stage.Keywords:Management of Electrical Power Consumption, Monitoring of Power Consumption, Controlling of Power Consumption Using Network Processor.

الخلاصةإن تجهيز الطاقة الكهربائية في الدول النامية يواجهه صعوبات متعددة ، قد تكون اقتصادية أو تقنية أو نقص في المواد الأولية ، لهذا السبب ظهرت الحاجة إلى تقنية جديدة تضمن التوزيع العادل للطاقة . من هنا جاءت الفكرة إلى شبكة توزيع جديدة تضمن السيطرة على توزيع القدرة بصورة عادلة لجميع المشتركين . هذه الشبكة تعطي كمية محددة من الطاقة لكل مشترك ، وعندما يتجاوز المشترك الكمية المحددة له يجب على النظام إن يتخذ إجراء معين قد يكون إعطاء المشترك كمية اكبر من الطاقة إذا كان بالإمكان ذلك أو فصل الطاقة عن هذا المشترك فترة زمنية محددة.إن العمل الحالي مكرس لتصميم نظام له القابلية على السيطرة على استهلاك الطاقة الكهربائية باستخدام معالج الشبكة.تم تنفيذ العمل من خلال أربع محطات ، كل محطة لها وظيفة معينة ، وتتصل المحطات فيما بينها بواسطة بروتوكول TCP/IP .


Article
Power Saving Sleep Mode Enhancement Mobile WiMAX Networks

Authors: Ibtesam R. K. Al-Saedi --- Farah F. H. Alkhalid
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2016 Volume: 34 Issue: 6 Part (A) Engineering Pages: 1182-1193
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Recently, the use of mobile devices to run multimedia applications is becoming more popular. Such applications are known to be energy consuming. Since these devices are mostly battery powered with a limited battery life, energy saving strategies becomes vital for such systems operation. WiMAX systems utilize a standard sleep mode in order to reduce the mobile station (MS) power usage. It is also used to reduce the usage of base station (BS) air interface resources. IEEE 802.16e proposes three power saving classes (PSCs), depending on the type of the application(s) running on the device. However, when multiple applications that belong to different service types are operating simultaneously, the power consumption may increase due to overlapping among the used PSCs. In this work, a new mechanism is proposed to minimize power consumption of mobile WiMax devices. The proposed mechanism tries to eliminate the overlapping of PSCs by synchronizing the different PSCs. A simulation study is conducted and the simulation results indicate that the proposed mechanism can significantly reduce power consumption of MS; OPNET 14.5 modeler is the simulation tools that used in this work. However, this version of OPNET does not support sleep mode, but the sleep protocol is programed (in this work) using C Language inside the modeler, in order to show the effect of the proposed mechanism to enhance the power saving.


Article
Energy Saving in Power Consumption by Using Double Glazing Windows in Iraq

Authors: Walaa M. Hashim --- Hisham A. Hoshi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2018 Volume: 36 Issue: 9 Part (A) Engineering Pages: 1002-1007
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

It is generally accepted that the summer in Iraq is relatively hot season, where the temperature sometimes reaches 60 Cº. Accordingly, most of the Iraqi houses are characterized as having a large area of windows with a single glass, which could be resulted in a significant loss in cooling energy. Hence, the present research concern is to examine the effect of using double glass windows (as an alternative to single glass) on the saving in which energy normally used in houses and buildings at July and August for different hours 3, 6, 9, 12, 15, 18, 21 and 24 P.m. A practical and realistic study was conducted. Three values of aspect ratio are used 30, 15 and 10 for the presence of air between the panels and in the presence of the argon gas for aspect ratio, 10 were practically investigated. The experimental results confirmed that using of the double glass with the presence of air as a medium for heat transfer between the two panels could be reduced the amount of heat transferred compared to that of single glass between (45-78), (54-85)and(58-88)%, while for argon it was (60-91)%.


Article
A New Technology for Reducing Power Consumption in Synchronous Digital Design Using Tri-State Buffer

Author: Hussein Shakor Mogheer حسين شكور مغير
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2018 Volume: 11 Issue: 2 Pages: 60-66
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

This research paper deals with design and implementation of low power 8-bit arithmetic logic units. The main part of power consumption is consumed in ALU in any processor. Therefore, reducing power dissipation in ALU should be requiring. The proposed technique disabled one of the main block of ALU using tri-state logic which is not necessary to use, except the required processes. In this work, the suggested design is realized by using ASIC methodologies. In order to implement the arithmetic and logic architectures, 130 nm standard cell libraries are used for ASIC execution. The architecture of the design has been created using Verilog HDL language. In addition, it is simulated using ModelSim-Altera 10.3c (Quartus II 14.1) tools. By using tri-state technique, dynamic power and total power are decreased.


Article
Comparison between FPGA Co-Processor &Tms320 C641x DSP Family in Implementing DIF FFT Algorithm

Authors: A.M.Ragib --- N.H.Abbas
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2005 Volume: 11 Issue: 3 Pages: 533-540
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The Decimation in Frequency Fast Fourier Transform (DIF FFT) is a computationally intensive digital signal processing function widely used in application such as imaging and wireless communication .Historically, this has been a relatively difficult function to implement optimally in hardware, leading many software designers to use digital signal processors (DSPs) in soft implementations. Unfortunately, because of the function s computationally intensive nature, such an approach typically requires multiple DSPs within the system to support the processing requirements. This is costly from a device and board rcal – estate perspective as well as power intensive.Field –programmable gate array (FPGA) co-processors have become an extremely cost – effective means of off – loading computationally intensive algorithms to improve overall system performance while reducing development time, cost and risks. This paper will describe two DIF FFT implementation approaches, one implemented as an FPGA co –processor and the other using only an external TMS320C641X DSP Family. It will then examine the advantages and disadvantages of implementation perspectives.

محول فورير السريع مقسم التردد (DIF FFT) كثيرا" مايستخدم في تطبيقات معالج الاشارة الرقمية مثل التصوير والاتصالات اللاسلكية .تاريخيا تكون هكذا وظائف صعبة البناء بصورة مثلى ككيان مادي ،لذلك تقدم عدد من مصممي البرامج من اجل استخدام معالج الاشارة الرقمية في بناء بسيط. ولكن لسوء الخط ، بسبب كون الوظائف المراد بنائها حسابيا مركزة لذلك نحتاج الى عدة معالجات داخل نفس النظام من اجل تحقيق متطلبات المعالجة .وهذا الشى مكلف اضافة الى كونه يصرف قدرة اكثر .المعالج المساعد الذي يستخدم ترتيب بوابة برمجة المجال (FDGA Co-processor) يستخدم من اجل تحسين اداء النظام بصورة شاملة ويقلل من زمن المعالجة والكلفة والمحاطر .هذه المنشورة تصف طريقتين لبناء محول فورير السريع مقسم التردد( DIF FFT) الاولى باستخدام ترتيب بوابة برمجة المجال (FPGA) والثانية باستخدام معالج الاشارة الرقمية (TMS 320C641X DSP Family) وبعدها نختبر فوائد ومساوئ كلا الطريقتين من ناحية الأداء ، والكلفة ، صرف الطاقة وسهولة البناء.


Article
Optimum Charge and Performance for R432A under Window Type Air-Conditioner Systems
الشحنة المثالية و اداء غاز R432A تحت منظومة مكيف هواء شباكي

Author: Haider ali hussen
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 6 Part (A) Engineering Pages: 1369-1379
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The study presents optimized R432A charge by the index of power consumption of compressor and COP without changing the compressor. Test results showed that the best charge is 750 g for R432A which gave the highest coefficient of performance and less energy consumption. When charging the system with 750 grams, the amount of charge rate down to 42.3% compared with the original gas. The percentage increase in coefficient of performance are 9.85%, 8.39%, and 8.93% and the proportion of low energy consuming are 7.53%, 7.31%, and 7.34% at ambient temperatures of 30 ᵒC,34 ᵒC and 38 ᵒC respectively for R432A compared to R22. Increasing ambient temperature lead to increase in the power consumed and decrease coefficient of performance.

هذه الدراسةِ قدمت الشحنة المثالية التي حَسّنتْ بالإستهلاكِ الكهربائيِ في الضاغطِ ومعامل الاداء لغاز R432A بدون تَغيير الضاغطِ،. أظهرت نَتائِجَ الإختبارِ بأنّ أفضل شحنة هي 750 g لغاز R432A الذي اعطى المعاملِ الأعلى للأداءِ وأقل إستهلاكِ لطاقة. عندما يَشْحنُ النظامَ في 750 غرامِ، فان كمية الشحنة تقل بنسبة 42.3 % بالمقارنة بالغازِ الأصليِ. الزيادة في معاملَ الأداءِ هي 9.85 % ,8.39% و8.93 % ونسبة إسْتِهْلاك طاقةِ اقل 7.53 %,7.31%و7.34% عند درجات حرارة بيئيةِ 30 ,34 و38 درجة مئوية على التوالي لغاز R432A بالمقارنة مَع R22. تُؤدّي درجةُ الحرارة البيئية المتزايدة إلى الزيادةِ في الطاقة المستهلكة وتَنْقصُ معاملَ الأداءِ المنظومة.


Article
Optimization of Power Consumption in Cloud Data Centers Using Green Networking Techniques
الإستهلاك الأمثل للقدرة في مراكز البيانات السحابيه بإستخدام تقنيات الشبكات الخضراء

Authors: Dr. Qutaiba I. Ali د. قتيبة ابراهيم علي --- Alnawar J. Mohammed النوار جاسم محمد
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2014 Volume: 22 Issue: 2 Pages: 13-27
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

Optimization of Power Consumption in Cloud Data CentersUsing Green Networking TechniquesDr. Qutaiba I. Ali Alnawar J. MohammedEmail: qut1974@gmail.com Email: alnawar_j25758@yahoo.comComputer Engineering Dept., College of Engineering, University of Mosul, Mosul, Iraq.AbstractIn this paper, a neuro-based predictor is proposed with a prediction algorithm toestimate the required number of active servers simulating the Green Networkingobjectives. The inputs of such predictor are the CPU utilization of the servers in the datacenter and the variations of the incoming demands with the number of users’ variation.During the work, different demand profiles of ClarkNet traffic traces are simulated onOPNET14.5 Modeler to obtain the required training values of servers’ CPU utilizationand clients’ throughput. Also, Green Networking objectives are defined to maintain thePower Management Criteria (PMC) which guaranteed that all CPU utilization must begreater than 30%. Taking into account that a maximum number of 100 servers are usedin such local data center, an ON/OFF control algorithm is then suggested for the powermanagement of different servers in data center to fulfill the previous Green objectives.The Power saving is finally evaluated since it has been noticed that the power savingpercentage can be increased from 17.33% to 85.33% of a total power of 75 k watts whenthe number of the operating servers is decreased from 80% to 5% of the overall servers.Keywords: Artificial Neural Network (ANN), Cloud Computing, Data Centers,Green Networking, Power Consumption.الإستهلاك الأمثل للقدرة في مراكز البيانات السحابيه بإستخدامتقنيات الشبكات الخضراءد. قتيبة ابراهيم علي النوار جاسم محمدEmail: alnawar_j25758@yahoo.com Email: qut1974@gmail.comقسم هندسة الحاسوب، كلية الهندسة، جامعة الموصل،الموصل، العراق.الخلاصةفي هذا البحث، تم اقتراح متنبيء قائم على استخدام الشبكة العصبية مع خوارزمية لتقدير العدد المطلوب منالخوادم النشطة محاكية أهداف الشبكات الصديقة للبيئة )الخضراء(. مدخلات هذا المتنبيء هي نسبة استغلال وحدةالمعالجة المركزية للخوادم في مركز البيانات، بالاضافة الى التغير في مقادير الطلبات الواردة من عدد من المستخدمين.و تم بناء نماذج مختلفة لشبكة مراكز ،ClarkNet أثناء العمل، تم تسليط نماذج مختلفة من الطلبات الواردة الى خوادمللحصول على القيم المطلوبة للتدريب وهي نسبة OPNET Modeler البيانات باستخدام برنامج المحاكاة 14.5الاستغلال لوحدة المعالجة المركزية للخودام ونسبة الحمل المسلط من قبل العملاء. أيضا تم تعريف أهداف الشبكاتالخضراء بالحفاظ على معايير ادارة الطاقة المتمثلة بأن تكون قيم نسبة استغلال وحدة المعالجة المركزية للخوادم أكبرمن 03 ٪. بعد الأخذ بعين الاعتبار أن الحد الأقصى لعدد الخوادم في مركز البيانات المقترح في العمل هو 100 خادم ،لإدارة استخدام الطاقة من قبل خوادم مختلفة في مركز البيانات لتحقيق أهداف الشبكة ON/OFF اقترحت خوارزميةالخضراء السابقة الذكر. أخ ي ر ا تم تقييم معدل تقليل صرف الطاقة حيث من الملاحظ أن نسبة تقليل صرف الطاقة ازدادتمن % 17.33 الى % 85.33 من مقدار صرف الطاقة الكلي المقدر بحوالي 57 كيلوواط عندما يقل عدد الخوادم التيتكون في حالة عمل من % 80 الى % 5 من عدد الخوادم الكلي.

Optimization of Power Consumption in Cloud Data CentersUsing Green Networking TechniquesDr. Qutaiba I. Ali Alnawar J. MohammedEmail: qut1974@gmail.com Email: alnawar_j25758@yahoo.comComputer Engineering Dept., College of Engineering, University of Mosul, Mosul, Iraq.AbstractIn this paper, a neuro-based predictor is proposed with a prediction algorithm toestimate the required number of active servers simulating the Green Networkingobjectives. The inputs of such predictor are the CPU utilization of the servers in the datacenter and the variations of the incoming demands with the number of users’ variation.During the work, different demand profiles of ClarkNet traffic traces are simulated onOPNET14.5 Modeler to obtain the required training values of servers’ CPU utilizationand clients’ throughput. Also, Green Networking objectives are defined to maintain thePower Management Criteria (PMC) which guaranteed that all CPU utilization must begreater than 30%. Taking into account that a maximum number of 100 servers are usedin such local data center, an ON/OFF control algorithm is then suggested for the powermanagement of different servers in data center to fulfill the previous Green objectives.The Power saving is finally evaluated since it has been noticed that the power savingpercentage can be increased from 17.33% to 85.33% of a total power of 75 k watts whenthe number of the operating servers is decreased from 80% to 5% of the overall servers.Keywords: Artificial Neural Network (ANN), Cloud Computing, Data Centers,Green Networking, Power Consumption.الإستهلاك الأمثل للقدرة في مراكز البيانات السحابيه بإستخدامتقنيات الشبكات الخضراءد. قتيبة ابراهيم علي النوار جاسم محمدEmail: alnawar_j25758@yahoo.com Email: qut1974@gmail.comقسم هندسة الحاسوب، كلية الهندسة، جامعة الموصل،الموصل، العراق.الخلاصةفي هذا البحث، تم اقتراح متنبيء قائم على استخدام الشبكة العصبية مع خوارزمية لتقدير العدد المطلوب منالخوادم النشطة محاكية أهداف الشبكات الصديقة للبيئة )الخضراء(. مدخلات هذا المتنبيء هي نسبة استغلال وحدةالمعالجة المركزية للخوادم في مركز البيانات، بالاضافة الى التغير في مقادير الطلبات الواردة من عدد من المستخدمين.و تم بناء نماذج مختلفة لشبكة مراكز ،ClarkNet أثناء العمل، تم تسليط نماذج مختلفة من الطلبات الواردة الى خوادمللحصول على القيم المطلوبة للتدريب وهي نسبة OPNET Modeler البيانات باستخدام برنامج المحاكاة 14.5الاستغلال لوحدة المعالجة المركزية للخودام ونسبة الحمل المسلط من قبل العملاء. أيضا تم تعريف أهداف الشبكاتالخضراء بالحفاظ على معايير ادارة الطاقة المتمثلة بأن تكون قيم نسبة استغلال وحدة المعالجة المركزية للخوادم أكبرمن 03 ٪. بعد الأخذ بعين الاعتبار أن الحد الأقصى لعدد الخوادم في مركز البيانات المقترح في العمل هو 100 خادم ،لإدارة استخدام الطاقة من قبل خوادم مختلفة في مركز البيانات لتحقيق أهداف الشبكة ON/OFF اقترحت خوارزميةالخضراء السابقة الذكر. أخ ي ر ا تم تقييم معدل تقليل صرف الطاقة حيث من الملاحظ أن نسبة تقليل صرف الطاقة ازدادتمن % 17.33 الى % 85.33 من مقدار صرف الطاقة الكلي المقدر بحوالي 57 كيلوواط عندما يقل عدد الخوادم التيتكون في حالة عمل من % 80 الى % 5 من عدد الخوادم الكلي.


Article
THE INFLUENCE OF AIR DISTRIBUTORS ON HEAT TRANSFER COEFFICIENT IN FLUIDIZED BED OF HEAT PIPE HEAT EXCHANGER

Author: Amer M. Al-Dabagh
Journal: AL-TAQANI مجلة التقني ISSN: 1818653X Year: 2006 Volume: 19 Issue: 2 Pages: 135-149
Publisher: Foundation of technical education هيئة التعليم التقني

Loading...
Loading...
Abstract

Heat exchanger made of heat pipes elements immersed in a fluidized bed represents one of the most economic devices used in recovery of waste heat energy. In the present work ten copper heat pipes (each 22.2mm diameter and 550 mm length), fixed in staggered arrangement with (175mm) static bed height, and (176,353,707μm sand mean particle diameter) were used . Two types of air distributors (bubble cap and perforated plate) were used with an open area of (21.6%, 6.36%, 3.97%). The study covers the air mass velocity from (0.31 to 0.57 Kg/m2 Sec), with hot bed temperature of 160Co. The results show that the overall heat transfer coefficient for the heat exchanger using bubble cap distributor is slightly higher than that for perforated plate, while the power consumption was greater by 30% for bubble cap distributor. Bubble cap distributors pressure drop was 90% greater than perforated plate distributor for the same operating conditions. At the same time , it shown that heat transfer coefficient is increased with open area increase, while opposite response was found for power consumption .

تمثل المبادلات الحرارية ذات الانابيب الحرارية المغمورة في وسط مميع أحدى الوسائل الفعالة لأسترداد الطاقة الضائعة. تناول البحث دراسة انتقال الحرارة في مبادل حراري مصنوع من عشرة أنابيب حرارية نحاسية بطول 550ملم وبقطر 22.2 ملم مغمورا في طبقة مميعة بالغاز ومرتبة بشكل متخالف . مستخدمين ثلاثة اقطار لحبيبات الرمل(176،353،707مايكروميتر) بمعدل أرتفاع للطبقة المميعة 175 ملم. تم حساب معامل انتقال الحرارة مع تغير النسبة المئوية للمساحة المفتوحة للهواء (21.6%،6.36%،3.97%) لنوعين من الموزعات الهواء (مثقب وفقاعي ) .أجريت التجارب عند درجة حرارة 160 مه للطبقة الساخنة ومعدل تدفق هواء ( 0.57 - 0.31 كغم/م2 ثا) . أظهرت النتائج أن معامل انتقال الحرارة للمبادل الذي يستخدم موزع الهواء الفقاعي كانت أكثر من موزع الهواء المثقب، فيما كان معدل استهلاك القدرة أكثر وبنسبة 30% لموزع الهواء الفقاعي . كما أن هبوط الضغط عبر الموزع الفقاعي يصل إلى 90% أكثر من موزع الهواء المثقب تحت نفسها الظروف التشغيلية . واخيراً يمكن القول أن معامل انتقال الحرارة يزداد بزيادة النسبة المئوية للمساحة المفتوحة لموزع الهواء ,بينما يقل معدل استهلاك القدرة .


Article
Bubble Size Distribution In Gas-Liquid Dispersion Column

Authors: Thamer J. Mohammed --- Fadi Z. Hanna --- Ihsan B. Hamawand
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2012 Volume: 18 Issue: 7 Pages: 799-818
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present work investigates the effect of; superficial air velocities of: 1, 3, and 6 cm/s for two types of perforated distributor on hydrodynamic characteristic in a gas-liquid dispersion column of; air-water, and air-aqueous-n-propanol solution. Bubble distribution, gas holdup, and power consumption are parameters take in consideration. Experimental work was carried out in perspex column of 8.5 cm inside diameter and 1.5 m height. Two types of bubble generator (perforated plate) were fixed at the bottom of the column; plate A (99 holes of 0.5 mm diameter and free area of 0.34%), plate B (20 holes of 1.5 mm diameter and free area of 0.62%). Photographic technique was used to measure the bubble parameters.The experimental results were represented by two empirical correlations. The gas holdup and the Sauter mean diameter of bubbles were correlated with both the power consumption and the hole diameter of the perforate plate.

العمل الحالي دراسة تأثير ، سرعة الهواء الظاهريه (1، 3، و 6 سم / ثا) ونوعين من الموزع الهواء على الخصائص الهيدروديناميكية في عمود تشتت الغاز السائل من نظامين؛ الهواء والماء، والهواء ومحلول بروبانول اعتيادي. معدل توزيع الفقاعات، وكميه الغاز المحتجز، واستهلاك الطاقة اخذت بنظر الاعتبار في هذه الدراسه. وقد أجريت تجارب العمل في العمود بقطر داخلي 8،5 سم وارتفاع 1،5 متر. وقد تم تثبيت نوعين من موزعات الهواء (لوحة مثقبة) في الجزء السفلي من العمود؛ لوحه (ا) (99 ثقب بقطر0،5 مم وكانت مساحه التثقيب تساوي 0،34 ٪)، لوحه (ب) (20 ثقب بقطر 1،5 مم وكانت مساحه التثقيب تساوي 0،62٪). تم استخدام تقنية التصوير الفوتوغرافي لقياس القيم المحدده للفقاعة. كما تم ربط النتائج العملية بمعادلات تحليلية حيث تم ربط كمية الهواء المحتجز ومعدل قطر الفقاعات بالطاقة المستهلكة وقطر موزع الهواء.


Article
Minimizing Power Consumption in Combinational Logic Circuits by Reducing Switching Activity
تقلیل القدرة المستھلكة في الدوائر المنطقیة بتقلیل فعالیة التشغیل

Author: Nahla D. Habeeb
Journal: Thi-Qar University Journal for Engineering Sciences مجلة جامعة ذي قار للعلوم الهندسية ISSN: 20759746 Year: 2011 Volume: 2 Issue: 1 Pages: 118-125
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

The aim of the present paper is to investigate the minimization of the power consumption in combinational circuits by reducing the switching activity. A synthesis approach based on an iterative procedure that compares the minterms consequently, eliminate the complementary variables, then ORing all the terms in one simplified equation isintroduced . The results show that about 10% reduction in switching activity has been obtained by using this method if it is compared with the normal optimal solution obtained from K-map method.

یھدف البحث الحالي الى دراسة تقلیل القدرة المستھلكة في الدوائر المنطقیة بتقلیل فعالیة التشغیل . یستند الاسلوب المتبع في البحث على عملیة متتابعة یتم فیھا مقارنة المدخلات المتشابھھ (ذات الخرج ١) واختزال العناصر المتتامة ثم جمع الحدود المبسطة في معادلة واحدة. تشیر النتائج الى ان فعالیة التشغیل قد تم تقلیلھا بحدود ١٠ % عند استخدام ھذه الطریقة بالمقارنة مع تلك الدوائر المصممة باستخدام الطریقة التقلیدیة في مخطط كارنوف .