research centers


Search results: Found 33

Listing 1 - 10 of 33 << page
of 4
>>
Sort by

Article
Exergy Losses Calculation for a 125 MW Combined Power Plant
حسابات خسائر الاكسیرجي لمحطة مشتركة

Author: Falah F. Hatem
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2009 Volume: 27 Issue: 2 Pages: 386-394
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Theoretical exergy analysis is carried out for different components of acombined power plant which consists of a gas turbine unit, waste heat recoveryboiler without extra fuel consumption and steam turbine unit. The resultspinpoint that more exergy losses occurred in the gas turbine combustionchamber. Its reached 33% of the consumed fuel exergy while the exergy lossesin other plant components are between 1% - 5% of the consumed fuel exergy.This paper also considered the effect of the pressure ratio, maximumtemperature, boiler pressure and ambient temperature on the exergy losses in theplant, there are a clear effects in the exergy losses when changing pressure ratio,maximum temperature and boiler pressure.

یتضمن البحث حساب خسائر الاكسیرجي في مختلف مكونات محطة التولید المشتركة التي تتك ونمن وحدة التوربین الغازي ومرجل استعادة الح رارة ب دون ح رق وق ود أض افي ووح دة الت وربین البخ اري.نتائج البحث أظھرت أن معظم خسائر الاك سیرجي تتركز في غرفة الاحتراق حیث وصلت إلى 33 %م ن%5-% اكسیرجي الوقود المستھلك أما بقیة مكونات المحطة ف ان خ سائر الاك سیرجي فیھ ا تت راوح ب ین 1من اكسیرجي الوقود المستھلك . تضمن البحث أی ضا بی ان ت أثیر ن سبة ال ضغط ودرج ة الح رارة الق صوىوضغط المرجل ودرجة حرارة المحیط عل ى خ سائر الاك سیرجي ف ي مختل ف مكون ات المحط ة .لق د ك انھناك تأثیرا"واضحا" على خسائر الاكسیرجي عندما تتغیر ھذه البرامترات


Article
Study of the Condenser Performance in Al-Nassiriyah Thermal Power Plant

Authors: Khalid N. Hassan --- Qais A. Rishack --- Ahmed K. Mohammed
Journal: Thi-Qar University Journal for Engineering Sciences مجلة جامعة ذي قار للعلوم الهندسية ISSN: 20759746 Year: 2011 Volume: 2 Issue: 3 Pages: 95-112
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

This paper includes a study of the performance of Al-Nassiriyah thermal power plant condenser. Which includes a calculations of the main variables of condenser (heat transfer, condensation rate, overall heat transfer coefficient and vapour pressure) by applying two dimensional mathematical model and depending on the empirical equations of heat transfer.Comparison was made between the theoretical results for Al-Nassiriyah thermal power plant condenser before operation it (standard power plant) with practical data which taken from the plant for the second unit in year 2007. The comparison showed that there was a largedifference between theoretical results and the values taken from the plant as a result to the effect of operation conditions.


Article
Entropy Method as Criteria for Analysis of a Steam Power Plant

Author: Moayed Razoki Hasan
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2007 Volume: 13 Issue: 3 Pages: 1818-1833
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this paper a theoretical analysis of South Baghdad and Dura power plant is carried out according to second law of thermodynamic depending on entropy (irreversibility coefficient or lost work) method instead of exergy (availability) method. In the used entropy method. The power plant is divided into main blocks ( boiler, turbine, condenser, and feed water heater and pumps ). The irreversibility losses and coefficient for each block are calculated and then the overall irreversibility and thermal efficiency of the plant are calculated. The results of this work are compared with previous results, that depending on exergy method. The comparison of results show that both methods give approximately the same results since both of them rely the 2nd law of thermodynamic. Entropy method is simple and intellectually and intuitively satisfying and giving direct relationship between components losses of power plant and its overall efficiency.

يتناول البحث الحالي تحليل محطة جنوب بغداد ومحطة الدورة الحرارية باعتماد طريقة الانتروبي (معامل اللانعكاسية او الشغل المفقود) بدلا من طريقة المتاحية. في طريقة الانتروبي المستخدمة, يتم تقسيم محطة القدرة الى اجزاء رئيسية ( المرجل, التوربين, المكثف, و المسخنات و مضخات ماء التغذية ). يتم حساب معاملات و خسائر اللاانعكاسية لكل جزء ثم بعد ذلك يتم حساب اللاانعكاسية الكلية للمحطة و كفاءتها الحرارية. اظهرت مقارنة النتائج مع نتائج الاعمال السابقة لتحليل المحطتين باعتماد طريقة المتاحية. لقد اشارت النتائج بان الطريقتين تعطيان نتائج متقاربة جداً مع افضلية لطريقة الانتروبي التي تمتاز بسهولتها مع امكانية الربط المباشرلخسارات كل جزء من اجزاء المحطة مع الكفاءة الكلية للمحطة.


Article
Entropy Method as Criteria for Analysis a Steam Power Plant

Author: Moayed Razoki Hasan
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2009 Volume: 15 Issue: 3 Pages: 4025-4040
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this paper a theoretical analysis of South Baghdad and Dura power plant is carried out according to second law of thermodynamic depending on entropy (irreversibility coefficient or lost work) method instead of exergy (availability) method. In the used entropy method. The power plant is divided into main blocks ( boiler, turbine, condenser, and feed water heater and pumps ). The irreversibility losses and coefficient for each block are calculated and then the overall irreversibility and thermal efficiency of the plant are calculated. The results of this work are compared with previous results, that depending on exergy method. The comparison of results show that both methods give approximately the same results since both of them rely the 2nd law of thermodynamic. Entropy method is simple and intellectually and intuitively satisfying and giving direct relationship between components losses of power plant and its overall efficiency.

يتناول البحث الحالي تحليل محطة جنوب بغداد ومحطة الدورة الحرارية باعتماد طريقة الانتروبي (معامل اللانعكاسية او الشغل المفقود) بدلا من طريقة المتاحية. في طريقة الانتروبي المستخدمة, يتم تقسيم محطة القدرة الى اجزاء رئيسية (المرجل, التوربين, المكثف, و المسخنات و مضخات ماء التغذية). يتم حساب معاملات و خسائر اللاانعكاسية لكل جزء ثم بعد ذلك يتم حساب اللاانعكاسية الكلية للمحطة و كفاءتها الحرارية. اظهرت مقارنة النتائج مع نتائج الاعمال السابقة لتحليل المحطتين باعتماد طريقة المتاحية. لقد اشارت النتائج بان الطريقتين تعطيان نتائج متقاربة جداً مع افضلية لطريقة الانتروبي التي تمتاز بسهولتها مع امكانية الربط المباشر لخسارات كل جزء من اجزاء المحطة مع الكفاءة الكلية للمحطة.


Article
MATHEMATICAL MODEL FOR THE STUDY EFFECTS OF METEOROLOGICAL CONDITIONS ON DISPERSION OF POLLUTANTS IN AIR
موديل رياضي لدراسة تاثير الظروف الجوية على انتشار الملوثات في الهواء

Author: Anaam A. Sabri أنعام اكرم صبري
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2011 Volume: 4 Issue: 2 Pages: 150-165
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

The purpose of the present work was to investigate air quality that contained pollutant gases (SO2 , NO2 , CO) released from the thermal power plant as case study. Gaussian Plume Model and the computer program (visual basic 6) is used to calculate concentrations dispersion of gas pollutants at different meteorological conditions (wind speed, ambient temperature); maximum concentration values, downwind distance and required effective stack height estimation. A typical theoretical investigation of a case study concerning existing air pollution problems at an industrial area (4Km) downwind distance by using the computer program. The results showed that the concentration of SO2 (890 µg/m3) released from stack may is higher than the EPA standard. Also the optimum point of the ground level concentration of pollutants decreases with increasing effective stack height.

يهدف البحث الى تعيين نوعية الهواء المحتوي على الغازات الملوثة (SO2, NO2, CO ) المنبعثة من وحدة الطاقة الكهربائية الحرارية. وتم استخدام موديل كاوسين لحساب تراكيز الملوثات الغازية واستخدم برنامج الحاسبة (Visual basic 6) المنتشرة في ظروف جوية مختلفة (سرعة الريح, درجة حرارة المحيط) وقيم التراكيز القصوى والمسافة باتجاة الريح وتعيين ارتفاع المدخنة المؤثر.وتم تحليل نظري لدراسة حالة تمثل مشاكل تلوث الهواء على منطقة صناعية لمسافة 4كم باتجاة الريح باستخدام برنامج الحاسبة. وقد اظهرت النتائج بان تركيز غاز SO2 (890 مايكروغرام/مترمكعب) المنبعث من المدخنة اعلى من من القيم القياسية ل EPA وكذلك القيم المثلى لتركيز الملوثات عند مستوى سطح الارض يقل بزيادة ارتفاع المدخنة المؤثر.


Article
A ROBUST PRACTICAL GENERALIZED PREDICTIVE CONTROL FOR BOILER SUPER HEATER TEMPERATURE CONTROL

Author: Zaki Maki Mohialdeen
Journal: Iraqi Journal for Electrical And Electronic Engineering المجلة العراقية للهندسة الكهربائية والالكترونية ISSN: 18145892 Year: 2010 Volume: 6 Issue: 1 Pages: 33-38
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

A practical method of robustgeneralized predictive controller (GPC)application is developed using acombination of Ziegler-Nichols typefunctions relating the GPC controllerparameters to a first order with time delayprocess parameters and a model matchingcontroller.The GPC controller and the modelmatching controller are used in amaster/slave configuration, with the GPCas the master controller and the modelmatching controller as the slave controller.The model matching controller parametersare selected to obtain the desired overallperformance.The effectiveness of the proposed controlmethod is tested by simulation using amathematical model of the boiler superheater temperature process


Article
Characterization of SiC/SiC Composites Used for Power Plant Blanket

Authors: K.M.Y. Hasan --- N.I.M. Elkashif --- S.A.M. Ebrahim
Journal: Iraqi Journal of Applied Physics Letters الرسائل العراقية في الفيزياء التطبيقية ISSN: 1999656X Year: 2009 Volume: 2 Issue: 1 Pages: 27-30
Publisher: iraqi society for alternative and renewable energy sources and techniques الجمعية العراقية لمصادر وتقنيات الطاقة البديلة والمستجدة

Loading...
Loading...
Abstract

This paper describes the results of an exploratory study of blanket concepts based on SiC/SiC structure and LiPb breeder. An assessment of the performance of these concepts for advanced power plant application is presented, key issues are identified, and constraints relating to the SiC/SiC properties are discussed.


Article
Investigating the influence of emitted Cadmium from crude oil combustion on glutathione level in workers at Al- Qudis power plant, Baghdad
التحري عن تأثير الكادميوم المنبعث من احتراق الوقود الخام في مستوى الكلوتاثيون للعاملين في محطة كهرباء القدس, بغداد

Authors: Fawzi S. Al-Zubaidi , فوزي شناوة الزبيدي1 --- Nahi Y. Yaseen ناهي يوسف ياسين --- Mahmood B. Mahmood محمود باسل محمود
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2014 Volume: 55 Issue: 4B Pages: 1792-1801
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Al-Qudis power plant was chosen, as one of the power stations of Baghdad, to investigate the effects of Cadmium that emitted from combustion of crude oil in that power plant on the workers' glutathione serum level. Air samples were taken seasonally during August 2011- July 2012 from four sites at Al- Qudis power plant which are oil treatment unit 1(site 1), oil treatment 2 (site2), pre –chimney 1(site 3) and pre-chimney 2 (site 4), to measure levels of heavy metal (cadmium) under study. Blood samples were collected from the workers to estimate the heavy metal Cadmium. Air cadmium levels during summer (August and September) were varied from 6.26 ± 0.6 µg/m3 at site 1 to 6.89 ± 0.67 µg/m3 at site 3, while in spring (end of March, and end of April); these figures were ranged from 4.95 ± 0.39 µg/m3 at site 4 to 6.08 ± 0.5 µg/m3 at site 2. However, autumn (end of October and November) had mean values lied between 4.89 ± 0.6 µg/m3 at site 3 and 5.7 ± 0.57 µg/m3 at site 2. Winter (end of December 2011,January and February 2012)data gave a range of 4.51 ± 0.46 µg/m3 at site 4 and 4.98 ± 0.57 µg/m3 at site 3. The current results exceeded the acceptable levels of Cd for WHO which is around 0.3 µg/m3. The results of current study showedthatthe mean value ofcadmiumin the blood of occupational sampleswas6.418 ± 0.636 µg/l which was significantly higher than those of (P≤ 0.05) environmental (5.247 ± 0.418 µg/l) and (P≤ 0.01) control (1.854±0.41 µg/l) samples.For reduced Glutathione (GSH) concentration, the current study results showed the highest value 5.4 ± 0.52 µmol/l in respect to control sample, while the lowest data 2.2595 ± 0.412 µmol/l and 2.6625 ± 0.475 µmol/l have been found in environmental and occupational samples, respectively.These results indicate that heavy metal (cadmium) influence GSH level of Al-Qudis's workers.

تم أختيار محطة كهرباء القدس أحدى محطات توليد الكهرباء في بغداد للتحري عن تاثير الكادميوم المنبعث من احتراق الوقود الخام في مستوى الكلوتاثيون المصلي للعاملين في المحطة. اخذت عينات الهواء موسميا من أب 2011 حتى تموز 2012 من اربعة مواقع في محطة كهرباء القدس وهي وحدة معالجة الوقود رقم 1 ووحدة معالجة الوقود 2 وموقع المداخن رقم 1 وموقع المداخن رقم 2 وذلك لقياس مستوى الكادميوم في الهواء, وكذلك اخذت عينات دم العاملين في المحطة لتقدير تركيز الكادميوم في الدم. اظهرت النتائج ان معدل تركيز الكادميوم في الهواء خلال الصيف (شهري آب و أيلول) كان يتغير بين 6.26 ± 0.6 مايكروغرام/م3 في موقع رقم واحد و 6.89 ± 0.67مايكروغرام/م3في موقع رقم 3 , اما في الربيع (نهاية شهر آذار وشهر نيسان) فسجلت معدلات النتائج مدى من 4.95 ± 0.39مايكروغرام/م3في موقع رقم 4 و 6.08 ± 0.5مايكروغرام/م3في موقع رقم رقم 2. في حين كانت معدلات نتائج الخريف (نهاية شهر تشرين الاول وتشرين الثاني سنة 2011)تتراوح بين 4.89 ± 0.6مايكروغرام/م3في موقع رقم 3 و5.7 ± 0.57مايكروغرام/م3. أما فصل الشتاء (نهاية شهر كانون الاول 2011 وشهر كانون الثاني وشهر شباط 2012) فقد سجلت النتائج مدى بين 4.51 ± 0.46 مايكروغرام/م3في موقع رقم 4 و4.98 ± 0.57مايكروغرام/م3في موقع رقم 3. اظهرت النتائج الحالية حدا غير مسموح به حسب منظمة الصحة العالمية التي حددت تركيز الكادميوم في الهواء بحدود 0.3مايكروغرام/م3. أظهرت نتائج الدراسة الحالية ان معدل تركيز الكادميوم في الدم للعينات المهنية كان 6.418 ± 0.636 مايكروغرام/لتر وكان ذا فرق معنوي تحت مستوى 0.05 بالنسبة لتركيز الكادميوم في الدم للعينات البيئية حيث كان التركيز 5.247 ± 0.418 مايكروغرام/لتر ومعنوي جدا بالنسبة لتركيز الكادميوم في عينات السيطرة 1.854±0.41 مايكروغرام/ لتر. بينت نتائج الدراسة الحالية انخفاضا في مستوى تركيز الكلوتاثيون المختزل بالنسبة للعينات البيئية والمهنية مقارنة مع عينات السيطرة حيث كانت التراكيز2.2595 ± 0.412 مايكرومول/لتر و 2.6625 ± 0.475مايكرومول/لتر و5.4 ± 0.52 مايكرومول/لتر, على التوالي. يمكن الاستنتاج من نتائج الدراسة ان هناك تأثير للكادميوم المنبعث من احتراق الوقود على مستوى الكلوتاثيون في دم العاملين في المحطة.

Keywords

Heavy metals --- Power plant --- cadmium --- GSH.


Article
The concentrations of Natural Radioactivity in Fly Ash Released from Al-Dura thermal Power Plant in The south of Baghdad City
تركيز النشاط الاشعاعي الطبيعي ومعاملات الخطورة لبعض عينات الرماد المتطاير من محطة كهرباء الدورة الحرارية في جنوب مدينة بغداد

Authors: Israa K. Ahmed اسراء كامل احمد --- Mahdi Hadi Jasim مهدي هادي جاسم --- Shafik S .Shafik شفيق شاكر شفيق
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2016 Volume: 57 Issue: 2B Pages: 1192-1197
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The concentrations of naturally radioactive made occurring and technically enhanced radioisotopes of fly ash samples, collected from Al-Dura thermal power Plant- south of Baghdad, have been investigated using the NaI(Tl) gamma-ray spectroscopy. The average Activity concentrations of the radio elements 238 U, 232Th and 40K in Fly ash samples are measured accurately and found to be 33.860, 32.6 and 644.64Bq/kg respectively. On the whole the radionuclide's concentrations are still below the global average of 50 Bq/kg for 238U and 232Th, but are much higher in 40K, relative to the global average, about 500 Bq/kg. The absorbed gamma doses in air, due to naturally occurring radionuclides in fly ash samples, are measured and found within the range; from 46.863 to 86.358 nGy h-1, which is higher than the world average, about 43 nGy h-1. As well as Fly Ash samples have had Radium equivalent activity (Raeq) with an average is about 138.82 Bq/kg. The radiation hazard indexes are calculated based on the above results and found lower than the maximum value. The overall average values of the Hex and Hin indices have been found to be 0.37and 0.32 respectively. Also, the overall average value of the representative gamma index (Iγr) for all fly ash samples is about 1.037, which are greater than the unity (>1). In this case, treatments to the NORM released from that station must be done.

تم البحث عن النظائر المشعة طبيعيا والنظائر المشعة المحسنة تقنيا لعينات من الرماد المتطاير , والتي جمعت من محطة الدورة الحرارية الواقعة جنوب مدينة بغداد, باستخدام منظومة كاشف اشعة كاما- ايوديد الصوديوم. تم قياس تراكيز النشاط للعناصر المشعة ( 238 U و232Thو 40K ) بدقه وكانت على التوالي (33.860 و32.6 و 644.64 بكرل/كغم). بشكل عام وجد ان تراكيز النوى المشعة في الرماد المتطاير اقل من المعدل العام ( 50 بكرل/كغم بالنسبة 238 U و232Th) , باستثناء الزيادة في نظير 40K عن المعدل الدولي (500 بكرل/غم).كذلك قيست جرع اشعة كاما الممتصة في الهواء نتيجة وجود النوى المشعة في الرماد المتطاير وكانت ضمن الحدود 46.863 الى 86.358 نانوكري/ساعة , وهي تمثل اعلى من المعدل الدولي والبالغ 43 نانو كري /ساعة . سجل معدل قيم النشاط المكافئ في الرماد المتطاير بحدود 138.82 بكرل/كغم وكذلك المعدل الاجمالي للمعاملات Hex و Hin بحدود 0.37 و 0.32 على التوالي. وجد ان معامل كاما Iγr لجميع نماذج الرماد المتطاير بحدود 1.037 وهي تمثل اكبر من واحد , الامر الذي يتطلب معالجة اطلاق المواد ذات النشاط الاشعاعي الطبيعي الذي يرافق الرماد المتطاير من المحطة الحرارية في الدوره.


Article
Assessing the Effects of Al- Rasheed Electrical Power Plant on the Quality of Tigris River, Southern of Baghdad by Canadian Water Quality Index (CCME WQI)

Authors: Fatema Sh. Muftin --- Muhanned R. Nashaat --- Luma H.Alazawii
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2018 Volume: 59 Issue: 3A Pages: 1162-1168
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This study was conducted to investigate the effects of Al-Rasheed power plant (RPP) effluents at Al-Zafaraniya city on the physical – chemical of the Tigris River by using Canadian Water Quality Index(CCME WQI).Water samples were taken monthly at four positions and 11parameters were analyzed . The results of this study conducted that there was a significant impact of the RPP effluents on increase of water temperature, turbidity and electrical conductivity, and there was an increase in the phosphate concentration and water hardness at station 2 and the model classified water of Tigris river as poor in winter and fair to marginal in rest season for drinking and aquatic life

Listing 1 - 10 of 33 << page
of 4
>>
Sort by
Narrow your search

Resource type

article (33)


Language

English (23)

Arabic (5)

Arabic and English (3)


Year
From To Submit

2019 (4)

2018 (4)

2017 (4)

2016 (2)

2015 (3)

More...