research centers


Search results: Found 29

Listing 1 - 10 of 29 << page
of 3
>>
Sort by

Article
Effect Of Openiings With Or Without Strenghening On Punching Shear Strength For Reinforced Concrete Flat Plates
تأثير الفتحات مع أو بدون تقويه على مقاومة القص الثاقب لبلاطات خرسانية مستوية مسلحه

Author: Abeer H.H. Al-Shammari
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2011 Volume: 17 Issue: 2 Pages: 218-234
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Reinforced concrete slabs with openings are usually designed with help of traditional rules proposed by building codes. Such methods introduce limitations concerning size, location of openings and magnitude of applied loads. Furthermore, there are some traditional approaches to strengthen reinforced concrete slabs with openings which can be either cumbersome or expensive. This paper studies variable locations of an opening with respect to a central column in reinforced concrete flat plates, and presents a good approach to strengthen this opening by using steel plates. Nine reinforced concrete flat plates are cast with dimensions (length, width and thickness) equal to (850, 470 and 50) mm) using a single concrete mix with average compressive strength (fcu) equals 30 MPa. Each slab contains a square cross-section opening (side length =75 mm) and supported by a central square cross-section column (side length =75 mm). The variables of this study are: the type of opening (with or without strengthening) and the clear distance between the opening and the column which takes the values (0.0d, 2d, 4.5d and 7d), where d is the effective depth. The specimens are tested over a simply supported span at four edges. The test results show that, the ultimate load reaches the maximum value for slab without opening while this load reaches the minimum value for slab with a non-strengthening opening and lies in the pattern of the failure zone (where the clear distance between the column and the opening equals 4.5d). When a comparison is made between the test results ,it is concluded that ;strengthening the slab opening with steel plates causes increasing in the ultimate load by (19.44 ,19.51 ,35.13 and 13.46) % for the specimens (0.0d ,2d ,4.5d and 7d ) respectively.

السقوف الخرسانيه المسلحة والحاوية على فتحات تصمم عادة بمساعدة القواعد التقليدية المقترحة من قبل انظمة ( كودات) البناء .هذه الطرق تقدم حدود بخصوص حجم الفتحات , موقع الفتحات وقيم الأحمال المسلطة.كذلك فان هنالك بعض الطرق التقليدية لتقوية السقوف الخرسانيه المسلحة ذات الفتحات وهذه الطرق أما متعبه أو مكلفه.هذا البحث يدرس مواقع متغيره لفتحه بالنسبة لعمود محوري لبلاطات خرسانيه مسلحه مستوية ,و يقدم طريقه جيده لتقوية تلك الفتحة باستخدام صفائح حديديه. تتضمن الدراسة صب تسعه نماذج من البلاطات الخرسانيه المسلحة بأبعاد (الطول ,العرض والسمك) مساوية إلى (850 ,470 و 50 ) ملم , كل سقف يحتوي فتحه ذات مقطع مربع (طول الضلع =75 ملم) ,باستخدام خلطه خرسانيه واحده بمعدل مقاومه انضغاط مساوية إلى 30 ميكا باسكال ,البلاطة مسنده بواسطة عمود محوري ذو مقطع مربع (طول ضلعه = 75 ملم) . متغيرات هذه الدراسة هي :نوع ألفتحه ( مع أو بدون تقويه ) و المسافة الصافية بين العمود والفتحة والتي أخذت القيم التالية (0 ,2 , 4.5 و 7 ) من العمق الفعال .تم فحص النماذج على فضاء بسيط الإسناد من الجوانب الاربعه . نتائج الفحص بينت أن حمل الفشل وصل أعلى قيمه له في السقف الغير حاوي على فتحه ,و وصل أدنى قيمه له في السقف ذي الفتحة غير المقواة و واقعة على مسار حيز الفشل ( عندما تكون المسافة الصافية بين العمود و الفتحة تساوي 4.5 من العمق الفعال ). عندما عملت مقارنه بين نتائج الفحوصات ,فقد تم استنتاج أن تقوية فتحات السقوف بصفائح حديديه يسبب زيادة في حمل الفشل بنسب ( 19.44 ,19.51 ,35.13 و 13.46 ) % للنماذج (0.0 ,2 , 4.5 و 7 ) من العمق الفعال على التوالي .


Article
Predicting Punching Shear Strength of Ferrocement Slabs Using Back-Propagation Neural Network
التنبؤ بمقاومة القص للسقوف الفيروسمنتية باستخدام تقنيات الشبكات العصبية

Author: Mohammed A. Mashrei محمد عويش مشري
Journal: University of Thi-Qar Journal for Engineering Sciences مجلة جامعة ذي قار للعلوم الهندسية ISSN: 26645564/26645572 Year: 2012 Volume: 3 Issue: 2 Pages: 84-102
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

A back-propagation neural network (BPNN) model is developed to predict the punching shear strength of square ferrocement slabs. The experimental data used for training and testing the neural network model, are collected from several sources. They are arranged in a formatof seven input parameters (the effective span, slab thickness, yield tensile strength of wire mesh, volume fraction of wire mesh, mortar compressive strength, width of square loaded area, boundary condition of the supported slabs) and one output parameter (punching shearstrength). A parametric study is carried out using BPNN to study the influence of each parameter affecting the punching shear strength of ferrocement slabs. A comparison with the experimental results and those from other existing empirical equations demonstrates that thepredictions from BPNN are indeed better. We conclude that the BPNN model may serve as a good tool for predicting the punching shear strength.

استخدمت خوارزمية التعقب الخلفي للشبكات العصبية للتنبؤ بمقاومة القص للسقوف الفيروسمنتية ذات الاشكال المربعة. تم تدريب وفحص الشبكة العصبية بالاعتماد على معلومات عملية أخذت من تجارب سابقة ومن مصادر مختلفة. تم الأخذ بنظر الاعتبار العوامل المؤثرة هندسيا على تصرف السقوف بشكل عام لبناء الشبكة العصبية. مدخلات الشبكة هي: الفضاء الفعال, سمك السقف, مقاومة الخرسانة, نسبة الحديد, مقدار الخضوع للحديد, ابعاد مساحة التحميل بالإضافة إلى طريقة الإسناد المستخدمة أما المخرجات فكانت مقاومة القص للسقوف. كذلك تم في هذا البحث دراسة تأثير كل عنصر من العناصر المدخلة على مقاومة القص للسقوف الفيروسمنتية. تم مقارنة النتائج التي تم الحصول عليها في بحثنا هذا مع بعض النتائج العملية و مع النتائج التي تم الحصول عليها من طرق مقترحة اخرى لحساب مقاومة القص للسقوف. اثبت النتائج بان تقنية الشبكات العصبية وباستخدام خوارزمية التعقب الخلفي هي طريقة جيدة لحساب مقاومة القص ويمكن اعتمادها للتبوء بأي نموذج أخرى ضمن حدود البيانات المستخدمة في بحثنا هذا.

Keywords

Ferrocement --- Punching shear --- Slabs --- Strength --- BPNN.


Article
Punching Shear Resistance of Reinforced Concrete Flat Plate Slabs Strengthened with CFRP
مقاومة القص الثاقب للبلاطات الخرسانية المستوية المسلحة المقواة بالياف الكاربون البوليمرية

Authors: Eyad K. Sayhood --- Mohammed J.Hamood --- Aseel A. Abdul Ridha
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 2 Part (A) Engineering Pages: 511-529
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The purpose of this study is to present a model suitable for analyzing reinforced concrete (RC) slabs strengthened with Carbon fiber reinforced polymer (CFRP) failing in punching shear using the finite element method. a nonlinear three-dimensional finite element analysis has been used to conduct an analytical investigation on the overall behavior of reinforced concrete slabs strengthened with CFRP strips. ANSYS (version 11, 2007) computer program is utilized.The 8-node isoparametric brick elements in ANSYS are used to represent the concrete, the steel bars and CFRP strips are modeled as axial members discrete within the concrete brick elements by assuming perfect bond between the concrete and steel and between the concrete and CFRP strips. The numerical analysis incorporates material nonlinearity due to concrete cracking in tension, nonlinear stress-strain relations of concrete in compression, crushing of concrete and yielding of steel reinforcement. Also, the evaluation of the CFRP strips enhancement in shear strength of RC slabs is investigated.Different types of RC slabs strengthened with CFRP strips have been analyzed. Available experimental results are chosen to check the validity and the accuracy of the adopted models. In general, a good agreement is obtained between the finite element and the experimental results. The maximum percentage difference in ultimate load-carrying capacity is 8.83%. Several parametric studies have been carried out to investigate the effects of some important material parameters on the behavior of strengthened RC slabs. These parameters are the concrete compressive strength, the concrete tensile strength, the number of layers of CFRP strips, the configuration of CFRP strips and the effect of diagonal stirrups of CFRP.

الغرض من هذه الدراسة هو تقديم نموذج لتحليل البلاطات الخرسانية المسلحة المقواة بالياف الكاربون البوليمرية (التي تفشل بقوى القص للثاقب) بأستخدام طريقة العناصر المحددة . تم استعمال طريقة العناصر المحددة ثلاثية الابعاد اللاخطية لتقصي سلوك البلاطات الخرسانية المقواة بالياف الكاربون البوليمرية. بالاستفادة من برنامج ANSYS (الأصدار الحادي عشر, 2007). تم استخدام عناصر طابوقية ثلاثية الابعاد ذات ثمانية عقد في برنامج ANSYS لتمثيل الخرسانة. تم تمثيل حديد التسليح والياف الكاربون البوليمرية كعناصر محورية منفصلة داخل العناصر الطابوقية مع افتراض وجود ترابط تام بين الخرسانة وحديد التسليح وبين الخرسانة والياف الكاربون البوليمرية. هذا الأسلوب يعتبر ان المواد لا تتصرف تصرفا خطيا تبعاً الى تشقق الخرسانة في مناطق الشد والتصرف اللاخطي للخرسانة تحت الضغط وتهشم الخرسانة وخضوع حديد التسليح. أيضا تهدف الدراسة الى إيجاد الزيادة الحاصلة في سعة القص للبلاطات الخرسانية الناتجة عن استخدام الالياف الكاربونية.تم تحليل أنواع مختلفة من البلاطات الخرسانية المقواة بألياف الكاربون البوليمرية وقورنت النتائج المستحصلة لمنحنيات الحمل – الأزاحة بطريقة العناصر المحددةمع النتائج المختبرية المتوفرة. بشكل عام تم الحصول على توافق جيد بين النتائج التحليلية بطريقة العناصر المحددة والنتائج المختبرية. وكان اكثر فرق للتحميل الاقصى في البلاطات هو 8.83%.أجريت دراسة لتحري تأثير بعض المتغيرات المهمة على سلوك البلاطات الخرسانية المقواة بألياف الكاربون البوليمرية. , تضمنت هذه الدراسة تأثير مقاومة الانضغاط للخرسانة و مقاومة الشد للخرسانة وعدد طبقات الالياف المستخدمة لتقوية البلاطات الخرسانية و تشكيل شرائح الياف الكاربون البوليمرية وتاثير وجود الاتاري المائلة لالياف الكاربون البوليمرية.


Article
STRUCTURAL BEHAVIOR OF EMBEDDED SHEAR HEAD IN MODIFIED REACTIVE POWDER FLAT PLATE CONCRETE WITH OPENING
التصرف الانشائي لتسليح القص الطوقي المطمور في بلاطة مستوية من خرسانة المساحيق الفعالة المعدلة بوجود الفتحات

Author: Abeer Hassan Wenas
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2017 Volume: 21 Issue: 3 Pages: 102-118
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

This study presents an experimental investigation on one type of embedded shearhead called ( collar head reinforcement) as shear reinforcement for tow type of reinforced concrete flat plate with presence of opening on punching shear strength. This type of shearhead is one of the structural solution that are used to increase the shear strength of flat slab . In the present research , ten specimens are tested with dimensions (1000x1000x75 mm) which are divided into two groups; the first group is a normal strength concrete with a compressive strength 30MPa; the second group is modified reactive powder concrete with a compressive strength 90MPa. Each group consists of five slabs. By using collar shearhead around the column sides and extended to the opening NSC4, the cracking load can be increased to 100% solid flat slab without collar head. For serviceability of flat plate with opening, the deflection and crack width can be reduced by using collar head around the column sides extended to the opening. The reduction can be continued by increasing the compressive strength of the concrete. The losses in the critical section property in the present work do not exceed 7% in the case of specimen with opening with dimension equal to the supporting column dimensions. By concentrating on the slabs which had openings adjacent to the column but strengthened with collar head in different configurations, the percentage of the critical section perimeter was between (103.2– 119.3) % that was reflected to the capability of this type of shear reinforcement (collar shear head) in making up the shortfall in the critical section due to the presence of openings.

تقدم هذه الدراسة بحث عملي لاحد انواع تسليح القص للسقوف المستوية والمسمى بتسليح القص الطوقي لنوعين من الخرسانة, مع وجود فتحات ملاصقة للعمود . ان تسليح القص (التسليح الطوقي) يعتبر احد الحلول الانشائية لزيادة مقاومة القص للسقوف المستوية. ان هذا البحث يتضمن اختبار عشرة نماذج ذات ابعاد (1000*1000*75) ملم ومقسمة الى مجموعتين المجموعة الاولى تتضمن خرسانة مسلحة عادية ذات مقاومة انضغاط 30 ميكا باسكال والمجموعة الثانية تتضمن خرسانة المساحيق الفعالة المعدلة ذات مقاومة انضغاط 90 ميكا باسكال وكل مجموعة تتكون من خمسة نماذج وكل مجموعة تحتوي على مرجع بدون فتحة ملاصقة للعمود وتحتوي على نموذج يحتوي على فتحة ملاصقة للعمود ولاتحتوي على تسليح القص الطوقي وثلاثة نماذج تحتوي على فتحة ملاصقة للعمود وتحتوي على تسليح القص الطوقي . ومن الناحية الخدمية التشوه الحاصل وعرض الشق يمكن تقليله باستخدام التسليح الطوقي الفولاذي المحاط بالعمود والممتد الى الفتحة الملاصقة للعمود. ان النقص الحاصل في المقطع الحرج لا يتجاوز ال 7% يالنسبة للنماذج الحاوية على فتحات ملاصقة للعمود وباستخدام تسليح القص الطوقي تزداد النسبة (103.2-119.3)% وهذا يشير الى قدرة هذا النوع من التسليح ( تسليح القص الطوقي الفولاذي )في تعويض النقص الحاصل في المقطع الحرج نتيجة وجود الفتحات.


Article
EXPERIMENTAL STUDY ON THE BEHAVIOR OF DIFFERENT TYPES OF STEEL FIBER REINFORCED CONCRETE MIX OF TWO WAY-SLABS SUBJECTED TO DIFFERENT HEAT TEMPERATURE

Author: Omar Shamal Farhan
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2019 Volume: 23 Issue: 1 Pages: 26-42
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

This research aims to study the influence of steel fibers on the behavior of eighteen reinforced concrete (RC) slabs under different temperatures. The main investigated parameters in this paper were concrete type i.e. Normal-Strength Concrete (NSC), High-Strength Concrete (HSC) and Light-Weight Concrete (LWC), the effect of various parameters such as; amount of steel fiber ratio (0% and 2%) on failure load, crack patterns, and load- deflection response, have been studied. In these slabs the amounts of reinforcements were kept constant. The study also includes the type's failure and effect of types of concrete when all specimens are exposed to several temperature levels (25Co, 400Co, 600Co). It showed that, there is a reduction of strength with the increase of temperature. The test results show that as the volume of the steel fibers increase the punching shear strength increased and the presence of fibers delay the appearance of the first crack in the slab and gave less deflection than the slab without fibers.


Article
Effect of Separation Distance between the Columns on Punching Pattern for Flat Plates with High Strength Concrete
تاثير مسافة الفصل بين الاعمدة على القص للبلاطات المسطحة ذات الخرسانة عالية المقاومة

Author: Abeer Hussein Al-Shammari عبير حسين الشمري
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2010 Volume: 14 Issue: 3 Pages: 162-177
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

When a reinforced concrete slab is supported by coupled columns, these columns may behave as one column or as separated two columns according to the separation distance between them. Therefore, this study investigates the effect of separation distance of the columns on punching pattern for flat plates with high strength concrete and compares their results with other results of flat plates with normal strength concrete. Eight reinforced concrete slab specimens with coupled columns are cast with dimensions (length, width and thickness) equal to (850,470 and 50mm) by using a single high strength concrete mix with average compressive strength (f`c) that equals (55MPa) supported by coupled circular cross-section columns (diameter=85mm), these columns are located at the centerline of the slab in long direction; while in the short direction ,the positions of the columns are variable with respect to the centerline of the slab. However, the problem remains symmetric about the two axes. The specimens are tested over a simply supported span at four edges. The variable of this study is the clear distance between columns which takes the values (0.05 ,0.5 ,1 ,1.5 ,3 ,5 ,7 and 9)d ,where d is the effective depth. The test results show that ,the ultimate load reaches the maximum value when the clear distance between columns equals 9d and decreases by about (17.3 to 44.5) % of the maximum ultimate load when the clear distance between columns decreases from 7d to 0.05d .Also it is noticed that when the clear distance between columns is in the range (0.05d to 7d) ,the failure zone behaves as one zone; while when the clear distance between columns is equal to 9d , the failure zone separates into two zones. When the test results are compared with other results of flat plates with normal strength concrete(f`c=24MPa),it is concluded that ;when the concrete compressive strength factor ( )is increased by about 50% (f`c is increased from 24 to 55MPa),the ultimate loads increase by (16,17.5,20.7,21.4,31.67,31.74 and 32.84) % for the specimens from 0.05d to 9d respectively. So this study investigates the effect of separation distance of the columns on punching pattern for flat plates with high strength concrete.

عندما يكون السقف الخرساني المسلح مسند بواسطة عمودين متقاربين ,فان هذين العمودين إما أن يتصرفان كعمود واحد أو كعمودين منفصلين حسب المسافة الفاصلة بينهما . لذلك فان هذه الدر اسه تبحث تأثير مسافة الفصل ما بين الاعمده على نمط الفشل لبلاطات مسطحه ذات خرسانه عاليه ألمقاومه و مقارنتة مع بلاطات ذات خرسانة اعتيادية ألمقاومه . تتضمن الدر اسه صب ثمانية نماذج من البلاطات الخرسانية المسلحة بأبعاد (الطول , العرض والسمك) مساوية إلى(470,850و50)ملم بخرسانة ذات مقاومه تساوي 55ميغا باسكال مسنده بواسطة عمودين متقاربين مقطعهما دائري قطره يساوي 85ملم , هذين العمودين يقعان على الخط المحوري للسقف بالاتجاه الطويل , بينما بالاتجاه القصير فان موقع العمودين يكون متغير بالنسبة للخط المحوري للسقف مع الاحتفاظ بالتناظر حول المحورين. تم فحص النماذج على فضاء بسيط الإسناد من إضلاعه الأربعة. المتغير لهذه الدراسة هو المسافة ألصافيه بين العمودين والتي أخذت القيم التالية (9,7,5,3,1.5,1,0.5,0.05) من العمق الفعال . بينت نتائج الفحوصات أن حمل الفشل وصل إلى أعلى قيمة عندما أصبحت المسافة بين الأعمدة مساوية إلى 9d وتتناقص هذه القيمة بنسبة تتراوح بين (44.5-17.3) % من أقصى حمل للفشل عندما تناقصت المسافة بين الأعمدة من 7d إلى 0.05d. كذلك لوحظ انه عندما تكون المسافة الصافية بين الأعمدة بحدودd 0.05 إلى 7d فأن منطقة الفشل تنفصل عن البلاطة كجزء واحد، لكن عندما تكون المسافة الصافية ما بين الأعمدة تساوي 9d فأن عندما تم مقارنة نتائج هذا الفحص مع نتائج أخرى لبلاطات مسلحه ذات خرسانه اعتيادية المقاومة فقد تم استنتاج أن معامل مقاومة الانضغاط ( ) عندما يزداد بنسبة حوالي 50% (أي عندما تزداد f`c من 24 إلى 55 ميغا باسكال) فان تحمل ألبلاطه يزداد بنسب (16.2 ,17.54 ,20.76 ,21.37 ,31.67 ,31.75 ,32.85, 34.15)% للنماذج من d 0.05 إلىd 9 على التوالي.


Article
Fault Tree Analysis as a Modern Technique for Investigating Causes of Some Construction Project Problems

Author: Abbas M. Burhan
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2010 Volume: 16 Issue: 2 Pages: 5214 -5224
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Construction projects contain many problems that can occur during the execution. Each problem results from many causes. Fault tree analysis (FTA) technique is a graphical model for analyzing causes of a problem (or undesired event) using logic gates to describe combinations of individual faults that can create an undesired event. Each level of the tree lists the lower level events that are necessary to cause the event shown in the level above it. The assessment process of a problem with FTA technique can be divided into two types: qualitative and quantitative assessment. As a case study to apply FTA technique in construction field, the researcher studied a building in Baghdad that had punching shear problem to analyze the causes lead to this problem. This research aims to introduce the main principles of FTA technique and how to use in identifying and analyzing the causes of problems that can occur in the construction projects. Also, it aims to compute the probability of occurrence of any problem or undesired event.

ان المشاريع الأنشائية تحتوي على الكثير من المشاكل أثناء التنفيذ وكل مشكلة تنتج من عدة أسباب. تقنية تحليل شجرة العيب (FTA) هي نموذج تصويري لتحليل أسباب مشكلة معينة (أو حدث غير مرغوب) بأستخدام رموز منطقية (Logic Gates) لوصف مجموعة من العيوب أو الأسباب التي تولد الحدث الغير مرغوب فيه. كل مستوى من شجرة العيب يضم الأحداث الأقل مستوى التي حدوثها يكون ضروري لتسبب الحدث الذي في أعلى المستوى من الشجرة. أن عملية تقييم أي مشكلة ضمن تقنية تحليل شجرة العيب يمكن تقسيمها الى نوعين: تقييم نوعي وتقييم كمي. كدراسة حالة لتطبيق تقنية (FTA) في حقل الأنشاء، أخذ الباحث بناية في بغداد تعاني مشكلة قص الأنثقاب لتحليل الأسباب التي أدت الى هذه المشكلة. يهدف هذا البحث الى تقديم المباديء الأساسية لتقنية FTA وكيفية أستخدامها في تحليل أسباب المشاكل التي قد تحصل في المشاريع الأنشائية وكيفية أحتساب أحتمالية حدوث أي مشكلة.


Article
Effect of Cross Section Properties on Flat Plate Behavior
تأثير خواص المقطع العرضي على سلوك اللوحة المستوية

Author: Awadh O. Ajeel
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2010 Volume: 28 Issue: 9 Pages: 1802-1815
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

On the wise of structural advantages of flat plate slab systems, theresearches still deal with punching shear hazards and solution techniques foradopting a rational design comes from experimental investigations. Beside thatthere is a rapid development in production the high performance concretes usingchemical additives and wide spectrum of different features fibers which availadditional options for the structural designers.The present work is an experimental study adopts the comparison betweenuniform concrete sections with specific strength and hybrid sections (consists oftwo different layers with different strength in the top half and the bottom one) toprovide reinforced concrete flat plate slabs and conclude the more advantageoption for improving their behaviors against eventual punching shear failure.Normal strength, high strength and fibrous concrete with (34, 48 and 21) MPacompressive strength respectively are used to produce the slabs in this study.The results revealed the preference of the high strength uniform section inimproving the slab behavior besides increasing its ultimate load twice incomparison with a hybrid section contains high strength concrete at the top halfonly and there is no advantage from increasing the tension zone strength on thehybrid section slab behavior except the ductility.

على صعيد المزايا الإنشائية لمنظومات بلاطات الألواح المستوية، لاتزال الأبحاثمستمرة بخصوص مخاطر القص الثاقب وسبل معالجته لغرض الخروج بتصميم مقبولاعتماداً على التجارب العملية. وإلى جانب ذلك فإن التطور السريع في إنتاج الخرسانات عاليةالأداء باستخدام المضافات الكيميائية وطيف واسع من الألياف ذات الصفات المتباينة يوفرخيارات إضافية للمصممين الإنشائيين.تعتمد الدراسة الحالية على مبدأ المقارنة بين النتائج العملية لمقاطع موحدة ذات مقاومةمعينة ومقاطع مهجنة تختلف فيها المقاومة بين النصفين الأعلى والأسفل استخدمت لإنتاجبلاطات خرسانية مسلحة على هيئة ألواح مستوية لغرض استنتاج الخيار الأفضل لتحسينسلوك تلك البلاطات تجاه فشل القص الثاقب. استخدمت خرسانة اعتيادية وخرسانة عالية48 و 21 ) نت/ملم 2 لإنتاج البلاطات في ، المقاومة وأخرى ليفية بمقاومة إنضغاط قيمتها ( 34هذه الدراسة.كشفت النتائج المختبرية أفضلية المقاطع الموحدة ذات المقاومة العالية في تحسين سلوكالبلاطات إلى جانب زيادة حمل البلاطة الأقصى مرتين بقدر الزيادة المستحصلة من زيادةمقاومة منطقة الانضغاط للبلاطة مهجنة المقطع وكذلك فلا فائدة من زيادة مقاومة منطقة الشدفي تحسين تصرف البلاطة مهجنة المقطع في ما عدا تحسين خاصية المطيلية.


Article
PUNCHING SHEAR AND FLEXURAL STRENGTHS OF SELF COMPACTED CONCRETE NON-RECTANGULAR SHAPED FLAT PLATE SLABS
تحليل مقاومة القص الثاقب ومقاومة الانثناء للبلاطات الصفائحية الخرسانية ذاتية الرص ذات الاشكال غير المستطيلة

Author: Ali H. Aziz علي حميد عزيز
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2011 Volume: 4 Issue: 1 Pages: 95-107
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

ABSTRACT :- This study is conducted to investigate experimentally the punching shear and flexural strengths of reinforced concrete flat plate slabs made with Non-Rectangular (triangular and trapezoidal) shaped. Four test self-compacting concrete slab groups were manufactured, each of which consisted of three slab specimens identical in size and shape but different in constituent’s properties. All slabs are simply supported along the all edges and subjected to single point load applied at the center of gravity of each slab. Experimental results shows that the use of self compacting concrete improves the punching shear resistance and allows higher forces to be transferred through the slab-column connection. For slabs which were designed to fail in punching shear, the ultimate capacity of the tested specimens increased by (7%) to (20%) when the shape of slab specimens changed from triangular to trapezoidal. In contrast of slabs which were designed to fail in flexure, the ultimate capacity of the tested specimens increased from (16%) to (58%) when the shape of slab specimens changed from triangular to trapezoidal. The cracking load depends essentially on concrete strength and not on slab configuration, but, the ultimate capacity depends on both, concrete strength and shape of slab. Keywords:- Punching Shear, Flexural, Self compacted, Slabs, Concrete, Non-Rectangular

الخلاصة يتناول هذا البحث دراسة عملية لتقييم مقاومة القص الثاقب ومقاومة الانثناء للبلاطات الخرسانية ذاتية الرص ذات الشكل المثلثي والشكل شبة المنحرفة ،تم فحص اربعة مجاميع من البلاطات (اعتمادا على الشكل) كل مجموعة تضم ثلاثة بلاطات متشابهه في الشكل ومختلفة في التسليح و مقاومة انضغاط الخرسانة. اسندت البلاطات المفحوصة اسنادا بسيطا من جميع الاتجاهات وتم تسليط الاحمال بواسطة حمل مركز في مركز ثقل كل بلاطة. اظهرت الدراسة ان استخدام الخرسانة ذاتية الرص قد حسن من مقاومة البلاطات المفحوصة وسمح بانتقال احمال عالية من خلال المفصل الرابط بين البلاطة و العمود الخرساني. بالنسبة للبلاطات المصممة للفشل بالقص الثاقب، ازدادت مقاومة المقطع حوالي (7%) الى (20%) عندما تغير شكل البلاطة من الشكل المثلثي الى شبه المنحرف، بينما ازدادت مقاومة المقطع بمقدار (16%) الى (58%) عندما تغير شكل البلاطة من الشكل المثلثي الى شبه منحرف بالنسبة للبلاطات المصممة للفشل بالانثناء. اظهرت النتائج، كذلك، ان حمل التشقق يعتمد بصورة رئيسية على مقاومة الخرسانة المستخدمة ، بينما يعتمد الحمل الاقصى على مقاومة الخرسانة المستخدمة وشكل البلاطة.


Article
Punching Shear Failure Characteristics Of Flat Slabs Using Reactive And Modified Powder Concrete With Steel Fibers
خصائص فشل القص الثاقب للبلاطات المسطحة باستخدام خرسانة المساحيق الفعالة الاعتيادية والمطورة والألياف الحديدية

Authors: Hassan F. Hassan حسن فلاح حسن --- Kaiss F. Sarsam قيس فؤاد سرسم
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2013 Volume: 17 Issue: 5 Pages: 124-140
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

This work is devoted to study the mechanical properties of reactive powder concrete(RPC) and modified reactive powder concrete (MRPC) as a material as well as studying the punching shear behavior of RPC and MRPC slabs. The experimental program includes investigating the effect of steel fiber volumetric ratio (Vf) and absence of coarse aggregates on some important mechanical properties of RPC and MRPC such as compressive strength, modulus of elasticity (E), splitting tensile strength and modulus of rupture. Additional experimental tests are also conducted to study the effect of Vf, steel reinforcement ratio (ρ) and slab thickness on the failure characteristics of the punching shear (in terms of observation of failure, shape of the failure zone, size of the failure zone, failure angles, critical section perimeters and ultimate punching shear stress ) of simply supported reinforced RPC slabs having dimensions of 1000×1000× 50 or 70 mm under concentrated load at the center of the slab.

يهتم البحث الحالي بدراسة الخواص الميكانيكية لخرسانة المساحيق الفعالة (RPC) وخرسانة المساحيق الفعالة المعدلة (MRPC) كمادة إضافة إلى دراسة تصرف القص الثاقب ((Punching Shear للبلاطات المصنعة من هذه الخرسانة. يتركز البرنامج العملي من البحث على دراسة واستقصاء تأثير النسبة الحجمية للألياف الفولاذية ووجود الركام الخشن على بعض الخواص الميكانيكية المهمة لخلطة خرسانة المساحيق الفعالة مثل مقاومة الانضغاط للخرسانة ومقاومة شد الانشطار ومنحني الإجهاد-الانفعال تحت تأثير انضغاط أحادي المحور ومعامل الانثناء. يتضمن البحث أيضا دراسة تأثير نسبة حديد التسليح وسمك البلاطات إضافة إلى المتغيرات أعلاه على خصائص الفشل للقص الثاقب (بدلالة مساحة الفشل, زاوية الفشل, محيط المنطقة الحرجة والانفعال الأقصى للقص الثاقب) لبلاطات مصنعة من خرسانة المساحيق الفعالة بأبعاد( 1000X1000X 50أو 70) مم ذات إسناد بسيط تحت تأثير حمل مركز في منتصف البلاطة.

Listing 1 - 10 of 29 << page
of 3
>>
Sort by
Narrow your search

Resource type

article (29)


Language

English (24)

Arabic and English (4)


Year
From To Submit

2019 (2)

2018 (2)

2017 (3)

2016 (1)

2015 (5)

More...