research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Determination Micro Spectrohotometric of Pyridoxine Hydrochloride and Nicotinamide via Derivative Spectrophotometry First and Second
التقدير الطيفي المايكروي لعقاري هيدروكلوريد البايريدوكسين والنيكوتين امايد بطريقة مشتقة الطيف الأولى والثانية

Authors: Mohammed Qasim Al-Sammaraee محمد قاسم السامرائي --- Khlaf Faris Al-Sammaraee خلف فارس السامرائي
Journal: Tikrit Journal of Pure Science مجلة تكريت للعلوم الصرفة ISSN: 18131662 Year: 2017 Volume: 22 Issue: 12 Pages: 79-90
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

A simple, sensitive and accurate spectrophotometric method for determination of PYR.HCl and NTA in pure and pharmaceutical forms. The method based on group of known digital data used to separate the response signals for sample contains the two components without need to separating via first and second derivative of spectra. The method obtained obeying to the Beers law in the concentration range between )5-45 µg.ml-1( for two components in the presence of PYR. HCl )15µg.ml-1( and NTA (5µg.ml-1) with another components at wavelength (210 nm ) respectively . The Rec % range was between ) 98.5354 - 103.4335 % (and RSD% (0.0864 - 0.1487 %), LOD) 1.0822 µg.ml-1, ( LOQ ( 3.6075 µg.ml-1 (PYR.HCl in presence of NTA, The Rec% range was between )96.1418 - 102.9273 % (and RSD% (0.2165–0.4933 % ), LOD (0.7273µg.ml-1 ,(LOQ (2.4252 µg.ml-1( NTA in presence of PYR. HCl .

تم تقدير عقاري هيدروكلوريد البايريدوكسين ( PYR.HCl ) والنيكوتين امايد ( NTA ) في اشكالها النقية وفي مستحضراتها الصيدلانية بتطوير طريقة طيفية، بسيطة وحساسة واقتصادية ، تستند الطريقة على مجموعة من البيانات الرقمية والمعروفة جيداً في فصل إشارات الاستجابة للإنموذج الحاوي على المكونين دون الحاجة الى فصلهما عن طريق مشتقة الطيف الأولى D1 والثانية D2 ، أظهرت الطريقة مطاوعة لقانون بير – لامبرت لمدى من التراكيز تراوحت بين (5- 45 µg.ml-1) لهيدروكلوريد البايريدوكسين بوجود النيكوتين امايد بتركيز (5 µg.ml-1) و(5 - 45 µg.ml-1) للنيكوتين امايد بوجود هيدروكلوريد البايريدوكسين بتركيز (15 µg.ml-1) عند الطول الموجي نفسه 210 nm)) اذ يظهر تداخلا تاما في طيفي المركبين، إذ تراوحت الاسترجاعية المئوية Rec% مابين (98.5354-103.4335%) بينما تراوح معامل الانحراف القياسي النسبي RSD% ما بين (0.0864–0.1487%) وحد الكشف LODبقيمة (1.0822µg.ml-1) والحد الكمي LOQبقيمة (µg.ml-1 3.6075) لهيدروكلوريد البايردوكسين بوجود النيكوتين امايد بينما تراوحت الاسترجاعية المئوية Rec% مابين (96.1418-102.9273%) و معامل الانحراف القياسي النسبي RSD% ما بين (0.2165–0.4933%) وحد الكشف LOD بقيمة ( 0.7273 µg.ml-1 ) والحد الكمي LOQبقيمة (µg.ml-1 2.4252) للنيكوتين امايد بوجود هيدروكلوريد البايريدوكسين.


Article
Flow Injection- Spectrophotometric Determination of Salbutamol Sulphate and Pyridoxine Hydrochloride Using 2,4-Dinitrophenylhydrazine
التقدير الطيفي-الحقن الجرياني لكبريتات السالبيوتامول وهيدروكلوريد البايردوكسين باستخدام 2،4- ثنائي نايتروفنيل هيدرازين

Authors: Sadeem Subhi سديم صبحي --- Mouyed Q. Al-Abachi مؤيد قاسم العبايجي
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2013 Volume: 54 Issue: 1 Pages: 6-16
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A batch and flow injection (FI) methods with spectrophotometric detection is proposed for determining of two of phenolic drugs: salbutamol sulphate(SLB)and pyridoxine hydrochloride(PYD) in pure and in pharmaceutical formulations. The methods utilized an oxidative-coupling reaction based upon oxi¬dation of 2,4-dinitrophenylhydrazine (DNPH) with sodium periodate, where an electrophilic intermediate (diazonium salt of the reagent) is produced, which couples with either SLB or PYD in the presence of sodium hydroxide yielding a highly colored condensation product. The absorbance is measured after 15min at 525and515 nm for SLB and PYD respectively. Calibration graphs for both batch and FIA methods were linear over the concentration ranges of 1-24μg/ml for SLB and 0.4-16μg/ml for PYD, and of 30-1100μg/ml for SLB and20-1200μg/ml for PYD respectively. A detection limits of 0.580μg/ml SLB and 0.150μg/ml PYD for batch method, and 15.32μg/ml SLB and12.21μg/ml PYD for FIA method. The proposed methods were applied successfully to the determination of SLB and PYD in phar¬maceutical preparations and were compared statistically with reference methods by means of t- test and F- test and were found not to differ significantly at 95% confidence level. The procedures are characterized by its simplicity, accuracy and precision. The results obtained were in good agreement with those obtained using reference methods for comparison

يتضمن البحث تطوير طرق طيفية بسيطة للتقدير الكمي للمقادير الضئيلة من كبريتات السالبيوتامول وهيدروكلوريد البايردوكسين في المحاليل النقية والمستحضرات الصيدلانية باستخدام المطياف الضوئي بطريقتي الدفعة والحقن الجرياني .اعتمدت الطرق على تفاعل الازدواج التاكسدي حيث يتم اكسدة كاشف 2،4-ثنائي نايتروفنيل هيدرازين باستخدام بيرايودات الصوديوم وتكوين مادة وسطية الكتروفيلية(ملح الدايازونيوم للكاشف) ومن ثم تدخل تفاعل الازدواج مع كبريتات السالبيوتامول اوهيدروكلوريد البايردوكسين في وسط قاعدي حيث تتكون نواتج ملونة مستقرة. قيست الامتصاصية بعد15دقيقة من بدء التفاعل عند طول موجي 525 و515 نانوميتر لكل من كبريتات السالبيوتامول وهيدروكلوريد البايردوكسين على التوالي .تشير منحنيات الامتصاص مقابل التركيز بان قانون بير ينطبق ضمن مدى التركيز 1-24 و و0,4-16 مايكروغرام.مل-1 من كبريتات السالبيوتامول وهيدروكلوريد البايردوكسين لطريقة الدفعة ،اما بطريقة الحقن الجرياني فكان مدى التركيز من 30-1100 و 20- 1200 مايكروغرام.مل-1من كبريتات السالبيوتامول وهيدروكلوريد البايردوكسين على التوالي وبحد كشف 0,580 و0,150. مايكروغرام.مل-1 من كبريتات السالبيوتامول وهيدروكلوريد البايردوكسين لطريقة الدفعة واما لطريقة الحقن الجرياني فكانت 15,32 و 21,12 مايكروغرام.مل-1لكل من كبريتات السالبيوتامول وهيدروكلوريد البايردوكسين على التوالي .تمت دراسة الظروف المثلى للتفاعل وجميع المتغيرات الكيميائية والفيزيائية بدقة وطبقت الطريقتين بنجاح على المستحضرات الصيدلانية الحاوية على كبريتات السالبيوتامول وهيدروكلوريد البايردوكسين .وقورنت النتائج التي تم الحصول عليها مع نتائج طرق التحليل القياسية للادوية اعلاه وبطريقة احصائية (اختبار tواختبارF) واظهرت النتائج عدم وجود فرق جوهري بين نتائج الطرق المقترحة ونتائج الطرق القياسية.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic (1)

English (1)


Year
From To Submit

2017 (1)

2013 (1)